• Title/Summary/Keyword: 동적교정장치

Search Result 14, Processing Time 0.022 seconds

Calibration uncertainty of a spinning rotor gauge (스피닝 로터 게이지 교정 불확도)

  • 홍승수;임인태;신용현;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.1
    • /
    • pp.7-15
    • /
    • 2003
  • Spinning Rotor Gauge (SRG) has been used to transfer standard gauge for international comparison at the high vacuum standards. We calibrated a spinning rotor gauge by using dynamic calibration system (DCS) that was a national high vacuum standards system. And its uncertainties were evaluated with the International Organization for Standardization (ISO), they were recognized ai A type uncertainty, B type uncertainty, combined Standard uncertainty, and expanded uncertainty. The combined standard uncertainties were $1.8007\times10^{-5}$ Pa ~ ~$4.8422\times10^{-5}$ Pa for this spinning rotor gauge.

National Vacuum Standards from Low to Ultra-high Vacuum (저진공에서 초고진공까지의 국가 진공표준)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • Vacuum laboratory in Korea Research Institute of Standards and Science (KRISS) was opened in 1983 for establishing and disseminating vacuum standard in Korea. The major three systems such as the ultrasonic interferometer manometer (UIM), the static expansion system (SES) and the dynamic expansion system (DES) with orifice and porous plug conductance are developed. In this study, the standard systems from low to ultra-high vacuum, uncertainty analysis by ISO regulation, and key and bilateral comparison results will be described.

THE CHANCE OF TOOTH NOBILITY FOLLOWING ORTHODONTIC TOOTH MOVEMENT : A SHORT-TERM STUDY (교정적 치아이동 후 치아동요도 변화에 관한 연구)

  • Hwang, Hyeon-Shik;Kim, Jae-Hyuk;Choi, Joon-Kyu;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.379-389
    • /
    • 1998
  • The purpose of the present study was to evaluate the change of tooth mobility following orthodontic tooth movement. Six orthodontic patients which had been treated with edgewise appliance were used. Tooth mobility was measured with Periostest at the time of the removal of orthodontic appliance and 1, 2, 3, 4, 6, 8, 10, 12, 16, 20, 24 weeks after appliance removal. Following results were obtained: 1. Tooth mobility upon the removal of orthodontic appliance showed individual variation while incisor showed greater mobility than the other teeth. 2. Tooth mobility showed continued decrease pattern until 24 weeks after appliance removal. 3. While maxillary incisors showed continued decrease pattern during the study period, the other teeth showed steep decline pattern during the first 12 weeks and gentle slope during the second 12 weeks. 4. The tooth mobility of the maxillary second premolar showed the most typical change in terms of the consistency of the decline. 5. There were no significant differences of tooth mobility between heavy- and light-contacted anterior teeth during experimental period. The results of the present study suggested that periodontal reorganization is not completed even in 24 weeks following orthodontic tooth movement.

  • PDF

AN EXPERIMENTAL STUDY ON THE DYNAMIC 700TH MOVING EFFECTS OF TWO PRECIS10N LINGUAL ARCHS(PLA) FOR CORRECTION OF POSTER10R SCISSOR BITE BY THE CALORIFIC MACHINE (두 종류의 Precision Lingual Arch(PLA)로 구치부 교차교합 치료시 발생할 동적인 치아이동 양상의 차이를 Calorific Machine으로 실험한 연구)

  • Chun, Youn-Sic;Row, Joon;Suh, Moon-Suk;Park, In-Kwon
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.29-41
    • /
    • 1998
  • Despite orthodontic treatment(tooth moving) is dynamic act many orthodontists have used mainly static evaluation method for evaluating effectiveness of the orthodontic appliances. They want to find which is better appliance, especially in the treatment results and treatment period when they chose one appliance from sugessted appliances for obtaining same treatment goal. The author and colleagues invented and manufactured new machine for getting information about the relative effectiveness from many suggested orthodontic appliances and we named it Calorific machine. We used this Calorinc machine to find the relative differences about tooth moving mechanism and tooth moving time between the Burstone's PLA(single force mechanism) and Molar-up's PLA(couple mechanism) for correcting the posterior cross bite. We measured the distance of tooth moving on the occlusal X-ray film and recorded the moving time of the anchored(control elctro-thermal tooth) and lingually tipped lower second molars(experimental electro-thermal tooth) and then processed paired t-est by SAS program. The results were as follows. 1. Molar-up's PLA showed more extrusive and horizontal movement than Burstone's PLA at the lingually tipped molar(p=0.0000). 2. There is no finding of tooth movement by Molar-up's PLA at the uprighted molar(p=o.3475) but Burstone's PLA showed a little change(0.2 m) at the same molar(p=0.0001). 3. Burstone's PLA took 17.8 minutes for tooth moving but Molar-up's PLA took only 3.8 minutes(p=0.0001)

