• 제목/요약/키워드: pulse width distortion

검색결과 109건 처리시간 0.022초

더블 게이트 박막 트랜지스터를 활용한 Micro LED 디스플레이 화소 회로 설계 (Design of Pixel Circuit of Micro LED Display with Double Gate Thin Film Transistors)

  • 김태수;전재홍
    • 반도체디스플레이기술학회지
    • /
    • 제21권1호
    • /
    • pp.50-55
    • /
    • 2022
  • Due to the wavelength shift problem of micro LED caused by the change of current density, the active matrix driving pixel circuit that is used in OLED cannot be applied to micro LED displays. Therefore, we need a gray scale method based on modulation of duration time of light emission. In this study, we propose the PWM-controlled micro LED pixel circuit based on CMOS thin film transistors (TFTs). By adopting CMOS inverter structure, we can reduce the number of storage capacitors from the circuit and make the operating speed of the circuit faster. Most of all, our circuit is designed to make operating speed of PWM circuit faster by adopting feedback effect through double gate TFT structure. As a result, it takes about 4.7ns to turn on the LED and about 5.6ns to turn it off. This operating time is short enough to avoid the color distortion and help the precise control of the gray scale.

Optimized Low-Switching-Loss PWM and Neutral-Point Balance Control Strategy of Three-Level NPC Inverters

  • Xu, Shi-Zhou;Wang, Chun-Jie;Han, Tian-Cheng;Li, Xue-Ping;Zhu, Xiang-Yu
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.702-713
    • /
    • 2018
  • Power loss reduction and total harmonic distortion(THD) minimization are two important goals of improving three-level inverters. In this paper, an optimized pulse width modulation (PWM) strategy that can reduce switching losses and balance the neutral point with an optional THD of three-level neutral-point-clamped inverters is proposed. An analysis of the two-level discontinuous PWM (DPWM) strategy indicates that the optimal goal of the proposed PWM strategy is to reduce switching losses to a minimum without increasing the THD compared to that of traditional SVPWMs. Thus, the analysis of the two-level DPWM strategy is introduced. Through the rational allocation of the zero vector, only two-phase switching devices are active in each sector, and their switching losses can be reduced by one-third compared with those of traditional PWM strategies. A detailed analysis of the impact of small vectors, which correspond to different zero vectors, on the neutral-point potential is conducted, and a hysteresis control method is proposed to balance the neutral point. This method is simple, does not judge the direction of midpoint currents, and can adjust the switching times of devices and the fluctuation of the neutral-point potential by changing the hysteresis loop width. Simulation and experimental results prove the effectiveness and feasibility of the proposed strategy.

저속 센서리스 제어의 역기전력 추정 성능 향상을 위한 모터 파라미터 추정과 전압 오차의 개선 (Identification of Motor Parameters and Improvement of Voltage Error for Improvement of Back-emf Estimation in Sensorless Control of Low Speed Operation)

  • 김경훈;윤철;조내수;장민호;권우현
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.635-643
    • /
    • 2018
  • This paper propose a method to identify the motor parameters and improve input voltage error which affect the low speed position error of the back-emf(back electromotive force) based sensorless algorithm and to secure the operation reliability and stability even in the case where the load fluctuation is severe and the start and low speed operation frequently occurs. In the model-based observer used in this paper, stator resistance, inductance, and input voltage are particularly influential factors on low speed performance. Stator resistance can cause resistance value fluctuation which may occur in mass production process, and fluctuation of resistance value due to heat generated during operation. The inductance is influenced by the fluctuation due to the manufacturing dispersion and at a low speed where the change of the current is severe. In order to find stator resistance and inductance which have different initial values and fluctuate during operation and have a large influence on sensorless performance at low speed, they are commonly measured through 2-point calculation method by 2-step align current injection. The effect of voltage error is minimized by offsetting the voltage error. In addition, when the command voltage is used, it is difficult to estimate the back-emf due to the relatively large distortion voltage due to the dead time and the voltage drop of the power device. In this paper, we propose a simple circuit and method to detect the voltage by measuring the PWM(Pulse Width Modulation) pulse width and compensate the voltage drop of the power device with the table, thereby minimizing the position error due to the exact estimation of the back-emf at low speed. The suitability of the proposed algorithm is verified through experiment.

Modelling a Stand-Alone Inverter and Comparing the Power Quality of the National Grid with Off-Grid System

  • Algaddafi, Ali;Brown, Neil;Rupert, Gammon;Al-Shahrani, Jubran
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권1호
    • /
    • pp.35-42
    • /
    • 2016
  • Developments in power electronics have enabled the widespread application of Pulse Width Modulation (PWM) inverters, notably for connecting renewable systems to the grid. This study demonstrates that a high-quality power can be achieved using a stand-alone inverter, whereby the comparison between the power quality of the stand-alone inverter with battery storage (off-grid) and the power quality of the utility network is presented. Multi-loop control techniques for a single phase stand-alone inverter are used. A capacitor current control is used to give active damping and enhance the transient and steady state inverter performance. A capacitor current control is cheaper than the inductor current control, where a small current sensing resistor is used. The output voltage control is used to improve the system performance and also control the output voltage. The inner control loop uses a proportional gain current controller and the outer loop is implemented using internal model control proportional-integral-derivative to ensure stability. The optimal controls are achieved by using the Sisotool tool in MATLAB/Simulink. The outcome of the control scheme of the numerical model of the stand-alone inverter has a smooth and good dynamic performance, but also a strong robustness to load variations. The numerical model of the stand-alone inverter and its power quality are presented, and the power quality is shown to meet the IEEE 519-2014. Furthermore, the power quality of the off-grid system is measured experimentally and compared with the grid power, showing power quality of off-grid system to be better than that of the utility network.

