• 제목/요약/키워드: $Fix_a(L)$

검색결과 42건 처리시간 0.022초

SYMMETRIC BI-(f, g)-DERIVATIONS IN LATTICES

  • Kim, Kyung Ho;Lee, Yong Hoon
    • 충청수학회지
    • /
    • 제29권3호
    • /
    • pp.491-502
    • /
    • 2016
  • In this paper, as a generalization of symmetric bi-derivations and symmetric bi-f-derivations of a lattice, we introduce the notion of symmetric bi-(f, g)-derivations of a lattice. Also, we define the isotone symmetric bi-(f, g)-derivation and obtain some interesting results about isotone. Using the notion of $Fix_a(L)$ and KerD, we give some characterization of symmetric bi-(f, g)-derivations in a lattice.

전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가 (Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography)

  • 김정진;장성원;박장흠;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

ON SYMMETRIC BI-GENERALIZED DERIVATIONS OF LATTICE IMPLICATION ALGEBRAS

  • Kim, Kyung Ho
    • 충청수학회지
    • /
    • 제32권2호
    • /
    • pp.179-189
    • /
    • 2019
  • In this paper, we introduce the notion of symmetric bi-generalized derivation of lattice implication algebra L and investigated some related properties. Also, we prove that a map $F:L{\times}L{\rightarrow}L$ is a symmetric bi-generalized derivation associated with symmetric bi-derivation D on L if and only if F is a symmetric map and it satisfies $F(x{\rightarrow}y,z)=x{\rightarrow}F(y,z)$ for all $x,y,z{\in}L$.

인천국제공항과 김포국제공항의 비행 절차 위험도 분석 (Risk Analysis of Flight Procedures at Incheon International Airport and Gimpo International Airport)

  • 이현웅;이학태
    • 한국항행학회논문지
    • /
    • 제24권6호
    • /
    • pp.500-507
    • /
    • 2020
  • 본 논문은 기록된 항적 데이터를 이용하여 혼잡한 공항의 비행 절차별 위험도를 분석하는 방법론을 제시하고, ADS-B (automatic dependent surveillance-broadcast) 데이터를 기반으로 재생성된 100일 치의 항적 데이터를 사용하여 인천국제공항과 김포국제공항의 비행 절차별 위험도를 분석한 결과를 보여준다. 위험도 분석은 DWC (detect and void well clear) 를 이용하였으며, 이를 통해 비행 절차별로 가장 높은 위험도가 나타나는 구간과 위험 발생이 잦은 구간을 평가하였다. 그 결과, 인천국제공항의 표준계기출발절차 중 RNAV BOPTA 1L의 SI712 - RANOS Fix 구간에서 가장 높은 위험도가 나타났으며, 표준계기도착절차 중에서는 RNAV GUKDO 1N에서는 SI947-DANAN Fix 구간에서 가장 높은 위험도가 나타났다. 또한 김포국제공항의 표준계기출발절차 중에서는 RNAV BULTI 1X의 SS726 - SS727 Fix, 표준계기도착절차 중에서는 RNAV OLMEN 1D의 KAKSO - KALMA Fix 구간에서 가장 높은 위험도가 나타났다.

A tightness theorem for product partial sum processes indexed by sets

  • Hong, Dug-Hun;Kwon, Joong-Sung
    • 대한수학회지
    • /
    • 제32권1호
    • /
    • pp.141-149
    • /
    • 1995
  • Let N denote the set of positive integers. Fix $d_1, d_2 \in N with d = d_1 + d_2$. Let X and Y be real random variables and let ${X_i : i \in N^d_1} and {Y_j : j \in N^d_2}$ be independent families of independent identically distributed random variables with $L(X) = L(X_i) and L(Y) = L(Y_j)$, where $L(\cdot)$ denote the law of $\cdot$.

  • PDF

VARIOUS CENTROIDS AND SOME CHARACTERIZATIONS OF CATENARY CURVES

  • Bang, Shin-Ok;Kim, Dong-Soo;Yoon, Dae Won
    • 대한수학회논문집
    • /
    • 제33권1호
    • /
    • pp.237-245
    • /
    • 2018
  • For every interval [a, b], we denote by $({\bar{x}}_A,{\bar{y}}_A)$ and $({\bar{x}}_L,{\bar{y}}_L)$ the geometric centroid of the area under a catenary curve y = k cosh((x-c)/k) defined on this interval and the centroid of the curve itself, respectively. Then, it is well-known that ${\bar{x}}_L={\bar{x}}_A$ and ${\bar{y}}_L=2{\bar{y}}_A$. In this paper, we fix an end point, say 0, and we show that one of ${\bar{x}}_L={\bar{x}}_A$ and ${\bar{y}}_L=2{\bar{y}}_A$ for every interval with an end point 0 characterizes the family of catenaries among nonconstant $C^2$ functions.

DERIVATIONS OF UP-ALGEBRAS

  • Sawika, Kaewta;Intasan, Rossukon;Kaewwasri, Arocha;Iampan, Aiyared
    • Korean Journal of Mathematics
    • /
    • 제24권3호
    • /
    • pp.345-367
    • /
    • 2016
  • The concept of derivations of BCI-algebras was first introduced by Jun and Xin. In this paper, we introduce the notions of (l, r)-derivations, (r, l)-derivations and derivations of UP-algebras and investigate some related properties. In addition, we define two subsets $Ker_d(A)$ and $Fix_d(A)$ for some derivation d of a UP-algebra A, and we consider some properties of these as well.