• 제목/요약/키워드: vernier

검색결과 114건 처리시간 0.027초

의치상 레진의 중합 방법에 따른 크기의 안정성 및 표면 형태에 관한 연구 (DIMENSIONAL STABILITY AND SURFACE MORPHOLOGY OF VARIOUS DENTURE RESINS)

  • 채숙영;방몽숙
    • 대한치과보철학회지
    • /
    • 제30권3호
    • /
    • pp.401-410
    • /
    • 1992
  • The purpose of this study was to investigate the dimensional changes and surface morphology of dentures processed by various polymerization conditions. The measurements were done by taking radiograph and using vernier calipers and each specimen was observed on scanning electron microscope. Results obtained were as follows. 1. The difference of dimensional stability was not recognized between various polymerization conditions(heat-cured resin, pour-type resin, microwave-cured resin, and injection molding resin). 2. There were expansion and shrinkage in the occlusal dimension, shrinkage in the frontal dimension, and expansion in the lateral dimension. 3. Scanning electron microscope pictures of heat-cured resin showed dense and regular surface morphology. 4. Microwave-cured resin surface appeared more regular and smooth than pour-type resin but less dense and more irregular than heat-cured resin. 5. Scanning electron microscope pictures of pour-type resin with the lowest dimensional change showed the most irregular surface morphology.

  • PDF

Real -Time ECG Signal Acquisition and Processing Using LabVIEW

  • Sharma, Akshay Kumar;Kim, Kyung Ki
    • 센서학회지
    • /
    • 제29권3호
    • /
    • pp.162-171
    • /
    • 2020
  • The incidences of cardiovascular diseases are rapidly increasing worldwide. The electrocardiogram (ECG) is a test to detect and monitor heart issues via electric signals in the heart. Presently, detecting heart disease in real time is not only possible but also easy using the myDAQ data acquisition device and LabVIEW. Hence, this paper proposes a system that can acquire ECG signals in real time, as well as detect heart abnormalities, and through light-emitting diodes (LEDs) it can simultaneously reveal whether a particular waveform is in range or otherwise. The main hardware components used in the system are the myDAQ device, Vernier adapter, and ECG sensor, which are connected to ECG monitoring electrodes for data acquisition from the human body, while further processing is accomplished using the LabVIEW software. In the Results section, the proposed system is compared with some other studies based on the features detected. This system is tested on 10 randomly selected people, and the results are presented in the Simulation Results section.

세 가지 방식의 스캐너 종류에 따른 모형 정확도 평가 (Evaluation of the Model Accuracy according to Three Types of Dental Scanner)

  • 이재준;박진영;배소연;전진훈;김지환;김웅철
    • 치위생과학회지
    • /
    • 제15권2호
    • /
    • pp.226-231
    • /
    • 2015
  • 본 연구는 세 가지 종류 스캐너에 따른 정확도를 비교 평가하기 위하여 시행되었다. 경석고 모형과 스캐너로 채득한 디지털 모형에 각 4지점씩 계측지점을 선정하였고, 이들 4지점사이를 DVC와 디지털 모형 측정 프로그램을 이용하여 길이를 측정하고, 다음과 같은 결론을 도출하였다. 세 가지 종류의 스캐너 가운데 레이저 스캐너가 백색광 스캐너나 청색광 스캐너보다 높은 정확도를 나타내었으나 이 세 가지 종류의 스캐너 모두가 임상적으로 사용하는 것이 가능하다.

평판형 스캐너를 이용한 목재 수축률 측정 (Wood Shrinkage Measurement of Using a Flatbed Scanner)

