• Title/Summary/Keyword: Automatic equipments

Search Result 157, Processing Time 0.027 seconds

Experimental Investigation of the Electrostatic Discharge(ESD) Damage in Packaged Semiconductor Devices (패키지 반도체소자의 ESD 손상에 대한 실험적 연구)

  • Kim, Sang-Ryull;Kim, Doo-Hyun;Kang, Dong-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.94-100
    • /
    • 2002
  • As the use of automatic handling equipment for sensitive semiconductor devices is rapidly increased, manufacturers of electronic components and equipments need to be more alert to the problem of electrostatic discharges(ESD). In order to analyze damage characteristics of semiconductor device damaged by ESD, this study adopts a new charged-device model(CDM), field-induced charged model(FCDM) simulator that is suitable for rapid, routine testing of semiconductor devices and provides a fast and inexpensive test that faithfully represents ESD hazards in plants. High voltage applied to the device under test is raised by the field of non-contacting electrodes in the FCDM simulator, which avoids premature device stressing and permits a faster test cycle. Discharge current and time are measured and calculated. The characteristics of electrostatic attenuation of domestic semiconductor devices are investigated to evaluate the ESD phenomena in the semiconductors. Also, the field charging mechanism, the device thresholds and failure modes are investigated and analyzed. The damaged devices obtained in the simulator are analyzed and evaluated by SEM. The results obtained in this paper can be used to prevent semiconductor devices form ESD hazards and be a foundation of research area and industry relevant to ESD phenomena.

Automatic Generation of MIB for Network Management (네트웍 관리를 위한 MIB의 자동생성)

  • 유재우;김영철;김성근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.6A
    • /
    • pp.848-854
    • /
    • 2000
  • Network management in TMN concerns to the operating system and communication equipments in network, and defines them as objects. GDMO(guidelines for the Definition of Managed Objects) is used to describe those objects. GDMO is not directly used for managing the network, but translated into a language with object-oriented paradigm. And GDMO refers to ASN.1(Abstract Syntax Notation One) for manage objects. This paper presents design and implementation techniques for the translator which automatically translates the specification of ASN.1 and GDMO to the object-oriented language for generating MIB(Managed object Instance Base). This system, unlike the existing source code generator, is designed to generate various object-oriented languages automatically, which are used to generate Managed object Instance Base(MIB). And the system includes various graphic user interface to enhance the development environment of ASn.1 and GDMO

  • PDF

The Fault Diagnosis using Neural Networks for Nuclear Power Plants (신경망을 이용한 원자력발전소의 주요 고장진단)

  • Kwon, Soon-Il;Lee, Jong-Kyu;Song, Chi-Kwon;Bae, Hyeon;Kim, Sung-Shin
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2723-2725
    • /
    • 2001
  • Nuclear power generations have been developed gradually since 1950. Nowadays, 440 nuclear power generations are taking charge of 16% of electric power production in the world. The most important factor to operate the nuclear power generations is safety. It is not easy way to control nuclear power generations with safety because nuclear power generations are very complicated systems. In the main control room of the nuclear power generations, about 4000 numbers of alarms and monitoring devices are equipped to handle the signals corresponding to operating equipments. Thus, operators have to deal with massive information and to grasp the situation immediately. If they could not achieve these task, then they should make big problem in the power generations Owing to too many variables, operators could be also in the uncontrolled situation. So in this paper, automatic systems to diagnose the fault are constructed using 2 steps neural networks. This diagnosis method is based on the pattern of the principal variables which could represent the type and severity of faults.

  • PDF

Implementation of User Interface for ZigBee Wireless Network (ZigBee 무선 네트워크를 위한 사용자 인터페이스의 구현)

  • Lee, Hye-rim;Kim, Yu-doo;Kang, Cheol-gyu;Oh, Chang-heon;Moon, Il-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.752-755
    • /
    • 2009
  • Recently, the production process system is largely composed automatic system using the wired network. The production process system using wired network has disadvantages that take place expense when the installed and inspected production of equipment was replaced. The each equipment happens to repair cost for control and management in production processes. In this paper, the industrial equipment that applied for IEEE 802.15.4(ZigBee) technology solves a complicated space at the plant. And then when the industrial equipments replace wired network with wireless network, this paper studied its user interface.

