Proceedings of the Earthquake Engineering Society of Korea Conference (한국지진공학회:학술대회논문집)
Earthquake Engineering Society of Korea (EESK)
- 기타
Domain
- Earth Science(Earth/Atmosphere/Marine/Astronomy) > Geophysics
2006.03a
-
We present a imaging method of seismic sources by time reversal propagation of seismic waves. Time-reversal wave propagation is actively used in medical imaging, non destructive testing and waveform tomography. Time-reversal wave propagation is based on the time-reversal invariance and the spatial reciprocity of the wave equation. A signal is recorded by an array of receivers, time-reversed and then back-propagated into the medium. The time-reversed signal propagates back into the same medium and the energy refocuses back at the source location. The increasing power of computers and numerical methods makes it possible to simulate more accurately the propagation of seismic waves in heterogenous media. In this work, a staggered-grid finite-difference solution of the elastic wave equation is employed for the wave propagation simulation. With numerical experiments, we show that the time-reversal imaging will enable us to explore the spatio-temporal history of complex earthquake.
-
Since early 1990's, several Quaternary faults have been found in the southeastern part of the Korean peninsula with reference to fault activity. Because some of these faults could be considered a capable fault, it is a very delicate matter, which need to be deal with carefully in assessing the seismic hazard. In determining whether or not a faults are capable, because of the low rate of seismicity and insufficient relationship between instrumental macro-seismicity and fault, there has been considerable debate among geologists and geophysicists in Korea. In this study, we discuss the criteria and probabilistic approaches that are used to assess whether or not a fault is seismogenic. And, we preliminarily also suggest the probability of fault activity from the spatial association between faults and earthquake epicenters, fault slip and tectonic stress, and geological evidence for multiple episodes of reactivation.
-
We have been conducting several studies on providing information to the public promptly as soon as earthquake occurs. Recently, JMA proposed a method for warning big earthquakes by observing the first 2 seconds after the first arrival. In this study, the envelope of the absolute value of the first 2 seconds after the first arrival is calculated, and then the relation of epicentral distance and slope of envelope, parameter B, is obtained. This result is applied to local magnitude equation of KMA, which then gives us a new magnitude equation from which can estimate the magnitude using maximum amplitude of P wave. We applied the method to two recent earthquakes; Uljin and Daegu. The results using only the vertical components show that the magnitudes are lower than those calculated by the local magnitude equation of KMA. However, when we apply the method to the 3 components of maximum displacements, the results corresponds with those obtained from the local magnitude equation.
-
The purpose of the present study is to analyse characteristics of the background noise for the broadband seismic stations in KMA. It is well known that the background noise arises continuously from long period microseism, sea waves, minute changes of atmospheric pressure, seasonal temperature change of the ground surface, culture activities, and etc. The background noise shows spatial and temporal changes and it has various characteristics such as its spectral amplitudes in frequency domain are not constant Such the background noise gives considerable influences on the quality of seismic record. To investigate annual variations, the background noise was separated into high frequency components of above 1Hz More larger average amplitude is found in winter than other seasons. The average amplitude for 12 seismic stations are compared. It is known that the background noise is considerably larger in stations located in island region such as Jeju, Ulleungdo, and Bagryeongdo seismic stations. However the noise is relatively small in inland stations such as Chuncheon, Chungju and Uljin seismic stations.
-
Facilities of 76skV Substation(S/S) play an important role in electric power supply grids. Various power facilities of 765kV S/S might be damaged enormously if a strong earthquake occurs. In an effort to mitigate possible earthquake disasters, KEPRI (Korea Electric Power Research Institute) set forth plans to verify seismic safety of the facilities of 765kV S/S. To accomplish the task, an earthquake monitoring systems is constructed at four 765kV S/S sites(Shin-AnSung, Shin-TaeBaek, Shin-SeoSan and Shin-GaPyung). Data from these earthquake monitoring stations are being transmitted via satellite communication. Currently, KEPRI is operating an earthquake monitoring system in freefield of Shin-SeoSan S/S (NSS) tentatively, Also, the data from NSS is preliminarily analyzed using the horizontal to vertical (H/V) spectrum ratio method. The method of H/V spectrum ratio has been used to infer site amplification without previous knowledge of near surface geology. The results of data analysis shorts good S/N ratio and amplification of 20-25 Hz by site effect. In the near future, the accumulated data is expected to provide a basis for assessing and predicting any damages to integrity of 765kV S/S facilities by earthquakes.
-
At starting point, 1D velocity models were inverted by using 430 events with P-wave 5147, S-wave 3729 from KIGAM, KMA, KEPRI, and KINS's seismic networks. A minimum 1D model shows that P-wave velocities are around
$6.0{\pm}0.5\;km/s$ slowly increasing with depth between surface and 15 km. The velocities are about$6.4{\pm}0.2\;km/s$ below 15km to 35km. The earthquake data number for 3D tomography was 630 adding to previous 430 events with limitation of more than 6 station detection and relocation stability of location. The checkerboard test shows that only upper curst part from surface to 17 km have reliable resolution. The results of upper crust part present that the boundary of Gyeong-sang basin and Youngnam massif is mach well velocity variation pattern. The western part of the basin is shown as lower velocity and south-eastern part as higher. This is because that sedimentary rocks are widely located around western part of the basin and volcanic origin rocks are distributed around south-eastern part. -
Stress drops of Brune's single-corner
${\omega}^2$ source model were estimated for the earthquakes (2.0$M3.5{\sim}4.0$ and increase up to $M4.5{\sim}5.0$ above which the level of the stress drop could be assumed to be flat or decrease according to whether the rupture process accompanies buried fault or surface rupturing. The converted data of corner frequency and seismic moment were nicely fitted to the relation of$M_0{\propto}f^3$ but show systematically higher corner frequencies for$M_0>10^15$ Nm. This relationship enables systematic evaluation of a scaling relation between magnitude and stress drop. The inverted level of the stress drop is comparable to the recent studies conducted domestic and abroad. A result of lower stress drop estimated by Jun(1991) is supposed to be due to the use of low frequency spectra and existence of two-comer source model around the Korean Peninsula. -
The Ulsan Fault System continues from north of Gyeongju to Ulsan city, trending NNW-SSE and is about 50 km. Many Quaternary faults have been reported and investigated with outcrop observation. Lineaments have been extracted with aerial photograph interpretation and classified by their ranks. Trench excavations on the lineaments along Ulsan Fault System have been carried out to clarify the neotectonic movements and fault parameters such as the latest movement age, fault displacement, slip rate and recurrence interval. We have compiled data from previous studies on criteria of segment type such as lineament rank, seismicity, slip rate, and the latest fault movement. Based on these data, we tried to devide the Ulsan Fault System into several segments. The results of segmentation with each types of segment along the Ulsan Fault System did not show singular division point but overlapped or different length and location.
