• Title/Summary/Keyword: porous concrete

Search Result 312, Processing Time 0.023 seconds

A Study of Developing Guides for the Construction Site Quality Control of Porous Concrete (투수콘크리트 현장품질관리 지침서 개발에 관한 연구)

  • Ko, Eun-Jung;Goh, Eun-Joo;Seok, Ho-Joong;Lee, Seung-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.3
    • /
    • pp.65-71
    • /
    • 2009
  • General criteria for the quality of porous concrete have not been established yet in Korea. And yet, pavement and construction have been performed. In this paper, guidelines on the construction site quality control of porous concrete were developed in order to establish criteria for resolving the issues and problems of porous concrete, to establish methods for improving poor performance, and to manage porous concrete more systematically. In addition, a guide for the construction site quality control of porous concrete, which was appropriate for reality, was developed by researching several quality control guides and maintenance at construction sites. The guide consists of a total of nine chapters such as Application Range, Overview, the Structure of Porous Concrete, the Design of Package Thickness, Package Materials for Porous Concrete, Construction Methods, Quality Assurance and Inspections, Construction Site Quality Control, and Maintenance. It describes quality control guidelines in all steps such as methods for transporting porous concrete from the factory to the construction site, cautions for construction work at construction sites, maintenance, and management. The Guide for the Construction Site Quality Control of Porous Concrete is expected to ensure the quality of porous concrete, to reduce national costs for quality assurance, and to help ensure the health and safety of Korean people.

pH Reduction of High Porous Concrete to Grow Plants (식생을 위한 다공성 콘크리트의 pH 저감에 대한 실험적 연구)

  • 박찬규;정재홍;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1129-1134
    • /
    • 2001
  • In the point of the Eco-concrete(Environmentally Friendly Concrete), it is very important to reduce the pH of high porous concrete by the pH to be able to grow plants, because the pH of concrete is l1~13. But the method of measuring the pH of high porous concrete is not well-defined, yet. Therefore, first, this paper report the method of measuring the pH of high porous concrete. Secondly this paper reports the pH reduction of high porous concrete to grow plants.

  • PDF

A systematic approach for the development of porous concrete based on axiomatic design theory

  • Tran, X.H.;Tawie, R.;Lee, H.K.
    • Computers and Concrete
    • /
    • v.6 no.6
    • /
    • pp.491-503
    • /
    • 2009
  • This paper presents a design framework developed using axiomatic design (AD) theory that can be applied in the design process of porous concrete. The main contribution of this paper is the definition of an AD framework based on the needs and functional requirements of porous concrete. The framework shows how AD theory can be used to provide guidelines for proportioning and manufacturing porous concrete. The advantage of the AD approach is that it systemizes the way to decouple design parameters and makes designers to think rationally between what we want to achieve and how we propose to satisfy the functional requirements of porous concrete. In this paper, test results of laboratory-size porous concrete specimens under compression were analyzed to evaluate the performance of the porous concrete based on the desired functional requirements.

Application Research on Mechanical Strength and Durability of Porous Basalt Concrete

  • Zhu, Yuelei;Li, Jingchun;Zhu, He;Jin, Long;Ren, Qifang;Ding, Yi;Li, Jinpeng;Sun, Qiqi;Wu, Zilong;Ma, Rui;Oh, Won-Chun
    • Korean Journal of Materials Research
    • /
    • v.32 no.3
    • /
    • pp.115-124
    • /
    • 2022
  • Porous basalt aggregate is commonly used in roadbed engineering, but its application in concrete has rarely been studied. This paper studies the application of porous basalt in concrete. Porous basalt aggregate is assessed for its effects on mechanical strength and durability of prepared C50 concrete; because it has a hole structure, porous basalt aggregate is known for its porosity, and porous basalt aggregates can be made full of water through changing the content of saturated basalt; after full-water condition is achieved in porous basalt aggregate mixture of C50 concrete, we discuss its mechanical properties and durability. The effects of C50 concrete prepared with basalt aggregate on the compressive strength, water absorption, and electric flux of concrete specimens of different ages were studied through experiments, and the effects of different replacement rates of saturated porous basalt aggregate on the properties of concrete were also studied. The results show that porous basalt aggregate can be prepared as C50 concrete. For early saturated porous basalt aggregate concrete, its compressive strength decreases with the increase of the replacement rate of saturated aggregate; this occurs up to concrete curing at 28 d, when the replacement rate of saturated basalt aggregate is greater than or equal to 40 %. The compressive strength of concrete increases with the increase of the replacement rate of saturated aggregate. The 28 d electric flux decreases with the increase of the replacement rate of saturated aggregate, indicating that saturated porous basalt aggregate can improve the chloride ion permeability resistance of concrete in later stages.

