• Title/Summary/Keyword: CR-39

Search Result 424, Processing Time 0.026 seconds

The Usefulness of the Endonasal Incisional Approach for the Treatment of Nasal Bone Fracture

  • Kim, Hyo-Seong;Suh, Hyeun-Woo;Ha, Ki-Young;Kim, Boo-Yeong;Kim, Tae-Yeon
    • Archives of Plastic Surgery
    • /
    • v.39 no.3
    • /
    • pp.209-215
    • /
    • 2012
  • Background : Among all facial fractures, nasal bone fractures are the most common, and they have been reduced by closed reduction (CR) for a long time. But several authors have reported suboptimal results when using CR, and the best method of nasal bone reduction is still being debated. We have found that indirect open reduction (IOR) through an endonasal incisional approach is a useful method for more accurate reduction of the nasal bone. Methods : A retrospective chart review was performed of 356 patients who underwent reduction of a nasal bone fracture in our department from January, 2006, to July, 2011. We treated 263 patients with IOR. We assessed patients' and doctors' satisfaction with surgical outcomes after IOR or CR. We evaluated the frequency of nasal bleeding owing to mucosal injury, and followed the surgical outcomes of patients who had simultaneous dorsal augmentation rhinoplasty. Results : According to the analysis of the satisfaction scores, both patients and doctors were significantly more satisfied in the IOR group than the CR group (P<0.05). Mucosal injury with nasal bleeding occurred much less in the IOR group (5.3%) than the CR group (12.9%). Dorsal augmentation rhinoplasty with IOR was performed simultaneously in 34 cases. Most of them (31/34) showed satisfaction with the outcomes. Conclusions : IOR enables surgeons to manipulate the bony fragment directly through the endonasal incisional approach. However, we propose that CR is the proper technique for patients under 16 and for those with comminuted nasal bone fractures because submucosal dissection in IOR can damage the growth or circulation of nasal bone.

Surface Relaxation Effect on the Magnetism of Fe Overlayer on Cr (001)

  • Kim, I.G.;Lee, J.I.;Jang, Y.R.;Hong, C.S
    • Journal of Magnetics
    • /
    • v.1 no.1
    • /
    • pp.9-13
    • /
    • 1996
  • The effects of surface relaxation on surface and interface magnetism in Fe/Cr (001) are investigated using the highly precise all-electron total-energy full-potential linearized augmented plane wave method. The Fe-Cr interlayer spacing is deter-mined by total-energy calculation and it is found to be relaxed downward by 18%. For the relaxed system, the magnetic moment of surface Fe is highly suppressed to be $1.72\mu_B$compared to the unrelaxed case ($2.39\mu_B$). This reduction of magnetic moment is considered as a result of the enhanced hybridization between Fe-d and Cr-d states, which can be seen from the calculated density of states. This work suggests the importance of effect of relaxation to the surface and interface magnetism in Fe/Cr system.

  • PDF

Deposition of $(Ti,Cr)N-MoS_2$ Thin Films by D.C Magnetron Sputtering

  • Kim S.K.;Kim J.H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.2
    • /
    • pp.70-75
    • /
    • 2006
  • As technology advances, there is a demand for development of hard, solid lubricant coating. (Ti,Cr)N-$MoS_2$, films were deposited on SKD 11 tool steel substrate by co-deposition of $MoS_2$, with (Ti,Cr)N using a D.C. magnetron sputtering process. The influence of the $N_2/Ar$ gas ratio, the deposition temperature, the amount of $MoS_2$ in the films, and the bias voltage on the mechanical and the structural properties of the films were investigated. Wear tests were performed on the films deposited in various conditions.

Study on the Surface Properties of Arc Ion Plated Ti-Al-Cr-N Thin Layers (아크 이온 증착된 Ti-Al-Cr-N 도포층의 표면 물성 연구)

  • Gang, Bo-Gyeong;Choe, Yong;Gwon, Sik-Cheol;Zang, Shi-Hong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.125-125
    • /
    • 2015
  • Ti-Al-Cr-N thin layer was prepared on Fe-Si thin sheet by arc ion plating to improve corrosion and mechanical properties. The compositions ratios of Fe : Cr : Al : Ti : Si : N of the thin layers at $500^{\circ}C$ was 1.24 : 0.56 : 36.82 : 32.72 : 0.59 : 28.07 [wt.%], respectively. The higher arc ion plating temperature was, the higher corrosion resistance and nano-hardness were observed due to chromium content. Corrosion potential and corrosion rate in artificial sea water of the coating layer were in the range of $-39mV_{SHE}$ and $2mA/cm^2$, respectively. Passivity was not observed in the artificial sea water. Nano-hardnesses of the thin layers was increased by adding Cr from 23.6 to 25.8 [GPa]. The friction coefficients and fatigue limits of the layers were 0.388, 0.031, respectively.