-
Recently, many researches on the dissipation of excess pore pressure in liquefied sand grounds have been performed to evaluate post-liquefaction behaviors of structures. In this paper. centrifuge tests were performed to simulate liquefaction behaviors of prototype soil. The evaluation model of solidified layer thickness was developed to simulate non-linear variation of solidified layer thickness with time. Also, the dissipation of excess pore pressure in liquefied sand was evaluated by applying the solidification theory and the consolidation theory. The developed model gives a good estimation of the solidified layer thickness and the time history of excess pore pressure.
-
The centrifuge and 1-g shaking table tests were performed simultaneously to compare the dynamic behaviors of loose sands of same geotechnical properties. The prototype soils were 10 m thick liquefiable loose sands. The geometric scaling factors were 20 for 1-g and 40 for centrifuge tests. The excess pore pressure, surface settlement, and acceleration in the soil were measured at the same locations in the 1-g and centrifuge tests. The total excess pore pressure from development to dissipation was measured. In the centrifuge test, viscous fluid was used as the pore water to eliminate the time scaling difference between dynamic time and dissipation time. In the 1-g tests, the steady state concept was applied to determine the unit weight of the model soil, and two different time scaling factors were applied for the dynamic time and the dissipationtime. It is concluded that the 1-g tests can simulate the excess pore pressure of the prototype soil if the permeability of the model soil is small enough to prevent dissipation of excess pore pressure during shaking and the dissipation time scaling factor is properly determined.
-
Liquefaction-induced lateral spreading has been the most extensive damage to pile foundations during earthquakes. However, a case of pile failure was reported despite the fact that a large margin of safety factor was employed in their design. This means that the current seismic design method of pile is not agreeable with the actual failure mechanism of pile. Newly proposed failure mechanism of pile is a pile failure based on buckling instability. In this study, failure behavior of pile embedded in liquefied soil deposits was analyzed considering lateral spreading and buckling instability performing 1g shaking table test. As a result, it can be concluded that the pile subjected to excessive axial loads (
$near\;P_{cr}$ ) can fail by buckling instability during liquefaction. When lateral spreading took place in sloping grounds, lateral spreading increased lateral deflection of pile and reduced the buckling load, promoting more rapid collapse. In addition, buckling shape of pile was observed. In the ease of pile buckling, hinge formed at the middle of the pile, not at the bottom. And in sloping grounds, location of hinge got loiter compared with level ground because of the effects of lateral spreading. -
Despite the site classification method was improved in the previous study, the response spectrum would be required to be modified by adjusting the integration interval to calculate the site coefficients because the response spectra did not match well the average spectral accelerations obtained by site response analyses in the range of long periods. In this paper, new response spectra for each site categories were determined by adjusting the integration interval of long-period site coefficient
$F_{v}$ from$0.4{\sim}2.0$ to$0.4{\sim}1.5$ second. It matched well the average spectral accelerations and new response spectrum, and it was also improved compared to the current site classification system. -
Estimation of Site Response Characteristics at Town Fortress Areas Damaged by Historical EarthquakesTo estimate the local site effects at two town fortress areas where stone parapets were collapsed during historical earthquakes, site characteristics were evaluated using borehole drillings and seismic tests and equivalent-linear site response analyses were conducted based on the shear wave velocity (Vs) profiles determined from site investigations. The study sites are categorized as site classes C and B according to the mean Vs to 30 m ranging from 500 to 850 m/s, and their site periods are distributed in short period range of 0.06 to 0.16 sec. For site class C in the study areas, the short-period (0.1-0.5 sec) and mid-period (0.4-2.0 sec) site coefficients,
$F_{\alpha}$ and$F_\nu$ specified in the Korean seismic design guide, underestimate the ground motion in short-period band and overestimate the ground motion in mid-period band, respectively, due to the characteristics showing high amplification in short period range, which can result in the collapse of stone parapets having the short natural period. -
This paper addresses a fundamental research subject to complement and improve current domestic design specifications for the strong motion duration criterion and the envelop function of artificial accelerograms that can be applied to the earthquake-proof design of nuclear structures. The criteria for design response spectra and strong motion duration suggested by WRC RG 1.60 and ASCE Standard 4-98 are commonly being used in the profession, and they are first compared with each other and reviewed. By applying 152 real strong earthquake records that are over magnitude of 5 in the rock sites to the strong motion duration criterion in ASCE 4-98, an empirical regression model that predicts the strong motion duration as a function of earthquake magnitude is then developed. Using synthetically generated earthquake time histories for the five cases whose strong motion durations vary from 6 to 15 seconds, a seismic analysis is conducted to identify effects of the strong motion durations on the seismic responses of nuclear structures.
-
This study describes a generation of artificial earthquake wane compatible with seismic design spectrum. In seismic response analysis of building structures, the input ground accelerations have considerable effect on dynamic characteristics of structures. Therefore, it is important to properly select input ground motions for seismic response analysis. In this paper, the artificial earthquake wave are generated according to previously recorded earthquake waves in past earthquake events. The artificial wave have identical phase angles to the recorded earthquake wane, and their overall response spectra are compatible with seismic design spectrum with 5% of critical viscous damping. Each simulated earthquake wave has a identical phase angles to the original recorded ground acceleration, and match to design response spectra in the range of period from 0.02 to 10.0 seconds. It is concluded that the artificial earthquake waves simulated in this paper ate applicable as input ground motions for a seismic response analysis of building structures.
-
Recently, as RC flat plate system is applied on high-rising building largely, necessity of all over research about lateral performance becomes a prominent. In this paper, It is estimated that performance of slab-column connection in flat plate system is inter-story drift index 3.6%. In addition, when R-factor is fixed in seismic design, it must be considered all system. Also Considering that plastic hinge propagation is not adjustable, R-factor should be applied bellow '5.5'.
