• Title/Summary/Keyword: interval load

Search Result 280, Processing Time 0.026 seconds

Coordination Control of Multiple Electrical Excited Synchronous Motors and Its Application in High-Power Metal-Rolling Systems

  • Shang, Jing;Nian, Xiaohong;Liu, Yong
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1781-1790
    • /
    • 2016
  • This study focuses on the coordination control problem of multiple electrical excited synchronous motor systems. A robust coordination controller is designed on the basis of cross coupling and an interval matrix. The proposed control strategy can deal with load uncertainty. In addition, the proposed control strategy is applied to a high-power metal-rolling system. Simulation and experiment results demonstrate that the proposed control strategy achieves good dynamic and static performance. It also shows better coordination performance than traditional proportional-integral controllers.

Customer's Effects of Momentary Voltage Sag in Power Distribution System Considering Reclosing Interval (리클로징 시간을 고려한 배전계통 순간전압강하의 수용가측 영향)

  • Moon, Jong-Fil;Kim, Jae-Chul;Kang, Bong-Seok;Yun, Sang-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.36-38
    • /
    • 2003
  • In this paper, It was evaluated that the customer's effects of momentary voltage sag in power distribution system considering reclosing interval. Above all, power quality problems were discussed widely, various international standards about power quality were compared to each other. after the continuous voltage sag waves of power distribution system on fault were induced, the experimentation about voltage sag for critical load was performed using source simulator. The results of experimentation were displayed as the form of 2 and 3-dimensional CBEMA Curve.

  • PDF

Optimal Handover Key Refresh Interval in 3GPP LTE/SAE Network (3GPP LTE/SAE 네트워크에서의 핸드오버 키 최적 갱신주기에 관한 연구)

  • Han, Chan-Kyu;Choi, Hyoung-Kee
    • The KIPS Transactions:PartC
    • /
    • v.18C no.4
    • /
    • pp.237-242
    • /
    • 2011
  • LTE/SAE has presented the handover key management to revoke the compromised keys and to isolate corrupted network devices. In this paper, we identify that the handover key management is vulnerable to so-called de-synchronization attacks, which is jeopardizing the forward secrecy of handover key management. We place an emphasis on periodic root key update to minimize the effect of the de-synchronization attacks. An optimal value for the root key update interval is suggested in order to minimize signaling load and ensure security of user traffic.

Robust Reliability Analysis of Vibration Components

  • Huang, Hong-Zhong;Li, Yong-Hua;Ming J. Zuo
    • International Journal of Reliability and Applications
    • /
    • v.5 no.2
    • /
    • pp.59-74
    • /
    • 2004
  • There are many uncertain parameters associated with vibration components. Their physical parameters, the machining quality of vibration components, and the applied load acting on them are all uncertain. As a result, the natural frequency and the fatigue limits are also uncertain variables. In this paper, we express these parameters of vibration components and the frequency zone of resonance through interval models; this way, the robust reliability of the vibration components is defined. The robust reliability model measures and assesses the reliability of vibration components. The robust reliability of a cantilever beam is evaluated as an example. The results show that this method is reasonable for robust reliability analysis of vibration components because it does not require a large amount of failure data, it avoids the evaluation of the probability density function, and the computation is simple.

  • PDF

Influence of Applying Loads on Subacromial Space Interval during Shoulder Abduction in Young Men (젊은 남성에서 부하 적용이 어깨 벌림 동안 봉우리밑 공간 간격에 미치는 영향)

  • Park, Kanghui;Park, Hankyu;Park, Sookyoung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.169-175
    • /
    • 2020
  • Purpose : This study was performed to comparison of distance change of subacromial space according to shoulder abduction angle in loaded and unloaded conditions. Methods : The subjects were 20 male college students, and the subacromial space was measured using an ultrasound diagnostic apparatus. The participants shoulder abduction was measured during each shoulder resting position and 45 ° abduction with loads of 1 kg, 2 kg, 3 kg. The collected data were analyzed by a paired t-test and repeated measure ANOVA with the SPSS (Ver. 22) program. Results : The subacromial space showed statistically significant decreased in 45 ° abduction than resting position (p<.001). All the subacromial space increased during the according to loads (1 kg, 2 kg, 3 kg) at the resting position but at 45 ° abduction showed statistically significant decreased as the load increases (p<.05). Also, subacromial space showed significant changes in the 2kg, 3kg compared with the 0kg loads. Conclusion : These results identified that shoulder abduction angle and load were related to subacromial space. When resting position, subacromial space is larger at loads than unload. As the load and shoulder abduction angle increase, subacromial space is reduced compared to resting.

