• 제목/요약/키워드: response-surface design

검색결과 1,816건 처리시간 0.032초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

김치로부터 분리된 Leuconostoc sp. strain YSK 균주에 의한 덱스트란 생산 조건의 최적화 (Process Optimization of Dextran Production by Leuconostoc sp. strain YSK. Isolated from Fermented Kimchi)

  • 황승균;홍준택;정경환;장병철;황경숙;신정희;임성팔;유선균
    • 생명과학회지
    • /
    • 제18권10호
    • /
    • pp.1377-1383
    • /
    • 2008
  • 본 연구는 발효 김치 액으로부터 덱스트란 생산 균주를 분리하고 생산 최적 생산 조건을 정하기 위하여 반응표면 분석법을 이용하였다. 발효 조건의 독립변수들은 배양 온도,pH, 효모 추출물의 농도, 온도, 기질의 농도로 정하고 Box- Benken 디자인를 이용하여 실험을 설계하였다. 최종 분리된 균주는 Leuconostoc sp. strain SKY로 잠정적으로 명하였다. 연구 결과 덱스트란 생산은 3.90 - 22.40 g/l이고, 균체량 생산은 0.69-2.85 g/l, 수율은 0.10-0.64, 생산 속도 0.16-0.85 g/l-hr의 범위에서 분석이 되었다. 표면반응분석 결과 덱스트란 생산에 가장 영향을 미치는 것은 배양 pH이고 다음에 효모 추출물의 농도 그리고 온도의 순으로 나타났다. 균체량 생산에 가장 영향을 미치는 것은 배양 pH이고 다음에 효모 추출물의 농도 그리고 온도의 순으로 나타났다. 생산 수율에 가장 영향을 미치는 것은 배양 pH 이고 다음에 효모 추출물의 농도 그리고 온도의 순으로 나타났다. 덱스트란 생산 속도에 가장 영향을 미치는 것은 배양 pH이고 다음에 효모 추출물의 농도 그리고 온도의 순으로 나타났다. 결론적으로 최적 생산 조건은 온도는 $27-28^{\circ}C$이고, pH는 7.0이며, 효묘 추출물은 6-7%의 범위에서 결정이 되었다. 이러한 조건에서 생산된 덱스트란 양은 22g/l이고, 생산 수율은 약 60%정도이며, 생산 속도는 0.8g/l/hr이었다.

모과내 기능성 유용성분 용매추출공정의 최적화 (Optimization of Solvent Extraction Process on the Active Functional Components from Chinese Quince)

  • 전주영;조인희;경현규;김현아;이창민;최용희
    • 산업식품공학
    • /
    • 제14권2호
    • /
    • pp.92-98
    • /
    • 2010
  • 본 연구에서는 모과내의 여러 가지 기능성 유용성분을 효과적으로 추출하기 위해서, 모과나무의 익은 열매로 만든 약재인 모과를 사용 하였다. 모과의 기능성 유용성분 용매 추출 공정의 최적 조건을 확립하고자 하였다. 모과를 에탄올에 추출하여 반응표면 분석법으로 모니터링하여 최적 용매 조건을 설정하였다. 중심합성계획법에 따라 시료에 대한 용매비($X_{1}$)와 추출온도($X_{2}$), 추출시간($X_{3}$)을 요인변수로 하고 추출수율($Y_{1}$), 총 페놀 함량($Y_{2}$), 전자공여능($Y_{3}$), 갈색도($Y_{4}$), 환원당($Y_{5}$)을 종속변수로 하여 시행하였다. 실험 결과 추출수율은 추출 온도와 추출 시간에 유의하게 영향을 받음을 알 수 있었다. 안장점에서 추출조건은 시료에 대한 용매비는 26.38 mL/g, 추출온도는 72.82$^{\circ}C$, 추출시간은 74.86 min에서 최대값을 나타내었다. 총페놀 함량은 용매비와 시간에 영향을 거의 받지 않았고 추출시간에는 영향을 받았으며, 최대값은 20.70 mg/mL 로 나타났다. 이때의 추출조건은 시료에 대한 용매비는 22.61 mL/g, 추출온도는 84.49$^{\circ}C$, 추출시간은 77.25 min으로 나타났다. 전자공여능은 추출온도에 따라 유의하게 영향을 받은 것으로 나타났다. 안장점에서의 추출조건인 시료에 대한 용매비 10.65 mL/g, 추출온도 67.78$^{\circ}C$, 추출시간 96.75 min에서 추출수율은 94.12%로 예측되었다. 갈색도에 대한 추출조건은 시료에 대한 용매비 23.77 mL/g, 추출온도 87.27$^{\circ}C$, 추출시간 96.68 min 일 때 안장점이 나타났다. 환원당은 시료에 대한 용매비 26.83 mL/g, 추출온도 82.167$^{\circ}C$, 추출시간 81.94 min에서 10.55 mg/mL로 최대값을 나타내었고 추출시간에 영향을 받았다.