  • PDF

A Study of the design method for Interactive squat exercise Instrument (인터렉티브 스쿼트운동기구의 설계방법에 관한 연구)

  • Jeong, Byeong-Ho;Park, Ju-Hoon;Kim, Ji-won
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.2
    • /
    • pp.303-311
    • /
    • 2018
  • Squat exercise is one of the free weight exercises that are recognized as important from a bio-mechanical point of view. It is an important exercise to train lower extremity muscles in daily activities or sports activities and to strengthen trunk and lower body strength. It is effective and accurate to use a variety of assistive devices to calibrate athletic posture with squat exercise supported interactive device. The issues of the structural analysis for design a foot plate for squat exercise is to model the behavior by simplifying the dynamic behavior. In this paper, the authors proposed a exercise system design method for the vertical load distribution and bio-mechanical signal process used for the squat exercise mechanism analysis, and based on these results, designed device can make the more safe and reliable free weight exercise. It is applied to system design through design method with kinematic dynamic, VR device and estimation model of exercise.

Changes in KVA Resulting from Correction Condition of Refractive Error (굴절이상 교정상태에 따른 동적시력 변화)

  • Shim, Hyun-Suk;Kim, Sang-Hyun;Kang, Hye-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.165-171
    • /
    • 2013
  • Purpose: This study are to analyze and to compare between pupillary size, reaction time, refractive error, corrected vision, dominant eye, static visual angle (SVA) and kinetic visual acuity (KVA) of male and female college students, to measure KVA of them in full correction and to identify changes of KVA by +0.50 D and -0.50 D spherical power addition respectively in full correction condition. Methods: KVA, SVA, pupillary size, reaction time, refractive error, corrected vision and dominant eye of 40 male and 40 female optical science students were measured by utilizing KOWA AS-4A, reaction time measurement program, subjective refractometer, and objective refractometer, and KVAs were measured when +0.50 D/-0.50 D were added in both eyes respectively. Results: Binocular KVA of whole subjects was $0.45{\pm}0.22$, and in monocular KVAs were $0.36{\pm}0.19$ for right eye and $0.34{\pm}0.19$ for left eye, and binocular KVA was significantly higher than monocular KVA. It appeared that the better SVA was, the better KVA was in significant way, and in terms of refractive error the less myopia amount was, the better KVA was, but it was not significant statistically. The lower astigmatism was, the slightly and significantly higher KVA was when dividing between equal or less than -1.00 D astigmatism group and over -1.00 D astigmatism group. In resulting from correction condition of refractive error KVAs were $0.45{\pm}0.22$ for full correction, $0.26{\pm}0.15$ for +0.50 D addition, $0.48{\pm}0.22$ for -0.50 D addition which indicates that KVA in over myopia correction was significantly the highest and followed by full correction and under correction. Similar findings were revealed in both male and female, and KVA of male was better than female in comparing between male and female. There was no significantly different KVA between dominant eye and non-dominant eye. Conclusions: Accordingly, it is concluded that KVA is related with far distance SVA, astigmatism amount, and refractive error amount except a dominant eye. Through this research, it was found that prescription for enhancing KVA is to make full correction or to overcorrect slightly myopia.

A Study of Dynamic Motion Analysis Device for Free Weight Exercise (프리웨이트운동의 동적 동작분석장치에 관한 연구)

  • Rahman, Mustafizur;Park, Ju-hoon;Kim, Ji-won;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.2
    • /
    • pp.271-279
    • /
    • 2020
  • Squats and lunges are important exercises for strengthening the trunk and lower body among various free weight exercises. It should be achieved safe and effective excise through establishing of theoretical basis for exercise posture and standard movement. Therefore, it's necessary to develop the exercise model in order to prepare the scientific countermeasures for the prevent injuries and error movement through optimal exercise movement. For this purpose, it is effective to use appropriate instruments for motion compensation according to the optical motion and error motion. In this paper, we develop a motion model analysis system based on dynamic motion through the four-point load cell for dynamic motion analysis. Proposed analytical method, the optimal and the error motion numerical data is obtained through the dynamic motion analysis. And we verified that dynamic movement is simplified to establish the motion modeling according to the classification motion and the numerical quantification data for analyzing.

