• 제목/요약/키워드: train voltage

검색결과 231건 처리시간 0.026초

전기철도 교/직 절연구분장치의 절연열화 현상 (Insulation Deterioration of AC/DC Section Insulators for Electric Railroad Catenary.)

  • 최규형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권1호
    • /
    • pp.16-22
    • /
    • 2003
  • While passing through the AC/DC section insulators installed at electric railroad catenary, some electric trains undergo mis-operation of main circuit breaker after AC/DC change-over operation. This paper provides insulation resistance measurements of AC/DC section insulators, which confirm the insulation levels of section insulators are below the standard of insulators. The insulation deterioration and pantograph arrangement on the electric train can produce voltage impression on section insulator which induces mis-operation of main circuit breaker To mitigate the insulation deterioration of the section insulator installed at underground railroads, the section insulators have been cleaned periodically, but section insulator structure should be modified to make the section insulator performance perfect. Based on the above analysis, effective modification method of AC/DC section insulator is provided.

전기 철도의 전력선 통신을 위한 전차선과 조가선의 통신 특성 분석 (Analysis of Communication Characteristics on Contact wire and Messenger wire of Electric Railroad for Power Line Communication)

  • 이희준;안승호;강승욱;이종구
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.157-162
    • /
    • 2010
  • Power line communication, using 25[kV] high voltage of railway catenary, is to provide information which is real-time safety information for train operations and train workers in driving. Lots of noise were occupied in the contact wire by electrical and communication equipments. A signal attenuation was caused characteristics of the contact wire and messenger wire. For relaying communications to transmit information using the contact wire, catenary the noise and signal attenuation were investigated. And the final goal of the study was realized to transmit video information by power line communication on electric railway.

틸팅열차 운행 중 고조파 측정 및 분석에 관한 연구 (A Study of Harmonic Measurement and Analysis during Tilting Train express Operation)

  • 강철;임재찬;허재선;김재철;이수길;한성호;이은규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.297-300
    • /
    • 2009
  • Recently, TTX(Tilting Train eXpress), EMU (Electric Multiple Unit) has operated test. Presently, electric problems(harmonic, voltage variation etc) of TTX are studying briskly. Henceforth, electrical harmonic study of TTX will operate on the rail actually is needed. In this paper, we detected electrical harmonic of operating TTX. In addition to we analyzed and estimated electrical harmonic regarding TTX's coasting, acceleration and braking state.

  • PDF

철도 차량 제어 보드용 모듈형 DC-DC 컨버터 개발 (Development of modular DC-DC converter for application of train control board)

  • 임원석;김종현;류명효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1398-1400
    • /
    • 2005
  • In this paper, a modular dc-to-dc converter, in order to apply to the control board of train vehicles, is presented. Forward converter with active-clamp reset circuit and synchronous rectifier(SR) is employed to achieve high efficiency. To reduce the size and height of the converter, low profile magnetic components are used. The design and performance of the modular dc-to-dc converter with experiments on a 50W(5V/10A) prototype for the 60V$\sim$140V input voltage range are presented.

  • PDF

Inhibition of voltage-dependent K+ current in rabbit coronary arterial smooth muscle cells by the class Ic antiarrhythmic drug propafenone

  • An, Jin Ryeol;Li, Hongliang;Seo, Mi Seon;Park, Won Sun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제22권5호
    • /
    • pp.597-605
    • /
    • 2018
  • In this study, we demonstrated the inhibitory effect of the Class Ic antiarrhythmic agent propafenone on voltage-dependent $K^+$ (Kv) channels using freshly isolated coronary artery smooth muscle cells from rabbits. The Kv current amplitude was progressively inhibited by propafenone in a dose-dependent manner, with an apparent $IC_{50}$ value of $5.04{\pm}1.05{\mu}M$ and a Hill coefficient of $0.78{\pm}0.06$. The application of propafenone had no significant effect on the steady-state activation and inactivation curves, indicating that propafenone did not affect the voltage-sensitivity of Kv channels. The application of train pulses at frequencies of 1 or 2 Hz progressively increased the propafenone-induced inhibition of the Kv current. Furthermore, the inactivation recovery time constant was increased after the application of propafenone, suggesting that the inhibitory action of propafenone on Kv current is partially use-dependent. Pretreatment with Kv1.5, Kv2.1 or Kv7 inhibitor did not change the inhibitory effect of propafenone on the Kv current. Together, these results suggest that propafenone inhibits the vascular Kv channels in a dose- and use-dependent manner, regardless of $Na^+$ channel inhibition.