폭발하중을 받는 콘크리트 구조물의 실험적 거동분석 : (II) 초고강도 콘크리트 및 RPC 슬래브의 실험결과 (Behavior Analysis of Concrete Structure under Blast Loading : (II) Blast Loading Response of Ultra High Strength Concrete and Reactive Powder Concrete Slabs)

  • 이나현;김성배;김장호;조윤구
    • 대한토목학회논문집
    • /
    • 제29권5A호
    • /
    • pp.565-575
    • /
    • 2009
  • 최근, 테러 및 전쟁과 관련된 폭발사고가 빈번히 발생하고 있으며, 특히 도심지에서는 이러한 폭발사고로 인해 인명피해 뿐 아니라 주요 시설물에도 큰 손상이 가해져 제2차, 3차의 피해가 발생하게 된다. 폭발사고에 대하여 인명 및 시설물을 안전하게 보호하기 위해서는 기본적으로 구조물에 가해지는 폭발하중 효과에 대한 이해가 필요하다. 폭발하중은 매우 빠른 시간 내에 콘크리트 구조물에 큰 압력으로 작용하는 하중이므로 변형률 속도와 구조물의 국부적인 손상을 고려하여 동적응답을 평가해야 한다. 일반적으로, 콘크리트는 다른 건설재료에 비해 상대적으로 높은 폭발저항성을 가진 재료이지만, 일반강도 콘크리트는 충격 및 폭발하중에 대하여 충분한 저항성능을 가지지 않는다. 그러므로 방호설계에서는 고에너지 흡수력과 높은 파괴저항성을 지니는 새로운 재료의 개발이 필요하다. 본 논문에서는 최근 활발하게 연구 중인 초고강도 콘크리트(UHSC)와 Reactive Powder Concrete(RPC)에 대한 방폭성능을 평가하고자 한다. UHSC와 RPC는 강도 및 성능향상, 부재의 치수 및 중량 감소, 내진저항성 향상과 같은 장점들로 인해 초고층건물 및 초장대교량에서 사용되어지고 있다. 또한 UHSC와 RPC는 9.11테러와 같은 테러 및 충격하중에 의한 사회주요시설물의 방호설계에 적용할 수 있다. 그러므로 본 연구에서는 폭발하중에 대한 UHSC 및 RPC 구조물의 거동을 파악하기 위하여 $1.0m{\times}1.0m{\times}150mm$의 슬래브 구조물 시편을 제작하여 폭발실험을 수행하였으며, 폭발파의 특성 뿐만 아니라 최대 및 잔류 변위와 철근과 콘크리트 표면에서 변형률을 측정하여 구조물의 거동을 분석하였다. 또한 손상 및 파괴모드를 각 시편별로 측정하였다. 본 실험을 통해 UHSC 및 RPC가 일반강도콘크리트에 비해 폭발저항성이 높은 것으로 분석되었다.

