• Title/Summary/Keyword: run length

Search Result 427, Processing Time 0.027 seconds

Percentile-based design of exponentially weighted moving average charts (지수가중이동평균 관리도의 백분위수 기반 설계)

  • Jiyun Ku;Jaeheon Lee
    • The Korean Journal of Applied Statistics
    • /
    • v.37 no.2
    • /
    • pp.177-189
    • /
    • 2024
  • The run length is defined as the number of samples or subgroups taken before the control chart statistic exceeds the control limits. Because the distribution of run length is typically asymmetric and has a large variability, it may not be appropriate to use ARL (average run length) alone to design control charts and evaluate performance. In this paper, we introduce the concept of percentile (PL)-based design of control charts, and propose the procedure for PL-based design of EWMA (exponentially weighted moving average) charts. For the PL-based design of EWMA, we present a fitted function for the control chart coefficient, given specific percentile parameters. Additionally, we perform simulations to compare the proposed design with the ARL-based design. The simulation results show that the proposed design yields improvements in monitoring in-control processes while maintaining the ability to detect out-of-control performance.

Statistical design of Shewhart control chart with runs rules (런 규칙이 혼합된 슈와르트 관리도의 통계적 설계)

  • Kim, Young-Bok;Hong, Jung-Sik;Lie, Chang-Hoon
    • Journal of Korean Society for Quality Management
    • /
    • v.36 no.3
    • /
    • pp.34-44
    • /
    • 2008
  • This research proposes a design method based on the statistical characteristics of the Shewhart control chart incorporated with 2 of 2 and 2 of 3 runs rules respectively. A Markov chain approach is employed in order to calculate the in-control and out-of-control average run lengths(ARL). Two different control limit coefficients for the Shewhart scheme and the runs rule scheme are derived simultaneously to minimize the out-of-control average run length subject to the reasonable in-control average run length. Numerical examples show that the statistical performance of the hybrid control scheme are superior to that of the original Shewhart control chart.

Statistical Design of CV Control Charts witn Approximate Distribution (근사분포를 이용한 CV 관리도의 통계적 설계)

  • Lee Man-Sik;Kang Chang-Wook;Sim Seong-Bo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.3
    • /
    • pp.14-20
    • /
    • 2004
  • The coefficient of variation(CV) which is a relatively dimensionless measure of variability is widely used to describe the variation of sample data. However, the properties of CV distribution are little available and few research has been done on estimation and interpretation of CV. In this paper, we give an outline of statistical properties of coefficient of variation and design of control chart based on this statistic. Construction procedures of control chart are presented. The proposed control chart is an efficient method to monitor a process variation for short production run situation. Futhermore, we evaluated the performance of CV control chart by average run length(ARL).

Hull Form Definition of Underwater Vehicle using NURBS Curve (NURBS곡선을 이용한 수중운동체의 선형정의)

  • Hyun-Cheol Kim;Seon-Sik Pyo;Soo-Young Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.2
    • /
    • pp.1-9
    • /
    • 1995
  • This paper suggests a numerical method that creates and varies hull form geometry of underwater vehicle. That is, it induces the cylindrical underwater vehicle from principal dimensions-total length, the length of parallel middle body, the coefficient defining entrance & run parts etc.-and represents using NURBS curve. Also, each section of hull form is varied by user interface and Sectional Area Curve is generated.

  • PDF

Ultrasonic image diagnosis using pattern recognition (패턴인식을 이용한 초음파 화상의 진단)

  • Choi, K.C.;Kim, S.I.;Lee, D.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.57-60
    • /
    • 1991
  • A new approach to texture classification for ultrasound liver diagnosis using run difference matrix was developed. The run difference matrix consists of the gray level difference along with distance. From this run difference matrix, we defined several parameters such as LDE, LDEL, NUF, SMO, SMG, SHP etc. and three vectors namely DOD, DGD and DAD. Each parameter value calculated in fatty cirrhotic, chronic hepatitic and normal liver mage was plotted in two dimensional plane. We compared our results with run length method. There are several advantages of run difference matrix method over the run lengths. 1) It is more sensitive to small difference of gray level distribution. 2) The parameters provide more statistically significant value. Images were classified with the extracted parameters to each diseases using neural networks. In preliminary clinical exprements, this approach showed satisfying results.