단상 UPS 인버터의 강인한 2중 데드비트제어 (Robust Double Deadbeat Control of Single-Phase UPS Inverter)

  • 박지호;허태원;안인모;이현우;정재륜;우정인
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.65-72
    • /
    • 2001
  • 본 논문에서는 UPS용 인버터의 강인한 디지털제어를 위하여 인버터 출력측 LC필터의 커패시터 전압과 전류의 2중 제어루프로 구성된 새로운 제어기법을 제안한다. 제안된 전압·전류의 2중 제어루프는 전압 제어루프의 커패시터 전압을 전류 제어루프의 커패시터 전류의 위상중심으로 두고, 2중 데드비트 제어를 수행함으로써 커패시터 전류의 위상지연이 보상된 완전한 진상전류 제어가 가능하게 된다. 전류 제어루프는 디지털 제어기의 시간 지연요소를 시스템의 고유한 파라미터로 가정한 2차 데드비트 제어기로 설계하여 디지털 제어기의 고유한 연산 지연시간에 의한 성능저하를 개선한다. 또한, 외란에 의한 데드비트 제어의 영향을 제거하기 위하여 부하전류 예측기법을 전류 제어루프에 부가하여 외란을 피드포워드 보상함으로써 외란에 강인한 전류제어를 수행한다.

  • PDF

1-비트 4차 델타-시그마 변조기법을 이용한 D급 디지털 오디오 증폭기 (Class-D Digital Audio Amplifier Using 1-bit 4th-order Delta-Sigma Modulation)

  • 강경식;최영길;노형동;남현석;노정진
    • 대한전자공학회논문지SD
    • /
    • 제45권3호
    • /
    • pp.44-53
    • /
    • 2008
  • 본 논문에서는 휴대용 오디고 제품의 헤드폰 구동을 위한 델타-시그마 변조기법 기반의 D급 증폭기를 제안한다. 제안된 D급 증폭기는 고성능 단일 비트 4차 델타-시그마 변조기를 이용하여 펄스폭 변조 신호를 발생시킨다. 높은 신호 대 잡음비를 얻는 것과 동시에 시스템의 안정성 확보를 위하여 시뮬레이션을 통해 변조기 루프필터의 폴과 제로를 최적화하였다. 테스트 칩은 $0.18{\mu}m$ CMOS 공정으로 제작되었다. 칩 면적은 $1.6mm^2$ 이며, 20Hz 부터 20kHz까지의 신호대역을 대상으로 동작한다. 3V 전원전압과 32옴의 로드를 사용하여 측정된 출력은 0.03% 이하의 전고조파 왜율을 갖는다.

Optimal Selection of Arm Inductance and Switching Modulation for Three-Phase Modular Multilevel Converters in Terms of DC Voltage Utilization, Harmonics and Efficiency

  • Arslan, Ali Osman;Kurtoglu, Mehmet;Eroglu, Fatih;Vural, Ahmet Mete
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.922-933
    • /
    • 2019
  • The arm inductance (AI) of a modular multilevel converter (MMC) affects both the fault and circulating current magnitudes. In addition, it has an impact on the inverter efficiency and harmonic content. In this study, the AI of a three-phase MMC is optimized in a novel way in terms of DC voltage utilization, harmonics and efficiency. This MMC has 10 submodules (SM) per arm and the power circuit topology of the SM is a half-bridge. The optimum AI is adopted and verified in an MMC that has 100 SMs per arm. Then the phase shift (PS) and phase disposition (PD) pulse width modulation (PWM) methods are investigated for better DC voltage utilization, efficiency and harmonics. It is found that similar performances are obtained for both modulation techniques in terms of DC voltage utilization. However, the total harmonic distortion (THD) of the PS-PWM is found to be 0.02%, which is slightly lower than the THD of the PD-PWM at 0.16%. In efficiency calculations, the switching and conduction losses for all of the semiconductor are considered separately and the minimum efficiency of the 100-SM based MMC is found to be 99.62% for the PS-PWM and 99.64% for the PD-PWM with the optimal value of the AI. Simulation results are verified with an experimental prototype of a 6-SM based MMC.

