• Title/Summary/Keyword: matrix-assisted laser desorption - time of flight mass spectrometry (MALDI-TOF MS)

Search Result 84, Processing Time 0.032 seconds

Identification of Salmonella spp. from porcine salmonellosis by matrix-assisted laser desorption ionization-time of flight mass spectrometry

  • Yang, Hyoung-Seok;Kim, Jae-Hoon
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.2
    • /
    • pp.105-110
    • /
    • 2018
  • A total of 41 Salmonella (S.) strains were isolated from pigs suffered with severe watery diarrhea and were tried to identify by both matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and polymerase chain reaction (PCR) analysis. Fibrinous exudate and ulceration in the large intestine were prevalent in gross observation, and variable degrees of enteritis were observed in the histology of large intestines. Subsequent polymerase chain reaction (PCR) analyses demonstrated that 41 strains were identified as S. Typhimurium (39 strains), though 2 stains were failed to identify. Further identification was performed using both direct smear and protein extraction method by MALDI-TOF MS analyses. In terms of extraction methods, 100% (41/41) of isolates were identified to species level of S. spp. Whereas only 43.9% (18/41) were identified to species level using the direct method. These results thus suggest that rapid and accurate diagnosis of porcine salmonellosis can be guaranteed by MALDI-TOF MS combined with protein extraction method.

Optimization in Detecting Multiply-charged Protein Ions using MALDI TOF-MS

  • Lee, Jihyeon;Hong, Jangmi;Kim, Taehee;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • v.4 no.1
    • /
    • pp.21-23
    • /
    • 2013
  • The effects of trifluoroacetic acid (TFA) were evaluated on the generation of multiply charged ions of cytochrome c in a 2-nitrophloroglucinol (2-NPG) matrix in high-vacuum, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The presence of 1% TFA in the 2-NPG matrix solution was more effective in generating multiply charged protein ions than matrix solutions containing 0.1% or 0% TFA. Regarding the matrix itself, with 1% TFA, 2-NPG was significantly more effective in generating multiply charged ions than 2,5-dihydroxybenzoic acid (2,5-DHB). The maximum charge state of cytochrome c was +8 when using a 2-NPG matrix containing 1% TFA.

Discrimination of Bacillus anthracis Spores by Direct in-situ Analysis of Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight Mass Spectrometry

  • Jeong, Young-Su;Lee, Jonghee;Kim, Seong-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2635-2639
    • /
    • 2013
  • The rapid and accurate identification of biological agents is a critical step in the case of bio-terror and biological warfare attacks. Recently, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has been widely used for the identification of microorganisms. In this study, we describe a method for the rapid and accurate discrimination of Bacillus anthracis spores using MALDI-TOF MS. Our direct in-situ analysis of MALDI-TOF MS does not involve subsequent high-resolution mass analyses and sample preparation steps. This method allowed the detection of species-specific biomarkers from each Bacillus spores. Especially, B. anthracis spores had specific biomarker peaks at 2503, 3089, 3376, 6684, 6698, 6753, and 6840 m/z. Cluster and PCA analyses of the mass spectra of Bacillus spores revealed distinctively separated clusters and within-groups similarity. Therefore, we believe that this method is effective in the real-time identification of biological warfare agents such as B. anthracis as well as other microorganisms in the field.

Applications of MALDI-TOF Mass Spectrometry in Clinical Microbiology

  • Shin, Kyeong Seob;Yum, Jonghwa
    • Biomedical Science Letters
    • /
    • v.28 no.3
    • /
    • pp.145-156
    • /
    • 2022
  • Over the past few decades, few technologies have had a greater impact on clinical microbiology laboratories than matrix-assisted laser desorption time-of-flight mass spectrometry (MALDI-TOF MS). The MALDI-TOF MS is a fast, accurate, and low-cost and efficient method of microbial identification. This technology generates characteristic mass spectral fingerprints that is a unique signature for each microorganism, making it an ideal method for accurate identification at the genus and species levels of both bacterial and fastidious microorganism such as anaerobes, mycobacterium and fungi etc. In addition, MALDI-TOF MS has been successfully used in microbial subtyping and susceptibility tests such as determination of resistance genes. In this study, the authors summarized the application of MALDI-TOF MS in clinical microbiology and clinical research and explored the future of MALDI-TOF MS.

