• Title/Summary/Keyword: 표준측정법

Search Result 871, Processing Time 0.026 seconds

A Study on Temperature Properties Analysis for Tension Measurement of Steel Cables Using Magnetic Sensor (자기센서에 의한 강재 케이블 장력측정에서 온도특성에 대한 연구)

  • Park, Hae-won;Ahn, Bong-young;Lee, Seung-seok;Park, Jeong-hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.181-188
    • /
    • 2009
  • Measuring the tensile strength of steel cables used to support bridges is a critical inspection item in terms of the safety of a bridge. Today, cable tension is measured with the vibration method and loadcell. Recently, some advanced countries have conducted studies on measuring tension with magnetic method and are suggesting prospective results. Since there were no such studies ongoing in Korea, we began a study on measuring tension with magnetic method as we are undergoing researches to improve the precision of measurements. It is necessary to consider the influence for the magnetic field and the temperature of steel cables in tension measurement of magnetic method. In this paper, we tested an output characteristic of tension sensor according to temperature and deduced temperature compensation coefficient in the given magnetic field and applied the compensation coefficient to the tension measurement system in the lab. We analyzed and evaluated testing results for the output voltages of the tension sensor according to cable tensions.

Development of Calibration System of Helium Permeation Type Standard Leaks (헬륨 투과형 표준리크 교정장치 개발)

  • Hong S.S.;Lim I.T.;Shin Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.347-353
    • /
    • 2006
  • A helium permeation type standard leak calibration system has newly developed by using dynamic gas expansion method. The measurement range was extended lower to $10^{-6}$ Pa L/s for participating CCM (Consultative Committee for Mass and Related Quantities) standard leak key comparison. For the system, pressure ratios of high and ultra-high vacuum chamber and porous plug conductance for helium gas were determined. By using the system, a permeation type standard leak of $5.6{\times}10^{-4}$ Pa L/s range was calibrated. The calibration result showed that the difference between standard commercial leak was 11.1 %.

Uncertainty Analysis of Spinning Rotor Gauge Calibrated by High Vacuum Standard of Static Expansion Method (정적법 고진공표준기에 의해 교정한 스피닝 로터 게이지 불확도 평가)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.186-194
    • /
    • 2005
  • A Spinning Rotor Gauge was calibrated between $4.04\times10^{-3}$ Pa and $1.11\times10^{-2}$ Pa at the high vacuum standard by static expansion method. The results were analysed according to the document of 'Guide to the Expression of Uncertainty in Measurement' of ISO. The expanded uncertainty was $3.0035\times10^{-3}$ Pa at $7.5448\times10^{-3}$ Pa. $95\%$ confidence level, and coverage factor of k = 1.

Studies on Scintillation Proximity Assay for the mesurement of alpha-hCG (Alpha-hCG 측정을 위한 섬광 근접 측정법 (Scintillation Proximity Assay)에 관한 연구)

  • Choi, Tae-Hyun;Lim, Sang-Moo;Choi, Chang-Woon;Chung, Wee-Sup;Lim, Soo-Jeong;Lee, Su-Jin;Lee, Tae-Sup;Awh, Ok-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.2
    • /
    • pp.133-139
    • /
    • 2002
  • Purpose: Scintillation Proximity Assay (SPA) does not require the physical separation of receptor bound form from free form. SPA was applied to the study of interaction of human chorionic gonadotropin (hCG) and $anti-{\alpha}$ hCG in serum. Materials and methods: $Anti-{\alpha}$ hCG was biotinylated for the binding to streptavidin. The assay was based on the simple competitive binding method between $[^{125}I]hCG$ and the hCG in sample serum, with $anti-{\alpha}$ hCG-coated beads. Aliquots of biotinylated $anti-{\alpha}$ hCG were dispensed into scintillation vials containing $100{\mu}{\ell}\;[^125}I]hCG\;and\;200{\mu}{\ell}$ of either a standard concentration of hCG for preparation of standard curve or unknown sample, and incubated for 20 min. at room temperature. Then $20{\mu}{\ell}$ streptavidin-coated beads were added to vials, and finally incubated for 10 min at room temperature. Values for unknown samples were then calculated from the standard curve. Results: Optimal background counts were certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result from SPA assay was similar to that of RIA. Conclusion: This observation confirms that SPA method could be useful for clinical diagnosis.

Analysis on the Induction Effects by Separation Distance between the Power Feeding Station and the Telecommunication Cables (3점 전위강하법과 2극 측정법에 대한 접지저항 측정 결과 분석)

  • Choi, Mun-hwan;Lee, Snag-mu;Cho, Pyung-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.577-580
    • /
    • 2012
  • RRA Notification No.2010-36 suggests the 3-point method(fall-of-Potential) using 2 auxiliary poles only as a test method of earth resistance. However this method needs to much space to install auxiliary poles so it is very difficult to measure the earth resistance in spots such as a mountain district, rocky district. So, we have analyzed the methods of 2-point method and loop resistance method in IEEE std. 81 and ITU-handbook(Earthing and Bonding) and applied these methods in test bed with 3-point method. In this paper we have compared and analyzed the earth resistance value using these 3 methods.