  • PDF

EMC Debugging Technique for Image Equipments (영상기기의 EMC Debugging 기술)

  • Song, Min-jong;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.143-148
    • /
    • 2022
  • For the purpose of treating health checkups and recovery of patients in a super-aged society, hospitals use devices designed with a reduction circuit of electromagnetic waves associated with the specific absorption rate of electromagnetic waves absorbed by the human body. In this paper, we proposed a filter improvement design method capable of reducing electromagnetic waves. As a result of confirming the validity of the proposed technique through simulation and experimental results, the following result values were obtained. Applying the common-mode (CM) inductor 4 mH to a calibration circuit, noise decreased in a multiband spectrum. Using the differential mode(DM) inductor 40 µH element in the primary calibration circuit, the noise decreased by 15 dB or more in the 3 MHz band spectrum. Also, applying the Admittance Capacitance (Y-Cap) 10 nF element in the secondary calibration circuit resulted in the decrease by more than 30 dB in the band spectrum before 2 MHz. After using a common-mode inductor 4 mH element in the tertiary calibration circuit, it decreased by more than 15 dB in the band spectrum after 2 MHz.

Automatic Nerve Activity to Physiologic Response in Adult With Psychiatric Disorder: A Systemic Review (성인 정신장애의 청각자극에 따른 생리학적 반응 측정에 대한 체계적 고찰)

  • Jung, Hye-Rim;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.9 no.1
    • /
    • pp.45-52
    • /
    • 2011
  • Objective : The aim of this study was to provide the method to measure physiologic response using equipments and auditory stimulation, and the physiologic response features of adult psychiatric disorders through a systemic review. Methods : The systemic review was executed using PubMed. The key words for search were "auditory stimulation, auditory startle, electromyograph, skin conductance, heart rate, psychiatric disorder, anxiety disorder, schizophrenia, depression". 8 studies were used for data analysis, and all of levels of evidence were level II. The substances of the review were subject(population), auditory stimulation, measure equipments and physiologic response features of psychiatric disorder. Results : 1. The subjects for the studies were anxiety disorder(4) and schizophrenia(4). 2. Auditory stimulation was used in 8 studies and visual stimulation with auditory stimulation was used in 2 studies to induce physiologic response. 3. Every study used electromyograph, and skin conductance was used in 2 studies and heart rate was used in 2 studies with electromyograph to measure physiologic response. 4. The subjects for the studies, schizophrenia and anxiety disorder(PTSD, OCD) have different physiologic response features with the normal control group. Conclusion : All studies used simple tones as an auditory stimulation and electromyograph to measure physiologic response. Psychiatric disorders indicated larger response, shorter and delayed habituation. The objective and systematic study using physiologic measure to investigate the sensory feature of psychologic disorders.

  • PDF

LAN Based MFD Interface for Integrated Operation of Radio Facilities using Fishery Vessel (어선용 무선설비의 통합운용을 위한 LAN 기반 MFD 인터페이스)

  • In-ung Ju;In-suk Kang;Jeong-yeon Kim;Seong-Real Lee;Jo-cheon Choi
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.496-503
    • /
    • 2022
  • In the reality that the fishing population is decreasing and the single-man fishing vessels is increasing, mandatory equipment for navigation and radio equipments for the safety of fishing boats has continued to be added. Therefore, many equipment such as navigation, communication and fishing are installed in the narrow steering room, so it is very confusing and a number of monitors are placed in the front, which is a factor that degrades the function of maritime observation. To solve this problem, we studied an interface that integrates and operates to major radio facilities such as very high frequency-digital selective calling equipment (VHF-DSC), automatic identification system (AIS) and fishing boat location transmission device (V-pass) into one multi function display (MFD) based on LAN. In addition, IEC61162-450 UDP packets and IEC61162 sentence were applied to exchange data through link between MFD and radio equipments, and additional messages needed for each equipment and function were defined. The integrated MFD monitor is easily operated by the menu method, and the performance of the interface was evaluated by checking the distress and emergency communication functions related to maritime safety and the message transmission status by equipment.

Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro) (국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가)