회생 차량의 전압 상승 한도를 고려한 AT 급전시스템 정태해석 (Static Analysis of AT Feeding Systems considering the Limited Rise of Regenerative Voltage)

  • 김백;문영현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1322-1327
    • /
    • 2004
  • There are some previous studies that utilize constant impedance models or constant current models for electric trains to perform the static analysis of AT feeding systems. These mentioned models have some merits of linear systems but yield erroneous results because of the innate restraints of the models since linear models cannot represent the features of constant power in inverter-driven trains. From these reasons, it is suitable that the train be considered as a constant load model when it drives or as a constant source model when it applies regenerative brake. However, excessive rise of regenerative voltage during the braking may damage the vehicle itself and the feeding systems so the voltage must be restricted below a certain value. Keeping these facts in minds, we suggest new methods of analyzing AT feeding systems using the constant power models with the conditions of voltage constraints. The simulation results from a sample system using the proposed method illustrate both the states of system variables and the supply-demand relation of power among the trains and the systems very clearly, so it is believed that the proposed method yields more accurate results than conventional methods do.

  • PDF

도시철도차량의 운행 선로환경 및 공간적 분포에 따른 공급전압 동특성 변화 (A Study on Variation of the Dynamic Characteristic of Supply Voltage According to the Track Environment and Spatial Distribution as Driving of Urban Transits)

  • 김양수;장진영;이기식;구경완;김재문
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1380-1386
    • /
    • 2012
  • It is important to consider supply voltage stability in case of design and construction of a substation at electric railway because a urban transit is operated by electricity and it is driven simultaneous in the same section. This paper study on variation of the dynamic characteristic of supply voltage according to the track environment and spatial distribution as driving of urban transits. Simulation tool, TOM(Train Operations Model) software is used to ensure stability of feeder system being used around the world. As results of simulation, voltage of the contact wire is in limits on driving operation diagram of urban transits. Also, it has confirmed that there is a correlation the phase current, depending on the speed of urban transit and track environment like vertical gradients and curve radius.

안테나 임피던스를 이용한 공진형 FSK 송신기 (A Resonant FSK Transmitter Using Antenna Impedance)

  • 황선도;조규민;인치각
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1134-1136
    • /
    • 2002
  • This paper proposes a FSK(Frequency Shift Keying) transmitter which has a inverter for power amplification instead of linear amplifier. As it can generate large signal using resonant circuit under the low voltage source even if the impedance of antenna is large as like a loop antenna of TWC(Train to Way-side Communication) system. In this paper, the proposed fully digital controlled transmitter including FSK modulation is presented and its control schemes are discussed.

  • PDF

철도차량용 PWM 컨버터방식 비교 (The Comparison of PWM Converter's Topology in Electric Train)

  • 이현원;김남해
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.97-100
    • /
    • 1999
  • AC to DC single phase PWM converter for traction application requires rated high power and voltage. Therefor, series or parallel operation converters are necessary with considering the limitation of the power device specification. This paper compares the characteristic between two parallel operation of conventional PWM converter and Single phase three level converter about comparison of power circuit, cooling system control method and harmonic current by computer simulation.

  • PDF

고속 철도(TGV-Korea) 조명용 DC-DC 컨버터의 개발 (A Development of DC-DC Converter for the Reading Lamp of TGV-Korea)

  • 김성일;김희준;김희일
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.635-638
    • /
    • 1999
  • Manufacturing TGV-Korea, international standards and TGV-standards should be strictly applied in order to insure the normal operation and the safety of passengers in a train service. This paper presents a development of 800W DC-DC converter for the reading lamp of TGV-korea. The converter is designed for satisfying the regulations of international standards and TGV-standards regarding the burning-in test, the vibration test, the electro-magnetic emissions test, etc. As an experimental result, the maximum efficiency is obtained as 92.3[%] at normal input voltage and output power.

  • PDF