• Title/Summary/Keyword: 유동성 레진

Search Result 42, Processing Time 0.017 seconds

A STUDY ON PHYSICAL PROPERTIES OF FLOWABLE COMPOSITE RESINS (유동성 복합레진의 물리적 성질에 대한 연구)

  • Kim, Ji-Young;Jeong, Byung-Cho;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.423-429
    • /
    • 2002
  • Recently, the clinical uses of flowable composite resins have increased because of fast, convenient and excellent accessibility, but little has been reported about physical properties of flowable resins. The purpose of this study was to measure and compare the physical properties(compressive strength, relative flowability, relative radiopacity) of 4 contemporary flowable composite resins(Filtek flow, Tetric Flow, Revolution Palfique Estelite LV high flow). The results were as follows; 1. There were no significant differences between 4 flowable composite resins in compressive strength, but all were lower than that of traditional hybrid composite resin(p<0.001). 2. The relative flowability were increased in order of Palfique Estelite LV high flow, Revolution, Filtek flow, Tetric Flow and sealant(p<0.001), but there were no significant differences between Filtek flow and Tetric Flow. 3. There were significant differences between flowable composite resins in relative radiopacity and they showed similar or higher radiopacity than dentin(p<0.001), especially Tetric Flow and Filtek Flow showed higher radiopacity than enamel(p<0.001). This results suggested that the stress of application area have to be considered since flowable composite resins have lower compressive strength than hybrid composite, and the differences of flowability between these flowable composite resins can be considered when they are selected. All tested flowable composite resins showed optimal radiopacity to ISO's recommend.

  • PDF

EVALUATION OF THREE FLOWABLE COMPOSITES AS PIT AND FISSURE SEALANTS WITHOUT USING BONDING AGENTS (접착제 미 사용시 치면열구전색제로서의 유동성 복합레진 평가)

  • Kwon, Ho-Beom;Kim, Myoung-Jin;Shin, Cheol-Hwan;Kim, Ji-Yeon;Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.244-252
    • /
    • 2006
  • The aims of this study were to determine if flowable composites can be used as pit and fissure sealants without bonding agents. Three flowable composites(Filtek Flow, Tetric Flow, Charmfil Flow) and a filled sealant (Ultraseal XT plus) were used. The pattern of resin tag formation in the four sealant materials were compared using SEM. For the microleakage assessment, 54 extracted human premolar teeth were randomly divided into 3 groups containing 18 premolars each. In each group, a conventional filled sealant and one of the three flowable composites were applied to occlusal fissures. The teeth were thermocycled(1200 cycles between $5^{\circ}{\pm}2^{\circ}C\;and\;55^{\circ}{\pm}2^{\circ}C$ with a dwell time of 30 seconds) and immersed in a 1% methylene blue solution for 48 hours. Each tooth was sectioned and examined to determine the extent of dye penetration. Three flowable composites and a filed sealant showed a similar resin tag formation pattern. The three flowable composites showed significantly more microleakage in each group than the filled sealant. The level of microleakage was similar in the three flowable composites. Flowable composites are not recommended as pit and fissure sealants because more microleakage can occur even when occlural fissures are mechanically widened.

  • PDF

Influence of flowable composite lining on microleakage at the gingival dentin margin (유동성 레진이 치은 상아질 변연 누출에 미치는 영향)

  • Lee, Jung-Min;Kim, Young-Kyung;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.394-402
    • /
    • 2002
  • 2급 복합레진 수복 와동의 치은 변연이 상아질 상에 있을 때 유동성 레진 이장의 유무와 두께가 미세누출에 미치는 영향을 알아보기 위해 본 실험을 시행하였다. 60개의 발거된 대구치의 근, 원심면에 각각 협설측 3mm, 치은벽 깊이 1mm의 2급 와동을 형성하고 치은 변연은 법랑-백아 경계에서 약 1mm 하방에 위치 시켰다. 모든 와동을 32% 인산으로 15초 처리 및 30초 수세 후 Prime & Bond$^{\circledR}$ NT 상아질 접착제를 적용하였고, Tetric Ceram(TC), Tetric Flow(TF)를 이용하여 다음의 6가지 군으로 나누어 수복하였다. (1) TC로 수평 적층 충전, (2) TC로 수직 적층 충전, (3) 0.5-1mm두께로 TF 이장 후 TC로 수평적층 충전, (4) 0.5-1mm 두께로 TF 이장 후 TC로 수직 적층 충전, (5) 2-3mm 두께로 TF 이장 후 TC로 수평적층 충전, (6) 2-3mm두께로 TF이장 후 TC로 수직 적층 충전. 충전된 시편을 37$^{\circ}C$ 100% humidity에서 24시간 보관하고 5$^{\circ}C$와 55$^{\circ}C$에서 500회의 열순환을 실시하여 치은 변연의 0.5mm 외부에 nail varnish를 도포 하여 2% methylene blue 용액에 12시간 침잠시켰다. 시편을 아크릴릭 레진에 매몰하여 수복물의 중앙에서 종절단 한 후 입체현미경하에서 색소의 침투도를 관찰하여 다음과 같은 결과를 얻었다. 유동성 레진의 이장을 시행한 군과 하지 않은 군간에 미세누출은 유의차를 보이지 않았다(p>0.05) 유동성 레진의 두께에 따른 미세누출의 차이는 나타나지 않았다(p>0.05) 경사면 충전법을 시행한 군에서는 유동성 레진을 이장한 군들이 이장하지 않은 군보다 유의하게 많은 누출을 보였다(p<0.05). 수평적층 충전법을 시행한 군에서는 유동성 레진 이장이 미세누출에 유의한 차이를 보이지 않았다(p>0.05).

