• Title/Summary/Keyword: 이레전자

Search Result 22, Processing Time 0.026 seconds

업계소식

  • Korea Far Infrared Association
    • Journal of Korea Far Infrared Association
    • /
    • s.15
    • /
    • pp.16-25
    • /
    • 2002
  • PDF

'IT강국도약을 위한 2002년 정보통신 정책방향'

  • Korean Associaton of Information & Telecommunication
    • 정보화사회
    • /
    • s.155
    • /
    • pp.26-29
    • /
    • 2002
  • 본 협회가 주최하고 전자신문이 후원하는 "제5회 정보통신포럼"이 지난 27일 하얏트호텔 로터스 룸에서 열렸다. 이날 포럼에는 김태현 정보통신부 차관이 초청돼 'IT강국도약을 위한 2002년 정보통신 정책방향'을 밝혔다. 조정남 SK텔레콤 부회장, 신재철 한국IBM 사장, 남용 LG텔레콤 사장, 정문식 이레전자산업 사장, 정용섭 정보보호산업협회장 등이 참석한 이 날 포럼에서 발표된 자료를 요약했다.

  • PDF

Research Trends on Distributed Storage Technology for Blockchain Transaction Data (블록체인 트랜잭션 데이터 분산 저장 기술 동향)

  • Choi, B.J.;Kim, C.S.;Lee, M.C.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.3
    • /
    • pp.85-96
    • /
    • 2022
  • Recently, the blockchain technology, which can decentralize business ecosystems using secure transactions without trusted intermediaries, has been spotlighted. Full nodes play an important role in maintaining decentralization in that they independently verify transactions using their full historical transaction data. However, the storage requirement of a full node for storing historical data is continuously increasing, and thus, has become harder for users to run a full node due to the heavy price for storage costs. In this paper, we investigate research trends on reducing the costs of storing blockchain transaction data so that nodes with low storage requirements can be used in the blockchain network.

A Study on composition of current stable negative resistance circuits. (전류안정부저항회로의 구성에 관한 연구)

  • 박의열
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.1
    • /
    • pp.9-17
    • /
    • 1973
  • This paper dealt with composition of current stable negatil'e resistance circuit based on Beam resistance of the tube SAMUEL SEBLY suggested. Beam resistance which is decreased by input current increment on definite region of current, accompanied generation of equivalent e. m. f on model circuit. With equivalent e. m. f there appeared increased current on circuit but decrease of terminal voltage. Bloc constructed by above concept induced transistorized circuit which have NPN and a PNP Transistor. Circuit operation predicted and calculated values of negative resistance are coincident with experimental results. A Circuit proposed on this paper sllowed good linearity on Ve-Ji characteristics.

  • PDF

High Quality Non-Transfer Single-Layer Graphene Process Grown Directly on Ti(10 nm)-Buffered Layer for Photo Lithography Process (포토 리소그래피 공정을 위한 Ti(10 nm)-Buffered층 위에 직접 성장된 고품질 무전사 단층 그래핀 공정)

  • Oh, Keo-Ryong;Han, Yire;Eom, Ji-Ho;Yoon, Soon-Gil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.21-26
    • /
    • 2021
  • Single-layer graphene is grown directly on Ti-buffered SiO2 at 100℃. As a result of the AFM measurement of the Ti buffer layer, the roughness of approximately 0.2 nm has been improved. Moreover, the Raman measurement of graphene grown on it shows that the D/G intensity ratio is extremely small, approximately 0.01, and there are no defects. In addition, the 2D/G intensity ratio had a value of approximately 2.1 for single-layer graphene. The sheet resistance is also 89 Ω/□, demonstrating excellent characteristics. The problem was solved by using graphene and a lift-off patterning method. Low-temperature direct-grown graphene does not deteriorate after the patterning process and can be used for device and micro-patterning research.

The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube (강내형 X선 튜브 온도 및 선량 분포 특성)

  • Cho, Sungho;Lee, Rena
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.262-266
    • /
    • 2013
  • A new concept of periapical radiography, intra oral x-ray tube and detector system is introduced. It is new system that a miniature x-ray tube is inserted into mouse and it acquired digital image using external detector. In this study, we have investigated temperature and dose distribution of insertional x-ray tube for periapical radiography. To analyze temperature characteristic of x-ray tube, we attached the thermocouple to surface of x-ray tube and we measured the temperature according to distance. Also, we measured the dose distribution of a miniature x-ray tube according to distance. As a result, temperature was constant to $27^{\circ}C$ over 2mm without cooling system, dose distribution of x-ray tube was 3.14 and 1.84mGy in 3 and 5cm, respectively. Therefore, the proposed x-ray system works in lower dose than conventional dental x-ray system. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

Reed-Solomon Encoded Block Storage in Key-value Store-based Blockchain Systems (키값 저장소 기반 블록체인 시스템에서 리드 솔로몬 부호화된 블록 저장)

  • Seong-Hyeon Lee;Jinchun Choi;Myungcheol Lee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.3
    • /
    • pp.102-110
    • /
    • 2024
  • Blockchain records all transactions issued by users, which are then replicated, stored, and shared by participants of the blockchain network. Therefore, the capacity of the ledger stored by participants continues to increase as the blockchain network operates. In order to address this issue, research is being conducted on methods that enhance storage efficiency while ensuring that valid values are stored in the ledger even in the presence of device failures or malicious participants. One direction of research is applying techniques such as Reed-Solomon encoding to the storage of blockchain ledgers. In this paper, we apply Reed-Solomon encoding to the key-value store used for ledger storage in an open-source blockchain, and measure the storage efficiency and increasing computational overhead. Experimental results confirm that storage efficiency increased by 86% while the increase in CPU operations required for encoding was only about 2.7%.