  • PDF

TEM Analysis of Interfaces between Cr Film Sputtered with RE Bias and Photosensitive Polyimide (RE 바이어스 스퍼터링한 Cr 박막과 감광성 폴리이미드 사이의 계면 TEM 분석)

  • 조성수;김영호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.2
    • /
    • pp.39-47
    • /
    • 2003
  • Cr thin films were deposited on photosensitive polyimide substrates by RF bias sputtering and DC sputtering and the interfaces between Cr thin film and polyimide were observed using TEM. When the polyimide surface was in-situ RF plasma cleaned at the RF power density of 0.13-2.12 $W/cm^2$, increasing of RF power density changed the morphology of polyimide surfaces from round dig to sharp shape, and surface roughness increased by anisotropic etching. The intermixed layer-like interfaces between Cr and polyimide were observed in the RF bias sputtered specimens. This interface seems to be formed due to the RF cleaning effect; the polyimide surface was RF plasma cleaned while RF power was increased to the setting point before Cr deposition.

  • PDF

Xylene Sensor Using Cr-doped Cr-Co3O4 Nanoparticles Prepared by Flame Spray Pyrolysis (화염 분무 열분해법으로 합성된 Cr-Co3O4 나노입자 자일렌 가스센서)

  • Jeong, Seong-Yong;Jo, Young-Moo;Kang, Yun Chan;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.112-117
    • /
    • 2020
  • Xylene is a hazardous volatile organic compound that should be precisely measured to monitor indoor air quality. However, the selective and sensitive detection of ppm-level xylene using oxide-semiconductor gas sensors remains a challenge. In this study, pure and Cr-doped Co3O4 nanoparticles (NPs) were prepared using flame spray pyrolysis, and their gas-sensing characteristics to 5-ppm xylene at 250 ℃ were investigated. The 4 at% Cr-doped Co3O4 NPs exhibited a high gas response to 5-ppm xylene (resistance ratio to gas and air = 39.1) and negligible cross-responses to other representative and ubiquitous indoor pollutants such as ethanol, benzene, formaldehyde, carbon monoxide, and ammonia. In this paper, the enhancement of the gas response and selectivity of Co3O4 NPs to xylene by Cr doping was discussed in relation to the catalytic promotion of the gas-sensing reaction. This sensor can be used to monitor indoor xylene.

Characteristics of TiAlCrSiN coating to improve mold life for high temperature liquid molding (고온 액상 성형용 금형 수명 향상을 위한 TiAlCrSiN 코팅의 특성)

  • Yeo, Ki-Ho;Park, Eun-Soo;Lee, Han-Chan
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.5
    • /
    • pp.285-293
    • /
    • 2021
  • High-entropy TiAlCrSiN nano-composite coating was designed to improve mold life for high temperature liquid molding. Alloy design, powder fabrication and single alloying target fabrication for the high-entropy nano-composite coating were carried out. Using the single alloying target, an arc ion plating method was applied to prepare a TiAlCrSiN nano-composite coating had a 30 nm TiAlCrSiN layers are deposited layer by layer, and form about 4 ㎛-thickness of multi-layered coating. TiAlCrSiN nano-composite coating had a high hardness of about 39.9 GPa and a low coefficient of friction of less than about 0.47 in a dry environment. In addition, there was no change in the structure of the coating after the dissolution loss test in the molten metal at a temperature of about 1100 degrees.

