• Title/Summary/Keyword: mass fraction

Search Result 1,056, Processing Time 0.039 seconds

On the origin of escape fractions of ionizing radiation from star-forming galaxies at high redshift

  • Yoo, Taehwa;Kimm, Taysun;Rosdahl, Joakim
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.73.2-73.2
    • /
    • 2019
  • The physical origin of low escape fractions of ionizing radiation derived from Lyman-break galaxies (LBGs) at z ~ 3 - 4 is a puzzle in the theory of reionization. We perform idealized disk galaxy simulations to investigate how galactic properties, such as metallicity and gas mass, affect the escape of Lyman continuum (LyC) photons using radiation-hydrodynamic code RAMSES-RT, with strong stellar feedback. We find that the luminosity-weighted escape fraction from a metal-poor (Z=0.002) galaxy embedded in a halo of mass Mh ~ 1011 M is 〈f3Desc〉 ~ 8%. However, when the gas metallicity is increased to Z=0.02, the escape fraction is significantly reduced to 〈f3Desc〉 ~ 1%, as young stars are enshrouded by their birth clouds for a longer period of time. On the other hand, increasing the gas mass by a factor of 5 leads to 〈f3Desc〉 ~ 4%, as LyC photons are only moderately absorbed by the thicker disk. Our experiments seem to suggest that high metallicity is primarily responsible for the low escape fractions observed from LBGs, supporting the scenario in which the escape fraction has a negative correlation with halo mass. Indeed, our simulated galaxy with the typical metallicity of LBGs (Z=0.006) shows the relative escape fraction of 8%, consistent with recent observations of galaxies with M1500 = -20.

  • PDF

One-Dimensional Analysis of Air-Water Two Phase Natural Circulation Flow (공기와 물의 이상 자연순환 유동의 1 차원 해석)

  • Park, Rae-Joon;Ha, Kwang-Soon;Kim, Jae-Cheol;Hong, Seong-Wan;Kim, Sang-Baik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2626-2631
    • /
    • 2007
  • Air-water two phase natural circulation flow in the T-HERMES (Thermo-Hydraulic Evaluation of Reactor cooling Mechanism by External Self-induced flow)-1D experiment has been evaluated to verify and evaluate the experimental results by using the RELAP5/MOD3 computer code. The RELAP5 results have shown that an increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not effective on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. The water level is not effective on the water circulation mass flow rate. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it is not effective on the local pressure.

  • PDF

Structural Identification of a Non-Glycosylated Variant at Ser126 for O-Glycosylation Site from EPO BRP, Human Recombinant Erythropoietin by LC/MS Analysis

  • Byeon, Jaehee;Lim, Yu-Ri;Kim, Hyong-Ha;Suh, Jung-Keun
    • Molecules and Cells
    • /
    • v.38 no.6
    • /
    • pp.496-505
    • /
    • 2015
  • A variant peak was detected in the analysis of RP-HPLC of rHu-EPO, which has about 7% relative content. Fractions of the main and the variant peaks were pooled separately and further analyzed to identify the molecular structure of the variant peak. Total mass analysis for each peak fraction using ESI-TOF MS shows differences in molecular mass. The fraction of the main peak tends to result in higher molecular masses than the fraction of the variant. The detected masses for the variant are about 600-1000 Da smaller than those for the main peak. Peptide mapping analysis for each peak fraction using Asp-N and Glu-C shows differences in O-glycopeptide profiles at Ser126. The O-glycopeptides were not detected in the fraction of the variant. It is concluded that the variant peak is non-O-glycosylated rHu-EPO and the main peak is fully O-glycosylated rHu-EPO at Ser126.

Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System (아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구)

  • Lee, Dong-Won;Kim, Jeong-Bae
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.30-35
    • /
    • 2011
  • To clarify the hydraulic and thermal characteristics of ice slurry which made from 6.5% ethylene glycol-water solution flow in the double tube and plate type heat exchanger, experimental studies were performed. The mass flux and ice fraction of ice slurry were varied from 800 to 3500 kg/$m^2s$(or 7 to 17 kg/min) and from 0 to 25%, respectively. Through the experiment, it was found that the measured pressure drop and heat transfer rate increase with the mass flux and ice fraction; however the effect of ice fraction appears not to be significant at high mass flux region. At the region of low mass flux, a sharp increase in the pressure drop and heat transfer rate were observed depends on mass flux.

Mass and Heat Transfer Characteristics of Vertical Flat Plate with Free Convection

  • Kim Myoung- Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.729-735
    • /
    • 2005
  • This paper has dealt with the characteristics of mass and heat transfer of vertical flat plate with free convection. The theory of similarity transformations applied to the momentum and energy equations for free convection. To derive the similarity equation of mass transfer. the equation for conservation of species was added to the continuity. momentum and energy equations. The momentum, energy and species equations set numerically to obtain the velocity, temperature and mass fraction of species as dimensionless. For cases where momentum transport dominates, the thermal boundary layers are shorter than the momentum boundary layer. The relationships between momentum, energy and species were clarified from this study.