  • PDF

Run Representation Based Minutiae Extraction in Fingerprint (수평과 수직 Run 표현을 이용한 지문영상에서의 minutiae 추출)

  • 황희연;신정환;이준재;진성일
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.65-68
    • /
    • 2002
  • In an automatic fingerprint recognition system, a thinning process after binarization is commonly used. However it gives rise to spurs and holes often causing many spurious minutiae. Thus, more elaborate postprocessing is urgently needed to remove such spurious minutiae. To overcome this problem, we present a method of extracting minutiae based on horizontal and vertical run-length encoding from a binary fingerprint image without thinning process. Experimental results show that the proposed method for extracting minutiae is fairly reliable and fast, when il is compared to other method adopting a thinning process.

  • PDF

A new efficient algorithm for test pattern compression considering low power test in SoC (SoC환경에서의 저전력 테스트를 고려한 테스트 패턴 압축에 대한 효율적인 알고리즘)

  • 신용승;강성호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.85-95
    • /
    • 2004
  • As the design complexity increases, it is a major problem that the size of test pattern is large and power consumption is high in scan, especially system-on-a-chip(SoC), with the automatic test equipment(ATE). Because static compaction of test patterns heads to higher power for testing, it is very hard to reduce the test pattern volume for low power testing. This paper proposes an efficient compression/decompression algorithm based on run-length coding for reducing the amount of test data for low power testing that must be stored on a tester and be transferred to SoC. The experimental results show that the new algorithm is very efficient by reducing the memory space for test patterns and the hardware overhead for the decoder.

Detection of Fingerprint Ridge Direction Based on the Run-Length and Chain Codes (런길이 및 체인코드를 이용한 지문 융선의 방향 검출)

  • Lee Jeong-Hwan;Park Se-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.8
    • /
    • pp.1740-1747
    • /
    • 2004
  • In this paper, we proposed an effective method for detecting fingerprint ridge direction based on the run-length and chain codes. First, a fingerprint image is normalized, and it is thresholded to obtain binary image with foreground and background regions. The foreground regions is composed of fingerprint ridges, and the ridges is encoded with the run-length and chain codes. To detect directional information, the boundary of ridge codes is traced, and curvature is calculated at ecah point of boundary. And the detected direction value is smoothed with appropriate window locally. The proposed method is applied to NIST and FVC2002 fingerprint database to evaluate performance. By the experimental results, the proposed method can be used to obtain ridge direction value in fingerprint image.

Reduction of Test Data and Power in Scan Testing for Digital Circuits using the Code-based Technique (코드 기반 기법을 이용한 디지털 회로의 스캔 테스트 데이터와 전력단축)

  • Hur, Yong-Min;Shin, Jae-Heung
    • 전자공학회논문지 IE
    • /
    • v.45 no.3
    • /
    • pp.5-12
    • /
    • 2008
  • We propose efficient scan testing method capable of reducing the test data and power dissipation for digital logic circuits. The proposed testing method is based on a hybrid run-length encoding which reduces test data storage on the tester. We also introduce modified Bus-invert coding method and scan cell design in scan cell reordering, thus providing increased power saving in scan in operation. Experimental results for ISCAS'89 benchmark circuits show that average power of 96.7% and peak power of 84% are reduced on the average without fault coverage degrading. We have obtained a high reduction of 78.2% on the test data compared the existing compression methods.

Texture analysis of Thyroid Nodules in Ultrasound Image for Computer Aided Diagnostic system (컴퓨터 보조진단을 위한 초음파 영상에서 갑상선 결절의 텍스쳐 분석)

  • Park, Byung eun;Jang, Won Seuk;Yoo, Sun Kook
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2017
  • According to living environment, the number of deaths due to thyroid diseases increased. In this paper, we proposed an algorithm for recognizing a thyroid detection using texture analysis based on shape, gray level co-occurrence matrix and gray level run length matrix. First of all, we segmented the region of interest (ROI) using active contour model algorithm. Then, we applied a total of 18 features (5 first order descriptors, 10 Gray level co-occurrence matrix features(GLCM), 2 Gray level run length matrix features and shape feature) to each thyroid region of interest. The extracted features are used as statistical analysis. Our results show that first order statistics (Skewness, Entropy, Energy, Smoothness), GLCM (Correlation, Contrast, Energy, Entropy, Difference variance, Difference Entropy, Homogeneity, Maximum Probability, Sum average, Sum entropy), GLRLM features and shape feature helped to distinguish thyroid benign and malignant. This algorithm will be helpful to diagnose of thyroid nodule on ultrasound images.