  • 박용건;장윤성;양상윤;여환명;이미림;엄창득;권오경
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권1호
    • /
    • pp.43-51
    • /
    • 2015
  • 목재 이용의 측면에서 중요한 인자 중 하나인 수축률에 관한 다양한 연구가 수행되고 있다. 버니어 캘리퍼스를 이용하여 치수를 측정할 때, 목재 시편에 작용하는 외력에 의해 왜곡된 치수가 측정될 수 있고, 시편의 양이 많으면 치수측정에 많은 시간이 소요된다. 스캐너를 이용하여 획득한 이미지로 치수를 측정하고, 수축률을 계산하면 외력이 작용하지 않아 치수 측정의 오류를 줄일 수 있고, 한 번의 스캔으로 여러 시편의 이미지를 획득하여 시간을 단축시킬 수 있다는 장점이 있다. 스캔 이미지 상에서 목재 시편과 배경 사이의 경계면을 뚜렷하게 구분할 수 있도록 threshold 방법을 적용하여 치수 측정을 용이하게 하였다. 이미지를 이용하여 측정된 목재 시편의 치수는 버니어 캘리퍼스를 이용하여 측정한 값보다 다소 크게 측정되었으며, 버니어 캘리퍼스보다 높은 정밀도로 수축률을 계산하기 위한 스캔 이미지의 최대 픽셀 길이는 0.053 mm/pixel인 것을 확인하였다.

DDR SDRAM을 위한 저전압 1.8V 광대역 50∼500MHz Delay Locked Loop의 설계 (Design of Low Voltage 1.8V, Wide Range 50∼500MHz Delay Locked Loop for DDR SDRAM)

  • 구인재;정강민
    • 정보처리학회논문지A
    • /
    • 제10A권3호
    • /
    • pp.247-254
    • /
    • 2003
  • 본 연구에서 고속 데이터 전송을 위해 Double Data Rate(DDR) 방식을 사용하는 SDRAM에 내장할 수 있는 저전압 광대역 Delay Locked Loop(DLL) 회로를 설계하였다. 고해상도와 빠른 Lock-on 시간을 위하여 새로운 유형의 위상검출기론 설계하였고 카운터 및 Indicator 등 내장회로의 빠른 동작을 위해 Dual-Data Dual-Clock 플립플롭(DCDD FF)에 기반을 둔 설계를 수행하였으며 이 FF을 사용하므로서 소자수를 70% 정도 감소시킬 수 있었다. Delay Line 중에서 Coarse 부분은 0.2ns 이하까지 검출 가능하며 위상오차를 더욱 감소시키고 빠른 Lock-on 기간을 얻기 위해 Fine 부분에 3-step Vernier Line을 설계하였다. 이 방식을 사용한 본 DLL의 위상오차는 매우 적고 25ps 정도이다. 본 DLL의 Locking 범위는 50∼500MHz로 넓으며 5 클럭 이내의 빠른 Locking을 얻을 수 있다. 0.25um CMOS 공정에서 1.8V 공급전압 사용시 소비전류는 500MHZ 주파수에서 32mA이다. 본 DLL은 고주파 통신 시스템의 동기화와 같은 다른 응용면에도 이용할 수 있다.

치과용 스캐너 전용 석고를 이용하여 제작된 3차원 디지털 모형의 정확도 평가 (An evaluation of validity of three dimensional digital model fabricated by dental scannable stone)

  • 김기백;김수진;김재홍;김지환
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.29-35
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by dental scannable stone. Methods: Twenty same cases of stone models(maxillary full arch) were manufactured. Intercanine distance, intermolar distance, two dental arch lengths(right, left), two diagonal of dental arch lengths(right, left) were measured for comparison. Each of ten stone models were measured by digital vernier calipers and scanned by dental scanner. Ten digital models were measured by CAD program. The mean(SDs) values were compared by a Mann-Whitney U test(${\alpha}$=0.05). Results: No statistically significant differences between the two groups were found at intermolar distance, dental arch length(right)(p>0.05). However, intercanine distance, dental arch length(left) and two diagonal of dental arch lengths(right, left) were statistically significant(p<0.05). Conclusion: Stone models fabricated by dental scannable stone showed larger than digital models.

골 절삭용 초음파 수술기의 실험적 평가에 관한 연구 (A Study about Experimental Evaluation of an Ultrasonic Surgery Unit for Bone-cutting)

  • 사민우;심해리;고태조;이종민;김종영
    • 한국기계가공학회지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2016
  • In the dentistry field, an ultrasonic surgery unit is widely used in bone cutting and scaling to reduce operation time and minimize hemorrhage. The purpose of this study was to evaluate bone cutting and the effect of a specimen's temperature on the two-type ultrasonic surgery unit using a handpiece moving system(HMS). A HMS, which can cut the bone, was developed to perform the experimental procedure with precision of motion control. Bone specimens were prepared from a combination of epoxy-hardener and cortical bone of bovine leg. Through the bone-cutting experiment, the cutting depth was evaluated by not only scanning electron microscopy, but also Vernier calipers. Also, the temperature distribution was measured by a thermo-graphic camera. This study may be applied methodically in various experimental evaluations on a performance test by a HMS.