-
Every structure has the expected life span of its own and it has to be rebuilt. New buildings were preferred and put value a quantitative spread of apartment houses because of the rapid growth of national economy. Therefore, the apartment houses were not taken into consideration about maintenances. Carbon fiber sheet is widely used to strengthen old structural members but it is very rarely applied to a construction field for apartment houses. The purpose of this study is to develop effective strengthening methods for reinforced concrete columns using carbon fiber sheets. Eight reinforced concrete column specimens confined by carbon fiber sheet of uniaxial direction were tested using 10,000kN universal testing machine (UTM).
-
This paper summarizes full-scale test results on CFT column-to-flat plate connections subjected to gravity loading. CFT construction has gained wide acceptance in a relatively short time in domestic building construction practice due to its various structural and construction advantages. However, efficient details for CFT column to flat plate connections have not been proposed yet. Based on the strategies that maximize economical field construction, several connecting schemes were proposed and tested. Test results showed that the proposed connections can exhibit punching shear strength and connection stiffness exceeding those of R/C flat plate counterparts. A semi-analytical procedure is presented to model the behavior of CFT column-to-flat plate connections. The five parameters to model elastic to post-punching catenary action range are calibrated based on the limited test data of this study. The application of the proposed modeling procedure to progressive collapse prevention design is also illustrated.
-
Numerical Study of PZ Strength Effects on Cyclic Seismic Performance of RBS Steel Moment ConnectionsEffects of panel zone (PZ) strength on cyclic seismic performance of the RBS connections was studied based on the validated finite element analysis. High-profile cyclic correlation of finite element model with the full-scale test results based on the material and geometric nonlinear post-buckling analysis was among the most significant consideration in this study. Numerical response results as affected by the panel zone strength reproduced the experimentally observed results quite reasonably. The finite element modeling capability of this study can be used to supplement or to replace in part the costly full-scale connection testing.
-
In this paper 35- and 72-story tube system and trussed tube system were designed and their seismic performances were evaluated by nonlinear static analysis. According to the analysis results, the tube system structures retained high stiffness and strength; however they showed brittle failure mode due to the yielding of columns. In the case of trussed tube system, columns in the side-side buckled first followed by the buckling of the braces. When buckling-restrained braces were applied, plastic hinges formed in the lower stories gradually spreads to the higher stories, resulting in ductile behavior.
-
This study lotuses on the seismic behavior of 3-, 9-, and 20-story steel moment resisting frame (MRF) structures designed in accordance with the 2000 International Building Code using different Response Modification factors (R factors) 8, 9, 10, 11, and 12. For a detailed case study, 30 different structures were evaluated for twenty ground motions representing the hazard level which is equal to a 2% probability exceeding in 50 years (2% in 50 years). The results showed that the current R factors provide conservative designs for the 3- and 9-story buildings for the Collapse Prevention performance objective. However, the 20-story buildings designed without using the minimum requirement of spectral acceleration CS prescribed in the IBC 2000 did not satisfy the seismic performance for Collapse Prevention performance.
-
For evaluation of building performance, a nonlinear dynamic capacity of the building is a key parameter. In this study, an reinforced concrete special moment resisting frame building was chosen to study the process of determining the nonlinear dynamic capacity. The building, which was designed by IBC 2003 representing new codes, was composed of special moment resisting frames in the perimeter and internal frames inside the building. The capacity, which is inter-story drift capacity, consists of two categories, local and global collapses. Global collapse capacity was determined by incremental dynamic analysis. Local collapse capacity was determined by the same method except for utilizing damage index. In audition to this, it was also investigated that the effect of including internal frames designed by gravity load in the analysis. Results showed that the damage index is a useful tool for determining local collapse. Furthermore, including the internal frames with special frames in the analysis is very important in determining the capacity of a building so both must be considered at the same time.
-
This thesis investigates the behavior of precast wall systems with a new vertical connection which are proportioned by the displacement based design. The proposed precast wall systems are supposed to provide additional spaces and seismic strengthening in remodeling existing residential buildings. For a fast remodeling constructions using PC wails require an efficient, economic fabrication method. A C-type vertical connections for PC wall systems is proposed for transfer of bending moment between walls in the vertical direction while a shear key in the center of wall is prepared to transfer shear forces by bearing. The proposed vertical connection allows us easy fabrication because of different direction of slots at the edges of wall. The dimension of C-type connection components are determined by engineering models and a series of test.
-
Three building structures haying piloti frames in the lower two stories were selected as prototypes and were analyzed using nonlinear static analysis to investigate the seismic capacity of these buildings. The first one has a symmetrical moment resisting frame (Model 1), the second has an infilled shear wall in the central frame (Model 2), and the third has an infilled shear wall only in one of exterior frames (Model 3), The analytical results were compared with those of shaking table tests with regards to the overstrength and ductility of the irregular buildings. Infilled shear wall in Model 2 and Model 3 induced large overstrength factors, 6.8 and 6.0, respectively, which are about two times larger than that of Model 1, 3.5. The displacement ductility ratio in Model 2 was only 2.5, due to the shear failure of wall in the piloti stories, whereas those of Model 1 and Model 3 reached 3.2.
-
An experimental investigation on the behavior of reinforced concrete coupling beams is presented. The test variables are the span-to-depth ratio, the ratio of flexural reinforcement and the ratio of shear rebar. The distribution of arch action and truss action which compose the mechanism of shear resistance is discussed. This study proposes the deformation model for reinforced concrete coupling beams considering the bond slip of flexural reinforcement. The yielding of flexural reinforcements determines yielding states and the ultimate states of reinforced concrete coupling beam are defined as the ultimate compressive strain of struts and the degradation of compressive strength due to principal tensile strain of struts. It is expected that this model can be applied to displacement-based design methods.
-
By Testing tension coupon, deviation of yield strength & tensile strength of SS and SM is big but the that of SN is small relatively. So Designing weak beam type frame by using SN could be reflected well the original intention. As the strength ratios of beam and column becomes large, the absorption energy is large. The increase quantity was linear relationship, the y=0.46x+0.62
$(R^2=0.82)$ -
In this paper, deformation capacity of steel moment connections with RHS column was investigated. Initially, non-linear finite element analysis of five bate steel beam models was conducted. The models were designed to have different detail at their beam-to-column connection, so that the flexural moment capacity was different respectively. Analysis results showed 4hat the moment transfer efficiency of the analytical model with RHS-column was poor when comparing to model with WF(Wide flnage)-column due to out-of-plane deformation of the RHS-column flange. The presence of scallop and thin plate of RHS column was also a reason of the decrease of moment transfer efficiency, which would result in a potential fracture of tile steel beam-to-column connections. Further test on beam-to-column connections with RHS column revealed that the moment transfer efficiency of a beam web decreased due to the out-of-plane deformation of column flange, which led to premature failure of the connection.
