• Title/Summary/Keyword: 부착 방법

Search Result 2,282, Processing Time 0.03 seconds

Effect of Fish Oil Ingestion on Serum Apoprotein and Platelet Function in Healthy Young Females (어유의 섭취가 젊은 여성의 혈청 Apoprotein 및 혈소판 기능에 미치는 영향)

  • 장현숙
    • Journal of Nutrition and Health
    • /
    • v.23 no.3
    • /
    • pp.157-169
    • /
    • 1990
  • This study was designed to investigate the effect of supplementation of fish oil on serum apoprotein and platelet function in healthy young females. Eighteen female college students were divided into 3 groups. Each group fed a typical Korean diet supplemented with 15g, 12g, and 9g of fish oil respectively for 1-week. Blood samples were obtained 4 times, before supplementation, immediately after, 1-week after and 3-week after stopping supplementation. After 6-week break, the doses of fish oil were interchanged among 3 groups and the experiment was repeated to reduce interindividual variation. The concentration of apoprotein A, apoprotein B in the serum samples and the platelet adhesion, the platelet aggregation and bleeding time were determined immediately after supplementation of fish oil, 1-week after and 3-week after stopping supplementation and then the value compared with those of before supplementation period. The results obtained are summarized as follows: Serum apoprotein A levels decreased significantly(p<0.05), immediately after supplementation of fish oil in the 15g group. The serum apoprotein B levels did not show significant change. The platelet adhesion decreased significantly(p<0.05) 1-week after supplementation of fish oil in the 15g group. The platelet aggregation decreased significantly(p<0.01) immedeately after supplementation of fish oil in the 15g group.

  • PDF

Study of Quality Control of Traditional Wine Using IT Sensing Technology (IT 센싱 기술을 이용한 전통주 발효의 품질관리 연구)

  • Song, Hyeji;Choi, Jihee;Park, Chan-Won;Shin, Dong-Beom;Kang, Sung-Soo;Oh, Sung Hoon;Hwang, Kwontack
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.6
    • /
    • pp.904-911
    • /
    • 2015
  • The objective of this study was to investigate the quality characteristics of traditional wine using an radio-frequency identification (RFID) system annexed to a fermenter. In this study, we proposed an RFID-based data transmission scheme for monitoring fermentation of traditional alcoholic beverages. The pH, total acidity, total sugar, soluble sugar, free sugar, alcohol content, and organic acids of were investigated and subjected to fermentation of traditional alcoholic beverages three times. The pH ranged from 7.98, 7.95, and 7.68 at day 0, decreased drastically to 3.31~2.96 at day 2, and then slowly increased to the end point, finally reaching 3.34 at day 20. Acidity tended to increase quickly with time, especially for all samples after day 2. The fermentation environment induced a sudden increase acidity in reactants and indicated a low pH. The total sugars during fermentation quickly decreased to the range of 20.3, 22.43, and 19.2% at day 2, and the slope of reduction steadily decreased to 5.1, 6.1, and 4.8% at day 10. On the other hand, the alcohol content showed the reverse trend as total sugars. The alcohol content also showed the same pattern as total acids, showing the highest alcohol content of 17.3% (v/v) on day 20. In this study on traditional wine fermentation using an RFID system, we showed that pH, soluble sugar, and alcohol content can be adopted as key indicators for quality control and standardization of traditional wine manufacturing.

Improvement of patient's quality of life by improving patient's set-up line in radiotherapy (방사선 치료 시 환자 Set-up Line 개선을 통한 암환자 삶의 질 만족도 향상)