무릎뼈 높이에 대한 도수측정방법의 신뢰도와 타당도 (Reliability and Validity of the Manual Measurement Method for Patellar Height)

  • 김문환;윤성준;원종혁
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.54-61
    • /
    • 2013
  • This study was to determine the reliability and validity of manual measurements of patellar height to standard radiographic measurements in 30 knees of 15 subjects. Patellar height was measured using manual and radiographic methods. The manual measurements were performed by two examiners using digital vernier calipers with the subject sitting and the knees in $30^{\circ}$ of flexion. The radiographic measurements were performed in the same position. The reliability of the manual measurements was assessed by means of intraclass correlation coefficients [ICC(3,1)], and the validity was investigated using the Pearson's product-moment correlation coefficient and an independent t-test. The intra- and inter-rater reliabilities of the manual measurement of patellar height were excellent (ICC=.86 and .88 respectively). The validity of patellar height measured manually compared to the radiographic method was good (Pearson's r=.69). In conclusion, the manual method is an objective, qualitative measurement of patella height.

Enhanced Approach Using Computational and Experimental Method for the Analysis of Loudspeaker System

  • Park Seok-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제24권3E호
    • /
    • pp.90-98
    • /
    • 2005
  • Enhanced approach using computational and experimental method is proposed and performed to describe very well the behavior of loudspeaker than conventional method. Proposed procedure is composed of four parts. First, Thiele-Small parameters for test loudspeaker are identified by an electrical impedance method like as a delta mass method. Second part includes the processes to measure physical properties. Physical data like masses and thicknesses of loudspeaker's components are measured by an electrical precision scale and a digital vernier caliper. Third, the identified Thiele-Small parameters are proposed to be used as load boundary conditions for vibration analysis instead of electromagnetic circuit analysis to get a driving force upon bobbin part. Also, these parameters and physical data are used to modify physical properties required for computation to accommodate simulated sound pressure level with measured one for loudspeaker enclosure system. These data like as Young's modulus and thickness for a diaphragm are required for vibration analysis of loudspeaker but not measured accurately. Finally, it was investigated that simulated sound pressure level with full acoustic modeling including an acoustic port for test loudspeaker agreed with experimental result very well in the midrange frequency band(from 100 Hz to 2,000 Hz). In addition, several design parametric study is performed to grasp acoustical behaviors of loudspeaker system due to variations of diaphragm thicknesses and shapes of dust cap.

수종 근관 충전재의 항균 효과에 관한 연구 (ANTIMICROBIAL EFFECT OF ROOT CANAL CEMENTS ON MICROORGANISMS FROM INFECTED ROOT CANALS)

  • 고영훈;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.190-199
    • /
    • 1991
  • The purpose of this study was to evaluate the antimicrobial effect of root canal cements such as AH-26, Sealapex, Canals and Apatite root sealers(Type I, II, III) and to determine the efficacy of their activities. S.mutans(AHT), S.sanguis(NCTC 9811) and B.gingivalis(381) were streaked on blood agar and the PVC tybes filled with root canal cements were applied on. Then the microorganisms were cultured for 48 hours, anaerobically. B.cereus(KCTC 1012) was streaked on nutrient agar, PVC tubes were applied on and were cultured for 48 hours, aerobically. The inhibition zones of root canal cements were measured with vernier caliper. The data statistically analyzed, and the results were as followed. 1. Apatite root sealers(Type I, II, III) showed no inhibition zones. 2. AH-26, Sealapex and Canals had inhibition zones with varying degrees. The inhibition zone of AH-26 was greatest and followed by Canals and Sealapex(P<0.01). 3. As time goes by after mixing the root canal cements, AH-26, Canals and Sealapex showed significantly reducing inhibition zones(P<0.01). 4. There were the least inhibition zones of all the root canal cements on S.mutans and followed in such order as; B.gingivalis, S.sanguis and B.cereus(P<0.01).

  • PDF