-
This study represents results of fragility curve development for 3-span continuous bridge. To research the response of bridge under earthquake excitation, Monte Carlo simulation is performed to study nonlinear dynamic analysis. Because of limited number of real time histories from the Korean peninsula, a set of 150 synthetic time histories were generated. Fragility corves in this study are represented by lognormal distribution functions with two parameters and developed as a function of PGA. Five damage states were defined to express the condition of damage based on the actual experimental damage data of bridge column. As a result of this research, the value of damage probability corresponding to each damage state were determined. This approach may be used in constructing the fragility curves for all of bridge structure and, by extension, in constructing the seismic hazard map.
-
In the design of bridge piers in seismic area, the ductility requirement is one of the most important design criteria. In order to enhance the seismic performance of RC columns, it is necessary to make the ductility of columns larger by covering RC columns with steel tubes or confining RC columns by arranging transverse reinforcement such as hoop ties closely. Concrete encased composite columns can be utilized for bridge piers especially in seismic area. In this paper, finite element analyses are performed to study the nonlinear behavior of concrete encased composite columns with single core steel or multiple steel elements under static and quasi-static loads. The cross-sections of these specimens ate composed of concrete-encased H-shaped structural steel columns and a concrete-encased circular tube with partial in-filled concrete. Test parameters were the amount of the transverse reinforcement, encased steel member, and loading axis. Through the comparison between FE analyses and test results, adequate material models for confined concrete and unconfined concrete ate investigated. After getting the proper analysis models for composite columns, several parameters are considered to suggest design considerations on the details of composite piers.
-
Korea is considered to be immune from the earthquake hazard because it is located far away from the active fault. However, recent earthquake caused a loss of lives and economical loss worldwide. Hence there has been raised an importance of the earthquake resistant design for various infrastructures. In this research, the seismic design and evaluation criterion for RC bridge pier were proposed from the experimental results of 82 circular RC bridge piers tested in domestic and aboard. New seismic criterion was introduced the limited ductile design provision suitable to Korean peninsula, which would be classified as a low or moderate seismic region. In addition, further important topic for the seismic safety of RC bridge piers in Korea is the seismic performance enhancement of RC bridge piers, which were designed and constructed before the 1992 seismic design provision. Therefore, the proposed seismic performance evaluation criterion could be very useful to judge seismic retrofit need or not according to the residual seismic performance of the RC bridge piers. Also, it could reduce an uncertainty for the safety of the infrastructure under earthquakes.
-
This paper presents a seismic response analysis of bridge structures considering foundation-soil interaction and multi-support input motion. In the earthquake analysis of structures it is usually assumed that the input ground motion is the same at all supports. However, this assumption is not justified for long structures like bridges, because observations have shown the earthquake ground motion can vary considerably within relatively small distances. When the soil under the foundation is relatively soft and deep, analysis for foundation-soil interaction always must be peformed. To consider foundation-soil interaction, soil response analysis is preceded, and after determining the material characteristics of foundation element obtained by foundation-soil interaction analysis at the frequency domain, the seismic response analysis of bridge superstructure with the equivalent spring and damper is performed. Finally, influences of multi-support input motion, which are affected by different soil characteristics, are also considered in this paper.
-
The purpose of this study is to investigate the inelastic behavior of precast segmental prestressed concrete bridge columns. A computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. An unbonded tendon element based on the finite element method, that can represent the interaction between tendon and concrete of prestressed concrete member, is used. A joint element is newly developed to predict the inelastic behaviors of segmental joints. The proposed numerical method for the inelastic behavior of precast segmental prestressed concrete bridge columns is verified by comparison with reliable experimental results.
-
Integral pile shaft-column foundations are increasingly popular thanks to not only the comparative advantage of economy in constructing large cast-in-drilled-hole(CIDH) piles compared with driven piles with pile cap footings but also being free from problems associated with the critical column-footing connection. In this paper, the structural characteristics of integral pile shaft-column foundations as well as seismic analysis methodology and reinforcement details for seismic design are introduced.
-
Most of seismic designs of major structures up to now have been performed by the traditional 'force-based design' approaches. However, they are not so efficient to evaluate the structural deformations by potential nonlinear behaviors which are directly related with the damages or performance levels during earthquakes. Lately, based on this situation, various kinds of new seismic design approaches based on the deformation, which is called 'displacement-based design' procedures, have been proposed. In this paper, most of detail techniques and procedures of the new design methods in the literature are comparatively reviewed and evaluated first, followed by a series of design examples of typical bridge structures. Comparing the results with those of the existing force-based design, the improved levels of performance and economy of the displacement-based seismic design have been validated.
-
The main objective of this study was to derive a formula of ductility reduction factor, expressed as
$R{\mu}$ . To attain this objective, a study comprised reduction factors computed for stiffness degrading systems undergoing different levels of ductility and to investigate an accuracy of the formula. Based on this study, the main conclusions can be summarized :(1) The ductility reduction factor is primarily affected by the period of the system and the displacement ductility ratio. (2) The proposed formula is simpler and the inelastic deformations of bridge structures are better than those by the others formulas we used before. -
Site coefficients in IBC and KBC codes have some limits to predict the rational seismic responses of a structure, because they consider only the effect of the soil amplification without the effects of the structure-soil interaction. In this study, upper and lower limits of site coefficients are estimated through the pseudo 3-D elastic seismic response analyses of structures built on linear or nonlinear soil layers considering the structure-soil interaction effects. Soil characteristics of site classes of A, B, and C were assumed to be linear, and those of site classes of D and E were done to be nonlinear and the Ramberg-Osgood model was used to evaluate shear modulus and damping ratio of a soil layer depending on the shear wave velocity of a soil layer. Seismic analyses were performed with 12 weak or moderate earthquake records, scaled the peak acceleration to 0.1g or 0.2g and deconvoluted as earthquake records at the bedrock 30m beneath the outcrop. With the study results of the elastic seismic response analyses of structures, new standard response spectrum and upper and lower limits of the site coefficients of Fa and Fv at the short period range and the period of 1 second are suggested Including the structure-soil interaction effects.
