DOI QR코드

DOI QR Code

An evaluation of validity of three dimensional digital model fabricated by dental scannable stone

치과용 스캐너 전용 석고를 이용하여 제작된 3차원 디지털 모형의 정확도 평가

  • Kim, Ki-Baek (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Kim, Su-Jin (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Kim, Jae-Hong (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Kim, Ji-Hwan (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University)
  • 김기백 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김수진 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김재홍 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김지환 (고려대학교 대학원 보건과학과 치의기공전공)
  • Received : 2012.11.26
  • Accepted : 2013.03.12
  • Published : 2013.03.30

Abstract

Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by dental scannable stone. Methods: Twenty same cases of stone models(maxillary full arch) were manufactured. Intercanine distance, intermolar distance, two dental arch lengths(right, left), two diagonal of dental arch lengths(right, left) were measured for comparison. Each of ten stone models were measured by digital vernier calipers and scanned by dental scanner. Ten digital models were measured by CAD program. The mean(SDs) values were compared by a Mann-Whitney U test(${\alpha}$=0.05). Results: No statistically significant differences between the two groups were found at intermolar distance, dental arch length(right)(p>0.05). However, intercanine distance, dental arch length(left) and two diagonal of dental arch lengths(right, left) were statistically significant(p<0.05). Conclusion: Stone models fabricated by dental scannable stone showed larger than digital models.

Keywords

References

  1. Anusavice KJ. Phillips' science of dental materials. 11th ed. Philadelphia: W.B. Saunders, 621-654, 2003.
  2. Creed B, Chung HK, Jeryl DE, James JX, Robert P. Lee. A comparison of the accuracy of linear measurements obtained from cone beam computerized tomography images and digital models. Semin Orthod. 17, 49-56, 2011. https://doi.org/10.1053/j.sodo.2010.08.010
  3. Jae-Hong Kim, Ki-Baek Kim, Hae-Young Kim, Jung-Ae Kim, Woong-Chul Kim, Ji-Hwan Kim. Reliability, accuracy of evaluations obtained from CEREC AC system digital impression: an in-vitro study. The Journal of Korean Academy of Dental Technology. 34(2), 121-128, 2012. https://doi.org/10.14347/kadt.2012.34.2.121
  4. Kobayashi Y, Lee G, Hotta Y, Fujiwara N, Miyazaki T. The effect of proximal teeth on the digitizing accuracy of the shoulder margin of the crown abutment by a laser digitizer equipped in an experimentally developed CAD/CAM device. J Showa Univ Dent Soc. 20, 158-164, 2000.
  5. Luthardt RG, Kuhmstedt P, Walter MH. A new method for the computer-aided evaluation of three-dimensional changes in gypsum materials. Dent Mater, 19, 19-24, 2003. https://doi.org/10.1016/S0109-5641(02)00013-1
  6. Mormann WH, Brandestini M. In: State of the art of CADS/CAM restorations: 20 years of CEREC (M ormann WH) London. Quintessence, 1-8, 2006.
  7. Persson M, Andersson M, Bergman B. The accuracy of a high-precision digitizer for CAD/CAM crowns. J Prosthet Dent. 74, 223-229, 1995. https://doi.org/10.1016/S0022-3913(05)80127-1
  8. Sang-Ik Bak. The comparison between manual and 3D-digital measurement in dental cast measurements according to the degree of crowding. Korea University Graduate School of Clinical Dentistry, Department of Orthodontics, Master's degree, 2006.
  9. Witkowski S. (CAD-)/CAM in dental technology, Quintessence Dent Technol, 28, 169-184, 2005.

Cited by

  1. Evaluation of validity of three dimensional dental digital model made from blue LED dental scanner vol.15, pp.5, 2014, https://doi.org/10.5762/KAIS.2014.15.5.3007
  2. 구강 내 스캐닝 방법에 의해 제작된 폴리우레탄 모형의 정확도 평가 vol.36, pp.2, 2014, https://doi.org/10.14347/kadt.2014.36.2.91
  3. 구강 내 스캐너와 구강 외 스캐너를 사용하여 취득된 스캔 데이터 정확도 비교 vol.37, pp.4, 2013, https://doi.org/10.14347/kadt.2015.37.4.191
  4. 첨가법에 의해 제작된 단관의 내면 적합도 분석 vol.37, pp.4, 2013, https://doi.org/10.14347/kadt.2015.37.4.229
  5. 치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향 vol.57, pp.3, 2019, https://doi.org/10.4047/jkap.2019.57.3.203
  6. 일부 한국인 하악 제2소구치 교두 변이 양상에 대한 3차원적 분석 vol.42, pp.3, 2013, https://doi.org/10.14347/jtd.2020.42.3.220