• Title/Summary/Keyword: 전자측정기

Search Result 250, Processing Time 0.027 seconds

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).

Screening Methods for Plant-Coating Materials and Transpiration Inhibitory Effect of Soybean Oil to Crops (식물 코팅 소재 선발법과 작물들에 대한 콩 오일의 증산 억제 효과)

  • Jung, In Hong;Park, No Bong;Kim, Sang-Yeol;Na, Young-Eun;Kim, Soon-Il
    • Korean Journal of Plant Resources
    • /
    • v.27 no.4
    • /
    • pp.380-391
    • /
    • 2014
  • Plants as well as crops are damaged by a combination of the hot and dry winds that has been a major factor in the reduction of crop production. A means to protect them from damaging conditions is to consider a coating material. In this study, we established laboratory screening methods to find a coating material to protect a crop from rapid transpiration caused by various factors. In a test measuring the weight loss of kidney bean seedlings for 6 days, Avion treatments decreased its weight loss (P=0.05). Owing to long-time spend in completing this assay, we performed a more simple method using a cobalt chloride paper strip, which changes from blue to red colors under water condition. Beewax, guagum, paraffin liquid, soybean oil, and PE-635 gave a waterproofing effect above 37 and 43% at 0.5 and 1 h after treatment, respectively. However, these tested materials did not show significant waterproofing results at 2 h. Although the methods produced reasonable results, a screening method to obtain more objective data is needed. An alternative is to use an instrument that can detect the transpiration of crop leaves. In a preliminary test using barley leaves, a portable photosynthesis system showed transpiration inhibition of 2% soybean oil and 10 times-diluted Avion under field conditions. In another test using the leaves of maize seedlings and apricot tree, 2% liquid paraffin and plant oils such as apricot oil, linseed oil, olive oil, and soybean oil showed significant transpiration inhibition (P=0.05). Especially, paraffin liquid and soybean oil selected from above tests gave good transpiration inhibitory effects against rice at 2%. In addition, the mixture of 2% soybean oil and a spreader showed more elevated inhibition results comparing with soybean oil or the spreader alone indicating that the spreader may be attributed to more uniform diffusion of the hydrophobic material onto the leaf surface of maize seedlings. The hydrophobic material coated physically the stomata and cuticle layers on leaf surfaces of rice. These hydrophobic materials screened in this study are expected to be used as plant coating materials.

EFFECT OF VARIOUS MECHANICAL TREATMENTS ON TITANIUM PLASMA SPRAYED IMPLANT SURFACES (Titanium plasma sprayed implant에 관한 여러가지 기계적 표면처리방법이 implant표면조도에 미치는 영향)

  • Yu, Hyeon-Seok;Park, Jae-Wan;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.493-506
    • /
    • 1993
  • For maintenance of an ailing or failed implant it is essential to treat the implant fixture surface so as to remove bacterial endotoxin and make a surface tolerated by surrounding soft and hard tissue. Thus in this study the method that makes the smoothest surface treated with a high speed diamond bur, a low speed diamond bur, a stone, a rubber point or Jetpolisher was studied. With the profilomenter a mean value of $R_{max}$ was measured. The hight speed diamond, the rubber point and the Jetpolisher showed a mean $R_{max}\;7.77{\mu}m$. The low speed diamond bur, the rubber, point and the Jetolisher made a mean value of $R_{max}\;8.44{\mu}m$. The stone, the rubber point and the Jetolisher showed the smoothest surfaces with a mean value of $R_{max}\;6.24{\mu}m$. TPS (titanium plasma sprayed) areas showed a mean vlaue of $R_{max}\;24.42{\mu}m$, and the smooth surfaced titanium disc manufactured by the company (IMZ, Germany) shows a mean value of $R_{max}\;3.00{\mu}m$. Under the SEM examination the disc treated with a high speed diamond bur, a rubber point and a Jetpolisher showed partially remaining TPS particles, but the height of these particles were reduced remarkably compared with those of the original TPS. The disc treated with a low speed diamond bur, a rubber point and a Jetpolisher showed a rough topography with remaining TPS on the entire surface. A stone, a rubber point and a Jetpolisher removed almost TPS and the bulk titanium metal was exposed and some scratches were made by the stone. All treated discs were revealed as rougher than the smooth surface disc manufactured by the company. An untreated TPS disc shows a very irregular surface and a $40{\mu}m$ height of the plasma sprayed areas.

