• 제목/요약/키워드: resistive

검색결과 1,189건 처리시간 0.03초

사무실 사용용수의 수량/수질 동시 측정이 가능한 일체형 스마트 워터 미터의 현장 적용성 평가 (Evaluation of Field Applicability for All-In-One Smart Water Meter to Measure both Water Quantity and Quality in Office Building Water Usage)

  • 이새로미;오현제;주진철;안창혁;박재로
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.653-662
    • /
    • 2016
  • Recently, advanced metering infrastructure (AMI) has been recognized as a core technology of smart water grid, and the relevant market is growing constantly. In this study, we developed all-in-one smart water meter of the AMI system, which was installed on the test-bed to verify both effectiveness and field applicability in office building water usage. Developed 15 mm-diameter smart water meter is a magneto-resistive digital meter, and measures flow rate and water quality parameters (temperature, conductivity) simultaneously. As a result of the water usage analysis by installing six smart water meters on various purposes in office building water usage, the water usage in shower room showed the highest values as the 1,870 L/day and 26.6 liter per capita day (LPCD). But, the water usage in laboratory was irregular, depending on the many variables. From the analysis of the water usage based on day of the week, the water usage on Monday showed the highest value, and tended to decrease toward the weekend. According to the PCA results and multivariate statistical approaches, the shower room (Group 3) and 2 floor man's restroom sink (Group 1-3) have been classified as a separate group, and the others did not show a significant difference in both water use and water quality aspects. From the analysis of water usage measured in this study, the leak or water quality accident did not occur. Consequently, all-in-one smart water meter developed in this study can measure flow rate and water quality parameters (temperature, conductivity) simultaneously with effective field applicability in office building water usage.

진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가 (The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application)

  • 박지군;이미현;최영준;정봉재;최일홍;강상식
    • 한국방사선학회논문지
    • /
    • 제4권2호
    • /
    • pp.21-25
    • /
    • 2010
  • 최근 진단 X선 검출기 적용을 위한 방사선 검출물질로 반도체 화합물에 대한 많은 연구가 되고 있다. 본 연구에서는 반도체 화합물 중 광민감도가 우수하고 X선 흡수율이 높은 CdS 반도체를 이용하여 검출센서를 제작하였으며, 진단 X선 발생장치에서의 에너지 영역에 대한 검출 특성을 조사함으로써 적용 가능성을 평가하였다. 센서 제작은 CdS 센서로부터의 신호 획득 및 정량화를 위한 Line voltage selector(LCV)를 제작하였으며, 전압감지회로 및 정류회로부를 설계 제작하였다. 또한 X선 노출조건에 따른 상호연과 알고리즘을 이용하였으면, DAC 컨트롤러와의 Interface board를 설계 제작하였다. 성능평가는 X선 발생장치의 조사조건인 관전압, 관전류 및 조사시간별 저항변화에 따른 전압파형 특성을 오실로스코프로 획득하여 ANOVA 프로그램을 이용하여 데이터를 통계 처리 및 분석하였다. 측정결과, 관전압과 관전류이 증가할수록 오차의 비가 감소하였으며, 90kVp에서 6%, 320 mA에서 0.4% 이하의 좋은 특성을 보였으며, 결정계수는 약 0.98로 1:1의 상관관계를 보였다. X선 조사시간에 따른 오차율은 CdS 물질의 늦은 반응속도에 기인하여 조사시간이 길어질수록 지수적으로 감소하는 것을 알 수 있었으며, 320 msec에서 2.3%의 오차율을 보였다. 끝으로 X선 선량에 따른 오차율은 약 10% 이하였으며, 0.9898의 결정계수로 매우 높은 상관관계를 보였다.