-
This paper is concerned with the simplified criterion given in ASCE 4-98, for determining whether soil-structure interaction (SSI) analysis is required for seismic response analysis of nuclear power plant structures. In this study, the criterion is evaluated for a couple of example structures including an existing nuclear power plant and the Hualien large-scale seismic test building. Forced vibration analysis and seismic response analysis are carried out using the simple stick model with soil springs and an elaborated SSI analytical model. From the numerical analyses, it is found that the criterion may not allow the fixed-base analysis for bedrock with shear wave velocity of greater than 1,100m/s which is a well-known criterion for a rock site. In addition, it is indicated that peak amplification as well as the peak broadening specified in NRC RG 1.122. shall be considered to include the effects of SSI.
-
If a structure is founded on the ground saturated with pore water, then the ground should be modeled as a saturated two-phase porous medium for accurate earthquake response analysis. In this study, a 3-dimensional transmitting boundary is developed for modeling of far field using u-U formulation for water-saturated transversely isotropic layered stratum. The developed transmitting boundary is verified by comparing the dynamic stiffness of rigid square foundation on water-saturated isotropic layered stratum with the case of using equivalent single-phase medium model.
-
In this study, quantitative sensitivity analysis on rockfill material influencing the dam crest displacement of Concrete-Faced Rockfill Dam(CFRD) subjected to earthquake loading was carried out. The purpose of this study is to indicate the most important input parameter and to show the quantitative variation of displacement at the crest of CFR type dam during earthquake loading with this input parameter. From the sensitivity analysis, it was found that the crest displacement of CFR type dam subjected to dynamic loading was absolutely affected by the shear modulus of rockfill material and the effect of friction angle of it was negligible. This relative difference of sensitivity was more outstanding in case of crest settlement than in case of crest horizontal displacement. Also, it was found that the extent of effect of shear modulus on the displacement at the crest of CFRD due to dynamic loading decreased as maximum amplitude of input acceleration increased.
-
In this study, fragility curves of continuous buried pipelines subjected to transverse PGD (permanent ground deformation) due to liquefaction are proposed. For the waterworks system, continuos buried pipelines made of ductile iron, poly ethylene, and poly vinyl chloride are analyzed and fragility curves are drawn. Fragility curves are based on the repetitive analyses results and formulated with the dominant factors of behaviour of buried pipeline. With the use of fragility curves, engineers can estimate the status of damage of buried pipeline without overall knowledge of relevant features. Especially, fragility curves proposed in this study will act as a major module of earthquake loss estimation method. Moreover, critical value of magnitude and width of transverse PGD (by which the full damage status of buried pipelines are induced) are estimated. With the use of regression curves of these values, pre evaluation of seismic safety of buried pipelines located within liquefaction hazardous region will be possible.
-
In order to reduce the secondary earthquake disaster resulting from the damage of gas facilities it is indispensable to establish an early response system on the basis of damage prediction. In this study the procedure of damage prediction for gas facilities is proposed and applied to the gas supply model area. Model area is divided into several little blocks. The soil condition and the characteristics of facilities were investigated at each block. Using fragility curves of facilities the damage level was analyzed under various seismicities. It is confirmed that the exposure gas pipe line in several blocks is damaged seriously by the collapse of building structures.
-
This study presents a new information model for building a database which is used for the Damage Calculation in a Road network after Seismic outbreak (DCRS). The component which is required for information system and data analysis is divided by four factors. Those are Ground Motion Component, Road Network Component, Fragile Structure Component, and Cost Component. These components have various manners and procedures that build informations by each systems. In this study, applying the domestic system resources and these four factors, we presented the integrated evaluating system. finally, we also present the prototype of DCRS based on the ArcGIS. It is expected that developed prototype can play a role in more improved DCRS by advanced study.
-
구조 재료와 시공기술의 발달로 구조물은 높고 길게 설계할 수 있게 되었으나, 그에 따른 진동 문제와 사용성에 관한 문제가 발생하였고 구조물의 과다한 변위는 구조물에 심각한 손상을 발생 시켰다. 이러한 구조물의 진동 문제를 해결하기 위하여 본 논문에서는 확률신경망이론을 사용한 구조물의 능동제어방법을 제안하였다. 구조물의 제어를 위하여 LQR 제어알고리즘을 이용하여 구조물의 상태벡터와 제어력을 구한 후, 상태벡터를 입력으로 제어력을 출력으로 하는 확률신경망의 훈련패턴을 구성하였다. 제안된 방법을 사용하여 지진하중을 받는 3층 빌딩구조물을 제어하였고, 기존의 인공신경망의 제어 결과와 비교하였다.
-
One of the most promising semi-active devices proposed for structural control is magnetorheological fluid (MR) dampers. While many researches are making too much of application to structural control, few of papers are considering how to design the MR dampers having good performance. In this paper, the sub-optimal design procedure for MR dampers is presented. This paper shows that an MR damper having the capacity of about 5,000 N is designed according to proposed procedure, as an exmple.
-
An optimum design method for hybrid control systems is proposed in this study. By considering both active and passive control systems as a combined or a hybrid system, the optimization of the hybrid system can be achieved simultaneously. In the proposed approach, we consider design parameters of active control devices and the elements of the feedback gain matrix as design variables for the active control system. Required quantity of the added dampers are also treated as design variables for the passive control system. In the proposed method, the cost of both active and passive control devices, the required control efforts and dynamic responses of a target structure are selected as objective functions to be minimized. To effectively address the multi-objective optimization problem, we adopt a preference-based optimization model and apply a genetic algorithm as a numerical searching technique. As an example to verify the validity of the proposed optimization technique, a wind-excited 20-storey building with hybrid control systems is used and the results are presented.
-
The seismic characteristics with 3-Dimensional Floor Isolation System have been studied using a shaking table system. In this study, we made two kind of floor system (Type I, Type II) and several seismic tests with and without isolation system were conducted to evaluate 3-Dimensional Floor Isolation Effectiveness. Both type have showed large reduction effectiveness in acceleration, response spectra but Type II have showed lower acceleration and lower first mode in response spectra, compared to type I. On the basis of test results and consideration of application, it is found that type II is more suitable for floor model of main control room of Nuclear Power Plant.
-
The seismic characteristics with 3-Dimensional isolation systems have been studied using a shaking table system. In this study, we made nuclear power plant main control room floor systems and several seismic shaking table tests with and without isolation systems were conducted to evaluate floor isolation effectiveness. Isolation systems have showed large reduction effectiveness in acceleration and response spectra with x and z direction respectively, but horizontal isolation is more effective than vertical one It is required to make isolation systems of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such isolation systems, it is recommended that much consideration should be taken into account when applied to main control room of NPP.