An Experimental Study on the Quality Control of Fresh Porous Concrete (굳지않은 포러스콘크리트의 품질관리를 위한 실험적 연구)

  • 이성일;장종호;김재환;강석표;백용관;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.705-710
    • /
    • 2002
  • Recently, there has been for a number of reasons growing interest in the use of porous concrete, and it is used as an ecological material. But, because the valuation methods of the quality on the fresh porous concrete aren't established up till now, it is difficult that the harden porous concrete is made sure of its required quality. This study is to present the measurement method of the void ratio on the fresh porous concrete and to analyze the influence of water-cement ratio and vibrating time on the binder content covered a coarse aggregate. Results of this study were shown as follows; The measurement methods of the void ratio and aggregate-binder weight ratio on the fresh porous concrete can be useful as data for the quality control of fresh porous concrete.

  • PDF

Fundamental Properties of Porous Concrete by Aggregate Size

  • Kim, Moo-Han;Kim, Gyu-Yong;Baik, Yong-Kwan;Kim, Jae-Hwan;Cho, Bong-Suk
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.2E
    • /
    • pp.117-124
    • /
    • 2006
  • Porous concrete has been used recently for the purpose of decreasing the load on the earth environment. It consists solely of cement, water and coarse aggregate of uni form size. Its fundamental properties are considerably affected by the physical properties of aggregate because the aggregate is the main material for the most part in its mix proportion. Because of this reason, this study carried out an investigation of the influence of the size and type of aggregate on the fundamental properties of porous concrete. It is shown that the fundamental properties of porous concrete was seldom affected by the size of aggregate except for the case of using $2.5{\sim}5mm$ aggregate but varied significantly by the type of aggregate. In particular, the compressive strength of porous concrete using $2.5{\sim}5mm$ aggregate was much higher than that using other aggregate, and its void ratio and coefficient of permeability was lower. Moreover, the capacity to maintain the permeability of porous concrete was found to vary by the size and type of aggregate. Of particular notice was that it decreased greatly when $2.5{\sim}5mm$ aggregate was used. Unlike ordinary concrete, porous concrete exhibited very high dynamic modulus of elasticity at early age and continued to increase but slowly afterwards.

Void Ratio and Strength of Porous Polymer Concrete and Initial Growth Properties within Planting Block with Binder Contents (결합재량에 따른 포러스 폴리머 콘크리트의 공극률과 강도 및 식생 블록 내 초기 생장 특성)

  • Sung, Chan-Yong;Kim, Young-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.6
    • /
    • pp.101-110
    • /
    • 2010
  • This study was performed to evaluate the void ratio and strength of porous polymer concrete used coarse aggregates and unsaturated polyester resin to find optimum mix design of porous polymer concrete for planting block. Also, this study was performed to evaluate the planting properties of herbaceous plant and cool-season grass in porous polymer blocks based on the experimental results of porous polymer concrete to develop environmentally friendly planting blocks. Tests for the void ratio and compressive strength of porous polymer concrete were performed at the curing age 7 days. Also, kinds of plants such as Tall fescue, Perennial ryegrass, Lespedeza and Alfalfa for planting were applied to porous polymer blocks. Within 6 weeks after seed, initial germination ratio, cover view and growth length for planting blocks were estimated by various methods.

Frost resistance of porous concrete assuming actual environment (實環境を考慮したポーラスコンクリートの耐凍害性の評価(실제 환경을 고려한 다공질 콘크리트의 내동해성(耐凍害性) 평가))

