• 제목/요약/키워드: 측정잡음

Search Result 1,744, Processing Time 0.027 seconds

Implementation of Low Noise Current Sensor using Low Pass FIR Filter (저역통과 FIR필터를 이용한 저잡음 전류 센서 구현)

  • Kim, Jeong-Hwan;Lee, Seong-Jin;Choi, Yong-geon;Han, Seong-Gye;Kwon, Se-Ik;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.499-502
    • /
    • 2017
  • The needs of efficient electricity use and current measurement for electrical safety have been increased. Hence, the current sensor is used, especially non-contact current sensor which can measure the current without blocking the circuit using hall effect. However, the accurate measuring of the current sensor is inhibited due to the inflow of various noises in this current sensor. In this article, a stronger current sensor against the noise is proposed using low pass FIR filter to the existing current sensor. FIR filter was designed to block the range over the certain frequency at the output of the current sensor to eliminate the external noises, and so on. As a result, more accurate and close measurements were possible.

  • PDF

The Analysis of The Kalman Filter Noise Factor on The Inverted Pendulum (도립진자 모델에서 칼만 필터의 잡음인자 해석)

  • Kim, Hoon-Hak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.5
    • /
    • pp.13-21
    • /
    • 2010
  • The Optimal results of Kalman Filtering on the Inverted Pendulum System requires an effective factor such as the noise covariance matrix Q, the measurement noise covariance matrix R and the initial error covariance matrix $P_0$. We present a special case where the optimality of the filter is not destroyed and not sensitive to scaling of these covariance matrix because these factors are unknown or are known only approximately in the practical situation. Moreover, the error covariance matrices issued by this method predict errors in the state estimate consistent with the scaled covariance matrices and not the issued state estimates. Various results using the scalar gain $\delta$ are derived to described the relations among the three covariance matrices, Kalman Gain and the error covariance matrices. This paper is described as follows: Section III a brief overview of the Inverted Pendulum system. Section IV deals with the mathematical dynamic model of the system used for the computer simulation. Section V presents a various simulation results using the scalar gain.

Optimization of Exposure Parameters in Brain Computed Tomography (두부 전산화단층촬영에서 노출 파라미터의 최적화)

  • Ko, Seong-Jin;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.355-362
    • /
    • 2010
  • This study determines a range of CT parameter values in Brain CT which are minimizing patient absorption dose without compromising the image quality and optimal exposure condition. We measured dose and image noise using conventional CT parameters in Brain CT. In additon, we evaluated dose, SNR and PSNR of head phantom images while changing kVp and rotation time. In this study, effectiveness of dose that was achieved from dose reproducible experiments in conventional head CT condition is determined by changing kVp and rotation time. Dose and PSNR is related to low dose-high resolution condition. In conclusion, we suggest that using proposed conditions is effective for imaging to compare with conditions proposed by the manufacturer.

A Simple Optical Signal to Noise Ratio Monitoring Technique for OADM (광섬유 브래그 격자를 이용한 광 분기 결합기의 광신호 대 잡음비 측정방법)

  • Youn, Ji-Wook;Park, Heuk;Kim, Kwang-Joon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.10
    • /
    • pp.43-47
    • /
    • 2002
  • A simple optical signal to noise ratio monitoring method using fiber Bragg grating is proposed for monitoring performance of OADM. OSNR of each channel is determined by monitoring the optical power transmitted and reflected from fiber Bragg gratings, simultaneously. We have obtained OSNR with accuracy better than 0.8㏈ compared with OSA of 0.1nm optical resolution in the wide input power range between -6 ㏈m and -23㏈m per channel.

Detection the Biomedical Information using the Piezo Film Sensor (Piezo Film Sensor를 이용한 생체 정보 검출)

  • Lee, H.W.;Seo, H.;Jeong, W.G.;Jang, D.B.;Lee, G.K.
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 2010
  • For the ubiquitous healthcare environment, real-time measurement of biomedical signals and accuracy of the measured biomedical information are very important. In addition, it is important to develop a healthcare device with low power In this paper, the synchronized pulse in a heartbeat was detected from the radial artery using the piezo film sensor, in order to eliminate inconvenience to wear a pulse detection finger probe. We can get a best output after applying the adaptive noise canceller using two piezo film sensor signals, pulse signal having motion artifacts and motion artifacts reference signal. To detect heartbeat, we use maximum point detection method from pulse removed motion artifacts.