-
Many types of tuned mass dampers (TMDs), such as active TMDs, multiple TMDs, hybrid TMDs etc., have been studied to effectively reduce the dynamic responses of a structure subjected to various types of dynamic loads. In this study, we replace a passive damper by a semi-active tuned mass damper to improve the control performance of conventional TMDs (STMD). An idealized variable damping device is used as semi-active dampers. These semi-active dampers can change the properties of TMDs in real time based on the dynamic responses of a structure. The control performance of STMD is investigated with respect to various types of excitation by numerical simulation. Groundhook control algorithm is used to appropriately modulate the damping force of semi-active dampers. The control effectiveness between STMD and a conventional passive TMD, both under harmonic and random excitations, is evaluated and compared for a single-degree-of-freedom (SDOF) structure. Excitations are applied to the structure as a dynamic force and ground motion, respectively. The numerical studies showed that the control effectiveness of STMD is significantly superior to that of the passive TMD, regardless of the type of excitations.
-
Long span, high-rise bridges are rapidly increasing nowadays. Because of high flexibility, such bridges are easily excited by winds, vehicles, and pedestrians. The vibration of bridge induces a vibration of lamp post and pillar. Wind loads can also excite lamp posts and traffic signal structures directly. Because of low damping, such vibrations of lamp post are frequently amplified and come to collapse or lamp failure. In addition, such vibration makes the maintenance cycle shorter and increases social cost. We conducted vibration tests and identified the dynamic characteristics of two types lamp posts, and proposed tuned mass dampers to control the vibrations. Established models of the lamp posts present the dynamic characteristics of the structures very well and they are used to design TMDs. In this study, we suggested a new-type TMD model that is small, simple, economic and effective to suppress the vibration of lamp posts. The efficiency of TMD was examined by numerically and is to be examined experimentally.
-
In this paper an analytical study is carried out to improve the capacity of absorbing boundary using dashpot, one of the most widely used absorbing boundaries in FEM. Using harmonic plane wave equation, absorbing boundary condition is modified to maximize its capacity according to the incident angle. Validity of the modified absorbing boundary conditions is investigated by adopting the solution of Miller-Pursey which is the solution for the wave propagation in semi-infinite elastic media, and the absorption ratio is calculated according to various Poisson's ratios.
-
A new Energy-Dissipating Sacrificial Device(EDSD) is proposed, which can effectively dissipate the energy stored in the structures during seismic actions. A mathematical 3-D bridge models and analysis techniques are developed to represent the non-linear behavior of the EDSD, various seismic responses of a sample bridge with the EDSD are analyzed in terms of energy, member forces and deformation using the developed analysis method. And the EDSD is tested and certified it's behavior and stability to apply on exiting bridges. The EDSD can be able to dissipate a large amount of energy and therefore it can prevent the pier's excessive forces under seismic excitations and EDSD and its connected members are also stable. Additionally, the method and guidelines of an optimum EDSD design are proposed in terms of installation method and decision of number of EDSD. The Proposed EDSD under seismic excitations can significantly decrease the excessive storing energy in the bridge structures and reduce the relative displacements of each superstructure to the ground. The EDSD is also found to function as a structural fuse under strong ground motions, sacrificing itself to absorb the excessive energy. Consequently, economical enhancement of the seismic performance of bridges can be achieved by employing the newly developed energy dissipation sacrificial device(EDSD).
-
Stay cables, such as used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Recently some studies have shown that active and semiactive control system using MR damper can potentially achieve both higher performance levels than passive control system and adaptability with few of the detractions. However, a control system including a power supply, controller, and sensors is required to maximize the performance of the MR damper and this complicated control system is not effective to most of large civil structures. This paper proposes a smart complex damping system which consists of toggle system and MR dampers by introducing electromagnetic induction(EMI) system as an external power source to MR damper. The performance of the proposed damping device has been compared with that of the passive-type control systems employing a MR damper, a linear viscous damper, and EMI system.
-
이 논문에서는 신경망 제어기와 MR 댐퍼를 이용하여 지진하중을 받는 지진격리 벤치마크 구조물의 응답 감소를 위한 반능동 제어방법이 제안되었다. 제안방법 중 신경망 제어기에는 적절한 제어력을 산출하기 위해 가격함수를 기반으로한 학습 알고리즘과 간편한 민감도 계산기법이 도입되었다. MR 댐퍼가 계산되어진 제어력과 비슷한 제어력을 낼 수 있도록 clipped 알고리즘을 이용하였고, 제안된 반능동 신경망 제어방법이 지진격리 장치가 설치된 벤치마크 구조물에 적용되었다. 수치해석에서는 벤치마크 문제를 정의한 논문에서 제공된 수동제어방법이나 예시제어방법과 제안 방법의 제어성능을 비교하였다. 수치해석 결과 제안방법은 지하 변위를 약간 증가시키지만, 각층의 가속도, base shear, building corner drift 등을 매우 효과적으로 줄이는 것으로 판명되었다.
-
This paper presents the results of experimental studies of the mechanical characteristics of the Coil Spring and Viscous Damper system. The Coil Spring and Viscous Damper systems were selected for the isolation of Emergency Diesel Generator (EDG) which is located in Nuclear Power Plant (NPP). The Coil Spring and Viscous Damper systems were developed for, the operating vibration isolation and seismic isolation for scaled Model EDG System. The damping properties of the viscous damper changes as the variation of velocity. As a results, nonlinear damping characteristics of viscous damper system were evaluated.
-
This paper presents tile results of experimental studies of the isolated Model EDG Systems. For the experimental work, the scaled model of EDG system and the isolation systems were developed. The target EDG model is 16PC2-5V400 which was manufactured by the SEMT Pielstick corporation. The Coil Spring and Viscous Damper Systems were selected for the isolation system. The Coil Spring and Viscous Damper systems can reduce not only seismic forces but also the operating vibration. For the input seismic motions, the scenario earthquake and the artificial earthquakes which were developed as NRC design spectrum and Uniform hazard Spectrum(UHS) were selected. As a result, at least 20% of seismic forces were decreased as the isolation system.
-
The ultimate capacities of a rubber bearing are defined by compressive stress, shear strain, and stabilized roster ing force. The experiments were conducted with parameters of shesr elasticity(G) and first shape factor(S1), second shape factor(S2) for rubber bearing. Considering with test results, the ultimate capacities were verified, and furthermore the influence of those parameters were clarified. Using test results stable deformation of rubber bearings for designing was proposed.
