• Title/Summary/Keyword: liquid column separation

Search Result 341, Processing Time 0.026 seconds

A Study on Fluid Thansient Accommpanying Cilumn Separation in Oil Hydraulic Pipeline -Investigation on Two-Step Pressure Rise (유압 관로계에서 액주분리를 수반하는 유체과도현상에 관한 연구 -2단입력 상승현상에 관하여-)

  • 염만오;이진걸;이일영;김현기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.984-991
    • /
    • 1988
  • Liquid column separation occurs when the valve on the pipeline is closed rapidly in an oil hydraulic system. In this case two-step pressure rise is sometimes observed in a comparatively short pipeline. In this study the two-step pressure rise phenomenon was investigated experimentally and theoretically. The experiments showed that maximum pressure values during two-step pressure rise might exceed extremely the values computed by the theory of rigid-liquid-column separation. So the two-step pressure rise phenomenon appears one of important factors of pipe strength design. From the theoretical considerations based on the experimental and numerical results, the mechanism of two-step pressure rise phenomenon could be explained clearly.

Separation of Burnup Monitors in Spent Nuclear Fuel Samples by Liquid Chromatography

  • Joe, Kih-Soo;Jeon, Young-Shin;Kim, Jung-Suck;Han, Sun-Ho;Kim, Jong-Gu;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.569-574
    • /
    • 2005
  • A coupled column liquid chromatography system was applied for the separation of the burnup monitors in spent nuclear fuel sample solutions. A reversed phase column was studied for the adsorption behavior of uranyl ions using alpha-hydroxyisobutyric acid as an eluent and used for the separation of plutonium and uranium. A cation exchange column prepared by coating 1-eicosylsulfate onto the reversed phase column was used for the separation of the lanthanides. In addition, retention of Np was checked with the reversed phase column and cation exchange column, respectively, according to the oxidation states to observe the interference effect for the separation of burnup monitors. This chromatography system showed a great reduction in separation time compared to a conventional anion exchange method. A good agreement from the burnup data was obtained between for this method and a conventional anion exchange method to within 1% of a difference for the spent nuclear fuel samples of about 40 GWD/MTU.

A Hydraulic and Feasibility Study of New Tower Internal in Gas Processing Plants

  • Choo Chang-upp
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2004
  • A new tower internal, which is called CSE, is presented. The CSE is composed of a nozzle perforated in its bottom along the entire periphery and equipped with a multi vane axial swirler at the inlet and hollow cylindrical separator at the outlet of the nozzle. According to the experimental work for obtaining the necessary hydraulic information of the CSE, which is used for preliminary design of a separation column, the CSE showed a stable operation over the wide rage of gas/liquid ratio. However, it caused large pressure drop due to the high gas velocity which should carry liquid droplets through the element. The high pressure drop may cause problems in energy recovery and the application of the CSE can be limited to the high pressure columns. Assuming that the tray efficiency of the CSE is the same with the existing separation columns, the results of the column design showed the size reduction of the column diameters by 30 to $40\%$ and investment cost saving, depending on operating conditions. The application of the CSE to separation column may also contribute to the de-bottlenecking the existing column.

Chiral Purity Test of Metoprolol Enantiomer After Derivatization with (-)-Menthyl Chloroformate by Reversed-Phase High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Choi, Pok-Wha;Hong, Seon-Pyo;Kim, Hyun-Ju
    • Archives of Pharmacal Research
    • /
    • v.22 no.6
    • /
    • pp.614-618
    • /
    • 1999
  • A reversed-phase high-performace liquid chromatographic method was developed to determine the optical purity of metoprolol enantiomers. The enantiomers were converted to diastereomeric derivatives using (-)-menthyl chloroformate reagent. Separation of the enantiomers as diastereomers was achieved by reversed-phase HPLC within 30 min using Inertsil C8 column. This method allowed determination of 0.05% of either enantiomer in the presence of its stereoisomer and method validation showed adequate linearity over the required range. Owing to the reaction condition during the derivatization with (-)-menthyl chloroformate, the possibility of racemization had to be established. Different ratios of (S)-(-)-metoprolol and (R)-(+)-metoprolol were prepared. Enantiomeric separation of these mixtures took place on a chiralcel OD column or, after derivatization with (-)-menthyl chloroformate, on a C8 column. The results form the these two independent separation systems were compared with trace racemization and were in very good agreement. No racemization was found during the experiment.

  • PDF

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.

Enantiomer separation using a covalently immobilized chiral column derived from polysaccharide derivative by reversed phase liquid chromatography (역상 크로마토그래피에서 다당유도체로 공유결합된 키랄 컬럼을 이용한 거울상 이성질체의 광학분리)

  • Huang, Hu;Jin, Jing Yu;Baek, Chae-Sun;Lee, Wonjae
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.148-151
    • /
    • 2009
  • Enantiomer separation of N-fluorenylmethoxycarbonyl (FMOC) $\alpha$-amino acid was performed on covalently immobilized chiral column (Chiralpak IB) based on polysaccharide derivative as a chiral selector by reversed phase liquid chromatography. The effect of the reversed mobile phase on the chromatographic parameters of the enantioselectivities, resolution factors and retention times using covalently immobilized Chiralpak IB was shown. Also the enantiomer separation of N-FMOC $\alpha$-amino acid in the reversed and normal phase was compared and the results obtained in the former mobile phase were generally lower than those in the latter mobile phase.