공공예술로서의 인터랙티브 애니메이션 제작 연구 : 라이브 윈도우 애니메이션 <북극곰 파오> 사례를 중심으로 (A Study on Interactive Animation Production as Public Art : Focusing on an Case of the Live Window Animation, )

  • 장욱상;유승철
    • 만화애니메이션 연구
    • /
    • 통권33호
    • /
    • pp.153-172
    • /
    • 2013
  • 대부분의 공익성을 띈 콘텐츠들은 진부한 내용으로 메시지가 표면에 드러나는 경우가 많은데, 관객들은 이러한 콘텐츠를 흥미롭게 받아들이지 않는다. 애니메이션 또한 공익적 메시지를 전달하려다 보면 내용이 전반적으로 진부해질 수밖에 없는 것이 사실이다. <북극곰 파오>(PAO The Polar Bear, 2013)는 진부하고 교과서적인 내용인 지구 온난화 문제를 이야기함에 있어서 관객에게 흥미로운 경험이 되도록 하는 것에 초점을 두고 제작하였다. 또한 라이브 윈도우(Live windows)의 특성을 활용하여 애니메이션을 보는 것에 그치지 않고 관객의 참여를 통해 서사를 이루어낼 수 있도록 다중 형식 스토리(The Multiform Story)로 구성하였다. 본 논문에서는 <북극곰 파오>의 제작 사례를 통하여 극장과 라이브 윈도우에서의 차이점에 대하여 알아보고 이를 토대로 관객 참여를 위한 인터랙션 활용 사례를 살펴본다. 극장과 라이브 윈도우의 차이에 대해서는 장소의 특성에 따른 환경적 측면과 관객의 차이에 대해 분석해 보고, 인터랙션의 활용 사례는 불특정 다수를 위한 사용자 환경 디자인과 인터랙션에 대한 반응으로 서사가 바뀌는 과정을 중심으로 살펴보고 밀라노 광장에서의 상영 결과를 통해 공공예술로서의 애니메이션이 나아가야할 방향에 대하여 제시해본다. 라이브 윈도우의 특성상 <북극곰 파오>의 관객은 애니메이션을 보러 온 관객이 아니라 각기 다른 목적지를 향해 가고 있는 거리의 사람들이다. 이들을 대상으로 서사를 가진 애니메이션을 상영한다는 것은 새로운 시도였다. 밀라노 광장에서 상영이 시작되었을 때, 관객들은 본인의 참여로 이야기의 흐름이 바뀌는 경험을 통해 상당한 만족감을 느꼈으며, 흥미로운 경험의 끝에 지구 온난화 문제를 자연스럽게 떠올릴 수 있었을 것이다. <북극곰 파오>의 메시지를 통해 사람들의 습관과 생각을 얼마나 변화시켰는지 당장은 알 수 없지만 이러한 시도를 통해서 애니메이션의 사회적 역할의 가능성을 엿볼 수 있는 계기가 되었다. 세계적으로 수많은 애니메이션이 제작되고 있다. 대부분 극장과 TV, 영화제를 목표로 제작되고 있는데, 조금 더 다양한 방법을 통해서 관객과 만날 수 있어야 한다. 그 중 하나가 바로 공공예술로서의 애니메이션이고, <북극곰 파오>는 그러한 의미에서 새로운 시도였다고 할 수 있다. 또한 앞으로 공공예술로서의 애니메이션은 우리가 함께 더불어 살 수 있는 생각을 공유하고 나눌 수 있는 흥미로운 경험을 선사하기 위해 노력해야 한다. 다양한 매체의 예술이 공익을 생각하는 예술로 바뀌어가고 있는 만큼 애니메이션도 다양한 테크놀로지와 융합하여 새로운 형태의 공공예술로 나아갈 수 있을 것이다.

마이크로파 추출공정에 의한 쥐깨풀 유용성분의 추출조건 최적화 (Optimization of Microwave-Assisted Process for Extraction of Effective Components from Mosla dinthera M.)