철근콘크리트 T형보의 전단 보강 특성에 관한 연구 (A Study on the Shear Strengthening Characteristic of Reinforced Concrete T-shaped Beams)

  • 김정섭;신용석;문금환;유명환;이창현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.10-18
    • /
    • 2012
  • 기존 보강에 대한 연구는 대부분 장방형 보에 대해 휨 보강에 대한 연성 및 내력 증대에 대하여 주로 연구가 되었다. 그리고 일반적으로 철근콘크리트 보-슬래브 구조에서는 시공의 특성상 보와 슬래브의 콘크리트가 동시에 부어넣기되기 때문에 경화 후 일체가 되어 인접한 슬래브는 보의 플랜지를 이루어 보의 강성을 높이고 압축응력을 지지하는 면적을 넓혀 주는 T형보단면을 갖지만 T형보의 휨 거동에 대해 유용한 자료는 부족한 실정이다. 본 연구는 철근콘크리트 T형보를 제작하여 보강재 종류와 위치별로 전단 보강을 실시하여 보강효과 및 구조적 특성을 파악하였으며 다음과 같은 결론을 얻었다. 각종 실험결과를 종합한바, 탄소섬유막대 보강은 콘크리트 내부에 매입되어 일체 거동함으로써 파괴시 거동 및 내력 및 강성 향상 면에서 가장 우수한 것으로 나타났다. 강판 보강은 강성 및 전단내력은 증대 되었으나 보강강도는 큰데 반해 콘크리트와 부착성 저하에 의해 낮은 보강효과를 보였다. 섬유시트 보강은 보강효과는 우수하나 파괴 시 부착성의 한계로 의해 계면박리가 나타나 이에 대한 대책이 필요할 것으로 사료된다.

동기식 256-bit OTP 메모리 설계 (Design of Synchronous 256-bit OTP Memory)

  • 이용진;김태훈;심외용;박무훈;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제12권7호
    • /
    • pp.1227-1234
    • /
    • 2008
  • 본 논문에서는 자동차 전장용 Power IC, 디스플레이 구동 칩, CMOS 이미지 센서 등의 응용분야에서 필요로 하는 동기식 256-bit OTP(one-time programmable) 메모리를 설계하였다. 동기식 256-bit OTP 메모리의 셀은 고전압 차단 트랜지스터 없이 안티퓨즈인 NMOS 커패시터와 액세스 트랜지스터로 구성되어 있다. 기존의 3종류의 전원 전압을 사용하는 대신 로직 전원 전압인 VDD(=1.5V)와 외부 프로그램 전압인 VPPE(=5.5V)를 사용하므로 부가적인 차단 트랜지스터의 게이트 바이어스 전압 회로를 제거하였다. 그리고 프로그램시 전류 제한 없이 전압 구동을 하는 경우 안티퓨즈의 ON 저항 값과 공정 변동에 따라 프로그램 할 셀의 부하 전류가 증가한다. 그러므로 프로그램 전압은 VPP 전원 선에서의 저항성 전압 감소로 인해 상대적으로 증가하는 문제가 있다. 그래서 본 논문에서는 전압 구동 대신 전류 구동방식을 사용하여 OTP 셀을 프로그램 할 때 일정한 부하전류가 흐르게 한다. 그래서 웨이퍼 측정 결과 VPPE 전압은 5.9V에서 5.5V로 0.4V 정도 낮출 수 있도록 하였다. 또한 기존의 전류 감지 증폭기 대신 Clocked 인버터를 사용한 감지 증폭기를 사용하여 회로를 단순화시켰다. 동기식 256-bit OTP IP는 매그나칩 반도체 $0.13{\mu}m$ 공정을 이용하여 설계하였으며, 레이아웃 면적은 $298.4{\times}3.14{\mu}m2$이다.

나노급 수소화된 비정질 실리콘층 두께에 따른 저온형성 니켈실리사이드의 물성 연구 (Property of Nickel Silicides with Hydrogenated Amorphous Silicon Thickness Prepared by Low Temperature Process)