  • PDF

An Experimental Study on the Compressive Strength of Reinforcing Bars in Concrete Specimens and Compressive Strength Measurement Methods (콘크리트 압축강도 측정법과 공시체 내 철근이 압축강도 측정에 미치는 실험적 연구)

  • Lee, Won-Hong;Choi, Sang-Gi;Lee, Seuong-Yeol;Ahn, Jin-Hee;Kang, Beom-Ju
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.33-40
    • /
    • 2021
  • Measuring the compressive strength of concrete is a very important factor in the safety review of concrete structures. Concrete compressive strength measurement methods include destructive and non-destructive methods. The destructive method includes the uniaxial compression failure method, and the non-destructive method includes the rebound hardness method and the elastic wave measurement method. In this study, the type of measurement method and the effect of reinforcing bars inside the concrete were tested to examine the relationship between them. Regardless of the type of specimen, the average compressive strength by the elastic wave measurement method among the three experimental methods was greater than the average compressive strength by the other methods. When the specimen type is the same, the standard deviation of the measured values of the elastic wave measurement method is smaller than that of the other measurement methods, so it can be seen that the elastic wave measurement method does not show large variance in the measured values compared to the other two measurement methods. When the average compressive strength according to the test method for each specimen was compared with the average compressive strength of the compressive failure test method, the average compressive strength was measured to be high in the order of the elastic wave measurement method, the compression failure test, and the rebound hardness method. Since the measured values of the compressive strength of concrete are different depending on the method of measuring the compressive strength of concrete and the presence or absence of reinforcing bars inside the concrete, further research is required considering the effect of various concrete covers.

Development of certified reference materials for odorous aldehyde (알데하이드 악취물질의 인증표준물질 개발)

  • Kim, Young-Doo;Woo, Jin-Chun;Bae, Hyun-Kil;Kim, Byoung-Moon;Lee, Byung Gil;Heo, Gwi Suk
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.14-19
    • /
    • 2008
  • Among the many odor materials, aldehyde has bad influences not only on human nose, but also on human health. Aldehyde has a strong odor at infinitesimal level, such as down to ppt concentration. Also aldehydes are highly reactive and have poor stability. Therefore, manufacture of standard gases, analysis of aldehydes are very difficult compare to other air pollution analysis. Aldehyde CRM containing 4 different aldehydes at $10{\mu}mol/mol$ (ppm) is developed by using gravimetry method according to ISO 6142 guide. The standard gases were reproduced again, and examined its reproducibility of preparation by GC-FID. The developed aldehyde CRM's certified value showed a relative expanded uncertainties of 2.11 % (95 % of confidence level, k=2).

Standard Field Generation Using a Micro-TEM Cell and Its Measurement Uncertainty Evaluation (Micro-TEM Cell을 사용한 표준 전자기장의 발생 및 측정불확도 평가)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Ung-Taek;Kang, No-Weon;Kang, Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2009
  • In this paper, a standard field generation method using a micro-TEM ceil is described and its measurement uncertainty is evaluated. The standard field generation system consists of an auto-leveling signal source, a micro-TEM cell operating up to 1.2 GHz, and a power measuring Instrument using a thermistor mount. Measurement results of a field strength key comparison (CCEM.RF-K20) for the field strength of 20 V/m at frequencies between 10 MHz and 1 GHz are presented for validating the standard field generation method.

Review of the Regulations and Standard Specifications for the Low Power Radio Frequency Devices between korea and USA (한.미 소출력 무선기기 관련제도 및 표준규격 조사분석)

  • Koo, B.H.;Jang, W.H.
    • Electronics and Telecommunications Trends
    • /
    • v.9 no.4
    • /
    • pp.113-129
    • /
    • 1994
  • 우리나라에서는 전파법 시행령 제56조의 2항과 무선 설비 규격 제4절 및 관련 고시를 통하여 소출력 무선 설비들을 규정하고 있으나 대상 설비 중 극히 일부분만 세부적인 기술 기준이 설정되어 있는 실정이다. 따라서 이러한 소출력 무선기기 상호간의 혼신이나 타 기기와의 간섭으로 인하여 전파 질서의 안정에 위협받을 가능성이 있다. 본 고에서는 이와 같은 문제를 최소화하기 위해 미국의 소출력 무선기기에 대한 제도 및 표준 규격을 조사 조사분석하여 우리나라와 비교함으로써 국내 무선기기 관련 제도의 체계적 정립과 소출력 무선 설비의 형식 검정을 위한 표준 측정법의 정립에 기여하고자 한다.

Precise Impedance Measurement of Coaxial Loads using Air Line Impedance Standards (Air Line 임피던스 표준을 이용한 동축형 부하의 임피던스 정밀 측정)

  • 강진섭;김정환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.788-795
    • /
    • 2000
  • In this paper, a method for the precise impedance measurement of coaxial loads using an offset open and short as the reflection standards and reference air lines with different lengths as the impedance standards is proposed. Measured input impedances of power sensors and thermistor mounts obtained from SWR bridges(5~400MHz) and a vector network analyzer(100~1,000MHz) are presented in the frequency range of 5MHz to 1,000 MHz.

  • PDF