• Title/Summary/Keyword: micro device

Search Result 998, Processing Time 0.029 seconds

Development of Micro Mixing Device with Using Ultrasonic Wave (초음파를 이용한 마이크로 혼합기 제작)

  • Jeon, Yongho;Choi, Byung-Joo;Kang, Seung-Joon;Kim, Dong-Kwon;Kim, Hyun-Jung;Lee, Moon Gu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.459-464
    • /
    • 2013
  • The purpose of a micro-mixing device is to enhance the mixing by increasing the diffusion effect between different types of flows. There have been many attempts to actively or passively increase mixing. However, those studies were limited to lab-scale experiments because the production of devices requires a series of processes, time, cost, and the mixing quality itself. For this reason, this study attempted to develop a quick and simple process for micro-mixing device fabrication by using conventional machining and bonding processes and applying ultrasonic waves from the outside of the mixing device. The mixing quality was quantified by using the mixing index, and the results showed that the proposed system increases the mixing from ~33% to ~10% with respect to the flow rates.

Character Analysis of Micro Fuse Fusing as a function of De-Rating technique (디레이팅 기법에 의한 마이크로 퓨즈 용단의 특성 분석)

  • Kim, Do-Kyeong;Kim, Jong-Sick
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.8-13
    • /
    • 2015
  • Recently, Illumination industry of LED module has been focused to industry technology for energy conservation of nation. The LED device is excellent to power efficiency due to semiconductor light source element. And the application to the lighting circuit technology can be designed to the sensitive lighting system for human sensitivity control. In this paper, as a process for analyzing the operating temperature of standardized electronic device including LED device has analyzed about fusing character with in designed micro fuse for electronic device protection from the over current. Using the de-rating technique, which is performed to micro fuse fusing test in the range of $-30^{\circ}C{\sim}120^{\circ}C$ thermostatic chamber. To the output data in each temperature zone, it is performed to first-order linear fitting. Additionally, applying the resistance temperature coefficient and statistical data for the reliable analysis has derived to the metal element resistance of micro fuse with temperature change of the thermostatic chamber. As a research result, The changed temperature effect of thermostatic chamber was confirmed regarding fusing time change.

Enhancement of heat exchange using On-chip engineered heat sinks

  • Chong, Yonuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.4
    • /
    • pp.18-21
    • /
    • 2017
  • We report a method for improving heat exchange between cryo-cooled large-power-dissipation devices and liquid cryogen. Micro-machined monolithic heat sinks were fabricated on a high integration density superconducting Josephson device, and studied for their effect on cooling the device. The monolithic heat sink showed a significant enhancement of cooling capability, which markedly improved the device operation under large dc- and microwave power dissipation. The detailed mechanism of the enhancement still needs further modeling and experiments in order to optimize the design of the heat sink.

A Study on the Efficiency Effects of Capping Layer on the Top Emission Organic Light Emitting Diode (전면 유기발광 다이오드 기능층 캐핑레이어 적용에 따른 효율상승에 관한 연구)

  • Lee, DongWoon;Cho, Eou Sik;Jeon, Yongmin;Kwon, Sang Jik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.119-124
    • /
    • 2022
  • Top emission organic light-emitting diode (TEOLED) is commonly used because of high efficiency and good color purity than bottom - emission organic light-emitting device (BEOLED). Unlike BEOLED, TEOLED contain semitransparent metal cathode and capping layer. Because there are many characteristics to consider just simple thickness change, optimizing organic thickness of TEOLED for microcavity is difficult. So, in this study, we optimized Device capping layer at unoptimized micro-cavity structure TEOLED device. And we compare only capping layer with unoptimized microcavity structure can overcome optimized micro-cavity structure device. We used previous our optimized micro-cavity structure to compare each other. As a result, it has been found that the efficiency can be obtained almost the same or higher only capping layer, which is stacked on top of the device and controls only the thickness and refractive index, without complicated structural calculations. This means that higher efficiencies can be obtained more easily in laboratories with limited organic materials or when optimizing new structures etc.

