• Title/Summary/Keyword: 내면적합도

Search Result 83, Processing Time 0.03 seconds

Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system (치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교)

  • Lee, Wan-Sun;Park, Jong-Kyoung;Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2014
  • Purpose: The purpose of this study was to assess the marginal and mesial fitness of zirconia single copings and 3-unit fixed partial dentures (FPDs) manufactured with an identical model. Materials and Methods: An epoxy model in which the maxillary right 2nd premolar is lost and maxillary 1st premolar and 2nd molar are formed as abutments was manufactured and scanned by using a laser scanner. A ten units of zirconia single copings were manufactured for maxillary 1st premolar and 2nd molar, respectively and the same number of 3-unit FPDs were manufactured. For the measurements of fitness, the manufactured silicone replicas were divided into four parts and the fitness were measured by digital microscope at measurement points (P1, P2, P3, P4 and P5) of each plane. The measured gaps were classified into three categories: marginal gap (MG, P1), axial gap (AG, average of P2 and P3), occlusal gap (OG, average of P4 and P5). Results: The ranges of MG, AG and OG for single copings were 18.47 - 40.54 ${\mu}m$, 39.73 - 73.61 ${\mu}m$ and 116.90 - 134.69 ${\mu}m$, respectively. The ranges of MG, AG and OG for 3-unit FPDs were 45.95 - 87.44 ${\mu}m$, 23.78 - 57.00 ${\mu}m$ and 99.89 - 131.06 ${\mu}m$, respectively. Conclusion: The result of the study shows that the MGs for 3-unit FPDs were higher than those of single copings, though they are within the range of clinical acceptance, indicating that the use of more homogeneous zirconia block and modification of sintering processes are needed to ensure the prevention of increase of gap in 3-unit FPDs.

Comparison of the Marginal and Internal Fit on the Cast and CAD-CAM Cores (주조에 의한 Core와 CAD-CAM에 의한 Core의 적합도 비교평가)

  • Han, Man-So;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.368-374
    • /
    • 2012
  • Dental CAD (computer-aided design)/CAM (computer-aided manufacturing) systems facilitate the use of zirconia core for all-ceramic crown. The purpose of this study was to evaluate the marginal and internal fit of zirconia core fabricated using a dental CAD/CAM system and to compare the fit of metal cores by a conventional method. Ten identical cases of single coping study models (abutment of teeth 11) were manufactured and scanned. Ten zirconia cores were fabricated using dental CAD/CAM system. An experienced dental technician fabricated 10 samples of metal cores for the control group using the lost wax technique. Marginal and internal fit was measured by the silicone replica technique. Fit was measured with magnification of 160 using a digital Microscope. Margin, rounded chamfer, axial wall and incisal fits were measured for comparison. T-test of independent sample for statistical analysis was executed with SPSS 12.0 for Windows (SPSS Inc., Chicago, IL, USA) (${\alpha}$=0.05). The mean (SD) for marginal, rounded chamfer, axial wall and incisal were: $97.0\;(25.3){\mu}m$, $104.0\;(22.0){\mu}m$, $59.6\;(21.4){\mu}m$ and $124.8\;(33.3){\mu}m$ for the zirconia core group, and $785.2\;(18.4){\mu}m$, $83.8\;(15.1){\mu}m$, $42.7\;(9.6){\mu}m$ and $83.4\;(14.4){\mu}m$ for the metal core group. T-test showed significant differences between groups for margin (p<.001), rounded chamfer (p<.001), axial wall (p<.001) and incisal (p<.001). But zirconia core group observed that the marginal and internal fit values in the present study were within clinically acceptable range.