  • Choi, Jin Hyuk;Ahn, Woo Sang;Lee, Woo Seok;Kim, Dae Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.185-189
    • /
    • 2018
  • Purpose : We evaluated the quality of life satisfaction of patients with radiation therapy while maintaining the set-up line. Materials and Methods : We retrospectively reviewed 60 patients who visited our clinic in January, 2018. The most common complaint was the inconvenience of not being able to wash during treatment (64 %), and a surgical tape was placed on the Set-up Line to help patients wash during the treatment period. A total of 50 patients who underwent surgical tape were evaluated on a 5-point scale (1 point was very unsatisfactory, 2 points were unsatisfactory, 3 points were average, 4 points were satisfied, 5 points were very satisfied). Forty patients out of 50 responded to the first treatment, and 10 patients underwent treatment. Results : In the first survey, 68 % of the patients and 32 % of the males were aged 34 %, 50~60 % and 38 %, respectively. Treatment areas were breast (57 %), chest (13 %), pelvis (10 %). The results of the second questionnaire after applying the surgical tape showed that 25 of the 40 patients and 15 of the male patients were treated. The treatment area was 22 breast and 18 pelvic areas. In the satisfaction of the 5-point scale, 5 to 15 points were satisfied with 1-3 points, and 4-5 points with 35 points (1 point 2 points, 2 points 2 points, 3 point 1 points, 4 point points 17 point points, % And 43 %, respectively. The results of the questionnaire survey of patients who were applied during the treatment showed that 9 out of 10 women and 1 male were treated. The treatment area was 8 breast and 2 pelvic areas. One point was satisfied with one point, and five points with nine points were satisfied with 90 %. Conclusions : The importance of improving the quality of life of patients with cancer is also important. After applying the surgical tape, 88 % of the patients who started the treatment and 90 % of the patients who applied during the treatment were satisfied. Particularly, patients who applied during treatment showed higher satisfaction. If this is not possible for all patients, selective application to patients with discomfort will be helpful in improving the quality of life of cancer patients.

  • PDF

Efficacy of Listeria Innocua Reduction on Enoki Mushrooms by Utilization of an Air Sterilization Device (공기 살균 장치 적용 팽이버섯 재배사의 Listeria Innocua 저감 효과)

  • Lee, Hyun-Dong;Yu, Byeong-Kee;Seo, Da-Som;Kim, Se-Ri;Lee, Chan-Jung;Kwak, Kang-Su
    • Journal of Mushroom
    • /
    • v.19 no.3
    • /
    • pp.210-215
    • /
    • 2021
  • For sterilization of microorganisms of the Listeria genus contaminating enoki mushroom, pilot mushroom grower equipped with air sterilization devices were developed. Sterilization experiments were performed using physical and chemical treatments. Internal temperature and humidity were controlled, maintaining 6.62℃±0.30 in the upper shelves, 6.46℃±0.24 in the middle shelves, and 6.48℃±0.25 in the lower shelves. Humidities were 79.97%±4.42, 79.43%±4.06, and 79.94±4.30%, respectively, with a temperature setting of 6.5℃, and a relative humidity of 75%. A suitable enoki mushroom cultivation stage for air sterilizer application was during the growth stage, with temperature in the 6.5~8.5℃ range, and humidity of 70~80%. At these same internal conditions, the ozone concentration in the mushroom cultivator was found to be 160 ppb during ion-cluster generator operation. After physical sterilization, the Listeria innocua survival rate was 0.1 to 0.9% using ion cluster sterilization, and 9.3 to 10.6% using UV air sterilization. The Listeria innocua survival rates on different materials were 9.3~10.6% on the metal specimen, and 9.9~16.2% on the plastic wrapper. The survival rate was particularly high on the rough side of the plastic wrapper. Ion cluster air sterilization is a labor-saving and effective method for suppressing the occurrence of Listeria bacteria on mushroom growers walls and shelves. For the plastic wrapper, chemical sterilization is more effective than physical sterilization.

Development of 3D Viewer for Tree Cavity using Pulse Ultrasound (펄스 초음파를 이용한 수목 공동부 3D 구현 프로그램 제작)

