• Title/Summary/Keyword: micro viscosity

Search Result 179, Processing Time 0.032 seconds

Prediction of Viscosity in Liquid Epoxy Resin Mixed with Micro/Nano Hybrid Silica (액상 에폭시 수지와 마이크로/나노 하이브리드 실리카 혼합물의 점도 예측)

  • Huang, Guang-Chun;Lee, Chung-Hee;Lee, Jong-Keun
    • Korean Journal of Materials Research
    • /
    • v.21 no.2
    • /
    • pp.100-105
    • /
    • 2011
  • The relative viscosity was measured at different filler loadings for a cycloaliphatic epoxy resin and hexahydro-4-methylphthalic anhydride hardener system filled with micro/nano hybrid silica. Various empirical models were fitted to the experimental data and a fitting parameter such as critical filler fractions (${\phi}_{max}$) was estimated. Among the models, the Zhang-Evans model gave the best fit to the viscosity data. For all the silica loadings used, ln (relative viscosity) varied linearly with filler loadings. Using the Zhang-Evans model and the linearity characteristics of the viscosity change, simple methods to predict the relative viscosity below ${\phi}_{max}$ are presented in this work. The predicted viscosity values from the two methods at hybrid silica fractions of $\phi$ = 0.086 and 0.1506 were confirmed for a micro:nano = 1:1 hybrid filler. As a result, the difference between measured and predicted values was less than 11%, indicating that the proposed predicting methods are in good agreement with the experiment.

Microfluidic Method for Measurement of Blood Viscosity based on Micro PIV (Micro PIV 를 기반한 혈액 점도 측정 기법)

  • Hong, Hyeonji;Jung, Mirim;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.3
    • /
    • pp.14-19
    • /
    • 2017
  • Increase of blood viscosity significantly changes the flow resistance and wall shear stress which are related with cardiovascular diseases. For measurement of blood viscosity, microfluidic method has proposed by monitoring pressure between sample and reference flows in the downstream of a microchannel with two inlets. However, it is difficult to apply this method to unknown flow conditions. To measure blood viscosity under unknown flow conditions, a microfluidic method based on micro particle image velocimetry(PIV) is proposed in this study. Flow rate in the microchannel was estimated by assuming velocity profiles represent mean value along channel depth. To demonstrate the measurement accuracy of flow rate, the flow rates measured at the upstream and downstream of a T-shaped microchannel were compared with injection flow rate. The present results indicate that blood viscosity could be reasonably estimated according to shear rate by measuring the interfacial width and flow rate of blood flow. This method would be useful for understanding the effects of hemorheological features on the cardiovascular diseases.

A Study on Selecting Conditions of Rapid Prototype for Controls of Shape of Micro-hole (미세홀 형상제어를 위한 쾌속조형의 조건선정에 관한 연구)

  • Kim T.H.;Park J.D.;Lee S.S.;Seo S.H.;Jeon E.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.738-742
    • /
    • 2005
  • Rapid Prototype has been used to design and Production of part in a variety of fields ; Car, Electronic products, Aviation, Heavy industry etc. Moreover development of hardware gave rise to use the method of Rapid Prototype more and more at high precision and complicated shapes. Expecially, to be using process of products that shapes of Micro-hole ; Cellular phones, Antennas, Jewels, Semi conductor cases. In case of Micro-shape, precision of the shape turns on various condition ; Laser size, Laminate height, scanning speed, overcure, viscosity of resin, etc. Sometimes breaks out the case that interner hole of shape is blocked by viscosity of resin. The phenomenon has solved easily to reduce viscosity of resin. But, in case of the method brings about the problem that strength goes down in actuality products hardening. This study on verify to change of shape of Micro-hole and makes the semiconductor case which has shape of Micro-hole by using resin of higher viscosity, scanning speed and overcure

  • PDF

SELF-ADHESION OF LOW-VISCOSITY COMPOSITES TO DENTIN SURFACE (상아질에 대한 저점도 복합레진의 자가접착에 관한 연구)

  • Cho, Tae-Hee;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.3
    • /
    • pp.209-221
    • /
    • 2003
  • The objectiveness of this study was to evaluate whether low-viscosity composite can bond effectively to dentin surface without bonding resin. The low-viscosity composites being 50wt% filler content were made by the inclusion of bonding resin of two self-etching systems(Cleafil SE Bond, Unifil Bond) varied with contents as 0, 10, 20, 30, 40, 50wt%. Exposed dentin surfaces of extracted 3rd molars are used. Dentin bond strengths were measured. The tests were carried out with a micro-shear device placed testing machine at a CHS of 1mm/min after a low-viscosity composite was filled into an iris cut from micro tygon tubing with internal diameter approximately 0.8mm and height of 1.0mm. 1 Flexural strength and modulus was increased with the addition of bonding resin. 2. Micro-shear bond strength to dentin was improved according to content of bonding resin irrespective of applying or not bonding resin in bonding procedure, and that of Clearfil SE Bond groups was higher than Unifil Bond. 3. There were no significant difference whether use of each bonding resin in bonding procedure for S-40, S-50, U-50(p>0.05). 4. In SEM examination, resin was well infiltrated into dentin after primed with self-etching primer only for S-50 and U-50 in spite of the formation of thinner hybrid layer. Low viscosity composite including some functional monomer may be used as dentin bonding resin without an intermediary bonding agent. It makes a simplified bonding procedure and foresees the possibility of self-adhesive restorative material.