  • PDF

Time Domain Modal Identification Method by using Measured Signals and its Sensitivity to Measurement Noise (측정치를 이용한 시간영역 모우드 특성 규명 기법 및 잡음에 대한 민감도 분석)

  • Choi, Hyung Jin;Lee, Hak Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.1 s.44
    • /
    • pp.83-91
    • /
    • 2000
  • The first Procedure to identify structural system by using measured data is transformation of data to frequency domain and try to recognize modal characteristics in graphical condition. Those methods are doubted about the reliability to the civil structures, especially bridges which has coupled and close modal characteristics. In this paper, feasibility of time domain modal Identification methods were examined and applied double least square method to overcome bias characteristics of the identification methods. To show the advantage of proposed method, simulation were carried out for mass-spring model. And to examine the usage of the method in realistic case, sensitivity of the methods to noise was performed.

  • PDF

The Noise Influence of 4G Mobile Transmitter on Audio Devices (4G 휴대 단말기 송신에 의한 오디오 잡음 영향)

  • Yun, Hye-Ju;Lee, Il-Kyoo
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.1
    • /
    • pp.31-34
    • /
    • 2013
  • This paper deals with the interfering audio noise caused by LTE(Long Term Evolution) UE(User Equipment) which is 4th generation mobile communications on audio devices. At first, we realized that the interfering signal of the LTE UE is determined by the transmit power of the LTE UE through analysis and measurement. Then, we performed to measure audio noise level according to the variation of transmitting power level and separation distance between the LTE UE and an audio device. As a result, it is required that minimum separation distance should be 25 cm and above in order to protect audio device from the interference noise of the LTE UE with the maximum transmit power level of 22 dBm.

Study on the random noise characteristic of the tracking radar in Naro space center (나로우주센터 추적레이더의 잡음 특성 분석)

  • Choi, Jee-Hwan;Shin, Han-Seop;Kim, Dae-Oh;Kim, Tae-Hyung
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.151-157
    • /
    • 2010
  • The tracking radars in NARO space center are precious, long-range tracking systems for tracking the launch vehicle (KSLV-1) and transmitting TSPI (Time, Space and Position Information) data to MCC (Mission Control Center). Because TSPI data from tracking radars to MCC are important information for the launch mission and flight safety control, TSPI data are required to be more accurate. In this paper, we analyzed theoretically the required specification of the random noise error in tracking radar and verified the real random noise error. In this analysis, we evaluated the TSPI data of several flight tests performed in NARO space center.

A Study on the Induced Voltages on Subscriber Telecommunication Lines from High-Speed Electrified Railway Line (고속전철에 의한 통신선로 전력유도 현상에 관한 고찰)

  • Oh, Ho-Seok;Kang, Seong-Yong;Yun, Ju-Yeong;Kim, Hak-Chul;Choi, Kyung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.10
    • /
    • pp.71-79
    • /
    • 2008
  • This paper analyzed the voltage induction phenomena on the telecommunication lines by electromagnetic coupling from high-speed A.C. electrified railway. The induced common mode voltages and the induced differential mode voltage on the telecommunication line was measured by notified standard method in the regulation of Korea. The test lines consist of 2 separated lines of 20 m and 300 m in influence distance each for comparison, with 2km inducing length. The analysis is made on the induced voltages from the different influence distances and the different earthing points, and also on the waveform and spectrum distributions. It is proved that the induction is arisen so good and the measured values are fair enough against noise such as the earth voltage differencing, and the current measuring scheme is also rightful.

Single-photon Detection at 1.5 ㎛ Telecommunication Wavelengths Using a Frequency up-conversion Detector (주파수 상향변환 검출기를 이용한 1.5 ㎛ 통신파장대역의 단일광자 측정)

  • Kim, Heon-Oh;Youn, Chun-Ju;Cho, Seok-Beom;Kim, Yong-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.5
    • /
    • pp.223-229
    • /
    • 2011
  • We present a low jitter frequency up-conversion detector based on quasi-phase matched sum frequency generation in a periodically poled $LiNbO_3$ waveguide for efficient single-photon detection at 1.5 ${\mu}m$ telecommunication wavelengths. The maximum detection efficiency and the noise count rate using the pump power of 300 mW and the pump wavelength of 974 nm are about 7% and 480 kHz, respectively. We also characterize the timing jitter of the frequency up-conversion detector by analyzing the time distribution of the detection outputs for photons generated through a picosecond pump pulsed spontaneous parametric downconversion. The minimum timing jitter was measured to be about 39.1 ps. Coincidence measurement with a narrow time window for pulsed up-conversion photons can eliminate the unwanted noise counts and maximize signal to noise ratio.