  • 이은진;권영주;노정은;이정은;이성호;김재근;김광수;최용희;권중호
    • 한국식품저장유통학회지
    • /
    • 제12권6호
    • /
    • pp.617-623
    • /
    • 2005
  • 마이크로파에 의한 자생식물 쥐깨풀(Mosla dianthera M.)의 유용성분을 효율적으로 추출하고자 중심합성계획에 의해 마이크로파 용량($X_1,\;0\~160$ W)과 추출시간($X_2,\;1\~5$분)을 독립변수로 하여 $75\%$ 에탄을 추출물의 품질특성인 총 수율($Y_1$), 총 페놀성 화합물 함량($Y_2$), 총 플라보노이드 함량($Y_3$) 및 전자공여능($Y_4$)을 각각 종속변수로 하여 10개 조건에 따른 추출방법에 대한 반응표면 회귀분석하였다. 종속변수들에 대한 결정계수($R_2$)는 $0.8397\~0.9801$ 범위로 나타났다. 추출물 성분들의 최대 예측값과 최적 추출조건은 총 수율 $6.76\%$(microwave power 142 W, extraction time 4.36 min), 총 페놀 함량 78.68 $mg\%$(136.78 W, 4.40 min), 총 플라보노이드 함량 6.75 mg/g(159.69 W, 3.17 min) 및 전자공여능 $49.81\%$(133.87 W, 4.47 min)으로 각각 나타났다. 추출물의 기능적 품질특성을 고려한 추출조건 범위는 마이크로파 용량 $79\~l13$ W, 추출시간 $2.73\~3.84$분이었다.

GFRP로 구속된 원형단면 콘크리트 단주의 강도 및 변형 능력 (Strength and Deformation Capacities of Short Concrete Columns with Circular Section Confined by GFRP)

  • 조순호
    • 콘크리트학회논문집
    • /
    • 제19권1호
    • /
    • pp.121-130
    • /
    • 2007
  • 본 연구에서는 FRP(fiber reinforced polymer) 합성재료에 의하여 콘크리트를 구속할 시 예상되는 콘크리트의 강도 및 변형 능력의 향상 효과를 알아보기 위하여 섬유 량 혹은 방향, 단부하중조건에 따른 wrap 혹은 튜브형의 구속형태, 반원형 쉘 및 수직 이음부의 유무에 따른 연속 및 불연속 구속 형태 등을 주요 변수로 한 총 36개의 원형단주 시험체에 대하여 단조가력 실험을 수행하였다. 여러 구속 방법에 따른 FRP의 파단변형률에 대하여서도 주의를 가지고 조사하였다. 구속된 콘크리트의 최대 강도 및 변형률을 산정하기 위하여 기존에 제시된 다양한 배경의 예측 식들에 대하여 검토하였으며, 이들에 의한 예측치와 실험치를 비교, 분석하였다. 구속되지 알은 콘크리트와 비교하여, CW 및 CF형은 매우 큰 강도 및 변형능력의 증가를 나타냈으며, 수직 이음부를 갖는 CP형은 폭발적으로 파괴하였으며, 보다 작은 강도 및 변형능력의 증가가 관측되었다. 대체로, 모든 시험체는 2선 선형관계의 응력-변형률 거동을 나타냈으며, 후반부의 변형경화 정도는 구속매체의 강성에 따라 결정되었다. 모든 시험체에서 관측된 FRP의 파단변형률은 인장시험편으로부터 획득한 극한변형률보다 정도에 따라서는 매우 작았다. 대체로, 기존 예측식들은 본 실험의 최대 강도 및 변형률을 과대평가 하였으며, 변형률 예측은 매우 산란된 분포를 나타냈다. 또한, 본 연구의 실험 결과에 근거하여 구속 콘크리트의 최대 강도 및 변형률을 보다 정확하게 예측할 수 있는 설계 목적의 단순식을 제안하였다. 강도식은 모어-쿨롱 파괴 기준을 사용하여 유도하였으며, 변형률식은 비구속 콘크리트를 주요 영향 요소로 포함하여 실험 결과를 fitting하였다./TEX> = 분광광도법으로 측정한 점토함량(%); $x_2$ = 유기물 함량($g{\cdot}kg^{-1})$)이었으며, 상관계수는 $0.984^{**}$로 두 방법사이에 높은 상관관계가 있는 것으로 조사되었다. 여기서 유도된 회귀방정식을 프로그램화하여 컴퓨터나 분석기기에 입력시 시간과 공간을 절약하고 신속하고 정확하게 점토함량을 분석할 수 있을 것으로 판단된다.119>잠118>잠107>잠117>잠113 순이었고, 웅견층중에서는 잠114>잠108>잠120>잠117>잠118>잠107>잠119>잠119>잠113 순이었다. 자견층 비율에서는 광의의 귀전력이 협의의 귀전력보다 컸고, 웅견층 비율에서는 같았다, 견층 비율에서는 일반조합 능력은 크게 나타났으나, 특정조합 능력과 상반조직 능력은 나타나지 않았다. 자견층 비율에서 교배친의 우성효과는 컸다. 자견층 비율에서는 교배친의 우성효과는 적었다. 자웅견층 비율의 잡종 강세는 적게 나타났다. 환경변이와 상가적 작계는 자웅견층 비율에서는 크게 나타났다. 우성의 방향은 자견층 비율에서는 정의 방향으로 우성 귀전자가 크게 작용하였으며, 자견층 비율에서는 정의 방향으로 우성 귀전자가 부분적으로 작용하였다. 교배친의 자견층 비율의 우성순서는 잠117>잠114>잠108>잠120>잠118>잠119>잠107>잠113 순이었고, 자견층 비율에서는 잠114>잠117>잠108>잠118>잠107>잠119>잠113>잠120의 순이었다.지방산의 조성이 많은 차이를 보였다.{2+}$ 26 및 $Na^+$ 26 mg $L^{-1}$이었다. 양액 재배 후 버려지는 폐양액 중의 무기성분 함량은