  • Oh, Yun-Jeong;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • Purpose: Recently, many hospitals have been tried to increase the satisfaction of the outpatients through blood-gathering, exam, result notice and process in a day. Each laboratory has been used the automatic equipment for the rapid requests of the result notice and the increase of the reliability and efficiency. Current automatic equipments that have been limited short TAT(Turn-Around Time)because of the restricted batch lists and 1 tip-5 detectors. The Gamma Pro which is made in Korea to improve the shortcomings of existing automation equipment, complemented with capacity to perform a wide range of domestic automation equipment. In this study, we evaluated the usefulness and reliability of short TAT by comparing Gamma Pro with current automatic equipment. Materials and Methods: We studied the correlation between Gamma Pro and RIA-mat 280 using the respective 100 specimens of low or high density to the patients who were requested the thyroid hormone test (Total T3, TSH and Free T4) in Samsung Medical Center Sep. 2009. To evaluate the split-level Gamma Pro, First, we measured accuracy and carry over on the tips. Second, the condition of optimal incubation was measured by the RPM (Revolution Per Minute) and revolution axis diameter on the incubator. For the analysis for the speed of the specimen-processing, TAT was investigated with the results in a certain time. Result: The correlation coefficients (R2) between the Gamma Pro and RIA-mat 280 showed a good correlation as T3 (0.98), TSH (0.99), FT4 (0.92). The coefficient of variation (C.V) and accuracy was 0.38 % and 98.3 % at tip 1 and 0.39 % and 98.6 % at tip 2. Carry over showed 0.80 % and 1.04% at tip 1 and tip 2, respectively. These results indicate that tips had no effect on carry over contamination. At the incubator condition, we found that the optimal condition was 1.0mm of diameter at 600RPM in 1.0mm and 1.5mm of at 500RPM or 1.0mm and 1.5 mm of diameter at 600 RPM. the Gamma Pro showed that the number of exam times were increased as maximum 20 times/day comparing to 6 times/day by current automatic equipment. These results also led to the short TAT from 4.20 hour to 2.19 hours in whole processing. Conclusion: The correlation of between the Gamma Pro and RIA-mat 280 was good and has not carry over contamination in tips. The domestic automation equipment (Gamma Pro) decreases the TAT in whole test comparing to RIA-280. These results demonstrate that Gamma Pro has a good efficiency, reliability and practical usefulness, which may contribute to the excellent skill to process the large scale specimens.

  • PDF

Real-time Environmental Radiation Monitoring System with Automatic Restoration of Backup Data in Site Detector via Communication using Radio Frequency (현장검출기에 저장된 백업데이터를 무선통신방식으로 자동 복원하는 실시간 환경선량 감시 시스템)

  • Lee, Wan-No;Kim, Eun-Han;Chung, Kun-Ho;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo;Park, Ki-Hyun;Kim, Yun-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.255-261
    • /
    • 2003
  • An environmental radiation monitoring system based on high pressurized ionization chamber has been used for on-line gamma monitoring surrounding the KAERI (Korea Atomic Energy Research Institute), which transmits the dose data measured from ion chamber on the site via radio frequency to a central processing computer and stores the transmitted real-time data. Although communication using radio frequency has several advantages such as effective and economical transmission, storage, and data process, there is one main disadvantage that data loss during transmission often happens because of unexpected communication problems. It is possible to restore the loss data by off-line such as floppy disk but the simultaneous process and display of current data as well as the backup data are very difficult in the present on-line system. In this work, a new electronic circuit board and the operation software applicable to the conventional environmental radiation monitoring system are developed and the automatical synchronization of the ion chamber unit and the central processing computer is carried out every day. This system is automatically able to restore the backup data within 34 hours without additional equipments and also display together the current data as well as the transmitted backup data after checking time flag.

The Study on Centralization & Electronic for Maintenance Efficiency of Ground Signaling System (지상신호설비의 유지보수 효율화를 위한 집중화 및 전자화 연구)

  • Baek, Jong-Hyen;Kim, Yong-Kyu;Lee, Kang-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2983-2988
    • /
    • 2010
  • The train control system used in Gyeongbu-line is classified in ATC, IXL and CTC. Domestic railway signaling systems are being developed by electrification. In these systems the electrification of interlocking reaches 57% and the safety equipments of railway crossings in trackside devices have completed their development into an integrated system. Block systems of all the existing sections have not yet electrified and integrated so that they need a number of complement in terms of construction and maintenance. For ABS currently used in existing domestic lines, and LEU being installed in Gyeongbu and Honam lines, although a train is controlled by the signaling information of the same train in the same location, the system is separately installed so that the same information is separately divided and transmitted at the each distinct system. Therefore, in the conventional ABS and LEU, there are a lot of duplicate installed compartments such as lamp detection and a power supply unit. Hence, we have a lot of problems: for maintenance, a lot of manpower and costs need to be invested and the overall manufacturing costs get higher, as well as the construction costs by duplicate. Therefore, this paper suggest design to develop an integrated electronic Block Control Unit by the integration of the currently used ABS, and communication and electronic technology. We are to monitor and manage the block systems in the corresponding station by integrating. And we are to transmit information together with LEU, which is an ATS wayside transmitter.