  • 김종률;최용윤;박종성;송오성
    • 대한금속재료학회지
    • /
    • 제46권11호
    • /
    • pp.762-769
    • /
    • 2008
  • Hydrogenated amorphous silicon(a-Si : H) layers, 120 nm and 50 nm in thickness, were deposited on 200 $nm-SiO_2$/single-Si substrates by inductively coupled plasma chemical vapor deposition(ICP-CVD). Subsequently, 30 nm-Ni layers were deposited by E-beam evaporation. Finally, 30 nm-Ni/120 nm a-Si : H/200 $nm-SiO_2$/single-Si and 30 nm-Ni/50 nm a-Si:H/200 $nm-SiO_2$/single-Si were prepared. The prepared samples were annealed by rapid thermal annealing(RTA) from $200^{\circ}C$ to $500^{\circ}C$ in $50^{\circ}C$ increments for 30 minute. A four-point tester, high resolution X-ray diffraction(HRXRD), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), and scanning probe microscopy(SPM) were used to examine the sheet resistance, phase transformation, in-plane microstructure, cross-sectional microstructure, and surface roughness, respectively. The nickel silicide on the 120 nm a-Si:H substrate showed high sheet resistance($470{\Omega}/{\Box}$) at T(temperature) < $450^{\circ}C$ and low sheet resistance ($70{\Omega}/{\Box}$) at T > $450^{\circ}C$. The high and low resistive regions contained ${\zeta}-Ni_2Si$ and NiSi, respectively. In case of microstructure showed mixed phase of nickel silicide and a-Si:H on the residual a-Si:H layer at T < $450^{\circ}C$ but no mixed phase and a residual a-Si:H layer at T > $450^{\circ}C$. The surface roughness matched the phase transformation according to the silicidation temperature. The nickel silicide on the 50 nm a-Si:H substrate had high sheet resistance(${\sim}1k{\Omega}/{\Box}$) at T < $400^{\circ}C$ and low sheet resistance ($100{\Omega}/{\Box}$) at T > $400^{\circ}C$. This was attributed to the formation of ${\delta}-Ni_2Si$ at T > $400^{\circ}C$ regardless of the siliciation temperature. An examination of the microstructure showed a region of nickel silicide at T < $400^{\circ}C$ that consisted of a mixed phase of nickel silicide and a-Si:H without a residual a-Si:H layer. The region at T > $400^{\circ}C$ showed crystalline nickel silicide without a mixed phase. The surface roughness remained constant regardless of the silicidation temperature. Our results suggest that a 50 nm a-Si:H nickel silicide layer is advantageous of the active layer of a thin film transistor(TFT) when applying a nano-thick layer with a constant sheet resistance, surface roughness, and ${\delta}-Ni_2Si$ temperatures > $400^{\circ}C$.

Seawater ballast tank 환경에서 저합금강의 내식성에 미치는 합금원소의 영향 (Effects of Alloying Elements on Corrosion Resistance of Low Alloyed Steels in a Seawater Ballast Tank Environment)

  • 김동우;김희산
    • 대한금속재료학회지
    • /
    • 제48권6호
    • /
    • pp.523-532
    • /
    • 2010
  • Co-application of organic coating and cathodic protection has not provided enough durability to low-alloyed steels inseawater ballast tank (SBT) environments. An attempt has made to study the effect of alloy elements (Al, Cr, Cu, Mo, Ni, Si, W) on general and localized corrosion resistance of steels as basic research to develop new low-allowed steels resistive to corrosion in SBT environments. For this study, we measured the corrosion rate by the weigh loss method after periodic immersion in synthetic seawater at $60^{\circ}C$, evaluated the localized corrosion resistance by an immersion test in concentrated chloride solution with the critical pH depending on the alloy element (Fe, Cr, Al, Ni), determined the permeability of chloride ion across the rust layer by measuring the membrane potential, and finally, we analyzed the rust layer by EPMA mapping and compared the result with the E-pH diagram calculated in the study. The immersion test of up to 55 days in the synthetic seawater showed that chromium, aluminium, and nickel are beneficial but the other elements are detrimental to corrosion resistance. Among the beneficial elements, chromium and aluminium effectively decreased the corrosion rate of the steels during the initial immersion, while nickel effectively decreased the corrosion rate in a longer than 30-day immersion. The low corrosion rate of Cr- or Al-alloyed steel in the initial period was due to the formation of $Cr_2FeO_4$ or $Al_2FeO_4$, respectively -the predicted oxide in the E-pH diagram- which is known as a more protective oxide than $Fe_3O_4$. The increased corrosion rate of Cr-alloyed steels with alonger than 30-day exposure was due to low localized corrosion resistance, which is explained bythe effect of the alloying element on a critical pH. In the meantime, the low corrosion rate of Ni-alloyed steel with a longer than 30-day exposure wasdue to an Ni enriched layer containing $Fe_2NiO_4$, the predicted oxide in the E-pH diagram. Finally, the measurement of the membrane potential depending on the alloying element showed that a lower permeability of chloride ion does not always result in higher corrosion resistance in seawater.