Intake Valve Temperature Effect on the Mixture Preparation in a SI Engine During Warm-up

  • 신영기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.51-66
    • /
    • 1997
  • A heat transfer model of the intake valve in a spark ignition engine is presented, which is calibrated with a number of the valve temperature profiles measured during engine warm-up for the gaseous fuel(propane). The valve is divided into four identical elements for which the assumption of lumped thermal mass is applied. The calibration is made so that the difference between the measued and simulated valve temperatures becomes minimal. Then the model is applied to the cases of the liquid fuel(indolene) to estimate the amount of the liquid fuel vaporized from the intake valve by assuming that fuel evaporation accounts for the deficit of the heat balance budget. The results of the model show quantitative contribution of each heat transfer source to the heat balance. The behavior of the calculated mass fraction of the fuel vaporized from the intake valve explains how the liquid fuel evaporate during engine warm-up. The mass fraction at warmed-up condition is closely related with the fraction directly targeted on the valve back by the fuel spray geometry.

  • PDF

Numerical Analysis of Silicon Deposition in Horizontal & Vertical CVD Reactor (수평 및 수직형 CVD 증착로의 실리콘 부착에 관한 수치해석)

  • Kim, In;Baek, Byung-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.410-416
    • /
    • 2002
  • The fluid flow, heat transfer and the local mass fraction of chemical species in the chemical vapor deposition(CVD) manufacturing process are studied numerically. Flow with a dilute precursor concentration of silane in hydrogen as the carrier gas enters to the reactor and deposits silicon onto the heated surface. The silicon deposition rate using silane is calculated in the horizontal or vertical, axisymmetric reactor. The effects of inlet carrier gas velocity, mass fraction of silane, susceptor angle and rotation of surface on the deposition rate are described.

The Effect of Non-condensable Gas on Direct Contact Condensation of Steam/Air Mixture

  • Lee, Hanchoon;Kim, Moohwan;Park, Suki
    • Nuclear Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.585-595
    • /
    • 2001
  • A series of experiments have been carried out to investigate the effects of non-condensable gas on the direct contact film condensation of vapor mixture under an adiabatic wall condition. The average heat transfer coefficient of the direct contact condensation was obtained at the atmospheric pressure with four main parameters ; air-mass fraction, mixture velocity, film Reynolds number, and the degree of water film subcooling having an influence on the condensation heat transfer coefficient. With the analysis of 88 experiments, a correlation of the average Nusselt number for direct contact film condensation of steam/air mixture at an adiabatic vertical wall was proposed as functions of film Reynolds number, mixture Reynolds number, air mass fraction, and Jacob number. The average heat transfer coefficient for steam/air mixture condensation decreased significantly while air mass fraction increased. The average heat transfer coefficients also decreased as the Jacob number increased, and were scarcely affected by the film Reynolds number below a mixture Reynolds number of about 245,000.

  • PDF

Effect of Particle Characteristics and Temperature on Shear Yield Stress of Magnetorheological Fluid

  • Wu, Xiangfan;Xiao, Xingming;Tian, Zuzhi;Chen, Fei;Jian, Wang
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.244-248
    • /
    • 2016
  • Aiming to improve the shear yield stress of magnetorheological fluid, magnetorheological fluids with different particle characteristics are prepared, and the influence rules of particle mass fraction, particle size, nanoparticles content and application temperature on shear yield stress are investigated. Experimental results indicate that shear yield stress increases approximate linearly with the enhancement of particle mass fraction. Particle size and the nanoparticles within 10% mass fraction can improve the shear yield stress effectively. When the application temperature is higher than $100^{\circ}C$, the shear yield stress decreases rapidly because of thermal expansion and thermal magnetization effect.

Rhus verniciflua Stokes Extract and Its Flavonoids Protect PC-12 Cells against H2O2-Induced Cytotoxicity

  • Nam, Tae Gyu;Lee, Bong Han;Choi, Hyo-Kyoung;Mansur, Ahmad Rois;Lee, Sang Gil;Kim, Dae-Ok
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.6
    • /
    • pp.1090-1097
    • /
    • 2017
  • Rhus verniciflua Stokes (RVS), an herbal medicine found in East Asia, was extracted and further fractionated to investigate its antioxidant capacity and neuroprotective effects. The RVS ethyl acetate (EtOAc) fraction had the highest level of total phenolics and antioxidant capacity among all solvent fractions tested. Pretreatment of PC-12 cells with the EtOAc fraction effectively attenuated $H_2O_2$-induced oxidative damage. Furthermore, the EtOAc fraction significantly attenuated caspase-3 activity, resulting in inhibition of $H_2O_2$-induced apoptosis. We identified and quantified fustin, sulfuretin, and butein in the EtOAc fraction using accurate mass quadrupole time-of-flight mass spectrometry and reversed-phase high-performance liquid chromatography. The intracellular antioxidant capacity and superoxide dismutase (SOD) activity were significantly increased in PC-12 cells treated with the EtOAc fraction and with individual flavonoids. When cells were pretreated with the EtOAc fraction or individual flavonoids and then co-incubated with diethyldithiocarbamic acid (an inhibitor of SOD activity), cell viability against $H_2O_2$-induced oxidative stress was attenuated. These results suggest that the RVS EtOAc fraction and its flavonoid constituents protect PC-12 cells against $H_2O_2$-induced neurotoxicity through their antioxidant properties.