Residence Time Distribution in the Chromatographic Column: Applications in the Separation Engineering of DNA

  • Park, Young G.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.2
    • /
    • pp.117-125
    • /
    • 2003
  • Experimental and theoretical works were performed for the separation of large polyelectrolyte, such as DNA, in a column packed with gel particles under the influence of an electric field. Since DNA quickly orient in the field direction through the pores, this paper presents how intraparticle convection affects the residence time distribution of DNAs in the column. The concept is further illustrated with examples from solid -liquid systems, for example, from chromatography Showing how the column efficiency is improved by the use of a n electric field. Dimensionless transient mass balance equations were derived, taking into consideration both diffusion and electrophoretic convection. The separation criteria are theoretically studied using two different Peclet numbers in the fluid and solid phases. These criteria were experimentally verified using two different DNAs via electrophoretic mobility measurements. which showed how the separation position of the DNAs varies in the column in relation to the Peg/Pef values of an individual DNA. The residence time distribution was solved by an operator theory and the characteristic method to yield the column response.

Micro-Determination of D-Amino Acids in Milk by using Column Switching System (Column-Switching System을 이용한 우유속의 D-아미노산의 미량정량)

  • Lee, Sun Haing;Kim, Kyoung Hee;Lee, Young Cheol;Kim, Sang Tae
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.257-265
    • /
    • 1995
  • Free amino acids were isolated from milk and their absolute amounts were determined by reversed phase high performance liquid chromatography after derivatization with dansyl chloride. The determination of D- and L-amino acids was based on achiral separation on a C18 column. It was found that milk contained totally 41.00 mg DL-amino acids in 100 mL milk. The level of D-amino acids to L-amino acids was determined by a column-switching system combining an achiral reversed phase separation and chiral chelate additive. The chiral separation was carried out with addition of the chiral Cu(N-benzyl-L-proline)2 chelate to the mobile phase in reversed phase liquid chromatography. It was found that the determination of 16 different amino acids is feasible in the milk sample with a C18 column separation and 12 D-amino acids out of the 16 amino acids can be determined via the column-switching system with chiral separation. 2.05% of D-glutamic acid and 2.93% of D-alanine were found in milk.

  • PDF

Simultaneous Enantiomer Separation of α-Amino Acids and Their Esters as Fluorenylmethoxycarbonyl Derivatives under UV and Fluorescence Detection by High Performance Liquid Chromatography (고성능 액체 크로마토그래피에서 아미노산과 이들 에스테르의 플루오레닐메톡시카르보닐 유도체의 자외선과 형광 검출에서의 동시 광학분리)

  • Islam, Md. Fokhrul;Lee, Wonjae
    • KSBB Journal
    • /
    • v.30 no.4
    • /
    • pp.197-201
    • /
    • 2015
  • Liquid chromatographic enantiomer separation of ${\alpha}$-amino acids and their methyl and ethyl esters as fluorenylmethoxycarbonyl (FMOC) derivatives was performed using a recently developed chiral column (Chiralpak IE) based on polysaccharide derivative under simultaneous UV detection and fluorescence detection. The degree of enantiomer separation of ${\alpha}$-amino acid esters as FMOC derivatives is generally higher than that of the corresponding ${\alpha}$-amino acids. Especially, ${\alpha}$-amino acid methyl esters showed the greatest enantioseparation. As this method developed in this study can be applied to determine the chemical and optical purity of ${\alpha}$-amino acids and esters, it is expected to be quite useful for their chiral separation using Chiralpak IE.

Separation and Purification of Lipase Inhibitory Peptide from Fermented Milk by Lactobacillus plantarum Q180

  • Kim, Seulki;Lim, Sang-Dong
    • Food Science of Animal Resources
    • /
    • v.40 no.1
    • /
    • pp.87-95
    • /
    • 2020
  • In this study, we separated and purified lipase inhibitory peptide from fermented milk by Lactobacillus plantarum Q180 with the aim of developing a new functional anti-lipase activity yogurt product. L. plantarum 180 was inoculated into 10% reconstituted skimmed milk and incubated at 37℃ until the pH of the culture reached pH 4.4. The lipase activity was measured using porcine pancreatic lipase. The lipase inhibitory peptides were gradually isolated by ultrafiltration, reversed phase column chromatography (RPC), reversed phase high-performance liquid chromatography (RP-HPLC), and gel permeation high-performance liquid chromatography (GP-HPLC) from the fermented milk by L. plantarum Q180. An ODS-AQ column was used for the RPC, a Vydac C18 column for the RP-HPLC, and a Superdex Peptide HR column for the GP-HPLC. The peptide was composed of Asp, Thr, Ile, Ser, Ala, and Gln, and the anti-lipase activity (IC50) was 2,817 ㎍/mL.