• Title/Summary/Keyword: Automatic Installation System

Search Result 190, Processing Time 0.021 seconds

The Construction of the Vessel Monitoring System and the Protocol Analysis for the Calling of Location Requirement Using VHF-DSC (VHF-DSC 위치요청 프로토콜 분석과 선박관제시스템 구축)

  • Kim, Jeong-Nyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2800-2805
    • /
    • 2013
  • In preperation for the compulsory installation of VHF(Very High Frequency) wireless equipment and fishing vessel automatic identification system according to the revision of "The Ships Safety Act" and "Fishing Vessel act", Fishery Information & Communication Department of National Federation of Fisheries Cooperatives is building VHF communication network and automatic identification system for fishing vessel monitoring. This study suggests the protocol analysis for the calling of location requirement using DSC(Digital Selective Calling) function and show best way for fishing vessel automatic identification system. Also, it suggest way to realize fishing vessel monitoring system.

Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage (화재피해 감소 위한 자동소화장치 적용범위 개선)

  • Baek, Chang Sun;Park, In Seon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

A Study of Automatic Fire Detection Installation based CAN Comunnication (CAN 통신기반 자동화재탐지설비에 관한 연구)

  • Kim, Young-Dong;Oh, Guem-Kon;Kang, Won-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.50-59
    • /
    • 2006
  • In this paper, We are going to propose the fire protection system using CAN(Controller Area Network). The larger, higher and deeper buildings an, the more dangerous people are when fire happens. We should be aware of the problems of prior fire protection system. Therefore, we construct the embedded system based on CAN communication that is capable of N to N communication, and build independent fire protection system. If the fire is occurred on the building, the problem is that how fast we can detect the fire and put it on by using available system, this is major factor that reduces damage of our wealth. Therefore in this studies, We would like to design more stable system than current system. This system is based on CAN communication which is available N to N communication constructs and designed to compensate for each fault, so that our aim is to reduce the wires of system, cost of installation and to suppose future type fire protection system.

Measurement of Electrical Treeing Length and Area by Use of Image Processing (영상 처리 방법을 이용한 트리 길이와 열화면적 계측)

  • 백관현;김재환
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.57-62
    • /
    • 1994
  • In this paper, a system for measuring of treeing degradation in organic dielectric material by using image processing technics, is discussed. Traditionally, treeing is measured by visual method. It made difficulty to understanding for features and changes in the configlEation of the tree growth. Using image processing system, it is made to describe the characters of the tree growth, specially length of tree and area of treeing degradation. From this image processing and visual measurement, the similar results were made, an automatic measurement system was made for configuration of the tree growth.

  • PDF

Electric power system effect investigation of large size digital signal accident thought in digital age (디지털시대의 대형사고의 전기적 영향 고찰)

  • Kang, Tae-Keun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.575-580
    • /
    • 2004
  • The latest equipment automatic Intelligence of digital base done large size equipment appear in succession. That run by voltage electric current(mA, mV, ${\mu}A,\;{\mu}V$) that outline is microscopic of action of accuracy large size equipment of this digital base is bulk. Have received influence that is great in river electric field by installment that use computer. Most of domestic working voltage from service entrance extra-high voltage and working voltage of commercial frequency 60Hz working voltage 220V that use our country outside 1 country in interior of 22.900V for semiconductor use computer use digital installment of appliance as well as various smalls of digital base, middle, large size that safety is these fine voltage electric current that is not enough direct admonition hundred vast damage give can. Also, already act in surge circle and impulse transient phenomena such as several thousands, myriads, strong bit error more than billions time to digital fine electronic circuit by mistake use of using electric facility system of system electric power.

  • PDF

A study on the Development and Application of a Steam Generator Level Digital Control System for Nuclear Plants (원자력발전소의 증기발생기 수위 디지털 제어 시스템 개발 및 적용에 관한 연구)

  • 문병희;김경철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.101-109
    • /
    • 2002
  • It is a very difficult to control the S/G(Steam Generator) levels for not only automatic operation mode but also manual operation made by operators in case of start up or low power plants. The object of this study is to develop and applicate a DCS(Digital Control System) that process the reliable control algorithm in order to control S/G levels automatically from a start-up to full power operation mode for nuclear power plants.