건조키위 제조를 위한 삼투건조공정의 최적화 (Optimization for the Process of Osmotic Dehydration for the Manufacturing of Dried Kiwifruit)

  • 홍주헌;윤광섭;최용희
    • 한국식품과학회지
    • /
    • 제30권2호
    • /
    • pp.348-355
    • /
    • 1998
  • 건조키위의 제조시 건조에 의한 품질열화를 줄이기 위한 전처리공정으로서 삼투공정을 행하여 부분실시 계획법으로 실험계획을 수립한 후 반응표면분석법으로 최적화를 수행하여 최적조건을 얻고자 하였다. 삼투건조시 침지온도와 당농도 그리고 침지시간을 독립 변수로 하고 수분함량, solid gain, weight reduction, moisture loss, 적정산도, 당도, vitamin C를 반응변수로 하였다. 삼투건조 시 물질이동의 특성은 침지온도, 농도, 시간이 길어질수록 증가하는 것으로 나타났으며, 수분함량은 침지온도, 농도, 시간이 증가할수록 낮은 값을 보였고 당도는 침지온도와 농도 및 시간이 증가함에 따라 증가하였다. 적정산도와 vitamin C는 낮은 온도와 고농도의 처리에서 당의 보호작용으로 손실이 적게 나타났다. 수립된 회귀모형에 대한 적합성 결여분석 결과 반응변수 모두 유의성이 없어(P>0.05) 수립된 반응표면 모형이 통계적으로 유의하다고 할 수 있었으며 다중회귀분석 결과 일차항은 유의성이 인정되었다. 독립변수의 영향은 온도와 농도보다 유의성이 있었으나 시간에 대해서는 반응변수 모두 유의성이 인정되지 않았다. 독립변수중 가장 영향이 적은 침지시간인 1.5시간으로 고정하고 온도와 농도만을 변수로하여 수분함량을 $66{\sim}69%$로 하고, 당도와 vitamin C함량을 각각 $24^{\circ}Brix,\;23mg%$이상으로 하는 온도와 농도는 $34{\sim}39^{\circ}C,\;52{\sim}58^{\circ}Brix$로 나타나, 건조키위 제조를 위한 삼투처리의 최적조건을 $37^{\circ}C,\;55^{\circ}Brix$, 1.5시간으로 결정할 수 있었다.항균 효소제인 lysozyme을 분리하는데 매우 효과적인 방법이었다.제로 재차 이용할 경우 비드가 일정한 크기를 갖고, 감소한 표면적과 같은 양의 새로운 비드를 첨가한다면 사용된 비드의 재활용 가능성도 있다고 사료되었다.로 제조된 간장의 구수한 맛, 신맛, 짠맛과 종합적 기호도에서 유의차가 있어서 CM-메주로 제조한 간장보다 우수하였다. MCM-메주로 제조된 간장이 성분과 기호도에 있어서도 CM-메주로 제조된 간장보다 우수한 결과를 보였다. 일본인의 우리나라 전통적인 김치에 대한 종합적인 기호도는 염농도 2.03%, 2.63%, 1.07%의 김치 순으로 아주 싱거운 김치는 선호하지 않음을 알 수 있었다.{\;}8%+{\;}CO_2{\;}15%$ 조건이 보다 적합하였다.신증후군 재발을 경험한 응답자가 9명, 백신접종에도 불구 해당 질병 발병을 경험한 접종자가 3명, 생백신 접종 후 백신 균주에 의한 발병을 경험한 접종자가 2명이었다. 결론 : 국내의 소아 신장학 전문가들은 일반 소아에서 권장되는 예방접종 지침과는 다른 수정된 방식에 따른 예방접종을 실시하고 있었으나 아직 질병 경과와 스테로이드 사용에 따른 접종 시기에 다양성을 보이고 있었고, 또한 예방접종 후의 부작용을 경험한 경우도 다수 있었다. 따라서 향후 다수의 소아를 대상으로 한 전향적인 연구를 통하여 소아 신질한 환아에서 추천되는 예방접종 지침을 확립할 필요가 있다고 사료된다. 생리활성효과에 손색없는 것으로 판단되고, 이러한 기능성에 기초하여 chocolate, 음료 등의 식품이나 의약품의 기능성 소재로서의 산업적 응용 가능성이 높은 것으로 사료된다.대장균군이 역시 난각에서 가장 높은 빈도로 분리되었고, 난황(Yolk)에서는 극히 낮은 수준의 세균오염도를 보였다. 다양한 동물종유래 S. aureus