  • PDF

Property of Nickel Silicide with 60 nm and 20 nm Hydrogenated Amorphous Silicon Prepared by Low Temperature Process (60 nm 와 20 nm 두께의 수소화된 비정질 실리콘에 따른 저온 니켈실리사이드의 물성 변화)

  • Kim, Joung-Ryul;Park, Jong-Sung;Choi, Young-Youn;Song, Oh-Sung
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.528-537
    • /
    • 2008
  • 60 nm and 20 nm thick hydrogenated amorphous silicon(a-Si:H) layers were deposited on 200 nm $SiO_2$/single-Si substrates by inductively coupled plasma chemical vapor deposition(ICP-CVD). Subsequently, 30 nm-Ni layers were deposited by an e-beam evaporator. Finally, 30 nm-Ni/(60 nm and 20 nm) a-Si:H/200 nm-$SiO_2$/single-Si structures were prepared. The prepared samples were annealed by rapid thermal annealing(RTA) from $200^{\circ}C$ to $500^{\circ}C$ in $50^{\circ}C$ increments for 40 sec. A four-point tester, high resolution X-ray diffraction(HRXRD), field emission scanning electron microscopy(FE-SEM), transmission electron microscopy(TEM), and scanning probe microscopy(SPM) were used to examine the sheet resistance, phase transformation, in-plane microstructure, cross-sectional microstructure, and surface roughness, respectively. The nickel silicide from the 60 nm a-Si:H substrate showed low sheet resistance from $400^{\circ}C$ which is compatible for low temperature processing. The nickel silicide from 20 nm a-Si:H substrate showed low resistance from $300^{\circ}C$. Through HRXRD analysis, the phase transformation occurred with silicidation temperature without a-Si:H layer thickness dependence. With the result of FE-SEM and TEM, the nickel silicides from 60 nm a-Si:H substrate showed the microstructure of 60 nm-thick silicide layers with the residual silicon regime, while the ones from 20 nm a-Si:H formed 20 nm-thick uniform silicide layers. In case of SPM, the RMS value of nickel silicide layers increased as the silicidation temperature increased. Especially, the nickel silicide from 20 nm a-Si:H substrate showed the lowest RMS value of 0.75 at $300^{\circ}C$.

EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT (레진전색제의 마모저항성에 대한 평가)

  • Kim, Soo-Mee;Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.180-190
    • /
    • 2007
  • The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface. Two hundred rectangular specimens, sized $8\times3\times2mm$, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads B-IM group was not subjected to toothbrush abrasion test. Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan) . A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows; 1. Ra off group was $0.898{\pm}0.145{\mu}m$ and B-IM group was $0.289{\pm}0.142{\mu}m$. Ra became higher from B-1 group $(0.299{\pm}0.48{\mu}m$ to B-18 group $(0.642{\pm}0.313{\mu}m$. 2. Final cluster center of Ra was $0.361{\mu}m$ in cluster 1 $(B-IM\simB-7)$, $0.511{\mu}m$ in cluster 2 $(B-8\simB-14)$ and $0.624{\mu}m$ in cluster 3 ($(B-15\simB-18)$. There were significant difference among Ra of three clusters. 3 Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group. 4. On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches , and wide and irregular vertical scratches on composite resin surface respectively. Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.