Effects of Vortex Viscosity Variation on the Flowfields in a Micro-slot between Rotating Surfaces of Revolution (와점성 변화가 회전곡면으로 이루어진 마이크로 슬롯 유동장에 미치는 영향)

  • Choi, G.W.;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.591-596
    • /
    • 2001
  • Micron-size mechanical devices are becoming more prevalent, both in commercial applications and in scientific inquiry. Within the last decade, a dramatic increase in research activities has taken place, mostly due to the rapidly expanding growth of applications in areas of MEMS(Micro-Electro-Mechanical Systems), bioengineering, chemical systems, and advanced energy systems. In this study, we have described the effects of vortex viscosity variation on the flowfields in a micro-slot between rotating surfaces of revolution using a micropolar fluid theory. In order to solve this problem, we have used boundary layer equations and applied non-zero values of the microrotation vector on the wall. The results are compared with the corresponding flow problems for Newtonian fluid. Results show that the coefficient $\delta$ controls the main part of velocity ${\upsilon}_x$ and the coefficient M controls the main part of microrotation component ${\Omega}_{\theta}$.

  • PDF

In-vitro Study on Hemorheological Behaviors of Blood Flow Through a Micro Tube (미세튜브 내부를 흐르는 혈액유동의 유변학적 특성에 대한 in-vitro 연구)

  • Kang, Myung-Jin;Ji, Ho-Seong
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.99-105
    • /
    • 2010
  • In order to obtain velocity profile of blood flow with high spatial resolution, a micro PIV technique consisted of a fluorescent microscope, double-pulsed YAG laser, cooled CCD camera was applied to in-vitro blood flow experiment through a micro round tube of a diameter $100{\mu}m$. Velocity distributions of blood flow for rabbit were obtained. The viscosity profiles for shear rate were found at flowing condition. To provide hemorheological characteristics of blood flow, the viscosities for shear rate were evaluated. The viscosity of blood also steeply increase by decreasing shear rate resulting in Non-Newtonian flow, especially in low shear rate region caused by RBC rheological properties. The results show typical characteristics of Non-Newtonian characteristics from the results of velocity profile and viscosity for blood flow. From the inflection points, cell free layer and two-phase flow consisted with plasma and suspensions including RBCs can be separated.

A research about micro size polymer bead injecting process based on electrostatic force (정전기력 기반의 마이크로 사이즈 폴리머 비드 주입 공정 연구)

  • Yang, Bong-Su;Yang, Sung-Wook;Ko, Jung-Bum;Choi, Kyung-Hyun;Doh, Yang-Hoi
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.43-50
    • /
    • 2016
  • This research proposal is based on a novel non-contact technique of micro-sized bead injection process for fabrication of electronic paper display. This non-contact injection process is based on the principle of electrostatic force and uses micro-sized metal-coated beads dispersed in a solution. The dispersion retention times of three different solutions with viscosities of 10 cps, 100 cps, and 1000 cps were measured by optical equipment showing the retention times of 5 mins, 10 mins, and 30 mins respectively. The dispersion retention rate dropped as the time passed. The dispersion retention characteristic of 1000 cps solution was more stable as compared to those of 10 cps and 100 cps meaning that higher viscosity has better retention properties. The experimental results of bead injection at different viscosity levels of the solution were also measured and a stable injection result was achieved by using 1000 cps solution. This results show that stable injection is dependent on solution viscosity and dispersion.

Effect of hematocrit on hemorheological characteristics of blood flow in a microtube (헤마토크릿에 따른 혈액의 유변학적 특성 변화)

  • Ji, Ho-Seong;Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.111-112
    • /
    • 2006
  • In order to investigate flow characteristics of blood flow in a micro tube ($100{\mu}m$ in diameter) according to hematocrit, in-vitro experiments were carried out using a micro-PIV technique. The micro-PIV system consists of a microscope, a 2 head Nd:YAG laser, a 12 bit cooled CCD camera and a delay generator. Blood was supplied into the micro tube using a syringe pump. Hematocrit of blood was controlled to be 20%, 30% and 40%. The blood flow has a cell free layer near the tube wall and its thickness was changed with increasing the flow rate and hematocrit. The hemorheological characteristics such as shear rate and viscosity were evaluated using the velocity field data measured. As the flow rate increased, the blunt velocity profile in the tube center was sharpened. The viscosity of blood was rapidly increased with decreasing shear rate, especially in the region of low shear rate, changing RBC rheological properties. The variation of velocity profile and blood viscosity shows typical characteristics of Non-Newtonian fluids. On the basis of inflection points, the cell free layer and two-phase flow consisting of plasma and suspensions including RBCs were clearly discriminated.

  • PDF

Development of Micro-flowmeter for Supplying Photo-resist (포토레지스트 공급용 미소유량계 개발)

  • Kim, Shin-Ho;Cheong, Seon-Hwan;Choi, Seong-Dae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.198-204
    • /
    • 2007
  • This study was carried out to develope a flow control system using to supply PR(photo-resist) in the semi-conductor manufacturing process. The features of this system are to be able to measure the high viscosity and micro-flow. To meet above study object some ideas was induced to design a new concept valve with new material, multi-cross wheel, and new sealing method etc.. As the evaluations on the developed micro-flowmeter it was enough satisfied to use at the IT industries such as photo-resist process.