Evaluation on Actual Discharge Data for TMDL in Nakdong River Basin (낙동강수계 수질오염총량관리를 위한 유량조사 평가)

  • Kim, Gyeong-Hoon;Kim, Yong-Seok;Park, Bae-Kyung;Yoon, Jong-Su;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.65-71
    • /
    • 2008
  • To drive efficiently total water pollution load management, needs to calculate the exact load emissions, pollution load allocation and implementation evaluation in each unit area of watershed and accurate and regular flow of data. For these reasons, the Nakdong River TMDL Research Center has produced directly or indirectly in the average interval of eight days (30 times or more / year) 41 points for unit area of the total water pollution load management and 8-point of municipal requirement for a total of 49 branches as a flow data in 2004 from August. This acquired the survey flow is evidence of trends and changes each point in the Nakdong River based on time, such as 10 years based on average design flow available to the foundation of the summit as the major water policy is to be utilized. This study was performed on actual discharge measuring data and introduced performance results each drainage basin of Nakdong River from 2004 to 2008 over the total of past five years.

Analyzing the effect on a Structural Stability of a Container Crane according to an Increased Wind velocity (풍속 증가에 따른 풍하중이 컨테이너 크레인의 구조 안정성에 미치는 영향)

  • Kwon S.K.;Han G.J.;Han D.S.;Lee S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.373-374
    • /
    • 2006
  • This study is carried out to analyze the stability of a container crane in according to the change of a wind direction and a machinery house location when a wind load of a wind velocity, 75m/s was applied on the state stowing a container crane by a heavy wind. A design wind load applied to this study was calculated in observance of 'Load Criteria of Building Structure'. And we analyzed the reactions of each supporting points according to appling a wind direction to an interval of $10^{\circ}\;in\;0^{\circ}{\sim}180^{\circ}$ and the structure stability of a container crane according to changing a machinery house. location occupying 15% of a container crane weight. From a results of this study, we presented a design criteria of an overturning disturbance equipment, tie-down.

  • PDF

Development of Ridge Regression Model of Pollutant Load Using Runoff Weighted Value Based on Distributed Curve-Number (분포형 CN 기반 토지피복별 유출가중치를 이용한 오염부하량 능형회귀모형 개발)

  • Song, Chul Min;Kim, Jin Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.1
    • /
    • pp.111-120
    • /
    • 2018
  • The purpose of this study was to develop a ridge regression (RR) model to estimate BOD and TP load using runoff weighted value. The concept of runoff weighted value, based on distributed curve-number (CN), was introduced to reflect the impact of land covers on runoff. The estimated runoff depths by distributed CN were closer to the observed values than those by area weighted mean CN. The RR is a technique used when the data suffers from multicollinearity. The RR model was developed for five flow duration intervals with the independent variables of daily runoff discharge of seven land covers and dependent variables of daily pollutant load. The RR model was applied to Heuk river watershed, a subwatershed of the Han river watershed. The variance inflation factors of the RR model decreased to the value less than 10. The RR model showed a good performance with Nash-Sutcliffe efficiency (NSE) of 0.73 and 0.87, and Pearson correlation coefficient of 0.88 and 0.93 for BOD and TP, respectively. The results suggest that the methods used in the study can be applied to estimate pollutant load of different land cover watersheds using limited data.

The Analysis of a Wind Load on a Container Crane Using a Computation Fluid Dynamics

  • Kwon, Soon-Kyu;Lee, Seong-Wook;Han, Dong-Seop;Han, Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.325-328
    • /
    • 2006
  • This study analyzed the fluid state around a container crane according to a wind direction when a wind load was applied to a container crane. The container crane for this research is a model of a 50-ton class used broadly in the current ports. The dimension of an external fluid field is $500m{\times}200m$. This study considered the change of a wind velocity according to an altitude in a criterion of a wind velocity, 50m/s, applying a power series law. An incident angle applied to an interval of 30 degrees in $0^{\circ}C$ ${\sim}$ $180^{\circ}C$ and this study carried out a computation fluid dynamics using a CFX 10. In this study, we indicate the wind pressure and coefficient according to the height and section figure of each member. In addition, we suggest the wind load according to a wind direction.

  • PDF

Interleaved ZVS DC/DC Converter with Balanced Input Capacitor Voltages for High-voltage Applications

  • Lin, Bor-Ren;Chiang, Huann-Keng;Wang, Shang-Lun
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.661-670
    • /
    • 2014
  • A new DC/DC converter with zero voltage switching is proposed for applications with high input voltage and high load current. The proposed converter has two circuit modules that share load current and power rating. Interleaved pulse-width modulation (PWM) is adopted to generate switch control signals. Thus, ripple currents are reduced at the input and output sides. For high-voltage applications, each circuit module includes two half-bridge legs that are connected in series to reduce switch voltage rating to $V_{in}/2$. These legs are controlled with the use of asymmetric PWM. To reduce the current rating of rectifier diodes and share load current for high-load-current applications, two center-tapped rectifiers are adopted in each circuit module. The primary windings of two transformers are connected in series at the high voltage side to balance output inductor currents. Two series capacitors are adopted at the AC terminals of the two half-bridge legs to balance the two input capacitor voltages. The resonant behavior of the inductance and capacitance at the transition interval enable MOSFETs to be switched on under zero voltage switching. The circuit configuration, system characteristics, and design are discussed in detail. Experiments based on a laboratory prototype are conducted to verify the effectiveness of the proposed converter.