Comparison Analysis of The results of IRMA Test among Different Equipment According to Algorithm change. (IRMA 검사법 중 알고리즘 변경에 따른 장비 간 결과값 비교분석)

  • Kim, Jung In;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.43-50
    • /
    • 2019
  • Purpose The principle of nuclear medicine test is divided into two main categories: competition(radioimmunoassay, RIA) and noncompetitive reaction(Immunoradiometric assay, IRMA). It is known that the curve fitting method, which is commonly used in inspection field, uses Spline interpolation in RIA method and Linear interpolation method in IRMA method. Among them, the insulin test using the IRMA test showed a significant difference, especially at low concentrations, despite the same algorithm of linear interpolation between fully automated radio immunoassay analyzers. In this study, we aim to obtain results from applying two different of algorithm using fully automated radio immunoassay analyzers including Gamma pro, Gamma 10, Cobra, and SR300. Materials and Methods A total of 30 test samples were selected for the test of TSH, ferritin, C-peptide, and insulin serum levels. Test was performed by IRMA method. We compared the difference in the results of applying the linear interpolation method and the spline interpolation method to Gamma Pro, Gamma 10, Cobra, and SR300 equipment. Results Two-way ANOVA was used for statistical analysis. The significance level was applied as P <0.05. The results of TSH, ferritin, C-peptide, and insulin tests were compared between the fully automated radio immunoassay analyzers. There was a significant difference between ferritin, C-peptide, and insulin serum levels(P<0.001). TSH didn't show any significant different between the devices(P=0.29). In the difference between linear and spline interpolation, there was no significant difference between insulin test(P=0.08), TSH test(P=0.81), and Ferritin test(P=0.06). However, C-peptide test showed a significant difference(P=0.03). Especially, the insulin test showed significant difference in lower ranges. As a result of comparing and analyzing the difference between the two interpolation methods, the devices in the low concentration group showed significant difference(P<0.001). Conclusion In case of new equipment in the laboratory it is necessary to recognize that there is a difference in the curve fitting method for each automated radio immunoassay analyzers in the low concentration area when the principle of inspection is IRMA method.

Effect of fabrication method and surface polishing on the surface roughness and microbial adhesion of provisional restoration (임시 수복물의 제작 방식과 표면 연마가 표면 거칠기와 세균 부착에 미치는 영향)

  • Yeon-Ho Jung;Hyun-Jun Kong;Yu-Lee Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.149-158
    • /
    • 2024
  • Purpose: This study aims to investigate the effects of provisional restoration fabrication methods and surface polishing on surface roughness and microbial adhesion through in vitro experiments. Materials and Methods: 120 cylindrical provisional restoration resin blocks (10 × 10 × 2.5 mm) were manufactured according to four fabrication methods, and 30 specimens were assigned to each group. Afterwards, they were divided into non-polishing group, #400 grit SiC polishing group, and #800 grit SiC polishing group and polished to a 10 × 10 × 2 mm specimen size (n = 10). The surface roughness Ra and Ry of the specimen was measured using a Surface Roughness Tester. Three specimens were extracted from each group and were coated with artificial saliva, and then Streptococcus mutans were cultured on the specimens at 37℃ for 4 hours. The cultured specimens were fixed to fixatives and photographed using a scanning electron microscope. For statistical analysis, the two way of ANOVA was performed for surface roughness Ra and Ry, respectively, and the surface roughness was tested post-mortem with a Scheffe test. Results: The fabrication method and the degree of surface polishing of the provisional restorations had a significant effect on both surface roughness Ra and Ry, and had an interaction effect. There was no significant difference in Ra and Ry values in all polishing groups in DLP and LCD groups. Conclusion: The fabrication method and surface polishing of the provisional restoration had a significant effect on surface roughness and showed different adhesion patterns for S. mutans adhesion.