Generation of calibration standard gases using capillary gas divider: uncertainty measurement and method validation (다중 모세관을 이용한 교정용 표준가스의 제조: 불확도와 유효성 평가)

  • Lee, Sangyun;Hwang, Eun-Jin;Jung, Hye-Ja;Lee, Kwang-Woo;Chun, Ki-Joon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.369-375
    • /
    • 2006
  • Calibration gas mixtures were prepared using dynamic volumetric method according to ISO 6145-5 and the uncertainty was evaluated. Ten identical capillaries with 0.25 mm in inner diameter and 50 cm in length were applied in this system. Dilution ratio of parent gas was determined by the number of capillaries that passes parent gas and that passes balance gas through. Capillaries were made of Teflon which had good chemical stability against adsorption of gaseous substances. Mechanical valves were introduced in this system in order to minimize the thermal effect of solenoid valves. Concentration of prepared gases were compared with master grade standard gases in cylinders made by RiGAS Co. and calibration of the instrument were completed using comparison method according to ISO 6143. Experimental results showed that the coefficient of variance of diluted oxygen standard gases showed less then 0.2% in most dilution range, that of diluted hydrogen sulfide standard gases showed less then 1.0%. Therefore, it is proven that the standard gases prepared by this system are appropriate to be used as a calibration standards in ambient monitoring, etc.

A monopulse radar uncertainty study classified on target property (표적 특성에 따른 모노펄스 레이더 불확도 연구)

  • Jang, Yong-sik;Ryu, Chung-ho;Kim, Whan-woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.229-236
    • /
    • 2017
  • In general, an error budget of monopulse radar is proposed by manufacturer who assuming that all of external enviromental error resources such as multipath, glint, dynamic lag variation are removed. So until now, a measurement uncertainty of monopulse radar can be discussed including external enviromental error resources. In this paper, it is described that which kinds of error resource can effect on monopulse radar measurement uncertainty for different target property. To prove it experimentally, at first a simulation result is described assuming that all of external enviromental error resources are removed. It only includes receiver thermal noise. And then, monopulse radar measurement uncertainty estimation results tracking on calibration target which is fixed on specific position, calibration sphere which is moving slowly, weapon systems firing test which is moving fast are described quantitativly. All of these targets have different dynamic property.

The Comparative Assessment of the KVA and Dynamic Stereoacuity (동적시력(KVA)과 동적 입체시의 비교 평가)

  • Kim, Young-Cheong;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • Purpose: On this study, we investigated the relationship between the kinetic visual acuity (KVA) and the dynamic stereoacuity and the effects of anisometropia with measuring KVA and the dynamic stereoacuity. Methods: For 63 adults (male 30, female 33), KVA and the dynamic stereoacuity were measured by using the kinetic visual acuity tester (KOWA AS-4A) and the Howard-Dolman test (H-D test) at distance 2.5 m after conducted full correction of subjects' refractive error respectly. Results: The means of KVA were $0.49{\pm}0.25$ for total subjects, $0.58{\pm}0.26$ for male, $0.40{\pm}0.22$ for female, and LogMAD (Log minimum angle of displacement) dynamic stereoacuities were $1.27{\pm}0.44$($28.44{\pm}25.03sec$ of arc) for total subjects, $1.28{\pm}0.44$($28.23{\pm}23.34sec$ of arc) for male, $1.27{\pm}0.45$($28.63{\pm}26.83sec$ of arc) for female. KVA showed a statistically significant difference between male and female (p=0.00), but dynamic stereoacuity was no significant difference (p=0.97). No significant correlation was present between KVA and dynamic stereoacuity (r=0.03). Also there were no significant differences in the dynamic stereoacuity of the three group which were classified according to the low, middle, high range of KVA (p=0.99). The anisometropia were less than 1 D and over 1 D when divided into two groups, KVA and dynamic stereoacuity showed no significant difference between each (p=0.11, p=0.99). There was no significant correlation between anisometropia and KVA (r=0.33), dynamic stereoacuity (r=0.18) but the correlation between KVA and anisometropia revealed more higer than between dynamic stereoacuity and anisometropia. Conculsions: The KVA for adults showed a significant difference between male and female and male was higher than female for KVA. The dynamic stereoacuity due to the KVA, the KVA and dynamic stereoacuity due to anisometropia were not significant differences between each and also were not great correlations.