Artificial Trachea Covered by Ipithelium (상피세포 피복 인공기관의 개발)

  • 김광택;이윤신
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.739-746
    • /
    • 1997
  • A variety of experiments concerning the development of ideal prosthetic grafts for correcting circumferential tracheal defects have been performed. The requirements for an ideal tracheal prosthesis are impermeability to air, consistency to prevent collapse, and acceptance by the host tissue causing a minimum inflammatory reaction, allowing fibroblastic infiltration and epithelialization. The synthetic material, polyurethane(PU), is known as a biocompatible polymer with an inert component. In this study, the tracheal prosthesis was made from microporous PU(30 micrometer in diameter) coated with gelatin and reinforced with isoplastic rings. This procedure provides the prosthesis with a compression strength. The out side diame er of the prosthesis was 20 mm with a length of 30 mm. The gelatin used in the study was obtained from pig skin and immobilized and cross-linked by irradiation(60 Co gamma ray) to promote host tissue incorporation and render the prosthesis epithelization after implantation. Animal experiments using 10 mongrel dogs were performed to compare three kinds of prosthesis; gelatin coated polyurethane graft, uncoated polyurethane graft, and prosthesisf pericadium complex graft. After 6 weeks of implantation, the epithelialization of implants was seen on the gelatin-coated and prosthesisfpericadium complex grafts. Implanted prosthesis were complicated by airway obstruction due to anastomosis granuloma. Early tracheal stenosis was found in the uncoated graft group. Two kind of anastomosis techniques were tested on the gelatin-coated prosthesis. Everted anastomosis resulted severe granuloma than the inverted anastomosis. In the prosthesislpericadium complex graft, bacteria and inflammation at a anastomotic site was found. Based on these results, gelatin coated porous polyurethane trachea prosthesis is biocompatible and may be useful in clinical application with further investigation.

  • PDF

A Phenomenological Study On the Characterization Experience of Middle-aged Woman using Mandala Arts Treatment (만다라 미술치료를 활용한 중년기 여성의 개성화 경험에 관한 현상학 연구)

  • Kim, Ki-Uk;Shin, Dong-Yeol
    • Industry Promotion Research
    • /
    • v.5 no.2
    • /
    • pp.33-40
    • /
    • 2020
  • When most middle-aged women live in a time when they have to take responsibility for their lives, they feel lonely when they realize that their experience of not expressing their feelings properly has ended up being left alone due to their own existence and loss. As the first step in conscious awareness of unconsciousness of middle-aged women through analytical psychology, we performed "Mandara" and "Nanhwa Mandara," which meet me inside. The intermediate stage can be divided into transition and work phase. The working phase, develops one's own advantages and unique strengths that meet the inner world of promoting and acting values, correctly looks at reality, corrects emotion perception and balance, and is self-contained, seed mandala, associative mandala. They performed the strong points of mandala, the free mandala, and the Western mandala. The results of the study showed that mandala art therapy was found in middle-aged women. First, Mandarin art therapy experience affects the physical, psychological and human relations aspects of middle-aged women. Second, middle-aged women's experience of individualization through mandala art therapy shows psychological reversals and affects positive thinking and self-effectiveness. This study was suitable for qualitative research that approached the essence through practical understanding and direct exploration of research participants, and it is meaningful to suggest that it is necessary to develop an art therapy program through various mediums considering the lack of art therapy research in middle-aged women and problems experienced by the physician.

Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods (서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성)

  • Cho, Young Beom;Chae, Heon Chung;Kim, Hee Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.366-376
    • /
    • 2013
  • The purpose of this study is to evaluate the marginal and internal fit of coping made by CAD/CAM using different scanning methods. Zirconia coping was made by each CAD/CAM system followed by intra-oral scanning, model optical scanning and model contact scanning. It was embedded into Epoxy Resin and was cut by buccal to lingual. AMD (Absolute marginal discrepancy), MG (Marginal gap), GA (Gap of axial), GL (Gap of line angle) and GO (Gap of occlusal) of each sample were measured. The result is as followed; 1. The mean value of AMD in Group 1, Group 2, Group 3 are $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$. The averages of MG in Group 1, Group 2, Group 3 are $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$. Statistically there is no difference in AMD and MG among the three Groups (Anova, P>0.05). 2. GA of Group 2 revealed statistically difference compared with Group 1 and Group 3 (Anova, P<0.05). 3. GL and GO of Group 1 showed statistically significant differences compared with Group 2 and Group 3 (Mann-whitney test (P<0.05). Zirconia copings made by 3 ways of scanning methods have no difference with conventional ceramics in AMD and MG which are known as the most important factors.

Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system (가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교)

  • Wan-Sun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.72-81
    • /
    • 2024
  • Purpose: This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removable die system. Materials and Methods: The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RD group) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scanner to establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAM milling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05). Results: The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions. Conclusion: The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.

Human Image Analysis Through Fashion Color of Female Political Leaders (여성정치지도자의 패션컬러를 통해 본 휴먼이미지 연구)

  • Kim, Se-A;Jang, Seong-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.12
    • /
    • pp.247-256
    • /
    • 2017
  • 21st century has become an era can design human's image. By designing the each human's images it is possible to express the hidden abilities of their mind. Modern society changes rapidly where the elements such as consideration, sympathy, understandings, and female leadership of communication emerge as a spur rather than speediness or complexity.In a lot of global conglomerates, it is very common for women to be selected as CEO, and even more, the rate of woman who are the member of Congress is almost 40%. The fashion of female leader has come to the fore with an improvement of female leadership, and the fashion colour which is suitable to P.O has been developed as a significant image strategy. I am going to conduct the research and analyse the fashion of a female political leader through the colour image which is equivalent to a visual image and sensitive language. I will analyze the human image which female leaders present through fashion colors.

Structural Relationship between Adolescent Athletes' Positive Thinking, Coping Flexibility, and Burnout (청소년 운동선수들의 긍정적 사고와 대처유연성 및 소진의 구조적 관계)

  • Song, Ki-Hyun;Kim, Seung-Yong
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.2
    • /
    • pp.281-288
    • /
    • 2020
  • The objective of the study was to identify the structural relationship between adolescent athletes'positive thinking and coping flexibility, burnout. In order to achieve such research goal, male and female athletes'from physical education middle and high schools across the nation were recruited; using a convenience sampling method, a total of 333 samples were selected as the final effective samples. The data went through a goodness-of-fit test for the whole model using SPSS 20.0 and AMOS 20.0 and a hypothesis test. The result is as follows: first, positive thinking was revealed to have significant influence on coping flexibility. second, repertories and flexible a subfactor of coping flexibility, had significant negative (-) effects on burnout, whereas reflective had no significant effects on it. Third, positive thinking was revealed to have no significant influence on burnout. In conclusion, although positive thinking is a variable that is based on internal information, positive thinking did not directly affect psychological burnout, but coping flexibility can be used to prevent burnout.

Analysis on the book cover design using Roland Barthes' Semiotics (롤랑바르트의 기호학을 이용한 추상적 책표지 디자인에 관한 분석)

  • Lee, Eunyoung;Kim, Boyeun
    • Journal of Digital Convergence
    • /
    • v.18 no.3
    • /
    • pp.357-362
    • /
    • 2020
  • By analyzing abstract book cover design, this study aims to examine the applicability of the semiotic methodology of Roland Barthes and to conduct a preference survey of how people would accept it. The selected books for the study are and published in Openbooks publishing company to mark the 30th anniversary of the opening. The research results are as follows. First, it was confirmed that Roland Barthes' semiotic approach is a suitable tool for identifying the symbolic phenomena of visual elements that constitute abstract book cover design. Second, people were well informed of what the abstract form of design conveys, but they showed personal differences in preference, making it difficult to achieve clear results. This study, together with the importance of the internal meaning that appears in the book cover design, gives graphic designers an indication that interaction between the communicator and the acceptor should be sought.

Evaluation of internal adaptation of PMMA 3-unit bridge manufactured by 5-axis milling machine (5축 밀링으로 가공한 PMMA 3본 브릿지의 내면 적합도 평가)

  • Kim, Chong-Myeong;Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.63-68
    • /
    • 2016
  • Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results: $RMS{\pm}SD$ values for PRE group, MOL group, and BRI group were $51.2{\pm}18.2$, $44.8{\pm}10.0$, and $52.1{\pm}8.3{\mu}m$, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05). Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.