Development of a Matrix-prespotted Plate for Enhancing the Reproducibility of Serum Glycan Analysis by MALDI-TOF-MS

  • Ha, Mi-Young;In, Young-Ha;Maeng, Hye-Sun;Zee, Ok-Pyo;Lee, Jong-Sik;Kim, Yang-Sun
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.61-64
    • /
    • 2011
  • Matrix Assisted Laser Desorption/Ionization-Time-of-Flight mass spectrometry (MALDI-TOF-MS) is the most widely used MS technique for glycan analysis. However, the poor point-to-point and sample-to-sample reproducibility becomes a limit in glycan biomarker research. A prespotted MALDI plate which overcomes the large crystal formation of 2,5-dihydroxybenzoic acid (DHB) has been developed and applied for glycan analysis. A homogeneous matrix coated surface without a crystal structure was formed on a hydrophilic/ hydrophobic patterned surface using a piezoelectric device. The reproducible MALDI-TOF-MS data have been presented using MALDI imaging of beer glycan as well as serum glycan eluted from 10% and 20% ACN elution fractions. The glycan profile from the serum glycan by MALDI-TOF-MS with a DHB prespotted plate was highly conserved for 10 different spectra and the coefficient of variations of significant ion peaks of MALDI data varies from 3.59 to 19.95.

Rapid Identification of Staphylococcus Species Isolated from Food Samples by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

  • Kim, Eiseul;Kim, Hyun-Joong;Yang, Seung-Min;Kim, Chang-Gyeom;Choo, Dong-Won;Kim, Hae-Yeong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.4
    • /
    • pp.548-557
    • /
    • 2019
  • Staphylococcus species have a ubiquitous habitat in a wide range of foods, thus the ability to identify staphylococci at the species level is critical in the food industry. In this study, we performed rapid identification of Staphylococcus species using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight mass spectrometry (MALDI-TOF MS). MALDI-TOF MS was evaluated for the identification of Staphylococcus reference strains (n = 19) and isolates (n = 96) from various foods with consideration for the impact of sample preparation methods and incubation period. Additionally, the spectra of isolated Staphylococcus strains were analyzed using principal component analysis (PCA) and a main spectra profile (MSP)-based dendrogram. MALDI-TOF MS accurately identified Staphylococcus reference strains and isolated strains: the highest performance was by the EX method (83.3~89.5% accuracy) at species level identification (EDT, 70.3~78.9% accuracy; DT, less than 46.3~63.2% accuracy) of 24-h cultured colonies. Identification results at the genus level were 100% accurate at EDT, EX sample preparation and 24-h incubation time. On the other hand, the DT method showed relatively low identification accuracy in all extraction methods and incubation times. The analyzed spectra and MSP-based dendrogram showed that the isolated Staphylococcus strains were characterized at the species level. The performance analysis of MALDI-TOF MS shows the method has the potential ability to discriminate between Staphylococcus species from foods in Korea. This study provides valuable information that MALDI-TOF MS can be applied to monitor microbial populations and pathogenic bacteria in the food industry thereby contributing to food safety.

