• Title/Summary/Keyword: Charge Pump

Search Result 296, Processing Time 0.025 seconds

A CMOS Phase-Locked Loop with 51-Phase Output Clock (51-위상 출력 클록을 가지는 CMOS 위상 고정 루프)

  • Lee, Pil-Ho;Jang, Young-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.408-414
    • /
    • 2014
  • This paper proposes a charge-pump phase-locked loop (PLL) with 51-phase output clock of a 125 MHz target frequency. The proposed PLL uses three voltage controlled oscillators (VCOs) to generate 51-phase clock and increase of maximum operating frequency. The 17 delay-cells consists of each VCO, and a resistor averaging scheme which reduces the phase mismatch among 51-phase clock combines three VCOs. The proposed PLL uses a 65 nm 1-poly 9-metal CMOS process with 1.0 V supply. The simulated peak-to-peak 지터 of output clock is 0.82 ps at an operating frequency of 125 MHz. The differential non-linearity (DNL) and integral non-linearity (INL) of the 51-phase output clock are -0.013/+0.012 LSB and -0.033/+0.041 LSB, respectively. The operating frequency range is 15 to 210 MHz. The area and power consumption of the implemented PLL are $580{\times}160{\mu}m^2$ and 3.48 mW, respectively.

Performance of R290 and R1270 as Alternative Refrigerants of R22 According to Temperature Variations of Evaporator and Condenser (증발기와 응축기 온도변화에 따른 R22 대체냉매 R290 및 R1270의 성능평가)

  • Baek In-Cheol;Park Ki-Jung;Shim Yun-Bo;Jung Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.761-767
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons R290 and R1270 was measured in an attempt to substitute R22 under 3 different temperature conditions. They were tested in a refrigerating bench tester with a hermetic rotary compressor. The test bench provided about 3.5 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ and $-21/28^{\circ}C$ in the evaporator and condenser, respectively. Test results show that the coefficient of performance (COP) of these refrigerants is up to 11.54% higher than that of R22 in all temperature conditions. Compressor discharge temperatures were reduced by $14{\sim}31^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 58% as compared to R22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for residential air-conditioning and heat pumping application.

Performance Evaluation of R22 Alternative Refrigerants According to Temperature Variations of Evaporator and Condenser (증발기와 응축기 온도변화에 따른 R22 대체냉매의 성능평가)

  • Baek, In-Cheol;Shim, Yun-Bo;Jung, Dong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.58-63
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons and 3 mixtures was measured in an attempt to substitute R22 under 3 different temperature conditions. The mixtures were composed of R1270(propylene), R290(propane) and R152a. They were tested in a refrigerating bench tester with a hermetic rotary compressor The test bench provided about 3.5 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of $7^{\circ}C/45^{\circ}C$ and $-7^{\circ}C/41^{\circ}C$ and $-21^{\circ}C/28^{\circ}C$ in the evaporator and condenser, respectively. Test results show that the coefficient of performance (COP) of these refrigerants is up to 11.54% higher than that of R22 in all temperature conditions. Compressor discharge temperatures were reduced by $14{\sim}31^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 58% as compared to R22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for residential air-conditioning and heat pumping application.

  • PDF

A Discrete-Time Loop Filter Phase-locked loop with a Frequency Fluctuation Converting Circuit (주파수변동전환회로를 가진 이산시간 루프 필터 위상고정루프)

  • Choi, Young-Shig;Park, Kyung-Seok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.89-94
    • /
    • 2022
  • In this paper, a discrete-time loop filter(DLF) phase-locked loop with a Frequency Fluctuation Converting Circuit(FFCC) has been proposed. Discrete-time loop filter can improve spur characteristic by connecting the charge pump and voltage oscillator discretely unlike a conventional continuous-time loop filter. The proposed PLL is designed to operate stably by the internal negative feedback loop including the SSC acting as a negative feedback to the discrete-time loop filter of the external negative feedback loop. In addition, the phase noise is further improved by reducing the magnitude of the loop filter output voltage variation through the FFCC. Therefore, the magnitude of jitter has been reduced by 1/3 compared to the conventional structure. The proposed phase locked loop has been simulated with Hspice using the 1.8V 180nm CMOS process.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