Implementation of Aeronautical Surveillance Transceiver using AIS based on ADS-B Concepts (선박자동식별장치를 이용한 ADS-B 개념 기반의 항공감시용 송수신기의 구현)

  • Song, Jae-Hoon;Oh, Kyung-Ryoon;Kim, Jong-Chul;Lee, Jang-Yeon
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.685-690
    • /
    • 2009
  • International Maritime Organization (IMO) recommends the installation of an Automatic Identification System (AIS) according to requirements by SOLAS to avoid maritime collision. AIS provides traffic information of other ships that may be used for maritime traffic control, SAR (Search and Rescue) and collision avoidance to apply safety management. In this paper, preliminary results to implement an aeronautical surveillance transceiver using AIS transceiver based on ADS-B concepts are described. Although altitude information is not required for AIS since the AIS is operated at MSL (Mean Sea Level), altitude information can be extracted by a GPS (Global Positioning System) chip-set in the AIS transceiver. ADS-B transceiver is implemented by defining a surveillance message format including the altitude information and modifying SOTDMA (Self-Organizing Time Division Multiple Access) protocol. Ground tests and flight tests are performed to validate the implementation results.

A Development of Energy Saving System for Automatic Lighting Control using PIR (PIR을 이용한 에너지절감형 자동조명제어 시스템 개발)

  • Joo, Jin-Hwan;Kang, Shin-Wook;Kwon, Hak-Cheol;Lee, Suk-Gyu;Park, Ju-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.58-68
    • /
    • 2010
  • This paper proposes a novel design of auto light control system with high efficiency using RS-485 to save lighting energy in new and existing buildings. The proposed system consists of ALSU(Auto Light Sensor Unit) which is connected with RS-485 to control lighting appliances, ALS(Auto Light Unit), and Hi-FACS which is a monitoring system using communication interface. lighting appliances are automatically controlled by ALSU which detects moving objects. The total system is designed to be controlled by either manual or auto mode by using the ALS. In addition, the monitoring system receives the information on the state of the lighting appliances from ALSU and ALS to control the proposed system We compared the proposed system with the conventional one in functionality and energy saving point of view. Through some experimental results, the proposed system shows better performance in various circumstances.

A Middleware Framework for an Automatic Deployment of a Grid Computing Environment (그리드 컴퓨팅 환경을 자동으로 구축하는 미들웨어 프레임워크)

  • Lee, Jin-Bock;Choi, Jae-Young
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.4
    • /
    • pp.255-259
    • /
    • 2009
  • In this paper, we present AGE(Automatic Grid Environments), which is a middleware system in which Grid resources can automatically participate in a Grid environment. While other existing systems need the configuration of each Grid node to deploy a Grid environment, AGE offers automatic installation and execution of necessary middleware for participating in a Grid environment. And Grid applications in AGE do not need to be pre-installed and pre-configured. When an application is to be executed in participating Grid nodes, this system can download, install, and execute the application automatically. Therefore, AGE provides users with convenience such as deploying a Grid environment, executing the application, and releasing nodes or resources from the Grid environment automatically.

A Simple intelligence control method for actuator of an automatic installation with the unknown system modelling (시스템 모델링이 불확실한 자동화 설비용 액츄에디터를 위한 간단한 지능제어 방식)

  • 손동설;이용구;엄기환
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.81-91
    • /
    • 1997
  • 본 논문에서는 시스템 모델링이 어렵과 복잡한 자동화 설비를 위한 간단한 지능제어방식을 제안하나. 제안된 방식은 시스템 모델링이 불확실한 시스템에 대하여 입력신호와 직접관계되지 않은 비선형 함수의 동정은 퍼지-신경회로망을 이용하고, 입력신호와 관계되는 비선형 함수는 동정을 하지 않고 임의의 양의 실수로 놓으므로 기존의 전체함수 동정보다 적은량으로 동정할 수 있고, 동정된 정보를 이용하여 비선형 제어기를 설계하는 간단한 제어방식이다. 제안된 제어 방식의 유용성을 확인하기 위하여 자동화 설비에 액츄에이터로 많이 사용되는 직류 서보전동기를 이용한 역진자 시스템에 적용하여 시뮬레이션 및 실험을 하고, 제안된 제어방식을 기존의 신경회로망 제어방식과 제어성능을 비교 검토한다.

  • PDF