Characteristics of Stabilization and Adsorption of Heavy Metal (As3+, Cr6+) by Modified Activated Carbon (표면 개질 활성탄에 의한 중금속(As3+, Cr6+) 흡착 및 안정화 특성)

  • Shin, Woo-Seok;Na, Kyu-Ri;Kim, Young-Kee
    • Journal of Navigation and Port Research
    • /
    • v.39 no.3
    • /
    • pp.185-192
    • /
    • 2015
  • In this study, the adsorption efficiency of mixed heavy metals in aqueous solution was investigated using modified activated carbon. Moreover, the heavy-metal stabilization treatment of contaminated marine sediment was achieved using modified activated carbon as stabilizing agents. From the experimental results, it was shown that the adsorption equilibrium was attained after 120 mins. Heavy metal adsorption was characterized using Freundlich and Langmuir equations. The equilibrium adsorption data were fitted well to the Langmuir model in modified activated carbon. The adsorption uptake of $As^{3+}$ (28.47 mg/g) was higher than $Cr^{6+}$ (13.28 mg/g). In case of the $Cr^{6+}$, the results showed that adsorption uptake decreased with increasing pH from 6 to 10. However, adsorption of $As^{3+}$ slightly increased in the increasing change of pH. The modified activated carbon was applied for a wet-curing duration of 120 days. From the sequential extraction results, the exchangeable, carbonate, and oxides fractions of Cr and As in sediment decreased by 5.8% and 7.6%, respectively.

Screening for Mucosal Protective Effects of Various Korean Herbal Medicine Extracts in Gastroesophageal Reflux Disease (한방 추출물의 역류성 식도염 점막보호 효과에 대한 스크리닝)

  • Il-ha Jeong;Min Ju Kim;Mi-Rae Shin;Seong-Soo Roh
    • The Korea Journal of Herbology
    • /
    • v.39 no.1
    • /
    • pp.39-47
    • /
    • 2024
  • Objectives : This study evaluates how various traditional Korean herbal medicines assess MUC5AC expression for esophageal mucosal defense and analyzes the associated mechanisms involved in inflammation. Methods : Forty types of traditional Korean herbal medicines were assessed for in vitro antioxidant activities, and the real-time PCR method was employed to analyze MUC5AC expression under pH 4.5 conditions in human esophageal epithelial cells (HET-1A). Eight types of Korean herbal medicines were evaluated for in vitro antioxidant activities, and Reactive oxygen specise (ROS) expression was analyzed under bile salt (480 𝜇M) and pH 5.5 conditions in human esophageal epithelial cells (HET-1A). Simulation experiments involving bile salts and acidity were conducted for one hour to assess the efficacy of four drugs, and the activities of Mitogen-activated Protein Kinase (MEK), Nuclear Factor Kappa B (NF-𝜅B), and Cyclooxygenase-2 (COX-2) were detected through Western blot analysis. Results : Compared to the Normal group, the Control group exhibited higher ROS generation. Such increased ROS levels were significantly reduced by four extracts: Citrus Unshius Pericarpium (CUP), Cnidium officinale Rhizoma (CR), Ginseng Radix (GR), and Linderae Radix (LR). The protein expression of COX-2 decreased with the treatment of LR, CUP, and CR. Particularly, CUP and CR exhibited superior effects compared to other groups in inhibiting the phosphorylation of NF-𝜅B. Conclusion : Based on the results obtained, we have identified drugs that inhibit oxidative stress and inflammation caused by bile acid in esophageal epithelial cells. Our future plans involve comparing and analyzing the efficacy of these herbal medicines through animal experiments.

Friction and Wear Properties of Plasma-sprayed Cr2O3-MoO3Composite Coatings at Room Temperature (MoO3가 첨가된 Cr2O3플라즈마 용사코팅의 상온 마찰 마멸 특성)

  • 여인웅;안효석;임대순
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.1
    • /
    • pp.79-85
    • /
    • 2002
  • Plasma-sprayed Cr$_2$O$_3$-based coatings containing MoO$_3$were studied to gain a better understanding of the influence of MoO$_3$composition in the coatings on their tribological behaviour. A reciprocal type tribo-tester was employed to examine friction and wear behavior of the specimens at room temperature. The physical characteristics of worn surfaces were investigated by scanning electron microscopy and chemical composition of the coating surfaces was analyzed using a X-ray photoelectron spectrometer. The results showed that friction coefficient of the MoO$_3$-added coatings were lower than those without MoO$_3$addition. However pure Cr$_2$O$_3$coating showed the lowest wear loss at the self-mated test. The larger protecting layers were observed at the worn surface of plasma spray coated specimens with MoO$_3$addition. XPS analysis of the protecting layer indicated that MoO$_3$composition was dominantly formed at the surface. MoO$_3$composition in the protecting layer appears to be more favorable in reducing the friction.