A Design of PLL and Spread Spectrum Clock Generator for 2.7Gbps/1.62Gbps DisplayPort Transmitter (2.7Gbps/1.62Gbps DisplayPort 송신기용 PLL 및 확산대역 클록 발생기의 설계)

  • Kim, Young-Shin;Kim, Seong-Geun;Pu, Young-Gun;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.21-31
    • /
    • 2010
  • This paper presents a design of PLL and SSCG for reducing the EMI effect at the electronic machinery and tools for DisplayPort application. This system is composed of the essential element of PLL and Charge-Pump2 and Reference Clock Divider to implement the SSCG operation. In this paper, 270MHz/162MHz dual-mode PLL that can provide 10-phase and 1.35GHz/810MHz PLL that can reduce the jitter are designed for 2.7Gbps/162Gbps DisplayPort application. The jitter can be reduced drastically by combining 270MHz/162MHz PLL with 2-stage 5 to 1 serializer and 1.35GHz PLL with 2 to 1 serializer. This paper propose the frequency divider topology which can share the divider between modes and guarantee the 50% duty ratio. And, the output current mismatch can be reduced by using the proposed charge-pump topology. It is implemented using 0.13 um CMOS process and die areas of 270MHz/162MHz PLL and 1.35GHz/810MHz PLL are $650um\;{\times}\;500um$ and $600um\;{\times}\;500um$, respectively. The VCO tuning range of 270 MHz/162 MHz PLL is 330 MHz and the phase noise is -114 dBc/Hz at 1 MHz offset. The measured SSCG down spread amplitude is 0.5% and modulation frequency is 31kHz. The total power consumption is 48mW.

Relationship of Hemodynamic Changes during Off-Pump Coronary Bypass Grafting and Their Effects on Postoperative Outcome (심폐바이패스 없이 시행하는 관상동맥 우회수술 중의 혈역학적 변수들의 변화양상 및 수술 후 결과에 미치는 영향)

  • 허재학;장지민;김욱성;장우익;이윤석;정철현
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.576-582
    • /
    • 2003
  • During the Off-Pump Coronary Arterial Bypass surgery (OPCAB), the manipulation of the heart can depress cardiac contractility and cause hemodynamic instability. In this study, hemodynamic parameters were measured during operation and the laboratory and clinical data were investigated to evaluate their effects on postoperative outcome. Material and Method: From March 2001 to August 2002, 50 consecutive patients who underwent OPCAB were included in this study. During the same period, total number of CABG was 71 The blood pressure, pulmonary artery pressure, mixed venous oxygen saturation, and cardiac index were measured before manipulation, after application of stabilizer, and at the end of anastomosis. Postoperatively, we measured the cardiac enzymes such as CK-MB, troponin 1 and checked the amount of inotropes required, chest tube drainage, the amount of transfusion, duration of ventilator support, and duration of ICU stay. Result: The number of mean distal anastomoses was 2.8$\pm$0.9 per patient. On elevation and stabilization of the heart, systolic blood pressure was depressed and pulmonary artery pressure was elevated significantly, but during each anastomosis no significant changes were detected. The peak level of cardiac markers was 29.2$\pm$46.7 for CK-MB, 0.69$\pm$0.86 for troponin 1 on postoperative day f. Among the intraoperative hemodynamic parameters, the ischemic change of EKG and bolus injection of inotropes significantly affected the posteroperative cardiac enzymes. But, no difference other than the level of cardiac enzymes between the two groups with or without the ischemic change of EKG and bolus injection of inotropes was noticed. Conclusion: The significant hemodynamic changes occurred when the heart was elevated and stabilized, however during anastomoses there were no significant changes. Serum cardiac enzymes rose significantly in the group that showed the ischemic charge of EKG or needed the bolus injection of inotropes for maintaining hemodynamic stability intraoperatively, but it did not affect the postoperative outcome. In conclusion, the ischemic change of EKG and the need for bolus injection of intropes during operation may be very indicative for probable ischemia.