Enrichment of Peptides using Novel C8-functionalized Magnetic Nanoparticles for Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometric Analysis

  • Song, Sun-Mi;Yang, Hyo-Jik;Kim, Jin-Hee;Shin, Seong-Jae;Park, Eun-Hye;Kim, Jeong-Kwon
    • Mass Spectrometry Letters
    • /
    • v.2 no.2
    • /
    • pp.53-56
    • /
    • 2011
  • [ $C_8$ ]functionalized magnetic nanoparticles were synthesized by coating magnetic $Fe_3O_4$ nanoparticles with silicaamine groups using 3-aminopropyltriethoxysilane and by subsequently modifying the amine groups with chloro(dimethyl)octylsilane to produce octyl groups on the surface of the MNPs. The $C_8$-functionalized MNPs were used to enrich peptides from tryptic protein digests of myoglobin and ${\alpha}$-casein. The enriched peptides were analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). MALDI-MS was also used to investigate desalting of the $C_8$-functionalized MNPs. Sample solutions were prepared in 1.0 M NaCl, and the successful removal of salt was observed. Enrichment with $C_8$-functionalized MNPs was very effective for separating and concentrating tryptic peptides.

MALDI TOF MS for the identification of Salmonella spp. from swine (돼지유래 Salmonella속 균의 동정을 위한 MALDI TOF MS 활용)

  • Sohn, Jun Hyung;Jeon, Woo Jin;Lee, Young Mi;Kim, Seon Soo
    • Korean Journal of Veterinary Service
    • /
    • v.39 no.4
    • /
    • pp.247-251
    • /
    • 2016
  • Salmonella is one of the most common bacteria that causes heavy losses in swine industry and major causative pathogen of food poisoning in public health. Various methods for the identification of Salmonella such as Gram staining, agglutination test, enzyme-linked immunosorbent assay (ELISA), polymerase chain reaction (PCR) have been used. Several studies have demonstrated that Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI TOF) Mass Spectrometry (MS) identification is an efficient and inexpensive method for the rapid and routine identification of isolated bacteria. In this study, MALDI TOF MS could provide rapid, accurate identification of Salmonella spp. from swine compared with end point PCR and real time PCR.

Proteome Analysis of Vernalization-Treated Arabidopsis thaliana by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

  • Cho, Mi-Ran;Lee, Kyung-Hyeon;Hyun, You-Bong;Lee, Il-Ha;Kim, Hie-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.427-431
    • /
    • 2007
  • In order to gain insight into the molecular changes at the protein level in plants exposed to low temperature for a long period of time (vernalization), proteome analyses of vernalization-treated Arabidopsis thaliana have been carried out by two-dimensional gel electrophoresis followed by matrix-assisted laser desorption/ ionization time-of-flight mass spectrometry. Fourteen proteins including ATP binding/GTP binding/translation elongation factor and glycine-rich RNA-binding protein 7 (GRP7) showed differential expression in vernalization-treated Arabidopsis thaliana. GRP7 showed the most dramatic increase in expression suggesting its involvement in response to vernalization treatment.

Reliable Identification of Bacillus cereus Group Species Using Low Mass Biomarkers by MALDI-TOF MS

  • Ha, Miyoung;Jo, Hyeon-Ju;Choi, Eun-Kyeong;Kim, Yangsun;Kim, Junsung;Cho, Hyeon-Jong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.6
    • /
    • pp.887-896
    • /
    • 2019
  • Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based pathogen identification relies on the ribosomal protein spectra provided in the proprietary database. Although these mass spectra can discern various pathogens at species level, the spectra-based method still has limitations in identifying closely-related microbial species. In this study, to overcome the limits of the current MALDI-TOF MS identification method using ribosomal protein spectra, we applied MALDI-TOF MS of low-mass profiling to the identification of two genetically related Bacillus species, the food-borne pathogen Bacillus cereus, and the insect pathogen Bacillus thuringiensis. The mass spectra of small molecules from 17 type strains of two bacilli were compared to the morphological, biochemical, and genetic identification methods of pathogens. The specific mass peaks in the low-mass range (m/z 500-3,000) successfully identified various closely-related strains belonging to these two reference species. The intensity profiles of the MALDI-TOF mass spectra clearly revealed the differences between the two genetically-related species at strain level. We suggest that small molecules with low molecular weight, 714.2 and 906.5 m/z can be potential mass biomarkers used for reliable identification of B. cereus and B. thuringiensis.