• Title/Summary/Keyword: toxicity gases

Search Result 59, Processing Time 0.02 seconds

Application of Membranes for Biological Waste Gas Treatment Processes (생물학적 폐가스 처리공정 내 멤브레인 활용)

  • Lee, Sang-hun
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.327-332
    • /
    • 2021
  • The use of membranes for MBRWG (Membrane Bioreactor for Waste Gas) treatment can provide highly selective separation of a waste gas stream followed by effective biological removal. MBRWG have several potential advantages, among which the most distinctive one is separation of gas and liquid phases at each side of membrane potentially allowing the optimal biomass control toward effective biodegradation of target gases as well as biofilm activation. This advantage becomes especially favorable for removal of hydrophobic toxic gases, such as xylene, by MBRWG systems, because the mass transfer, the toxicity, and thereby the biodegradation of hydrophobic gas treatment requires sensitive handling of liquid stream and water control near biofilm. Among various membranes for MBRWG treatment, PDMS-hollow fiber membranes provide the high gas mass transfer. Despite lower specific surface areas, capillary type membranes are also applied current MBRWG studies. In addition to the main application of membranes as biofilm supporter in MBRWG systems, there can be another application of membranes in a posterior process for removal of residual gases or dusts emitted from conventional biological waste gas treatment processes.

A Study on the Flame Resistance and Combustion Characteristics of MDF Plywood (MDF합판의 방염 및 연소특성에 관한 연구)

  • Kim, In-Beom
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.256-260
    • /
    • 2014
  • Interior of the building is used as a MDF plywood if there is a fire in order to delay the ignition, flame retardant paint, flame retardant solution and flame retardant film are being handled by the flame retardant. Combustion characteristics anf flame retardant performance results can be summarized as follows: General film with a sample showed that short of the criteria in terms of carbonation area, and the results of flame retardant paint, flame retardant solution and flame retardant film products satisfied the criteria. Toxic gases generated in the combustion process results in a film samples using a high incidence of carbon monoxide and the creation of a smoke could be seen. This confirm that is estimated that result from incomplete combustion of PVC film that attach, and displays high toxicity index and hazard class relatively.

A Technical Description on The Safety Aspects related To Gas Suppression Fire Protection System (가스계 소화시스템관련 안전기술)

  • 이창욱
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.21-29
    • /
    • 2002
  • With regard to the personnel safety and other safety when the gas suppressants are discharged into the area where occupants exist, the short term and long term effects to the health of people are discussed mainly with the Carbon dioxide agent and Halon Replacement agents system. To gain the benefits of CO2 extinguishing systems while minimizing risk to people serious attention must be given to personnel safety in the design, installation, and maintenance of CO2 systems. Training of personnel is essential. A major factor in the use of a clean agent fire suppressant in a normally occupied area is toxicity. While all halocarbon agents are tested for long-term health hazards, the primary endpoint is acute or short-term exposure, The primary acute toxicity effects of the halocarbon agents described here are anesthesia and cardiac sensitization. For inert gases, the primary physiological concern is reduced oxygen concentration.

  • PDF

Analgesic Effects of Intrapleural Bupivacaine Administration in Cholecystectomy Patients (담낭절제술 환자에서 늑막강내에 투여된 Bupivacaine의 진통효과)

  • Koo, Gill-Hoi
    • The Korean Journal of Pain
    • /
    • v.2 no.2
    • /
    • pp.167-173
    • /
    • 1989
  • Inadequate pain relief after upper abdominal surgery increases the incidence of pulmonary complications due to the difficulty in coughing and deep breathing. Kvalheim and Reiestad (1984) introduced intrapleural administration of local anesthetic solutions to produce analgesia following cholecystectomy performed through a subcostal incision, unilateral breast surgery and renal surgery. We studied continuous intrapleural administration of bupivacaine and epinephrine, and its effect in controlling pain after cholecystectomy. In 9 patients, an intermittent dosage technique was used. An intrapleural catheter was inserted and 20 ml of 0.5% bupivacaine and 1:100,000 epinephrine was administered. Results were as following: 1) Mean analgesic duration from the initial intrapleural injection to secondary administration of supplementary bupivacaine was 13.5 hours. 2) No specific changes were noted on vital signs and arterial blood gases. 3) Effective analgesia, produced by intrapleural bupivacaine resulted in significant improvement in tidal volume as measured by spirometry. 4) No signs of systemic toxicity and complications were encountered. 5) Intrapleural administration of a local anesthetics after cholecystectomy provides a satisfactory duration of analgesia.