프리스탠딩 저항형 가스 센서용 산화구리 무전해 도금 탄소스펀지 제조 및 일산화질소 감지 (Fabrication of Copper(II) Oxide Plated Carbon Sponge for Free-standing Resistive Type Gas Sensor and Its Application to Nitric Oxide Detection)

  • 김석진;하성민;명성재;이영석
    • 공업화학
    • /
    • 제33권6호
    • /
    • pp.630-635
    • /
    • 2022
  • 멜라민 스펀지를 열처리하여 제조된 질소함유 탄소 스펀지에 산화구리(CuO)를 무전해 도금하여 기판없이 작동하는 일산화질소(NO) 가스 센서를 제조하였다. 탄소 스펀지 표면의 CuO 함량은 도금 시간이 증가함에 따라 증가하였으나, NO 가스 흡착을 유도한다고 알려져 있는 질소의 함량은 CuO 표면 함량이 증가함에 따라 감소하였다. 미처리 탄소스펀지는 NO 가스에 대하여 18 min에 최대 저항 변화(5.0%)를 나타내었다. 반면에, CuO가 도금된 샘플(CuO30s-CS)은 8 min만에 최대 18.3%의 저항변화를 보였다. 이러한 NO 가스 감지 능력 향상은 CuO로 인하여 탄소 스펀지의 정공 캐리어 수 증가 및 전자전달 촉진에 기인하는 것으로 판단된다. 그러나, 60 s 동안 CuO 무전해 도금된 탄소 스펀지의 NO가스 감지 저항은 1.9%로 오히려 감소하였다. 이는 탄소 스펀지 표면에 CuO로 완전히 도금되어 NO 가스 흡착 능력이 떨어져 저항변화가 감소한 것으로 판단된다. 따라서, CuO가 도금된 탄소 스펀지는 빠르고 우수한 저항변화 특성을 가지고 있어 유용한 NO 가스 센서로 사용할 수 있으나, CuO가 탄소 스펀지 표면을 완전히 도금해서는 안 된다.

비정질 탄소가 제거된 흑연을 이용한 황화물계 전고체 리튬이온전지 음극소재 전기화학적 특성 분석 (Analysis of Electrochemical Properties of Sulfide All-Solid-State Lithium Ion Battery Anode Material Using Amorphous Carbon-Removed Graphite)

  • 최재홍;오필건
    • 공업화학
    • /
    • 제33권1호
    • /
    • pp.58-63
    • /
    • 2022
  • 흑연은 낮은 탈/리튬화 전압, 372 mAh/g의 높은 이론 용량, 낮은 가격 및 긴 수명 특성을 가져 지난 30년 동안 리튬이 온전지 음극 재료로 활용되었다. 최근 무기 고체 재료로 구성되어 높은 안정성을 가지는 전고체 리튬이온전지는 전기자동차 및 차세대 에너지 저장 장치로 엄청난 주목을 받고 있지만, 전고체 리튬이온전지 시스템에 잘 구동되는 흑연 연구는 부족한 실정이다. 그래서 우리는 탄소재료 표면에 존재하여 저항층으로 작용하는 비정질 탄소를 흑연으로부터 제거하여 흑연의 전기전도도 향상을 통해 황화물계 전고체 전지 음극 흑연 재료의 성능 향상을 유도했다. 400, 500 및 600 ℃ 공기 열처리된 흑연의 X-ray diffraction (XRD) 분석 결과, (002) 피크 반치폭(FWHM)이 bare 흑연보다 줄어들어 열처리 후 흑연의 결정성이 향상됨을 보였다. 또한 열처리 후 흑연의 결정성이 증가할수록 방전 용량, 초기 쿨롱효율(ICE) 및 수명 특성이 증가함을 확인했다. 500 ℃ 공기 열처리 한 흑연의 경우 331.1 mAh/g 및 ICE 86.2%와 10사이클 수명 측정 후 92.7%의 높은 용량 유지율을 나타내었다.

