• Title/Summary/Keyword: ${\gamma}$-set

Search Result 290, Processing Time 0.024 seconds

SEVERAL KINDS OF INTUITIONISTIC FUZZY OPEN SETS AND INTUITIONISTIC FUZZY INTERIORS

  • Kim, Chang-Su;Kang, Jeong-Gi;Kim, Myoung-Jo;Ko, Mi-Young;Park, Mi-Ran
    • Honam Mathematical Journal
    • /
    • v.32 no.2
    • /
    • pp.307-331
    • /
    • 2010
  • The notion of intuitionistic fuzzy semi-pre interior (semi-pre closure) is introduced, and several related properties are investigated. Characterizations of an intuitionistic fuzzy regular open set, an intuitionistic fuzzy semi-open set and an intuitionistic fuzzy ${\gamma}$-open set are provided. A method to make an intuitionistic fuzzy regular open set (resp. intuitionistic fuzzy regular closed set) is established. A relation between an intuitionistic fuzzy ${\gamma}$-open set and an intuitionistic fuzzy semi-preopen set is considered. A condition for an intuitionistic fuzzy set to be an intuitionistic fuzzy ${\gamma}$-open set is discussed.

On Comaximal Graphs of Near-rings

Fuzzy γ-Quasi Open Set and Fuzzy γ-Quasi Continuity

  • Min, Won-Keun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.10 no.3
    • /
    • pp.200-202
    • /
    • 2010
  • In this paper, we introduce the concept of fuzzy ${\gamma}$-quasi open sets which are generalizations of fuzzy ${\gamma}$-open sets, and obtain some basic properties of such fuzzy sets. Also we introduce and study the concepts of fuzzy ${\gamma}$-quasi continuous mapping and fuzzy ${\gamma}$-quasi open(closed) mapping.

CONFORMAL DENSITY OF VISIBILITY MANIFOLD

  • Kim, Hyun-Jung
    • Bulletin of the Korean Mathematical Society
    • /
    • v.38 no.1
    • /
    • pp.211-222
    • /
    • 2001
  • In this paper, we prove the existence and uniqueness of a $\delta(\Gamma)$-conformal density on the limit set of $\Gamma$ acting on visibility manifold H for a Fuchsian group $\Gamma$.

  • PDF

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

ON A CLASS OF $\gamma$-PREOPEN SETS IN A TOPOLOGICAL SPACE

  • Krishnan, G. Sal Sundara;Balachandran, K.
    • East Asian mathematical journal
    • /
    • v.22 no.2
    • /
    • pp.131-149
    • /
    • 2006
  • In this paper we introduce the concept of $\gamma$-preopen sets in a topological space together with its corresponding $\gamma$-preclosure and $\gamma$-preinterior operators and a new class of topology $\tau_{{\gamma}p}$ which is generated by the class of $\gamma$-preopen sets. Also we introduce $\gamma$-pre $T_i$ spaces(i=0, $\frac{1}{2}$, 1, 2) and study some of its properties and we proved that if $\gamma$ is a regular operation, then$(X,\;{\tau}_{{\gamma}p})$ is a $\gamma$-pre $T\frac{1}{2}$ space. Finally we introduce $(\gamma,\;\beta)$-precontinuous mappings and study some of its properties.

  • PDF

OVERRINGS OF THE KRONECKER FUNCTION RING Kr(D, *) OF A PRUFER *-MULTIPLICATION DOMAIN D

  • Chang, Gyu-Whan
    • Bulletin of the Korean Mathematical Society
    • /
    • v.46 no.5
    • /
    • pp.1013-1018
    • /
    • 2009
  • Let * be an e.a.b. star operation on an integrally closed domain D, and let $K\gamma$(D, *) be the Kronecker function ring of D. We show that if D is a P*MD, then the mapping $D_{\alpha}{\mapsto}K{\gamma}(D_{\alpha},\;{\upsilon})$ is a bijection from the set {$D_{\alpha}$} of *-linked overrings of D into the set of overrings of $K{\gamma}(D,\;{\upsilon})$. This is a generalization of [5, Proposition 32.19] that if D is a Pr$\ddot{u}$fer domain, then the mapping $D_{\alpha}{\mapsto}K_{\gamma}(D_{\alpha},\;b)$ is a one-to-one mapping from the set {$D_{\alpha}$} of overrings of D onto the set of overrings of $K_{\gamma}$(D, b).