  • Son, Jungmin;Kang, Sunghoon;Moon, Jongwook;Yoon, Seokkyu;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.265-271
    • /
    • 2021
  • The pattern of the tree's internal swelling depends on many causes. Since it is difficult to detect these various causes of swelling with a general method, if the state of swelling for a long time cannot be confirmed, serious damage to the trees may occur due to enlargement of the swelling area. In the method of acquiring a tree tomography image, an impulse passing through the tree is generated by tapping the sensor with a rubber mallet, and the moving speed is recorded. In this paper, to measure cracks, cavities, and swelling due to physical damage, we developed a 3D viewer that can know the internal state of a tree using a tree cross-section image acquired from Arbotom to determine the degree of swelling inside the tree. Based on this, we tried to present data that can be referred to when surgical operation of trees is required. In order to acquire a tomographic image of a tree, 6 sensors were attached to the three Yangpala and Maple trees, and a 1 m-long tree was measured using the Arbotom program, and a 3D image was implemented through the 3D Viewer created using MATLAB. In addition to simply acquiring images, the cross-sectional length and volume of the tree were measured. In the actually produced 3D Viewer, the length of the part where the swelling of the maple tree occurred was 33.12 cm, and the swelling of the yangpala tree was measured as 21.41 cm. The volume of the maple tree was measured to be 78.832 ㎤. As a result of comparing the cross-sectional image of the Arbotom and the 3D image, the same result as the real aspect of the tree was obtained, so it can be judged that the reliability of the manufactured software is also secured, and data to be applied to the surgical tree operation through the created Viewer is provided. It is believed that the damage will be minimized.

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.

Prediction of Entrance Surface Dose in Chest Digital Radiography (흉부 디지털촬영에서 입사표면선량 예측)

  • Lee, Won-Jeong;Jeong, Sun-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.573-579
    • /
    • 2019
  • The purpose of this study is predicted easily the entrance surface dose (ESD) in chest digital radiography. We used two detector type such as flat-panel detector (FP) and IP (Imaging plate detector). ESD was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image. Dose-area product (DAP) or exposure index (EI) was checked by Digital Imaging and Communications in Medicine (DICOM) header on phantom images. Statistical analysis was performed by the linear regression using SPSS ver. 19.0. ESD was significant difference between FP and IP($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017). ESD was positively correlated with image quality in FP as well as IP. In FP, adjusted R square was 0.978 (97.8%) and linear regression model was $ESD=0.407+68.810{\times}DAP$. DAP was 4.781 by calculating the $DAP=0.021+0.014{\times}340{\mu}Gy$. In IP, adjusted R square was 0.645 (64.5%) and linear regression model was $ESD=-63.339+0.188{\times}EI$. EI was 1748.97 by calculating the $EI=565.431+3.481{\times}340{\mu}Gy$. In chest digital radiography, the ESD can be easily predicted by the DICOM header information.

Mechanism of steel pipe reinforcement grouting based on tunnel field measurement results (터널 현장 계측결과를 통한 강관보강 그라우팅의 거동 메커니즘)

  • Shin, Hyunkang;Jung, Hyuksang;Lee, Yong-joo;Kim, Nag-young;Ko, Sungil
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.3
    • /
    • pp.133-149
    • /
    • 2021
  • This study aims to report the behavioral mechanism of steel pipe reinforcement grouting, which is being actively used to ensure the stability of the excavation surface during tunnel excavation, based on measurements taken at the actual site. After using a 12 m steel pipe attached with a shape displacement meter and a strain gauge to reinforce the actual tunnel surface, behavioral characteristics were identified by analyzing the measured deformation and stress of the steel pipe. Taking into account that the steel pipes were overlapped every 6 m, the measured data up to 7 m of excavation were used. In addition, the behavioral characteristics of the steel pipe reinforcement according to the difference in strength were also examined by applying steel pipes with different allowable stresses (SGT275 and SGT550). As a result of analyzing the behavior of steel pipes for 7 hours after the first excavation for 1 m and before proceeding with the next excavation, the stress redistribution due to the arching effect caused by the excavation relaxation load was observed. As excavation proceeded by 1 m, the excavated section exhibited the greatest deformation during excavation of 4 to 6 m due to the stress distribution of the three-dimensional relaxation load, and deformation and stress were generated in the steel pipe installed in the ground ahead of the tunnel face. As a result of comparing the behavior of SGT275 steel pipe (yield strength 275 MPa) and SGT550 steel pipe (yield strength 550 MPa), the difference in the amount of deformation was up to 18 times and the stress was up to 12 times; the stronger the steel pipe, the better it was at responding to the relaxation load. In this study, the behavior mechanism of steel pipe reinforcement grouting in response to the arching effect due to the relaxation load was identified based on the measured data during the actual tunnel excavation, and the results were reported.