-
Seismic performance of semi-active fuzzy control algorithm to operate MR dampers for coupling adjacent building is investigated in this paper. In the proposed semi-active control technique, the fuzzy logic is used as a method to adjust input voltage to MR damper. In order to validate control performance of proposed technique, the seismic performance of the semi-active fuzzy control system is compared with that of passive control system where the input voltage to MR damper is set to display maximum damping force. The simulated results show that the semi-active fuzzy control technique effectively regulates the trade-off existing between seismic responses of two buildings subject to various earthquake excitations.
-
Seismic control performance of MR dampers, which have severe nonlinearity, differs with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with an MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with an MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. Frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed.
-
In this study, seismic response mitigation effect of an MR damper generating response-dependent frictional force is investigated. It has been reported in previous studies that passively operated MR damper with constant input current doesn't show better control performance than semi-active MR damper with varying input current calculated by control algorithms such as linear quadratic regulator and sliding mode control. However, in order to operate the MR damper semi-actively, other control systems besides the damper itself such as sensors for measuring structural responses and controller for calculating optimal input current are necessary, which deteriorate the economical efficiency. This study presents a MR damper generating frictional force of which magnitude is controlled in accordance to the displacement and velocity transferred to the damper. Numerical analyses results indicate that the performance of the response dependent MR damper is closely related with the range of the friction force and it can be designed to short better control performance than the passive MR damper.
-
This paper compares the seismic response control performance of linear and non-linear models fer tuned liquid damper (TLD). The existing linear and nonlinear TLD models were used for the numerical analysis of single degree of freedom (SDOF) and multi degree of freedom (MDOF) systems with TLD. The nonlinear model considers the variation of the frequency and damping of the TLD with varying excitation amplitude while the linear one has the invariant parameters. Numerical analysis results from SDOF systems indicate that the nonlinear model shows about 5% better control performance than linear one when the mass ratio is 2% and the optimal parameters for reducing peak responses are dependent on the characteristics of the excitation earthquake loads.
-
Lee, Sung-Kyung;Lee, Sang-Hyun;Min, Kyung-Won;Park, Eun-Churn;Woo, Sung-Sik;Chung, Lan;Youn, Kyung-Jo 527
A real-time hybrid method, in which the experimental implementation and the numerical computation of a structure are simultaneously carried out in real-time and combined on-line, has been used as a dynamic testing technique of structure to investigate its dynamic behaviors. In this paper, an experimental hybrid method, which implements the earthquake response control of a building structure with a TLD by using only a TLD as an experimental part, is proposed and is experimentally verified through a shaking table test. In the proposed methodology, the whole building structure with a TLD is divided into the upper TLD and the lower structural parts as experimental and numerical substructures, respectively. At the moment, the control force acting between their interface is measured from the experimental TLD with shear-type load-cell which is mounted on shaking table. Shaking table vibrates the upper experimental TLD with the response calculated from the numerical substructure, which is subjected to the excitations of the measured interface control force at its top story and an earthquake input at its base. The experimental results show that the conventional method, in which both a TLD and a building model are physically manufactured and are tested, can be replaced by the proposed methodology with a simple experimental installation and a good accuracy for evaluating the control performance of a TLD. -
In this study, performance level evaluation tests have been actually performed on laminated rubber seismic isolation bearings (LRB) made in Korea. To provide basic data for setting up fabrication criteria and performance evaluation criteria three real scale LRB were tested and the test results were analysised. Accordingly, a large capacity test device has been designed and manufactured to implement the tests. The device selected for evaluation is a circular LRB actually applied in bridges. Evaluation tests were conducted using full-scale LRB with diameter of 851mm in the rubber part and total height of 215mm of which the effective horizontal stiffness and equivalent damping ratio have been measured during the experiments.
-
Small-scale models have been frequently used for seismic performance tests because of limited testing facilities and economic reasons. However, there are not also enough studies on similitude law for analogizing prototype structures accurately with small-scale models, although conventional similitude law based on geometry similitude is not well consistent in their inelastic seismic behaviors. When fabricating prototype and small-scale model of reinforced concrete structures by using the same material, added mass is demanded from a volumetric change and scale factor could be limited due to aggregate size. Therefore, it is desirable to use different materials for small-scale model. In our recent study, a modified similitude law was derived depending on geometric scale factor, equivalent modulus ratio and ultimate strain ratio. And quasi-static and pseudo-dynamic tests on the specimens are carried out using constant and variable modulus ratios, and correlation between prototype and small-scale model is investigated based on their test results. In this study, tests on scaled model of different concrete compressive strength aye carried out. In shaking table tests, added mass can not be varied. Thus, constant added mass on expected maximum displacement was applied and the validity was verified in shaking table tests. And shaking table tests on non-artificial mass model is carried out to settle a limitation of acceleration and the validity was verified in shanking table tests.
-
본 논문에서는 한국과 일본에 위치한 여러 연구기관들 사이에서 수행된 온라인 네트워크 유사동적 실험 곁과에 대해 나타내었다. 예제 구조물로는 4경간 연속의 면진 교량을 이용하였다. 실험 장비를 보유하고 있는 두 연구기관에서 면진 장치의 비선형 거동에 대한 실험을 수행하고 각 실험 결과를 조합하여 전체 구조의 동적 해석을 수행하였다. 본 논문에서는 먼저 인터넷을 이용한 두 가지 데이터 전송기법을 이용하여 두 기법의 효율성을 비교, 분석하였다. 또한 최근 국내에 위치한 두 연구기관 사이에서 수행된 실험 결과에 대해 논의하였다. 본 연구에서는 상대 연구기관의 실험 상황 및 수행된 실험 결과의 효율적인 모니터링을 위하여 웹 기반의 자바 모니터링 시스템을 개발하였다. 마지막으로 유선과 무선 인터넷을 이용한 온라인 실험 기법에 대하여 나타내었다. 그 결과, 온라인 네트워크 실험에 소요된 실험 시간은 데이터 전송 기법과 실험장비에 따라 매 시간 단계의 데이터 전송에 0.2-l5초, 각 연구기관의 유사동적 실험에 1-10초의 시간이 소요되어 매우 큰 폭으로 변화함을 알 수 있었다. 또한 무선 인터넷을 이용한 온라인 실험의 경우, 뛰어난 이동성과 인터넷 보안성 등과 같은 여러 가지 장점을 가지고 있음을 알 수 있었다.
