Browse > Article

Evaluation of usefulness for Stereotactic Partial Breast Irradiation(S-PBI) by using Surface Fiducial Marker  

Kim, JongYeol (Department of Radiation Oncology, Yonsei Cancer Center)
Jung, DongMin (Department of Radiation Oncology, Yonsei Cancer Center)
Kim, SeYoung (Department of Radiation Oncology, Yonsei Cancer Center)
Yoo, HyunJong (Department of Radiation Oncology, Yonsei Cancer Center)
Choi, JungHoan (Department of Radiation Oncology, Yonsei Cancer Center)
Park, HyoKuk (Department of Radiation Oncology, Yonsei Cancer Center)
Baek, JongGeol (Department of Radiation Oncology, Yonsei Cancer Center)
Lee, SangKyu (Department of Radiation Oncology, Yonsei Cancer Center)
Cho, JeongHee (Department of Radiation Oncology, Yonsei Cancer Center)
Publication Information
The Journal of Korean Society for Radiation Therapy / v.33, no., 2021 , pp. 99-108 More about this Journal
Abstract
Purpose: The goal of this study is to evaluate usefulness of noninvasive method instead of previous inserting Fiducial Marker Method when performing Stereotactic Partial Breast Irradiation in CyberKnife. Material and methods: For consistency of Imaging Center, we evaluated both oblique images at angle 45 and 315 acquired from 2D Simulator and CyberKnife quantitatively through dice similarity coefficient. Also, location reproducibility of Surface Fiducial Marker was analyzed from 2D Simulator, treatment plans and CyberKinfe images by using 8 Fiducial Markers made of gold attached to ATOM Phantom based on our institution's protocols. Results: The results of the estimated consistency were 0.87 and 0.9 at the oblique angle 45 and 315, respectively. For location consistency of Surface Fiducial Markers, values of horizontal vertical direction of left breast were Superior/Inferior 0.3 mm, Left/Right -0.3 mm, Anterior/Posterior 0.4 mm, and the values of rotational direction were Roll 0.3 °, Pitch 0.2 °, Yaw 0.4 °. The values of horizontal vertical direction of right breast were Superior/Inferior -0.1 mm, Left/Right -0.1 mm, Anterior/Posterior -0.1 mm, and the values of rotational direction were Roll 0.2°, Pitch 0.1°, Yaw 0.1°. Conclusions: We expect that the protocols used by Surface Fiducial Markers when performing Stereotactic Partial Breast Irradiation in CyberKnife will provide protection from pain and cut expenses for treatment and reduce treatment errors and make treatment more accurate by suggesting treatment protocols based on high consistency of Imaging Center and reproducibility of Fiducial Markers.
Keywords
Cyberknife; Stereotactic Partial Breast Irradiation; Surface Fiducial Marker; Protocol;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Strnad V, Ott OJ, Hildebrandt G, et al.: 5-year results of accelerated partial breast irradiation using sole interstitial multicatheter brachytherapy versus whole-breast irradiation with boost after breast-conserving surgery for low-risk invasive and in-situ carcinoma of the female breast: a randomised, phase 3, non-inferiority trial. Lancet 2016;387(10015):229-38   DOI
2 Livi L, Meattini I, Marrazzo L, et al.: Accelerated partial breast irradiation using intensity-modulated radiotherapy versus whole breast irradiation: 5-year survival analysis of a phase 3 randomised controlled trial. Eur J Cancer 2015;51(4):451-63   DOI
3 Chang JH, Lee NK, Kim JY, et al.: Phase II trial of proton beam accelerated partial breast irradiation in breast cancer. Radiother Oncol 2013;108:209-214   DOI
4 Lozza L, Fariselli L, Sandri M, et al.: Partial breast irradiation with CyberKnife after breast conserving surgery: a pilot study in early breast cancer. Radiat Oncol 2018;13(1):49   DOI
5 Lee WH, "Developing a Novel High-precision Radiotherapy for Low Risk Early-stage Breast Cancer in Korean Women - Stereotactic Partial Breast Irradiation with CyberKnife M6." Dissertation, Seoul The Graduate School Yonsei University,2019.