Evaluation of usefulness for Stereotactic Partial Breast Irradiation(S-PBI) by using Surface Fiducial Marker (표면위치표지자를 적용한 정위적 부분유방방사선치료의 유용성 평가)

  • Kim, JongYeol;Jung, DongMin;Kim, SeYoung;Yoo, HyunJong;Choi, JungHoan;Park, HyoKuk;Baek, JongGeol;Lee, SangKyu;Cho, JeongHee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.99-108
    • /
    • 2021
  • Purpose: The goal of this study is to evaluate usefulness of noninvasive method instead of previous inserting Fiducial Marker Method when performing Stereotactic Partial Breast Irradiation in CyberKnife. Material and methods: For consistency of Imaging Center, we evaluated both oblique images at angle 45 and 315 acquired from 2D Simulator and CyberKnife quantitatively through dice similarity coefficient. Also, location reproducibility of Surface Fiducial Marker was analyzed from 2D Simulator, treatment plans and CyberKinfe images by using 8 Fiducial Markers made of gold attached to ATOM Phantom based on our institution's protocols. Results: The results of the estimated consistency were 0.87 and 0.9 at the oblique angle 45 and 315, respectively. For location consistency of Surface Fiducial Markers, values of horizontal vertical direction of left breast were Superior/Inferior 0.3 mm, Left/Right -0.3 mm, Anterior/Posterior 0.4 mm, and the values of rotational direction were Roll 0.3 °, Pitch 0.2 °, Yaw 0.4 °. The values of horizontal vertical direction of right breast were Superior/Inferior -0.1 mm, Left/Right -0.1 mm, Anterior/Posterior -0.1 mm, and the values of rotational direction were Roll 0.2°, Pitch 0.1°, Yaw 0.1°. Conclusions: We expect that the protocols used by Surface Fiducial Markers when performing Stereotactic Partial Breast Irradiation in CyberKnife will provide protection from pain and cut expenses for treatment and reduce treatment errors and make treatment more accurate by suggesting treatment protocols based on high consistency of Imaging Center and reproducibility of Fiducial Markers.

A study on the effect of microgroove-fibronectin complex titanium plate on the expression of various cell behavior-related genes in human gingival fibroblasts (인간치은섬유아세포의 다양한 세포행동 관련 유전자발현에 마이크로그루브-파이브로넥틴 복합 티타늄표면이 미치는 영향에 대한 연구)

  • Hwang, Yu Jeong;Lee, Won Joong;Leesungbok, Richard;Lee, Suk Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.3
    • /
    • pp.150-161
    • /
    • 2022
  • Purpose: To determine the effects of the microgroove-fibronectin complex surface on the expression of various genes related to cellular activity in human gingival fibroblasts. Materials and Methods: Smooth titanium specimens (NE0), acid-treated titanium specimens (E0), microgroove and acid-treated titanium specimens (E60/10), fibronectin-fixed smooth titanium specimens (NE0FN), acid-treated and fibronectin-immobilized titanium specimens (E0FN), and microgroove and acid-treated titanium specimens immobilized with fibronectin (E60/10FN) were prepared. Real-time polymerase chain reaction experiments were conducted on 44 genes related to cell behavior of human gingival fibroblasts. Results: Adhesion and proliferation of human gingival fibroblast on microgroove-fibronectin complex titanium were activated through four types of signaling pathway. Integrin α5, Integrin β1, Integrin β3, Talin-2, which belong to the focal adhesion pathway, AKT1, AKT2, NF-κB, which belong to the PI3K-AKT signaling pathway, MEK2, ERK1, ERK2, which belong to the MAPK signaling pathway, and Cyclin D1, CDK4, CDK6 genes belonging to the cell cycle signaling pathway were upregulated on the microgroove-fibronectin complex titanium surface (E60/10FN). Conclusion: The microgroove-fibronectin complex titanium surface can up-regulate various genes involved in cell behavior.