A STUDY ON THE CLINICAL USAGE OF THE FLOWABLE COMPOSITE RESIN (유동성 복합레진의 임상적 용도에 관한 검토 연구)

  • Park, So-Young;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.255-261
    • /
    • 2002
  • The purpose of this study was to compare the microleakage pattern of flowable composite resin to sealant, composite resin used in preventive resin restoration and glass ionomer cement used as liner. 120 extracted sound human molars were divided into 6 groups : group 1 and 2:sealant ; group 3 and 4:preventive resin restoration ; group 5 and 6:sandwich technique restoration. For the experimental groups(group 2, 4 and 6), flowable composite resin(Tetric flow) was used. For the control group, Concise was used as sealant material(group 1), Z-100 with Concise were used as preventive resin restoration(group 3), and Vitrebond was used as cavity liner(group 5). All the restorations were thermocycled and the degree of dye penetration was evaluated with stereomicroscope. The microleakage of each group was measured and statistically analyzed. The results of the present study were as follows : 1. In group 1 and 2, there was no statistically significant difference in microleakage between Concise and Tetric flow(p>0.05). 2. In groups of preventive resin restorations, there was no statistically significant difference in microleakage between Z-100 with Concise and Tetric flow(p>0.05). 3. The microleakage of Vitrebond and Tetric flow used as liner showed no statistically significant difference(p>0.05).

  • PDF

Evaluation of Microleakage and Penetration Ability of Flowable Resin in Occlusal Fissure (유동성 레진의 교합면 열구내 침투도와 미세누출 평가)

  • Cheong, Hyeran;Im, Sungok;Lee, Sangho;Lee, Nanyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.89-98
    • /
    • 2017
  • The aim of this study was to compared the penetration scores and microleakage levels of flowable resin in comparison to resin-based pit and fissure sealant. A total 120 extracted premolars were used and classified with group I (resin-based pit and fissure sealant), group II (flowable resin), group III (bonding agent + flowable resin), IV (fissurotomy + bonding agent + flowable resin) depending on the materials and the application methods. The penetration scores of the group treated with flowable resin following fissurotomy were similar to those of the group treated with resin-based sealant, but higher compared to those of the other groups treated with flowable resin without fissurotomy or bonding agent. The group treated with flowable resin following fissurotomy also exhibited the lowest microleakage levels. The group treated with resin-based sealant and the one treated with a bonding agent prior to the application of flowable resin showed similar microleakage levels. In conclusion, flowable resin may be applied as a pit and fissure sealant, and its application along with fissurotomy could increase the penetration scores.

THE EFFECT OF MARGINAL MICROLEAKGE ACCORDING TO THICKNESS OF FLOWBLE RESIN (유동성 레진의 두께가 미세누출에 미치는 영향)

  • Song, Gi-Gang;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.363-371
    • /
    • 2005
  • This study investigated the effect of thickness of flowable resin lining on marginal leakage in class II composite restorations. 80 experimental teeth were prepared with class II preparations with enamel margin or dentin margin. Each group was devided into four groups according to flowable resin lining thickness ; Control group - no flowable resin lining, Group 1 - 0.5 mm flowable resin lining, Group 2 - 1 mm flowable resin lining, Group 3 - 2 mm flowable resin lining. The cavities were restored using Scotchbond Multi-Purpose adhesive system, Filtek Flow and Filtek Z 250 composite resin. Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles and immersed in $2\%$ methylene blue for 24 hours. The results of this study were as follows : 1. Ranking of mean microleakage scores at the enamel margins was Group 1 < Control = Group 2 < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 and Group 2 (p < 0.05). 2. Ranking of mean microleakage scores at the dentin margins was Group 1 < Group 2 < Control < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 (p < 0.05) 3. Compared with microleakage between the enamel and dentin margins, enamel margin group were significantly lower than dentin margin group.