  • PDF

A Study on the Fire Safety Performance of Interior Surface Materials in a Building (건축물의 실내건축 재료에 관한 화재안전성 연구)

  • Seo, Su-Eun;Shin, Seung-Woo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.275-290
    • /
    • 2013
  • The main cause of building fire fatalities occur in the combustible material heat, smoke and toxic gases are. Building interior decoration, etc., especially as much of the harmful substances generated during combustion, and, used in domestic architecture wallpaper, ceiling, and other plastics, built-in foam insulation also analyzed recognition of fire hazards approach to test the conkalrorimiteo test, choedaeyeolbangchulryul through, chongbal heat, mass loss rate, generates carbon monoxide gas hazard ratio tests, analysis and evaluation rigid foam index testing the toxicity of hazardous material generated by performing a gas clean up and assess the material test results, the minimum order to provide data to quantify the risk of fire. Ensure fire safety of building materials, composite materials in order to test the various risk factors could be considered organic to the introduction of testing and evaluation is needed urgently.

  • PDF

A Study on Asphyxiation Accidents occurred in the confined space, and their Prevention (밀폐공간 질식재해 발생현황 고찰 및 예방에 관한 연구)

  • Kwon, Bu-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.47-54
    • /
    • 2016
  • A confined space means places where the risk of damage to health caused by lack of oxygen or hazardous gases in inadequate ventilation conditions and the risk of fire and explosion caused by flammable substances. Asphyxiation accidents in a confined space occured every year and also occurred more than two people at the same time. In this study, we surveyed the domestic statistical data occurred the lack of oxygen in confined space for the last 10 years(2006-2015) and, analyzed the accident by industries sector, workplace size etc. 17 fatal work accidents that occurred in confined spaces in Korea between 2013 and 2015 were investigated and analyzed using the database of the KOSHA and suggested interventions to minimize asphyxiation accidents in confined spaces. This paper is expected to be used to establish interventions planning and training as a preventive measures in workplace having confined spaces.

Implementation of Fire Risk Estimation System for various Fire Situations using Multiple Sensors (다중 센서들을 이용한 다양한 화재 상황의 위험도 추정 시스템 개발)

  • Lee, Kwangjae;Lee, Youn-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.394-398
    • /
    • 2016
  • In this paper, a fire detection system based on quantitative risk estimation is presented. Multiple sensors are used to build a comprehensive indicator that represents the risk of fire quantitatively. The proposed fire risk estimation method consists of two stages which determines the occurrence of fire and estimates the toxicity of the surveillance area. In the first stage, fire is reliably detected under diverse fire scenarios. The risk of fire is estimated in the second stage. Applying Purser's Fractional Effective Dose (FED) model which quantitates harmfulness of toxic gases, the risk of the surveillance area and evacuation time are calculated. A fire experiment conducted using four different types of combustion materials for the verification of the system resulted in a maximum error rate of 12.5%. By using FED calculation and risk estimation methods, the proposed system can detect various signs of fire faster than conventional systems.

Environmental Analysis of Waste Cable Recycling Process using a Life Cycle Assessment Method (전과정평가기법을 활용한 폐전선 재자원화 공정의 환경성 평가)