  • PDF

석류추출액의 청징화를 위한 효소처리조건 최적화 (Optimization of Enzyme Treatment Condition for Clarification of Pomegranate Extract)

  • 김성호;김인호;차태양;강복희;이진형;김종명;송경식;송방호;김종국;이진만
    • Applied Biological Chemistry
    • /
    • 제48권3호
    • /
    • pp.240-245
    • /
    • 2005
  • 효소처리조건에 따른 석류추출액의 청징화특성을 조사하기 위하여 효소반응온도($35{\sim}55^{\circ}C$), 시간($30{\sim}70$분) 및 농도($0.02{\sim}0.10%$)를 중심합성계획법에 의한 16개 구간으로 설정하여 탁도, 갈색도, 가용성 고형분 함량, 총당 및 환원당 함량 등을 반응 표면분석법으로 모니터링하였다. 탁도는 주로 효소반응시간에 의하여 영향을 받고 있었으며, 처리온도 $37.99^{\circ}C$, 처리시간 60.90분, 효소농도 0.08%일 때 탁도의 최소값이 0.04(O.D)로 나타났다. 갈색도는 효소농도에 가장 많은 영향을 받는 것으로 나타났으며, 처리온도와 처리시간에 대해서는 거의 영향을 받지 않는 것으로 나타났으며, 총당의 함량은 처리온도, 처리시간, 효소농도에 대해 모두 영향을 받고 있었으며, 처리온도 $39.28^{\circ}C$, 처리시간 42.04분, 효소농도 0.03%일 때 최대값 8.37%을 나타내었다. 환원당 및 고형분 함량의 경우 효소농도에 가장 많은 영향을 받고 있었으며, 환원당은 처리온도 $42.96^{\circ}C$, 처리시간 46.21분, 효소농도 0.02%일 때 최대값 7.22%를 나타내었고, 고형분 함량은 처리온도 $46.91^{\circ}C$, 처리시간 42.13분, 효소농도 0.02%일 때 최대값 8.13%으로 나타났다. 각 변수에 대한 회귀식을 구한 후 탁도 및 갈색도의 최소값에 대한 최적효소처리조건을 superimposing 한 결과 효소처리 조건은 온도 $45{\sim}50^{\circ}C$, 시간 $50{\sim}60$분 및 농도 $0.06{\sim}0.08%$이었다.