-
Distributed control architecture is based on sharing control and data between multiple nodes on a network Communication and task sharing can be distributed between multiple control computers. Although many communication protocols exist, such as TCP/IP and UDP, they do not have the determinism that realtime control demands. Fiber-optic reflective shared memory creates the opportunity for realtime distributed control. This architecture allows control and computational tasks to be divided between multiple systems and operate in a deterministic realtime environment. One such shared memory architecture is based on Curtiss-Wright ScramNET family of fiber-optic reflective memory. MTS has built seismic and structural control software and hardware capable of utilizing ScramNET shared memory, opening up infinite possibilities in research and new capabilities in Hybrid and Model-In-The-Loop control.
-
Research using multiple shake tables present new and unique challenges in controls. Typical single shake table tests with large specimens must cope with significant specimen force feedback that can increase tracking error due to specimen gain, damping, and non-linearity. Multiple shaking tables with distributed specimens can produce cross-coupling forces due to inertial and response effects and forces due to static differential displacements. Although many various control architectures exist, basic simplified techniques can yield excellent results without risk to control stability. Off-line simulation techniques can also prove invaluable for studying system response before the real system is operated.
-
The paper introduces the grid technology currently applied intensively to civil engineering around the world. Basic concepts of grid technology and its application areas are summarized. Some of available grid systems in foreign countries and also in Korea are introduced and their main goals and functions aye compared. Through reviewing the KOCED program currently under development in Korea, the future of the grid technology in civil engineering is groped.
-
Torsional behavior of eccentric structures under seismic loading may cause stress and/or strain concentration, which result in the failure of the structures in an unexpected manner. This study propose how to assess the seismic capacity of plan-irregular RC wall structures. The seismic capacities ate expressed in terms of lateral displacement capacity of each wall. The seismic demands for displacement are assessed by so called displacement-based design approach. Those seismic capacity and demands are combined D-R coordinate, which is made up of lateral displacement and rotation angle. To expand these concepts to the inelastic region the adaptive modal analysis method is used. In addition, the failure mechanisms including torsional failure are defined on D-R coordinate. Finally, seismic assessments of two 3-story plan-irregular wall structures ate presented.
-
The seismic safety of the prestressed concrete containment building was evaluated by the seismic fragility analysis based on the nonlinear dynamic time-history analyses. Four kinds of earthquake ground motions were used for the seismic fragility analysis of the containment building to consider the potential earthquake hazard. The conventional seismic fragility analysis of the safety related structures in nuclear pouter plant have been performed by using the linear elastic analysis results for the seismic design. In this study, the displacement based seismic fragility analysis method was proposed.
-
765kV substation facilities are most important as electric power supply network in the 21 century. So, in order to prevent interruption of electric power supply under earthquake, 765kV substation facilities have to secure the safety against the earthquake. However, even though each substation facility is interconnected mutually, seismic interaction effect doesn't be considered in the initial design. Therefore, seismic capacity evaluation of 765kV substation facilities is carried out considering the seismic interaction effect on a basis of seismic design criteria for Korean transmission and substation facilities.
-
This paper introduces a new structural health monitoring using a nano sensor. The sensor is made of nano smart composite material based on carbon nanotubes. The nano sensor is fabricated as a thin and narrow polymer film sensor that is bonded or deposited onto a structure. The electrochemical impedance and dynamic strain response of the neuron change due to deterioration of the structure where the sensor is located. A network of the long nano sensorcan form a structural neural system to provide large area coverage and an assurance of the operational health of a structure without the need for actuators and complex wave propagation analyses that are used with other methods.
-
강재기둥으로부터 전달되어 내려오는 모멘트 하중에 의한 베이스판의 변형을 고려한 앵커볼트의 설계방법에 대해 소개하였다. 기둥-베이스판 접합부의 설계를 위해 간략해석 모델 (Simple Beam Model) 이 개발되었으며 인장력과 모멘트 하중에 동시에 저항하는 앵커볼트의 설계를 위해 국부 메카니즘 개념이 도입되었다. 제안된 새로운 설계법을 적용하여 앵커볼트와 베이스판 사이의 최대지압력을 계산할 수 있었으며 이를 바탕으로 앵커볼트의 사이즈를 결정할 수 있었다. 본 논문에서는 상기 간략히 소개된 앵커볼트 설계법을 보다 상세히 기술하였다.
-
This paper presents 3D infinite elements in Cartesian coordinates for the elastodynamic problem in multi-layered half-space. Five kinds of infinite elements are developed by using approximate expressions of multiple wave components for the wave function in exterior far-field soil region. They are horizontal, horizontal-corner, vertical, vertical-corner and vertical-horizontal-corner elements. The elements can be used for the multi-wave propagating problem. Numerical example analyses are presented for rigid disk, square footings and embedded footing on homogeneous and layered half-space. The numerical results obtained show the effectiveness of the proposed infinite elements.
-
Acceleration time history used in the seismic analysis of nuclear porter plant structure should envelop a target power spectral density (PSD) function in addition to design response spectrum. Current regulation guide defines the target PSD function only for the U.S. URC RG 1.60 Design Response Spectrum. This paper proposes a technical scheme to obtain the target PSD function compatible with generally defined design response spectrum. The scheme includes the methodology for design-spectrum compatible motion history in order to minimize the variation of the derived target PSD function. The PSD calculation procedure follows simple and practical methods allowed within regulation. Effectiveness of the proposed scheme is identified through an example problem. The design response spectrum In the example is based on U.S. NRC RG 1.60 but amplifies the spectral acceleration amplitudes above 9Hz. The target PSD function with little variation can be constructed with the reduced time history ensemble.
-
This paper presents the results of a study to verify the sufficient control performance of semiactive tuned mass damper and to identify suitable control methods for semiactive tuned mass damper in structural vibration control. In this study, four control algorithms are considered: on-off displacement based groundhook, on-off velocity based groundhook, clipped optimal and maximum energy dissipation algorithm. For semiactive tuned mass damper, MR damper is considered as a controllable damping device and the command voltage is calculated by the control algorithms. Each of the control theory is applied to the three story shear building excited by three earthquakes. The performance of each algorithm is compared with that of conventional tuned mass damper system using evaluation criteria. The simulation results indicate that semiactive tuned mass damper has control efficiency. Among the control algorithms, on-off displacement based control theory shows the best efficacy and robustness.