  • Jang, Mi-Sun;Seo, Hyo-Su;Park, Hee-Won;Hwang, Yong-Woo;Kang, Hong-Yoon
    • Resources Recycling
    • /
    • v.31 no.1
    • /
    • pp.37-45
    • /
    • 2022
  • The development of the electrical, electronic, and telecommunication industries has increased the share of electricity in total energy consumption. With the enforcement of the Act on the Promotion of the Development, Use, and Diffusion of New and Renewable Energy in 2021, the mandatory supply ratio of new and renewable energy is expected to expand, and the amount of waste cables generated in the stage of replacing and discarding cables used in the industry is also expected to increase. The purpose of this study was to quantify the environmental burden of waste cable recycling through the life cycle assessment (LCA) method. The results showed that the higher the amount of glue contained in the waste cable, the greater was the amount of fine dust and greenhouse gases generated. In addition, by assigning weights to 10 environmental burden items, it was confirmed that the marine aquatic eco-toxicity potential (MAETP) and human toxicity potential (HTP) had the greatest environmental burden. The main causes were identified as heptane and ethanol, which were the glue contained in the waste cable and the cleaning solutions used to remove them. Therefore, it is necessary to refrain from using glue in the cable production process and reduce the environmental burden by reducing the use of waste cable cleaning solutions used in the recycling process or using alternative materials.

An Experimental Study on the Development of Fire-retardant Treated Wood for Construction (건축용 난연 목재 개발에 대한 실험 연구)

  • Seo, Hyun Jeong;Kim, Nam Kyun;Jo, Jeong Min;Lee, Min Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.149-156
    • /
    • 2017
  • This study investigates fire-retardant performances and combustion/thermal characteristics of fire-retardant treated wood by comparing them with those of fire-retardant untreated wood from the expreimental resutls of cone calorimeter and thermo-gravimetric(TG) analyzer. Hazardousness of combustion product gases for fire-retardant treated wood and untreasted wood were also observed from the results of internal finish material incombustibility test according to the Korea standard code of KS F 2271. In this study, we also tried to improve the fire retardant performance of wood by applying fire-retardant chemical composites, and to secure the fire safety performance in buildings. Red pine (Pinus densiflora) was selected as a test specimen because it is mostly used as a building material in Korea. Fire retardant chemical composites (FRCs) were prepared by mixing boron, phosphorous, and nitrogen species and treated by press-impregnation method. Water-based FRCs were composed of 3% boric acid($H_3BO_3$), 3% borax decahydrate($Na_2B_4O_7$), 8% ammonium carbonate($(NH_4)_2CO_3$), diammonium phosphate ($(NH_4)_2HPO_4$) varied from 10-30% and potassium carbonate($K_2CO_3$) varied from 10-30%. From the test results of cone calorimeter, TG analysis and gas hazard assessments, newly proposed were the optimal composition and production methods of FRCs which can sufficiently meet fire-retardant level 3 based on Korea law of construction. Thus, the FRCs, developed in this study, are anticipated to contribute to the improvement of fire safety and widespread of usage in wood as building materials.

Evaluation of the Burning Properties of Various Carpet Samples by using the Cone Calorimeter and Gas Toxicity Test (콘칼로리미터와 가스유해성 시험법을 이용한 카페트류의 연소특성 평가)

  • Lee, Bong-Woo;Kwon, Seong-Pil;Lee, Jang-Won;Lee, Byoung-Ho;Kim, Hee-Soo;Kim, Hyun-Joong
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.1-9
    • /
    • 2009
  • In this study, the burning behaviours of five different kinds of carpet samples covered with nylon, PP (polypropylene), PTT (poly(trimethylene terephthalate)), wool fabric and NW (nylon and wool) were evaluated by using the cone calorimeter having a radiant flux of 50kW/$m^2$. And the combustion gas toxicity was evaluated according to KS F 2271 test method. As a result of the cone calorimeter test (KS F ISO 5660-1), nylon carpet samples were ignited most easily. In ignition ability or initial flammability, NW carpet samples showed the highest value. In heat release rate (HRR), fire intensity, PP carpet samples were larger than any other samples. Nylon carpet samples were the highest smoke production rate, while N/W carpet samples the lowest. The following were in mass loss rates: NW > wool > nylon > PP > PTT. CO (carbon monoxide) was one of the most toxic gases released from the combustion. PTT carpet samples gave rise to the highest CO concentration, while NW carpet samples the lowest. In addition, PP carpet samples caused the highest $CO_2$ (carbon dioxide) concentration, while NW carpet samples the lowest. Toxicity of the gas produced from carpet samples was determined by the mouse stop motion, and it resulted in the fact that the combustion gas of PTT carpet samples was more toxic than that of any other samples.