리튬 이온 기반 멤리스터 커패시터 병렬 구조의 저항변화 특성 연구 (A Study on the Resistve Switching Characteristic of Parallel Memristive Circuit of Lithium Ion Based Memristor and Capacitor)

  • 강승현;이홍섭
    • 마이크로전자및패키징학회지
    • /
    • 제28권4호
    • /
    • pp.41-45
    • /
    • 2021
  • 본 연구에서는 멤리스터 소자의 높은 신뢰성을 확보하기 위해 소자 제작 단계에서 30 nm 두께의 ZrO2 금속산화물 박막 위 국부영역에 리튬 filament seed 층을 패턴하여 작은 이온반경의 리튬이온을 저항변화 주체로 활용하는 멤리스터 소자를 구현하였다. 패턴 된 리튬 filament seed 대비 다양한 상부전극의 면적을 적용하여 멤리스터-커패시턴스 병렬 구조의 이온형 저항변화 소자에서 커패시턴스가 filament type 저항변화 특성에 미치는 영향을 조사하고자 하였다. 이를 위해 ZrO2 박막 위에 5 nm 두께, 5 ㎛ × 5 ㎛ 면적의 리튬 filament seed 증착 후 50 ㎛, 100 ㎛ 직경의 상부전극을 증착, 리튬 메탈의 확산을 위한 250℃ 열처리 전 후 샘플에서 저항변화 특성을 확인하였다. 열확산에 의해 형성된 전도성 filament의 경우 전압에 의한 제어가 불가함을 확인하였으며, 전압에 의해 형성된 filament만이 electrochemical migration에 의한 가역적 저항변화 특성 구현이 가능한 것을 확인하였다. 전압에 의한 filament 형성 시 병렬로 존재하는 커패시턴스의 크기가 filament의 형성 및 소실에 중요한 인자임을 확인하였다.

Comparison of Kinematics and Myoelectrical Activity during Deadlift, with and without Variable Banded Resistance, in Healthy, Trained Athletes

  • Everett B. Lohman;Mansoor Alameri;Fulden Cakir;Chih Chieh Chia;Maxine Shih;Owee Mulay;Kezia Marceline;Simran Jaisinghani;Gurinder Bains;Michael DeLeon;Noha Daher
    • Physical Therapy Rehabilitation Science
    • /
    • 제13권1호
    • /
    • pp.53-70
    • /
    • 2024
  • Background: The conventional deadlift is a popular exercise for enhancing trunk, core, and lower extremity strength. However, its use in sports medicine is constrained by concerns of lumbar injuries, despite evidence supporting its safety and rehabilitative benefits. To optimize muscle activation using resistive bands in variable resistance therapy, we explored their feasibility in the deadlift. Design: Comparative experimental design Methods: Surface electromyography recorded muscle activity in the trunk and lower extremities during lifting, with normalization to the isometric Floor Lift using Maximal Voluntary Contraction. Kinematics were measured using inclinometer sensors to track hip and trunk sagittal plane angles. To prevent fatigue, each subject only used one of the three pairs of bands employed in the study. Results: Our study involved 45 healthy subjects (mean age: 30.4 ± 6.3 years) with similar baseline characteristics, except for years of lifting and strength-to-years-of-lifting ratio. Various resistance band groups exhibited significantly higher muscle activity than conventional deadlifts during different phases. The minimal resistance band group had notably higher muscle activity in the trunk, core, and lower extremity muscles, particularly in the end phase. The moderate resistance band group showed increased muscle activity in the mid-and end-phases. The maximum resistance band group demonstrated greater muscle activity in specific muscles during the early phase and overall higher activity in all trunk and lower extremity muscles in the mid and end phases of the deadlift (p<0.05). Conclusion: Our findings provide valuable insights into muscle activation with various resistance bands during deadlift exercise in clinical and gym settings. There appears to be a dose-response relationship between increased resistance bandwidth, external load, myoelectric activation, and range.