A Study on Temperature Properties Analysis for Tension Measurement of Steel Cables Using Magnetic Sensor

자기센서에 의한 강재 케이블 장력측정에서 온도특성에 대한 연구

  • Received : 2008.08.01
  • Accepted : 2009.01.07
  • Published : 2009.03.30

Abstract

Measuring the tensile strength of steel cables used to support bridges is a critical inspection item in terms of the safety of a bridge. Today, cable tension is measured with the vibration method and loadcell. Recently, some advanced countries have conducted studies on measuring tension with magnetic method and are suggesting prospective results. Since there were no such studies ongoing in Korea, we began a study on measuring tension with magnetic method as we are undergoing researches to improve the precision of measurements. It is necessary to consider the influence for the magnetic field and the temperature of steel cables in tension measurement of magnetic method. In this paper, we tested an output characteristic of tension sensor according to temperature and deduced temperature compensation coefficient in the given magnetic field and applied the compensation coefficient to the tension measurement system in the lab. We analyzed and evaluated testing results for the output voltages of the tension sensor according to cable tensions.

교량 지지용으로 사용되는 강재 케이블에 대한 장력측정은 교량 안전관리의 중요한 측정항목이다. 현재 케이블에 걸린 장력을 진동법과 로드셀로 측정하고 있으며, 최근에는 선진국에서 자기적 방식에 의한 장력측정 방법을 연구하여 이에 대해 여러 가지 결과물을 제공하고 있다. 그러나 아직 우리나라에서는 이에 대한 체계적인 연구가 수행되지 않고 있어 자기적 방식에 의한 장력측정 연구를 시작하였으며 장력측정 정밀도 향상을 위해 연구하고 있다. 자기적 방식의 장력측정에서 강재 케이블 내의 온도와 자기장에 대한 영향을 검토해야 한다. 금번 논문에서는 온도에 따라 장력센서의 출력특성을 시험하였고 주어진 자기장에서 온도보정계수를 도출하였으며 시험실 내의 장력측정 시스템에 보정계수를 적용하여 케이블 장력에 따른 장력센서의 출력특성에 대한 시험 결과를 분석하고 평가하였다.

Keywords

References

  1. 김창석 외, 전기/자기의 측정과 표준, KSRI-ET-72, 한국표준과학연구원, 1985
  2. 김창석 외, 자기 측정 및 시험, KSRI-ET-33-1, 한국표준과학연구원, 1987
  3. 박병우 외, 전자기학, 교보문고, 2000
  4. B.D. Cullity, Introduction to Magnetic Materials, Addison-Wesley Publishing Company, 1972, pp. 327-375
  5. Park, Haewon, Ahn, Bongyoung, Lee Seung seok and Kim, Jongwoo "Development of Magnetic Sensor for Measurement of the Cable Tension of Large Scale Bridge" Journal of the Korean Society for Nondestructive Testing Vol. 27, No. 4, 2007. 8, pp. 339-344
  6. Russel, J. C., Lardner, T. J., "Expremental Dertermination of Frequence and Tension for Elastic Cable," ASCE Journal of Engineering Mechanics, Vol. 124, No. 10, 1998, pp. 1067-1072 https://doi.org/10.1061/(ASCE)0733-9399(1998)124:10(1067)
  7. Wang, M. L., "Health Assessment and Monitoring of Long Span Concrete Segmental Bridge Bridge Research Center in University of Illinois at Chicago," presented in a seminar in the Safety Metrology Group of the Korea Research Institute of Standards and Science, 2001
  8. Zui, H. Shinke, T. Namita, Y., "Practical Formulas for Estimation of Cable Tension by Vibration Method," Journal of Structural Engineering., Vol. 122, Issue 6, 1996, pp. 651-656 https://doi.org/10.1061/(ASCE)0733-9445(1996)122:6(651)