히알루론산 생산성 향상을 위한 Streptococcus zooepidemicus 균주 개량 및 발효조 배양공정 최적화 (Strain Improvement and Bioprocess Optimization for Enhanced Production of Haluronic Acid(HA) in Bioreactor Cultures of Streptococcus zooepidemicus)

  • 김수연;전계택
    • 한국미생물·생명공학회지
    • /
    • 제48권3호
    • /
    • pp.344-357
    • /
    • 2020
  • Streptococcus zooepidemicus 유래의 세포외 고분자물질인 히알루론산(hyaluronic acid) (HA)을 대량 생산하기 위해, 균주 개량, 생산배지 및 배양공정 개발에 관한 연구를 수행하였다. HA 고생산성 변이주를 선별하기 위해 약 99%의 사멸률을 보이는 ethylmethane sulfonate (EMS) 처리조건을 적용해서, 지속적인 random screening 방법으로 고생산성, 고안정성의 변이주들을 선별할 수 있었다. HA를 고농도로 생산하기 위해서는, 이 균주의 생화학 및 배양생리적 특성에 기반한 최적 배지개발이 필수적이라고 판단하여, one-factor-at-a-time (OFAT), full factorial design (FFD), steepest ascent method (SAM) 및 response surface method (RSM) (반응표면분석법)을 순차적으로 적용하여 통계적 배지 최적화 실험을 수행하였다. 최적 배지조성에서 플라스크 배양에 의한 HA 생산성은 5.38 g/l로서, 이전 배지(3.54 g/l)에 비해 약 52% 향상된 생산량을 얻을 수 있었다. 또한 선별된 우량균주와 최적화된 생산배지를 이용하여 5 L 발효조에서 배양공정 최적화 연구를 수행하였다. 이 균주의 생리학적 특성을 고려할 때, HA 생산성을 높이기 위해서는 (배양 중 HA 축적으로 인해 고점도를 띠는) 배양액으로의 충분한 용존산소 공급이 매우 중요한 요인인 것으로 판단되었다. 따라서 용존산소 공급과 밀접하게 관련있는 발효조의 교반시스템(교반 날개 종류, 크기 및 배치 등) 및 교반속도에 대한 최적화 연구를 수행하였다. 그 결과, 교반축 하부에는 Rushton turbine-type, 상부에는 marine-type의 확장된 교반날개(기존 대비 직경 1.3배 확장)가 설치된 경우, 450 rpm에서 강화된 혼합력과 충분한 용존산소 공급으로 인해 HA 생산성이 기존 플라스크 배양 대비 약 1.8배(9.79 vs. 5.38 g/l) 더 높은 것으로 확인되었다. 최종적으로 HA 배양공정의 scale-up 가능성을 확인하기 위해, pilot 규모의 50 L 발효조 배양을 최대 300 rpm의 교반속도에서 수행하였다. 처음으로 시도한 50 L 배양임에도 불구하고, HA 최대 생산성 면에서 볼 때, 5 L 발효조 결과와 거의 동일한 수준(98.5%) (9.11 vs 9.25 g/l)의 생산량을 얻을 수 있었다. 반면 지수기 성장단계인 배양 15시간까지의 50 L 배양의 HA 평균생산속도(rp)는 0.46 g/l/hr로서 0.62 g/l/hr인 5 L 배양 대비 약 74% 정도에 머무는 것으로 나타났다. 따라서 생산 발효조의 scale-up 시, 생산균주의 전단응력 민감성(shear damage)을 함께 고려하면서, 산소전달계수(kLa)를 기반으로 하는 교반시스템에 대한 체계적인 연구가 진행된다면, HA 생산속도도 증가될 수 있는 긍정적인 결과를 얻을 수 있을 것으로 기대된다.