Design of an Energy Management System for On-Chip Solar Energy Harvesting (온칩 태양 에너지 하베스팅을 위한 에너지 관리 시스템 설계)

  • Jeon, Ji-Ho;Lee, Duck-Hwan;Park, Joon-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.15-21
    • /
    • 2011
  • In this paper, an energy management circuit for solar energy harvesting system is designed in $0.35{\mu}m$ CMOS technology. The solar energy management system consists of an ISC(Integrated Solar Cell), a voltage booster, and an MPPT(Maximum Power Point Tracker) control unit. The ISC generates an open circuit voltage of 0.5V and a short circuit current of $15{\mu}A$. The voltage booster provides the following circuit with a supply voltage about 1.5V. The MPPT control unit turns on the pMOS switch to provide the load with power while the ISC operates at MPP. The SEMU(Solar Energy Management Unit) area is $360{\mu}m{\times}490{\mu}m$ including pads. The ISC area is $500{\mu}m{\times}2000{\mu}m$. Experimental results show that the designed SEMU performs proper MPPT control for solar energy harvested from the ISC. The measured MPP voltage range is about 370mV∼420mV.

A 5.4Gb/s Clock and Data Recovery Circuit for Graphic DRAM Interface (그래픽 DRAM 인터페이스용 5.4Gb/s 클럭 및 데이터 복원회로)

  • Kim, Young-Ran;Kim, Kyung-Ae;Lee, Seung-Jun;Park, Sung-Min
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.2
    • /
    • pp.19-24
    • /
    • 2007
  • With recent advancement of high-speed, multi-gigabit data transmission capabilities, serial links have been more widely adopted in industry than parallel links. Since the parallel link design forces its transmitter to transmit both the data and the clock to the receiver at the same time, it leads to hardware's intricacy during high-speed data transmission, large power consumption, and high cost. Meanwhile, the serial links allows the transmitter to transmit data only with no synchronized clock information. For the purpose, clock and data recovery circuit becomes a very crucial key block. In this paper, a 5.4Gbps half-rate bang-bang CDR is designed for the applications of high-speed graphic DRAM interface. The CDR consists of a half-rate bang-bang phase detector, a current-mirror charge-pump, a 2nd-order loop filter, and a 4-stage differential ring-type VCO. The PD automatically retimes and demultiplexes the data, generating two 2.7Gb/s sequences. The proposed circuit is realized in 66㎚ CMOS process. With input pseudo-random bit sequences (PRBS) of $2^{13}-1$, the post-layout simulations show 10psRMS clock jitter and $40ps_{p-p}$ retimed data jitter characteristics, and also the power dissipation of 80mW from a single 1.8V supply.

Design of 2-Ch DC-DC Converter with Wide-Input Voltage Range of 2.9V~5.6 V for Wearable AMOLED Display (2.9V~5.6V의 넓은 입력 전압 범위를 가지는 웨어러블 AMOLED용 2-채널 DC-DC 변환기 설계)

  • Lee, Hui-Jin;Kim, Hak-Yun;Choi, Ho-Yong
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.859-866
    • /
    • 2020
  • This paper proposes a 2-ch DC-DC converter with a wide-input voltage range from 2.9V~5.6V for wearable AMOLED displays. For positive voltage VPOS, a boost converter is designed using an over-charged voltage permissible circuit (OPC) which generates a normal output voltage even if over-input voltage is applied, and a SPWM-PWM dual mode with 3-segmented power transistors to improve efficiency at light load. For negative voltage VNEG, a 0.5x regulated inverting charge pump is designed to increase power efficiency. The proposed DC-DC converter was designed using a 0.18-㎛ BCDMOS process. Simulation results show that the proposed DC-DC converter generates VPOS voltages of 4.6 V and VNEG voltage of -0.6V~-2.3V for input voltage of 2.9V to 5.6V. In addition, it has power efficiency of 49%~92%, output ripple voltage has less than 20 mV for load current range of 1 mA~70 mA.