• 제목/요약/키워드: rotor fault

검색결과 168건 처리시간 0.034초

회전자 슬롯 고조파를 이용한 유도전동기의 회전속도 검출 (Detection of Rotating Speed of Induction Motor Using the Rotor Slot Harmonic)

  • 양철오;이경석;이대성;박규남;송명현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2077-2078
    • /
    • 2011
  • Now a days, the induction motor is widely used in industry automation. Without monitoring the motor fault, maintenance cost is increased undesirably high. The slip frequency is included in the feature frequency, so rotating rotor speed is needed. In this paper, a sensorless motor speed estimation method, rotor slot harmonic(RSH) method is suggested and a solution of rotor bar diagnosis is proposed for motor running with light-load. When the rotor is rotating, it shows the harmonic signal of back-emf voltage related with number of rotor slot. So from the power spectrum of current signal, we can find the rotor speed.

  • PDF

고속 영구자석 동기전동기 구동장치의 홀센서 고장검출 및 보호제어 (Hall Sensor Fault Detection and Fault-Tolerant Control of High-Speed PMSM Drive System)

  • 장명혁;이광운
    • 전력전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.205-210
    • /
    • 2013
  • This paper presents a novel hall sensor fault detection and fault-tolerant control method for a high-speed permanent magnet synchronous motor (PMSM) drive system. A phase locked loop (PLL) type position estimator is used with a conventional interpolation based rotor position estimator to reduce position errors due to misalignment of hall sensors. The expected trigger time of hall sensor's output is used for detecting hall sensor fault condition and the PLL type position estimator is reconfigured for fault-tolerant control at the hall sensor fault condition. The proposed method can minimize current ripples during the transition from sensored control using hall sensors to sensorless control. Experimental results have been proposed to prove the validity of the proposed method.

직접토크제어 유도전동기 구동 서보시스템을 위한 장치고장 진단 기법 (An Instrument Fault Diagnosis Scheme for Direct Torque Controlled Induction Motor Driven Servo Systems)

  • 이기상;유지수
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권6호
    • /
    • pp.241-251
    • /
    • 2002
  • The effect of sensor faults in direct torque control(DTC) based induction motor drives is analyzed and a new Instrument fault detection isolation scheme(IFDIS) is proposed. The proposed IFDIS, which operated in real-time, detects and isolates the incipient fault(s) of speed sensor and current sensors that provide the feedback information. The scheme consists of an adaptive gain scheduling observer as a residual generator and a special sequential test logic unit. The observer provides not only the estimate of stator flux, a key variable in DTC system, but also the estimates of stator current and rotor speed that are useful for fault detection. With the test logic, the IFDIS has the functionality of fault isolation that only multiple estimator based IFDIS schemes can have. Simulation results for various type of sensor faults show the detection and isolation performance of the IFDIS and the applicability of this scheme to fault tolerant control system design.

Fault Tolerant Control of Magnetic Bearings with Force Invariance

  • Na, Uhn-Joo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.731-742
    • /
    • 2005
  • A magnetic bearing even with multiple coil failure can produce the same decoupled magnetic forces as those before failure if the remaining coil currents are properly redistributed. This fault-tolerant, force invariance control can be achieved with simply replacing the distribution matrix with the appropriate one shortly after coils fail, without modifying feedback control law. The distribution gain matrix that satisfies the necessary constraint conditions of decoupling linearized magnetic forces is determined with the Lagrange Multiplier optimization method.

호모폴라형 6극 자기베어링의 고장강건 제어 (Fault Tolerant Control of 6-Pole homopolar Magnetic Bearings)

  • 나언주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.826-830
    • /
    • 2004
  • Fault tolerant control method for 6-pole homopolar magnetic bearings are presented. If some of the coils or power amplifiers suddenly fail, the remaining coil currents change via a novel distribution matrix such that the same magnetic forces are maintained before and after failure. Lagrange multiplier optimization with equality constraints is utilized to calculate the optimal distribution matrix that maximizes the load capacity of the failed bearing. Some numerical examples of distribution matrices are provided to illustrate this control method.

  • PDF

풍력발전 계통연계 변압기의 결선에 따른 배전계통의 고장전류에 관한 연구 (A Study on the Fault Current of Distribution System according to Connection of Wind Turbine Generation Grid-Connected Transformer)

  • 안해준;노경수;김현구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.369-371
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

MATLAB & SIMULINK에서 풍력발전 계통연계 변압기결선과 고장전류와의 관계 (The Relationship between Wind Power Generation Grid-connected Transformer Winding Connection and Fault Current in MATLAB & SIMULINK)

  • 안해준;김현구;장길수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.307-309
    • /
    • 2008
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

Oxidation Models of Rotor Bar and End Ring Segment to Simulate Induction Motor Faults in Progress

  • Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.163-172
    • /
    • 2011
  • Oxidation models of a rotor bar and end ring segment in an induction motor are presented to simulate the behavior of an induction machine working with oxidized rotor parts which are modeled as rotor faults in progress. The leakage inductance and resistance of the rotor parts arc different from normal values because of the oxidation process. The impedance variations modify the current density and magnetic flux which pass through the oxidized parts. Consequently, it causes the rotor asymmetry which induces abnormal harmonics in the stator current spectra of the faulty machine. The leakage inductances of the oxidation models are derived by the Ampere's law. Using the proposed oxidation models, the rotor bar and end ring faults in progress can be modeled and simulated with the motor current signature analysis (MCSA). In addition, the oxidation process of the rotor bar and end ring segment can motivate the rotor asymmetry, which is induced by electromagnetic imbalances, and it is one of the major motor faults. Results of simulations and experiments are compared to each other to verify the accuracy of the proposed models. Experiments are achieved using 3.7 kW, 3-phase, and squirrel cage induction motors with a motor drive inverter.

저전압 펄스신호를 이용한 발전기 회전자 턴단락 진단 (Shorted-Turn Diagnosis Test for Generator Rotor Windings using Low Voltage Pulse Signal)

  • 이영준;김병래;황영하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2019_2020
    • /
    • 2009
  • A recurrent surge oscillograph(RSO) test was performed at the Taean thermal power plant on #5 turbine generator. The test was conducted using a rotor reflectometer and digital oscilloscope. A DC voltage step is applied to each end of the rotor winding in turn. Each reflected wave, at the input end of the winding, is monitored and the two waveforms are superimposed automatically and monitored on a single channel oscilloscope. As the half windings in a rotor are identical, the two waveforms monitored at each end of the rotor will also be identical for a healthy winding. A winding with a fault will cause different voltages to be monitored at the two ends.

  • PDF

가스터빈 발전기 회전자 권선의 절연상태 평가 (Assessment of Rotor Winding Insulation Condition for Gas Turbine Generators)

  • 김희동;김병래
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1818-1821
    • /
    • 2008
  • Several off-line diagnostic tests which include the insulation resistance(IR), polarization index(PI), low-voltage AC, and recurrent surge oscillograph(RSO) tests were performed to assess the condition of generator rotor windings. The low-voltage AC and the RSO tests were performed on the gas turbine generator rotor winding to detect shorted turns. Before intentionally applying artificial shorted faults, it was confirmed by the low voltage AC and the RSO tests that the winding was in sound condition. For simulated shorted rotor winding turns, the RSO test detected the fault in the winding. The RSO test was capable of identifying the number and pole location of the shorted turns for a number of simulated shorted coils.