6 Seiler S, Rahimi A, Choudhery S, et al.: Ultrasound-Guided Placement of Gold Fiducial Markers for Stereotactic Partial-Breast Irradiation. AJR Am J Roentgenol 2016;207(3):685-8   DOI
7 Accuray Inc. Treatment Delivery In. CyberKnife Treatment Delivery Manual. 2014;V10.x:5-21
8 Accuray Inc. Treatment Delivery In. CyberKnife Treatment Delivery Manual. 2014;V10.x:7-58,59
9 Hemmatazad H, Schmidhalter D, Elicin O, et al.: Herrmann E. Skin surface markers for stereotactic body radiation therapy of sternal metastasis. Rep Pract Oncol Radiother 2019;24(4):322-4   DOI
10 Kim JH, Hong SS, Kim JH, et al.: Safety and efficacy of ultrasound-guided Fiducial Marker implantation for CyberKnife radiation therapy. Korean J Radiol 2012;13(3):307-13   DOI
11 Dieterich S, Gibbs IC.: The CyberKnife in clinical use: current roles, future expectations. Front Radiat Ther Oncol 2011;43:181-94   DOI
12 Kelly HZ, Simon KW, Clare MCT, et al.: Statistical validation of image segmentation quality based on a spatial overlap index1: scientific reports. Academic radiology 2004;11.2:178-189   DOI
13 La Rocca E, Lozza L, D'Ippolito E, et al.: VMAT partial-breast irradiation: acute toxicity of hypofractionated schedules of 30 Gy in five daily fractions. Clinical and Translational Oncology 2020;22.10:1802-1808   DOI
14 Hui SK, Das RK, Kapatoes J, et al.: Helical tomotherapy as a means of delivering accelerated partial breast irradiation. Technol Cancer Res Treat 2004;3(6):639-46   DOI
15 Rault E, Lacornerie T, Dang HP, et al.: Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy. Radiat Oncol 2016;11:29   DOI
16 Lee CY, Kim WC, Kim HJ, et al.: Dosimetric Plan Comparison of Accelerated Partial Breast Irradiation (APBI) Using CyberKnife. Prog Med Phys 2018;29(2):73-80   DOI
17 Hong S, Won YJ, Park YR, et al.: Cancer statistics in Korea: incidence, mortality, survival, and prevalence in 2017. Cancer Res Treat 2020;52:335-350   DOI
18 Kim KJ, Suh CO. Partial breast cancer (PBI). J Korean Breast Cancer Soc 2004;7:65-71   DOI
19 Herskind C, Wenz F.: Radiobiological comparison of hypofractionated accelerated partial-breast irradiation (APBI) and single-dose intraoperative radiotherapy (IORT) with 50-kV X-rays. Strahlenther Onkol 2010;186:444-451   DOI
20 Baglan KL, Sharpe MB, Jaffray D, et al.: Accelerated partial breast irradiation using 3D conformal radiation therapy (3D-CRT). Int J Radiat Oncol Biol Phys 2003;55:02-311
21 Vermeulen SS, Haas JA.: CyberKnife stereotactic body radiotherapy and CyberKnife accelerated partial breast irradiation for the treatment of early breast cancer. Translational Cancer Research 2014;3(4):295-302
22 Obayomi-Davies O, Kole TP, Oppong B, et al.: Stereotactic Accelerated Partial Breast Irradiation for Early-Stage Breast Cancer: Rationale, Feasibility, and Early Experience Using the CyberKnife Radiosurgery Delivery Platform. Front Oncol 2016;6:129
23 Correa C, Harris EE, Leonardi MC, et al.: Accelerated Partial Breast Irradiation: Update of an ASTRO Evidence-Based Consensus Statement Conflict of Interest Disclosure Statement. Pract Radiat Oncol 2017;1-26
24 Rahimi A, Thomas K, Spangler A, et al.: Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation. Int J Radiat Oncol Biol Phys 2017;98(1):196-205   DOI