IR-UWB를 이용한 빔 스캐닝 배열 안테나 설계 및 연구 (A Study and Design of Beam Scanning Array Antenna using IR-UWB)

  • 김근용;강은균;김진우;나극환
    • 전자공학회논문지
    • /
    • 제51권3호
    • /
    • pp.194-201
    • /
    • 2014
  • 본 논문에서는 TRM(Transmitter-Receiver Module)을 사용하여 각 안테나에 펄스의 위상을 조정함으로써 빔 패턴 각도를 조정하여 다중 경로 환경에서의 성능저하를 향상시킬 수 있다. 다중 경로 환경에서 성능저하를 향상시키는 임펄스 신호를 왜곡 없이 송 수신하는 빔 스캐닝 시스템(Beam Scanning System)을 설계 및 제작 하였다. 빔 스캐닝 시스템은 안테나 종단 부분에서 신호가 왜곡 없이 송 수신이 가능하여 하며 타 시스템에 영향을 미치지 않아야 한다. 또한 빔 조향을 통하여 표적에 대한 감지 능력도 있어야 한다. 설계한 빔 스캐닝 안테나의 분산특성은 충실도(Fidelity)를 사용하여 분석을 하고 조향과 레이더 해상도(Radar Resolution) 성능은 $1cm{\times}1cm$ 표적의 크기를 사용하여 그 성능을 확인한다. 빔 스캐닝 배열 안테나를 제작하기 위해 IR-UWB(Impulse Radio)용 비발디 안테나(Vivaldi Antenna), 삼중대역 윌킨슨 전력 분배기(Tri-Band Wilkinson power divider), TRM(Transmitter-Receiver Module), 송 수신 모듈(TRM)을 컨트롤 할 수 있는 컨트롤 보드 및 GUI 설계를 하였다. 본 연구를 통해 개발된 UWB 빔 스캐닝 시스템은 빔 패턴 각도를 조정하여 다중 경로 환경에서의 성능저하를 향상시킬 수 있으며, 네트워크 분석기를 이용한 시간영역 분석기술은 안테나 설계 시 안테나의 특성을 정확히 분석을 할 수 있고 손쉽게 빔 폭을 확인 할 수가 있다. 설계한 빔 스캐닝 시스템은 레이더 응용 분야인 지표투과 레이더, 벽 투과 레이더, 의료영상 레이더, 탐색 및 구조 레이더, 비파괴 탐상 레이더 및 무선통신 시스템에 사용 적용이 가능하다.

PXI를 이용한 다목적 물리탐사 측정 시스템 (Multi-purpose Geophysical Measurements System Using PXI)

  • 조성준;김정호;성낙훈;정지민
    • 지구물리와물리탐사
    • /
    • 제8권3호
    • /
    • pp.224-231
    • /
    • 2005
  • 현장 물리탐사 수행 시 상용화된 장비로는 탐사 대상 매질의 물성, 대상체의 크기, 모양 등의 탐사목적 및 현장여건에 의해 탐사가 불가능 하거나 탐사 목적에 맞는 분해능을 얻지 못하는 경우를 종종 만나게 된다. 이러한 다양한 현장 조건 및 탐사 목적에 효과적으로 적용할 수 있는 다목적 물리탐사 측정 시스템을 개발하였다. 이 다목적 측정 시스템은 PXI를 기반으로 하며 A/D 변환기 또는 GPIB 인터페이스를 이용한 측정 장치를 통해 신호를 측정하게 되며 확장성이 커 다양한 문제에 적용이 가능하다. 구성된 측정 시스템을 이용하여 시추공 레이다 탐사 시스템과 시추공 초음파 탐사 시스템, 전자기적 잡음 측정 시스템을 구축하였다. 시추공 레이다 탐사 시스템은 네트워크 분석기를 GPIB를 통해 제어하고 현장 조건에 따라 임의로 안테나의 길이 조절이 가능한 스텝 주파수 레이다 탐사 시스템이며, 시추공 초음파 탐사 시스템은 압전 송수신기 센서, 고출력 송신기와 A/D 변환기로 구성되어 시추공 내에서 초음파를 이용하여 착맥된 지하공동의 범위를 측정하기 위해 구성된 시스템이며, 전자기적 잡음 측정 시스템은 3개의 자기장 센서와 2개의 전기장 센서 그리고 A/D 변환기로 구성되며 임의로 측정시간과 샘플링 주파수의 조절이 가능하고 임의의 시간에 예약 측정이 가능한 시스템이다. 시추공 레이다 탐사 시스템은 상용 시스템으로 불가능했던 지하공동의 넓이와 지장물을 찾는 탐사에서 효과적인 결과를 보여주었으며, 시추공 초음파 탐사 시스템도 지하공동의 넓이를 측정하는 실험에서 가능성을 확인할 수 있었다. 한편 전자기적 잡음 측정 시스템을 이용하여 도심지 내 전자기적 잡음특성을 파악할 수 있었으며, 이를 변형하여 전기비저항 탐사 시 사용되는 다양한 케이블에 대한 케이블 내의 전자기적 유도 현상 및 그에 따른 신호 왜곡을 규명하는 실험에 적용하여 시스템의 확장성을 확인하였다.