Effect of Groove and Channel Size on the Thermal Transport Capacity of Micro-Capillary Pumped Loop for Mobile Electronic Device Cooling System (모바일 전자장비 냉각용 Micro-CPL내 형상크기변화에 따른 열성능 해석)

  • Kim, Byeong-Gi;Seo, Jeong-Se;Hwang, Geon;Mun, Seok-Hwan;Bae, Chan-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.329-334
    • /
    • 2005
  • As more high power wide band gap devices are being utilized. the thermal management issues associated with these devices need to be resolved. High power small devices dissipate excessive heat that must be cooled, but traditional cooling methods are insufficient to provide such a cooling means. This paper will evaluate a micro-capillary pumped loop thermal management system that is incorporated into the shim of the device, taking advantage of phase-change to increase the thermal conductivity of the system. The results of the modeling of the thermal management system will be discussed.

  • PDF

Development of Scent Display Device using Micro-pore Piezo Actuator (마이크로 다공성 압전 진동자를 이용한 발향장치 설계)

  • Lee, Young-Joon;Lim, Seung-Ju;Kim, Min-Ku;Lee, Hae-Lyong;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.399-405
    • /
    • 2016
  • Scent diffuser using micro-pore piezo actuator achieved a commercial success because of its cheap production cost, but it is easy to be use for IT-based contents due to difficulty of scent intensity control. To solve this problem, we control the emission amount of scent diffuser by changing amplitude and frequency of input voltage applied to micro-pore piezo actuator. And, we analyzed the effect of density of cotton core on emission amount and a relationship between hole-size of mesh in piezo actuator and viscosity of scents to design a mechanically optimal scent device.

Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channeland GMR-SV Device (마이크로 코일-채널과 GMR-SV 소자를 이용한 적혈구-자성비드 검출 특성연구)

  • Park, Ji-Soo;Kim, Nu-Ri;Jung, Hyun-Jun;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • The micro device, coil, and channel for the biosensor integrated with the GMR-SV device based on the antiferromagnetic IrMn layer was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ passed on the micro channel, the movement of $RBC+{\mu}Beads$ is controlled by the electrical AC input signal. The $RBC+{\mu}Beads$ having a micro-magnetic field captured above the GMR-SV device is changed as the output signals for detection status. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property as the membrane's deformation of RBC coupled to magnetic beads.

Study of sand blaster dry etched glass wafer surface for micro device package (샌드 블러스터로 건식 식각한 마이크로 소자 패키지용 유리 웨이퍼의 표면 연구)

  • Kim, Jong-Seok;Nam, Kwang-Woo;Choa, Sung-Hoon;Kwon, Jae-Hong;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.245-250
    • /
    • 2006
  • In this paper, glass cap wafer for MEMS device package is fabricated by using sand blaster dry etcher and Its surface is studied. The surface of dry etched glass is analyzed by using SEM, and many glass particles and micro cracks are observed. If these kind of particles were dropped from glass to the surface of device, It would make critical failure to the operation of device. So, several cleaning and etching methods are induced to remove these kinds of dormant failure mode and optimized condition is found out.

A Study on the Fixation Characteristics of a Self-expansion Type ACL Fixation Device (자가 확장형 전방십자인대 고정장치의 고정 특성에 대한 연구)

  • Kim, Jong-Dae;Kim, Hong-Gun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.321-327
    • /
    • 2009
  • This paper studied the influences of the main design parameter-the expansion angle and the material properties of the self-expansion anterior cruciate ligament fixation device on the contact condition with the bone and the initial stability of the device. Using finite element analysis, the stress distributions of the ring part of the device and the wall of the bone tunnel were calculated. And the micro-migration of the device by the pull-out force was calculated. From the analysis results, it was found that when designing the self-expansion type anterior cruciate ligament fixation device, it is desirable to use the material having higher Young's modulus and to design the fixation device that all wedges uniformly maintain contact with bone to obtain initial stability after operation.

  • PDF