Introduction of Dental X-ray Imaging with New Concept - intra Oral x-ray Tube (신개념 치과용 X-선 영상장치 소개 - 강내형 X-선 튜브)

  • Cho, Sung-Ho;Kim, Dong-Young;Baek, Kwang-Woo;Lee, Re-Na
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.94-101
    • /
    • 2011
  • Various kinds of medical imaging devices have been studied to develop periapical radiography. However, there are some problems such as high x-ray exposure rate and pains for patients because of the problems caused by intra-oral sensor based radiography system. In this study, a new concept of periapical radiography, intra oral X-ray tube and detector system, is introduced to solve these problems. This system is made up of miniature X-ray tube based on subminiature thermal electron or cold electron, CMOS based detector, and a body including automatic position and system control devices. In order to confirm the possibility of proposed new concept to periapical radiography, miniature x-ray tube from XOFT corporation is used to develop new x-ray system, and the performance evaluation of this system is performed according to collimator. Also, dental images are compared after acquiring both images from existing system versus new concept of system. As a result, new concept of system showed excellent image. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

Evaluation of Electron Boost Fields based on Surgical Clips and Operative Scars in Definitive Breast Irradiation (유방보존술 후 방사선치료에서 수술 흉터와 삽입된 클립을 이용한 전자설 추가 방사선 조사야 평가)

  • Lee, Re-Na;Chung, Eun-Ah;Lee, Ji-Hye;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.236-242
    • /
    • 2005
  • Purpose: To evaluate the role of surgical clips and scars in determining electron boost field for early stage breast cancer undergoing conserving surgery and postoperative radiotherapy and to provide an optimal method in drawing the boost field. Materials and Methods: Twenty patients who had $4{\sim}7$ surgical clips in the excision cavity were selected for this study. The depth informations were obtained to determine electron energy by measuring the distance from the skin to chest wall (SCD) and to the clip implanted in the most posterior area of tumor bed. Three different electron fields were outlined on a simulation film. The radiological tumor bed was determined by connecting all the clips implanted during surgery Clinical field (CF) was drawn by adding 3 cm margin around surgical scar. Surgical field (SF) was drawn by adding 2 cm margin around surgical clips and an Ideal field (IF) was outlined by adding 2 cm margin around both scar and clips. These fields were digitized into our planning system to measure the area of each separate field. The areas of the three different electron boost fields were compared. Finally, surgical clips were contoured on axial CT images and dose volume histogram was plotted to investigate 3-dimensional coverage of the clips. Results : The average depth difference between SCD and the maximal clip location was $0.7{\pm}0.55cm$. Greater difference of 5 mm or more was seen in 12 patients. The average shift between the borders of scar and clips were 1.7 1.2, 1.2, and 0.9 cm in superior, inferior, medial, and lateral directions, respectively. The area of the CF was larger than SF and IF in 6y20 patients. In 15/20 patients, the area difference between SF and if was less than 5%. One to three clips were seen outside the CF in 15/20 patients. In addition, dosimetrically inadequate coverage of clips (less than 80% of prescribed dose) were observed in 17/20 patients when CF was used as the boost field. Conclusion: The electron field determined from clinical scar underestimates the tumor bed in superior-inferior direction significantly and thereby underdosing the tissue at risk. The electron field obtained from surgical clips alone dose not cover the entire scar properly As a consequence, our technique, which combines the surgical clips and clinical scars in determining electron boost field, was proved to be effective in minimizing the geographical miss as well as normal tissue complications.

Analysis of Output Constancy Checks Using Process Control Techniques in Linear Accelerators (선형가속기의 출력 특성에 대한 공정능력과 공정가능성을 이용한 통계적 분석)

  • Oh, Se An;Yea, Ji Woon;Kim, Sang Won;Lee, Rena;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.185-192
    • /
    • 2014
  • The purpose of this study is to evaluate the results for the quality assurance through a statistical analysis on the output characteristics of linear accelerators belonging to Yeungnam University Medical Center by using the Shewhart-type chart, Exponentially weighted moving average chart (EWMA) chart, and process capability indices $C_p$ and $C_{pk}$. To achieve this, we used the output values measured using respective treatment devices (21EX, 21EX-S, and Novalis Tx) by medical physicists every month from September, 2012 to April, 2014. The output characteristics of treatment devices followed the IAEA TRS-398 guidelines, and the measurements included photon beams of 6 MV, 10 MV, and 15 MV and electron beams of 4 MeV, 6 MeV, 9 MeV, 12 MeV, 16MeV, and 20 MeV. The statistical analysis was done for the output characteristics measured, and was corrected every month. The width of control limit of weighting factors and measurement values were calculated as ${\lambda}=0.10$ and L=2.703, respectively; and the process capability indices $C_p$ and $C_{pk}$ were greater than or equal to 1 for all energies of the linear accelerators (21EX, 21EX-S, and Novalis Tx). Measured values of output doses with drastic and minor changes were found through the Shewhart-type chart and EWMA chart, respectively. The process capability indices $C_p$ and $C_{pk}$ of the treatment devices in our institution were, respectively, 2.384 and 2.136 for 21EX, 1.917 and 1.682 for 21EX-S, and 2.895 and 2.473 for Novalis Tx, proving that Novalis Tx has the most stable and accurate output characteristics.