References
- Installation Maintenance Fire Protection and Safety Management Act, Article 20, Paragraph 2.
- Park, S. H., "Effective Flame-Proofing Measures for On-site Flame-proofing-treated Items with Businesses," M.D thesis, Dongshin University, Naju(2009).
- Park, H. J. and Kwak, D. I., "A Research on Legal Alternatives to Fire Performance Certificate and Tests for Interior Finish, Decorative Materials in Premises Used as Assemblies," J. of Korean Institute of Fire Sci. & Eng., 15(1), 45-54(2001).
- Cha, J. M., Hyun,. S. H., Kim, I. B. and Yoon, M. O, "A Study on the Flame retardant Performance of MDF Wood According to Flame retardant Treatment Method," J. of Korean Institute of Fire Sci. & Eng., 25(6), 146-155(2011).
- Mok, Y. I., "A Review of the Flame Retardation of Flammable Polymers," Korean Chem. Eng. Res.(HWAHAK KONGHAK), 15(4), 211-224(1977).
- Hilado, C. J., "Flammability Handbook for Plastics," 4th ed., Technomic Publishing Co., Pennsylvania, 1990.
- Dobele, G., Urbanovich, I., Zhurins, A., Kampars, V. and Meier, D., "Application of Analytical Pyrolysis for Wood Fire Protection Control," J. Anal. Appl. Pyrolysis, 79, 47-51(2007). https://doi.org/10.1016/j.jaap.2006.10.019
- Grexa, O. and Lubke, H., "Flammability Parameters of Wood Tested on a Cone Calorimeter," Polym. Degrad. Stab. 427-432(2001).
- Lim, N. G., Her, J. W. and Park, C. W., "An Experimental Study on Flame Resistant Performance by Flame Resistant Method and Agents," J. of Korean Institute of Build. Constuct., 8(6), 117-122(2008). https://doi.org/10.5345/JKIC.2008.8.6.117
- Lee, J. W., "Burning Behavior of Interior Materials in the Cone Calorimeter and Evaluation of Toxic of Smoking," M. D. thesis, Bukyung University, Busan(2008).
- Kang, S. D., "Experimental Study on the Toxic Gases Released from the Floor Finishing Materials in Entertainment Service Industry Buildings," M. D. thesis, Seoul city University, Seoul(2002).
- Han, O. S., Han, I. S., Choi, Y. R., Lee, J. S. and Lee, S. H., "Characteristics of Flames Propagating Through Combustible Particles Concentration in a Vertical Duct," Korean Chem. Eng. Res.(HWAHAK KONGHAK), 49(1), 41-46(2011). https://doi.org/10.9713/kcer.2011.49.1.041
- Park, D. J. and Lee, Y. S., "Experimental Investigation of Explosion Pressures and Flame Propagations by Wall Obstruction Ratios and Ignition Positions," Korean J. Chem. Eng., 29(2), 139-144(2012). https://doi.org/10.1007/s11814-011-0159-5
- National Emergency Management Agency, Notice no. 2012-114, "Performance Standard of Flame Retardant".
- National Emergency Management Agency, Notice no. 2009-31, "Technical Standards of Flame Retardant Product Performance".
- DS 02-713(Defence Standard 02-713), "Determination of the Toxicity Index of the Products of Combustion from Small Specimens of Materials; Issue 2"(2002).
Cited by
- Study on the Excellent Heat Resistance Organic-Inorganic Hybrid Flame Retardant vol.30, pp.3, 2016, https://doi.org/10.7731/KIFSE.2016.30.3.067
- 유-무기 하이브리드 방염제의 성능특성에 관한 연구 vol.31, pp.4, 2017, https://doi.org/10.7731/kifse.2017.31.4.012
- 소방 실화재 훈련에서 사용하는 압축목재 가연물에서 발생하는 유해물질 특성 vol.46, pp.5, 2014, https://doi.org/10.5668/jehs.2020.46.5.555