THE CONNECTED SUBGRAPH OF THE TORSION GRAPH OF A MODULE

  • Ghalandarzadeh, Shaban;Rad, Parastoo Malakooti;Shirinkam, Sara
    • Journal of the Korean Mathematical Society
    • /
    • v.49 no.5
    • /
    • pp.1031-1051
    • /
    • 2012
  • In this paper, we will investigate the concept of the torsion-graph of an R-module M, in which the set $T(M)^*$ makes up the vertices of the corresponding torsion graph, ${\Gamma}(M)$, with any two distinct vertices forming an edge if $[x:M][y:M]M=0$. We prove that, if ${\Gamma}(M)$ contains a cycle, then $gr({\Gamma}(M)){\leq}4$ and ${\Gamma}(M)$ has a connected induced subgraph ${\overline{\Gamma}}(M)$ with vertex set $\{m{\in}T(M)^*{\mid}Ann(m)M{\neq}0\}$ and diam$({\overline{\Gamma}}(M)){\leq}3$. Moreover, if M is a multiplication R-module, then ${\overline{\Gamma}}(M)$ is a maximal connected subgraph of ${\Gamma}(M)$. Also ${\overline{\Gamma}}(M)$ and ${\overline{\Gamma}}(S^{-1}M)$ are isomorphic graphs, where $S=R{\backslash}Z(M)$. Furthermore, we show that, if ${\overline{\Gamma}}(M)$ is uniquely complemented, then $S^{-1}M$ is a von Neumann regular module or ${\overline{\Gamma}}(M)$ is a star graph.

The Development of Gamma Energy Identifying Algorithm for Compact Radiation Sensors Using Stepwise Refinement Technique

  • Yoo, Hyunjun;Kim, Yewon;Kim, Hyunduk;Yi, Yun;Cho, Gyuseong
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.91-97
    • /
    • 2017
  • Background: A gamma energy identifying algorithm using spectral decomposition combined with smoothing method was suggested to confirm the existence of the artificial radio isotopes. The algorithm is composed by original pattern recognition method and smoothing method to enhance the performance to identify gamma energy of radiation sensors that have low energy resolution. Materials and Methods: The gamma energy identifying algorithm for the compact radiation sensor is a three-step of refinement process. Firstly, the magnitude set is calculated by the original spectral decomposition. Secondly, the magnitude of modeling error in the magnitude set is reduced by the smoothing method. Thirdly, the expected gamma energy is finally decided based on the enhanced magnitude set as a result of the spectral decomposition with the smoothing method. The algorithm was optimized for the designed radiation sensor composed of a CsI (Tl) scintillator and a silicon pin diode. Results and Discussion: The two performance parameters used to estimate the algorithm are the accuracy of expected gamma energy and the number of repeated calculations. The original gamma energy was accurately identified with the single energy of gamma radiation by adapting this modeling error reduction method. Also the average error decreased by half with the multi energies of gamma radiation in comparison to the original spectral decomposition. In addition, the number of repeated calculations also decreased by half even in low fluence conditions under $10^4$ ($/0.09cm^2$ of the scintillator surface). Conclusion: Through the development of this algorithm, we have confirmed the possibility of developing a product that can identify artificial radionuclides nearby using inexpensive radiation sensors that are easy to use by the public. Therefore, it can contribute to reduce the anxiety of the public exposure by determining the presence of artificial radionuclides in the vicinity.