Survival Rates of Class II Restoration in Primary Molar with Flowable Resin Composite (유동성 복합레진을 이용한 유구치 II급 수복의 생존율)

  • Seo, Hyejun;Park, Soyoung;Lee, Eungyung;Jeong, Taesung;Shin, Jonghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.12-20
    • /
    • 2021
  • The purpose of this retrospective study was to evaluate the survival rate by comparing Class II restoration using flowable resin composite with stainless steel crown in primary molars. Electronic medical records and radiographs of 1,504 primary molars with proximal caries of 590 patients from June 2015 to August 2019 were analyzed. With the collected data, survival analysis was performed using the Kaplan-Meier method. The 1-year survival rate of flowable resin composite in the primary molar was 98.5%, 3-year survival rate was 87.7%, and mean survival time was 39 months. There was no statistically significant difference between flowable resin composite and stainless steel crown (p = 0.896). Within the limits of this study, Class II restoration using flowable resin composite can be considered a promising option for the treatment of proximal caries in primary molars.

A COMPARATIVE STUDY ON THE MICROLEAKAGE OF PRVENTIVE RESIN RESTORATION USING FLOWABLE COMPOSITE RESIN (유동성 복합 레진을 적용한 예방적 레진 수복물의 미세 누출 양상에 관한 비교 연구)

  • Park, Heon-Jeong;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.419-430
    • /
    • 2000
  • The purpose of this study was to compare the microleakage pattern of preventive resin restoration using conventional composite resin and flowable composite resin that recently developed. 60 sound premolar teeth were allocated to three groups. Flowable composite resin was used for the experimental groups(Group I and II) and conventional resin for the control group(Group III). After composite filling and sealant application, all teeth were thermocycled and evaluated for microleakage under light microscope. Additionally, a variety of voids formed inside restorations were also evaluated. Data were analyzed statistically using Kruskal-Wallis test and/or Mann-Whitney U-test. The results of the present study were as follows. 1. Microleakage found in all samples was only limited to the interface of restoration margin and enamel. 2. The flowable composite resin groups (Group I, II) generally showed less microleakage than control groups (conventional preventive resin restoration) (p<0.05) 3. Various types of voids were observed in most specimens. Especially, there was a tendency for more and larger voids to be found in group I, II than group III (p<0.05).

  • PDF

COMPARISON OF MARGINAL MICROLEAKAGE BETWEEN LOW AND HIGH FLOWABLE RESINS IN CLASS V CAVITY (5급 와동에서 저유동성과 고유동성 레진의 변연 미세누출 비교)

  • Bae, Sang-Bae;Cho, Young-Gon;Lee, Myeong-Seon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.477-483
    • /
    • 2009
  • The purpose of this study was to compare the microleakage of low and high viscosity flowable resins in class V cavities applied with 1-step adhesives. Forty Class V cavities were prepared on the cervices of buccal and lingual surfaces of extracted molar teeth and divided into four groups (n=8). Cavities were restored with AQ Bond Plus /Metafil Flo $\alpha$, G-Bond/ UniFil LoFlo Plus (Low flow groups), AQ Bond Plus/Metafil Flo and G-Bond/UniFil Flow (High flow group), respectively. Specimens were immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed microleakages at the enamel and dentinal margins. In conclusion, the low viscosity flowable resins showed lower marginal microleakage than do the high vis cosity flowable resins in class V cavities.

AN IN VITRO STUDY OF MICROLEAKAGE OF COMPOSITE RESINS (복합레진의 미세누출에 관한 연구)

  • Lee, Sun-Young;Yang, Yeon-Mi;Baik, Byeong-Ju;Jeon, Cheol-Wan;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.593-599
    • /
    • 2003
  • The purposes of this study were to evaluate the microleakage of class V composite resin restorations utilizing the different curing lights, to assess the flowable resin, $Filtek^{TM}Flow$(3M Dental Products, USA) and composite resin, $Filtek^{TM}Z250$(3M Dental Products, USA) which need 20s curing time for halogen light could replace $Z100^{TM}$ Restorative(3M Dental Products, USA) for the microleakage, and to evaluate the effect of adhesive resin on marginal microleakage. Light curing units used in this study were conventional halogen light, XL3000(3M Dental Products, USA) and plasma arc light, Flipo(Lokki, France). Class V cavities were prepared and each cavity was filled with each composite resin. After being filled, the teeth were stored in distilled water, polished, thermocycled and soaked in 1% methylene blue solution. Following results were obtained from evaluation of the sectioned surface. 1. There was no statistically significant difference in microleakage of $Filtek^{TM}Flow$ and $Filk^{TM}Z250$ between two kinds of curing units(p>0.05). 2. Flowable resin, $Filtek^{TM}Flow$ showed more microleakage than Z100 and $Filtek^{TM}Z250$ regardless of curing units(p<0.05). 3. Adhesive resin reduced the microleakage of composite resin in both halogen light and plasma arc light(p<0.05).

  • PDF