Dry etching of polycarbonate using O2/SF6, O2/N2 and O2/CH4 plasmas (O2/SF6, O2/N2와 O2/CH4 플라즈마를 이용한 폴리카보네이트 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, S.H.;Cho, G.S.;Song, H.J.;Jeon, M.H.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • We studied plasma etching of polycarbonate in $O_2/SF_6$, $O_2/N_2$ and $O_2/CH_4$. A capacitively coupled plasma system was employed for the research. For patterning, we used a photolithography method with UV exposure after coating a photoresist on the polycarbonate. Main variables in the experiment were the mixing ratio of $O_2$ and other gases, and RF chuck power. Especially, we used only a mechanical pump for in order to operate the system. The chamber pressure was fixed at 100 mTorr. All of surface profilometry, atomic force microscopy and scanning electron microscopy were used for characterization of the etched polycarbonate samples. According to the results, $O_2/SF_6$ plasmas gave the higher etch rate of the polycarbonate than pure $O_2$ and $SF_6$ plasmas. For example, with maintaining 100W RF chuck power and 100 mTorr chamber pressure, 20 sccm $O_2$ plasma provided about $0.4{\mu}m$/min of polycarbonate etch rate and 20 sccm $SF_6$ produced only $0.2{\mu}m$/min. However, the mixed plasma of 60 % $O_2$ and 40 % $SF_6$ gas flow rate generated about $0.56{\mu}m$ with even low -DC bias induced compared to that of $O_2$. More addition of $SF_6$ to the mixture reduced etch of polycarbonate. The surface roughness of etched polycarbonate was roughed about 3 times worse measured by atomic force microscopy. However examination with scanning electron microscopy indicated that the surface was comparable to that of photoresist. Increase of RF chuck power raised -DC bias on the chuck and etch rate of polycarbonate almost linearly. The etch selectivity of polycarbonate to photoresist was about 1:1. The meaning of these results was that the simple capacitively coupled plasma system can be used to make a microstructure on polymer with $O_2/SF_6$ plasmas. This result can be applied to plasma processing of other polymers.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

SURFACE ROUGHNESS OF COMPOSITE RESIN ACCORDING TO FINISHING METHODS (복합레진 표면의 연마방법에 따른 표면조도)

  • Min, Jeong-Bum;Cho, Kong-Chul;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.138-150
    • /
    • 2007
  • The purpose of this study was to evaluate the difference of surface roughness of composite resin according to composite resin type, polishing methods, and use of resin sealant. Two hundred rectangular specimens, sized $8{\times}3{\times}2mm$, were made of Micro-new (Bisco, Inc., Schaumburg, IL, U.S.A) and Filtek Supreme (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and divided into two groups; Micronew-M group, Filtek Supreme-S group. Specimens for each composite group were subdivided into five groups by finishing and polishing instruments used; M1 & S1(polyester strip), M2 & S2 (Sof-Lex disc), M3 & S3 (Enhance disc and polishing paste), M4 & S4(Astropol) and M5 & S5 (finishing bur), Polished groups were added letter B after the application of resin surface sealant (Biscover), eg, M1B and S1B. After specimens were stored with distilled water for 24hr, average surface roughness (Ra) was taken using a surface roughness tester. Representative specimens of each group were examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using paired t-test, ANOVA and Duncan's tests at the 0.05 probability level. The results of this study were as follows ; 1. The lowest Ra was achieved in all groups using polyester strip and the highest Ra was achieved in M5, S5 and M5B groups using finishing bur. On FE-SEM, M1 and S1 groups provided the smoothest surfaces, M5 and S5 groups were presented the roughest surfaces and voids by debonding of filler on the polished specimens. 2. There was no significant difference in Ra between Micronew and Filtek Supreme before the application of resin sealant, but Micronew was smoother than Filek Supreme after the application of resin sealant. 3. There was significant corelation between Ra of type of composite resin and polishing methods before the application of resin sealant (p=0.000), but no significant interaction between them after the application of resin sealant. On FE-SEM, most of composite resin surfaces were smooth after the application of resin sealant on the polished specimens. 4. Compared with before and after the application of resin sealant in group treated in the same composite and polishing methods, Ra of M4B and M5B was statistically lower than that of M4 and M5, and S5B was lower than that of S5, respectively (p<0.05). In conclusion, surface roughness by polishing instruments was different according to type of composite resin. Overall, polyester strip produced the smoothest surface, but finishing bur produced the roughest surface. Application of resin sealant provided the smooth surfaces in specimens polished with Enhance, Astropol and finishing bur, but not provided them in specimens polished with Sof-Lex disc.