• 제목/요약/키워드: Array chip

검색결과 529건 처리시간 0.025초

직교배열법에 의한 칩절단특성 예측 (Pridiction of chip breakability by an orthogonal array method)

  • 이영문;양승한;권오진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.1008-1011
    • /
    • 2001
  • The purpose of this paper is to evaluate the chip breakability during turning using the experimental equation, which is developed by an orthogonal array method. The chip breaking index(CB), non-dimensional parameter is used in the evaluation of chip breakability. The analysis of variance(ANOVA)-test has been used to check the significance of cutting parameters. And using the result of ANOVA-test, the experimental equation of chip breakability, which consists of significant cutting parameters, has been developed.

  • PDF

언더필 기술 (Underfill Technology)

    • 한국표면공학회지
    • /
    • 제36권2호
    • /
    • pp.214-225
    • /
    • 2003
  • Trends in microelectronics packages such as low cost, miniaturization, high performance, and high reliability made area array interconnecting technologies including flip chip, CSP (Chip Scale Package) and BGA (Ball Grid Array) mainstream technologies. Underfill technology is used for the reliability of the area array technologies, thus electronics packaging industry regards it as very important technology In this paper, the underfill technology is reviewed and the recent advances in the underfill technology including new processes and materials are introduced. These includes reworkable underfills, no-flow underfills, molded underfills and wafer - level - applied underfills.

Indicator-free DNA Chip Array Using an Electrochemical System

  • Park, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권4호
    • /
    • pp.133-136
    • /
    • 2004
  • This research aims to develop a DNA chip array without an indicator. We fabricated a microelectrode array through photolithography technology. Several DNA probes were immobilized on an electrode. Then, target DNA was hybridized and measured electrochemically. Cyclic-voltammograms (CVs) showed a difference between the DNA probe and mismatched DNA in an anodic peak. This indicator-free DNA chip resulted in a sequence-specific detection of the target DNA.

Recent Development of Protein Microarray and Proteogen Platform

  • Han, Moon-Hi;Kang, In-Cheol;Lee, Yoon-Suk;Cho, Yong-Wan;Lee, Eun-Kyoung
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.47-47
    • /
    • 2005
  • There are many different surface technologies currently applied for preparation of protein chips. However, it requires innovative surface chemistry for capture proteins to be immobilized on chip surface keeping their conformation and activity intact and their orientation right, while they bind tightly and densely in a given array spot. Proteogen has developed 'ProteoChip BP' coated with novel proprietary linker molecules $(ProLinker^{TM})$ for efficient and robust immobilizations of capture proteins by improving surface properties of molecular captures. It was demonstrated that $ProLinker^{TM}$ gave the best surface performance in preparation of protein microarray chip base plates among others currently available on the market. In particular, the $ProLinker^{TM}-based$ surface chemistry has demonstrated to provide excellent performance in preparation of 'Antibody Chip' for analysis of biomarkers as well as proteome expression profiles. The linker molecule has also shown to be well applicable for development of biosensors and micro-beads as well as protein microarray and nano-array. ProteoChip BP can be used either for preparation of high-density array by using a microarrayer or for preparation of 'Well-on-a-Chip' with low density array, which is better applicable for quantitative analysis of biomarkers or protein-protein interactions. The biomarker assay can be performed either by direct or sandwich methods of fluorescence immunoassay. Application of ProteoChip BP has been well demonstrated by the extensive studies of 1) tumor-marker assays, 2) new drug screening by using 'Integrin Chip' and 3) protein expression profile analysis. Some of experimental results will be presented.

  • PDF

플립칩의 매개변수 변화에 따른 보드레벨의 동적신뢰성평가 (Dynamic Reliability of Board Level by Changing the Design Parameters of Flip Chips)

  • 김성걸;임은모
    • 한국생산제조학회지
    • /
    • 제20권5호
    • /
    • pp.559-563
    • /
    • 2011
  • Drop impact reliability assessment of solder joints on the flip chip is one of the critical issues for micro system packaging. Our previous researches have been showing that new solder ball compositions of Sn-3.0Ag-0.5Cu has better mechanical reliability than Sn-1.0Ag-0.5Cu. In this paper, dynamic reliability analysis using Finite Element Analysis (FEA) is carried out to assess the factors affecting flip chip in drop simulation. The design parameters are size and thickness of chip, and size, pitch and array of solder ball with composition of Sn1.0Ag0.5Cu. The board systems by JEDEC standard including 15 chips, solder balls and PCB are modeled with various design parameter combinations, and through these simulations, maximum yield stress and strain at each chip are shown at the solder balls. It is found that larger chip size, smaller chip array, smaller ball diameter, larger pitch, and larger chip thickness have bad effect on maximum yield stress and strain at solder ball of each chip.