  • NAKAMURA, Takuro;HORIGUCHI, Takashi;SHIMURA, Kazunori;SUGAWARA, Takashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.227-233
    • /
    • 2008
  • Porous concrete has large continuous voids of 20-30 % by volume, and this concrete is attractive as environmental material in Japan i.e. permeable road pavement, river bank protection with vegetation and green roof system which influence thermal environment. It is necessary to confirm the frost resistance when constructing porous concrete structure in cold region. However applicable test method and evaluation criterion of porous concrete has not defined yet. Therefore, the object of this study is to investigate the frost resistance of porous concrete and this investigation attempts to address this concern by comparing 4 kinds of specified freezing and thawing tests methods (JIS A1148 procedure A/B and RILEM CIF/CDF test) in consideration of actual environment. RILEM freeze-thaw tests are different from JIS A1148 freeze-thaw tests, which are widely adopted for evaluating the frost resistance of conventional concrete in Japan, in water absorption, cooling rate, length of freezing and thawing period, and number of freezing and thawing cycles. RILEM CIF test measures internal damage and is primarily applicable for pure frost attack. CDF test is appropriate for freeze-thaw and de-icing salt attack. JIS A1148 procedure A/B showed extremely low frost resistance of porous concrete if the large continuous voids were filled with water and the ice expansion in the large continuous voids set in during cooling. Frost resistance of porous concrete was improved by mixing coarse aggregate (G7) which particle size is smaller and fine aggregate in JIS freezing and thawing tests. RILEM CIF/CDF test showed that freeze-thaw and de-icing resistance of porous concrete was seems to be superior in that of conventional concrete.

  • PDF

An Experimental Study on the Characteristic of Porous Concrete using different Aggregates (골재의 종류에 따른 포러스콘크리트의 특성에 관한 실험적 연구)

  • Jung, Si-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.89-96
    • /
    • 2004
  • Porous concrete is used of various parts by advantage of porous. Example of growing of plant is possible, and dwelling of creature, and filter functions of various contaminant, and decrease of noise, and so on. This research is for porous concretes that were used by four aggregate rubble, refreshing aggregate, expanded clay, orchid stone. This research estimate that physical and mechanical characteristics of fresh concrete and hardened concrete. The purpose of this research is to make environment-friendly porous concrete. This research's conclusion is as following : 1. Porous Concrete's slump was measured 12~14cm with rubble, 12~16cm with refreshing aggregate, 11~13cm with expanded clay, 11~13cm with orchid stone. Weight of aggregate was bigger, slump price appeared by bigger thing. Because placed Porous Concrete is low viscosity and small resistance between aggregate, it estimated that have high workability. 2. Porous Concrete's unit weight was measured 1.71~1.75t/$\textrm{m}^3$ with rubble, 1.58~1.62t/$\textrm{m}^3$ with refreshing aggregate, 1.19~1.20t/$\textrm{m}^3$ with expanded clay, 0.98~1.06t/$\textrm{m}^3$ with orchid stone. Showed aspect such as weight of aggregate. 3. Porous Concrete's compressive strength was measured 76~102kgf/$\textrm{cm}^2$ with rubble, 51~60kgf/$\textrm{cm}^2$ with refreshing aggregate, 30~40kgf/$\textrm{cm}^2$ with expanded clay, 13~16kgf/$\textrm{cm}^2$ with orchid stone. 4. Tendency of tensile strength and bending strength showed generally similarly with compressive strength, but showed low value fewer than 15kgf/$\textrm{cm}^2$ Therefore, wire mesh, reinforcing rod, such as establishment of frame is considered to need in reinforcement about tensility or flexures in case receive tensility or produce product of thin absence form. It concludes by speculating on the consequences of extrapolating the results of study to remodelling the office building being already existence.

Heavy Metal Leaching, CO2 Uptake and Mechanical Characteristics of Carbonated Porous Concrete with Alkali-Activated Slag and Bottom Ash

  • Kim, G.M.;Jang, J.G.;Naeem, Faizan;Lee, H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.3
    • /
    • pp.283-294
    • /
    • 2015
  • In the present study, a porous concrete with alkali activated slag (AAS) and coal bottom ash was developed and the effect of carbonation on the physical property, microstructural characteristic, and heavy metal leaching behavior of the porous concrete were investigated. Independent variables, such as the type of the alkali activator and binder, the amount of paste, and $CO_2$ concentration, were considered. The experimental test results showed that the measured void ratio and compressive strength of the carbonated porous concrete exceeded minimum level stated in ACI 522 for general porous concrete. A new quantitative TG analysis for evaluating $CO_2$ uptake in AAS was proposed, and the result showed that the $CO_2$ uptake in AAS paste was approximately twice as high as that in OPC paste. The leached concentrations of heavy metals from carbonated porous concrete were below the relevant environmental criteria.