Design of a New ISFET Array Chip

  • Yeow, Terence;Seo, Hwa-Il;Mulcahy, Dennis;Haskard, Malcolm
    • 센서학회지
    • /
    • 제4권4호
    • /
    • pp.55-61
    • /
    • 1995
  • 가변 입력전압을 이용하여 ISFET의 문턱전압을 검출하는 새로운 개념의 ISFET array chip을 설계하였다. 설계된 칩은 240개의 pH-ISFET와 신호처리회로를 포함하며, 증가된 신뢰성 및 정확성, 디지탈 출력 그리고 멀티센서로의 응용성 등의 특성을 가진다. 칩제조를 위해 CMOS 공정을 응용한 새로운 공정을 설계하였고 칩을 layout 하였다.

  • PDF

8.2-GHz band radar RFICs for an 8 × 8 phased-array FMCW receiver developed with 65-nm CMOS technology

  • Han, Seon-Ho;Koo, Bon-Tae
    • ETRI Journal
    • /
    • 제42권6호
    • /
    • pp.943-950
    • /
    • 2020
  • We propose 8.2-GHz band radar RFICs for an 8 × 8 phased-array frequency-modulated continuous-wave receiver developed using 65-nm CMOS technology. This receiver panel is constructed using a multichip solution comprising fabricated 2 × 2 low-noise amplifier phase-shifter (LNA-PS) chips and a 4ch RX front-end chip. The LNA-PS chip has a novel phase-shifter circuit for low-voltage operation, novel active single-to-differential/differential-to-single circuits, and a current-mode combiner to utilize a small area. The LNA-PS chip shows a power gain range of 5 dB to 20 dB per channel with gain control and a single-channel NF of 6.4 dB at maximum gain. The measured result of the chip shows 6-bit phase states with a 0.35° RMS phase error. The input P1 dB of the chip is approximately -27.5 dBm at high gain and is enough to cover the highest input power from the TX-to-RX leakage in the radar system. The gain range of the 4ch RX front-end chip is 9 dB to 30 dB per channel. The LNA-PS chip consumes 82 mA, and the 4ch RX front-end chip consumes 97 mA from a 1.2 V supply voltage. The chip sizes of the 2 × 2 LNA-PS and the 4ch RX front end are 2.39 mm × 1.3 mm and 2.42 mm × 1.62 mm, respectively.

Hybridization by an Electrical Force and Electrochemical Genome Detection Using an Indicator-free DNA on a Microelectrode-array DNA Chip

  • Choi, Yong-Sung;Lee, Kyung-Sup;Park, Dae-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권3호
    • /
    • pp.379-383
    • /
    • 2005
  • This research aims to develop DNA chip array without an indicator. We fabricated microelectrode array by photolithography technology. Several DNA probes were immobilized on an electrode. Then, indicator-free target DNA was hybridized by an electrical force and measured electrochemically. Cyclic-voltammograms (CVs) showed a difference between DNA probe and mismatched DNA in an anodic peak. Immobilization of probe DNA and hybridization of target DNA could be confirmed by fluorescent. This indicator-free DNA chip microarray resulted in the sequence-specific detection of the target DNA quantitatively ranging from $10^{-18}\;M\;to\;10^{-5}$ M in the buffer solution. This indicator-free DNA chip resulted in a sequence-specific detection of the target DNA.

직교배열법에 의한 선삭가공시 칩절단성 평가 (Chip breakability evaluation in turning by an orthogonal array method)

  • 배병중;박태준;양승한;이영문
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 추계학술대회논문집 - 한국공작기계학회
    • /
    • pp.279-284
    • /
    • 2000
  • The object of this paper is to evaluate the chip breakability using the experimental equation of surface roughness, which is developed in turning by an orthogonal array method. L$\sub$9/(3$^4$) orthogonal array method, one of fractional factorial design has been used to study effects of main cutting parameters such as cutting speed, feed rate and depth of cut, on the surface roughness. The evaluation of chip breakability is used the chip breaking index(C$\sub$B/), non-dimensional parameter. And the analysis of variance (ANOYA)-test has been used to check the significance of cutting parameters. Using the result of ANOYA-test, the experimental equation of chip breakability, which consists of significant cutting parameters, has been developed. The coefficient of determination of this equation is 0.866.

  • PDF

Analysis of Breath from Diabetic Patients Based on a One-chip-type Sensor Array

  • Yu, Joon-Boo;Jang, Byoung Kuk;Byun, Hyung-Gi
    • 센서학회지
    • /
    • 제28권4호
    • /
    • pp.221-224
    • /
    • 2019
  • Based on the results of studies on acetone excretion in diabetic patients, a one - chip sensors array was fabricated by combining acetone-selective sensor materials and volatile-organic-compound sensitive sensor materials. An electonic-nose was implemented using a sensor array and confirmed selectivity for five gases. In this system, the excretion of diabetic patients and controls was sampled with solid phase microextraction fiber and transferred to the sensor array. Although the control and diabetic patients were distinct, several samples failed. In the control group, the results of blood tests were normal, but patients were highly obese. In addition, the gas chromatography mass spectrometry results for the subjects revealed chemicals that are external factors.