• Title/Summary/Keyword: floors

Search Result 864, Processing Time 0.026 seconds

A Study on Estimation of Uncertainty in Measurement of Light Impact Sound Insulation of Floors (공동주택 경량바닥충격음 측정불확도 추정에 관한 연구)

  • Go, Jong-Chul;Lee, Jong-In;Kim, Hyun-Bae;Lee, Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1409-1416
    • /
    • 2006
  • In measuring, uncertainty in measurement is essential to improve measuring reliability. Currently, however, in measuring impact sound insulation of floors, there are no guidelines to estimate uncertainty in measurement. In addition, the concept of uncertainty in rating is required to recognize the relation between measuring and rating. Therefore, through this paper, the efforts have been made to establish uncertainty in measurement and rating of light impact insulation of floors. The result of estimating of uncertainty in measurement and rating in our laboratory is considered reliable, considering ${\pm}0.46{\sim}1.44dB$ of uncertainty in measurement and 1 dB of uncertainty in rating.

  • PDF

Design of Multiple Floors Autonomous Navigation System Based On ROS Enabled Mobile Robots (ROS 기반 모바일 로봇을위한 다중 층 자율 주행 시스템 설계)

  • Ahmed, Hamdi A.;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.55-57
    • /
    • 2018
  • In Simultaneous Localization and Mapping (SLAM), the robot acquire its map of environment while simultaneously localize itself relative to the map. Now a day, a map acquired by the mobile robots limit to specific area, in an indoor environment and cannot able to navigate autonomous between different floors. We propose a design that could able to overcome this issue in order to navigate multiple floors with one end goal mission to a target destination in the course of autonomous navigation. In this research, we consider all the floors have identical structural arrangement. Internet of Things (IoT) playing crucial role in bridging between "things" and Robot Operating System (ROS) enabled mobile robots.

  • PDF

A Survey on the Laboratory Measurements of Impact Sound Insulation of Floors (경량충격음 차단성능 실험실 측정방법 고찰)

  • Song, Min-Jeong;Jang, Gil-Soo;Ko, Sung-Suk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.976-979
    • /
    • 2004
  • The KS of 'Laboratory Measurement of Impact Sound Insulation of Floors' is not established yet. To establish this KS, present conditions of domestic laboratory test facilities for measuring impact sound insulation of floors in laboratory and current researches were reviewed As a result the outline of 'Laboratory Measurement of Impact Sound Insulation of Floors' is suggested.

  • PDF

Vibration analysis and FE model updating of lightweight steel floors in full-scale prefabricated building

  • Petrovic-Kotur, Smiljana P.;Pavic, Aleksandar P.
    • Structural Engineering and Mechanics
    • /
    • v.58 no.2
    • /
    • pp.277-300
    • /
    • 2016
  • Cold-formed steel (CFS) sections are becoming an increasingly popular solution for constructing floors in residential, healthcare and education buildings. Their reduced weight, however, makes them prone to excessive vibrations, increasing the need for accurate prediction of CFS floor modal properties. By combining experimental modal analysis of a full-scale CFS framed building and its floors and their numerical finite element (FE) modelling this paper demonstrates that the existing methods (based on the best engineering judgement) for predicting CFS floor modal properties are unreliable. They can yield over 40% difference between the predicted and measured natural frequencies for important modes of vibration. This is because the methods were adopted from other floor types (e.g., timber or standard steel-concrete composite floors) and do not take into account specific features of CFS floors. Using the adjusted and then updated FE model, featuring semi-rigid connections led to markedly improved results. The first four measured and calculated CFS floor natural frequencies matched exactly and all relevant modal assurance criterion (MAC) values were above 90%. The introduction of flexible supports and more realistic modelling of the floor boundary conditions, as well as non-structural $fa{\c{c}}ade$ walls, proved to be crucial in the development of the new more successful modelling strategy. The process used to develop 10 identified and experimentally verified FE modelling parameters is based on published information and parameter adjustment resulting from FE model updating. This can be utilised for future design of similar lightweight steel floors in prefabricated buildings when checking their vibration serviceability, likely to be their governing design criterion.

A Case of Sprinkler Non-Working by Programming Error (프로그래밍 오류에 의한 스프링클러 미작동 사례)

  • Seo, Young-Il;Cho, Young-Jin;Moon, Byung-Seon;Park, Jong-Jin;Park, Jong-Chan;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.116-120
    • /
    • 2008
  • According to the Fire Services Act revised in 2005, it has been required to set up sprinkler systems to all floors to the newly builded apartments having above 11 floors. But, according to the Fire Services Act before 2005, it had been required to set up sprinkler systems from 16 floors to the top floors to the apartments having above 16 floors. This case is the accident that a victim was dead by the fire which is inferred as an accidental fire by a cigarette butt in a 17th floor apartment unit in an apartment having 17th floors and that the bereaved family called in question why the sprinklers non worked at the fire. Through the field investigation, we checked that the sprinklers worked well when the fire detectors at the 16th floor of the apartment were operated and that the sprinklers non worked when the fire detectors at the 17th floor of the apartment were operated. We made clear that the cause of the sprinkler non-working at the 17th floor is the programming error of the sprinkler controller.

A Study on analyzing the space of Villa VPRO used datascape design strategy (데이터스케이프 설계방법을 적용한 Villa VPRO 공간분석 연구)

  • 박영경
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.3
    • /
    • pp.145-152
    • /
    • 2004
  • The European architects including MVRDV, Rem Koolhaas, Van Berkel, and Zaha Hadid tend to use the their own design strategy based on the objective data. This Architectural design method leads to make new paradigm of contemporary architecture. For the purpose of the understanding a part of new architecture paradigm I will analyze the case of Villa VPRO designed by MVRDV. At the result, I can draw the following conclusions. First, through collecting and analyzing data, drawing design concept and planning the space program, they decided on the design strategies of Villa VPRO. They designed the space volume having 42.4m$\times$42.4m floors and infiltrated environmental elements to solve the problems about deep space. Second, Villa VPRO was constructed by 'creative space-making system: a series of floors much like a geological formation, the continuous floors interconnected by spatial means, the precision bombardments of snake-like holes, open elevations, the stacking spaces. Third, Villa VPRO produced the spectacle space effect the various formation of continuous floors make a lot of difference space types in this building. Also they lead to move naturally and give event space. A numbers of holes and openness make it possible to provide friendly environment with combining light and air with views of the surrounding and transparency. And using the method of stacking many types of space make the differences in height.

The Performance of Insulation of Noise by Air between Floors According to Structure Systems of Apartment (공동주택 구조형태별 층간 공기전달음 차단 성능)

  • Lee, Byung-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1152-1155
    • /
    • 2007
  • Lately concerns about structure have been increased by advantages of floor impact noise, poilitical induction and changeability. Hence, Flat Plate Structure has been constructed increasingly. This study shows the comparison of the performance of sound insulation of Flat Plate Structure System and the existing Wall Structure. For this study, taking the same level organization of Daelim Architectural Environmental Research Center, I found the performance of sound insulation between the upper and lower floors about Wall Structure and Flat Plate Structure. Consequently, the performance of sound insulation between upper and lower floors of Flat Plate Structure was 3-5dB higher was approximately 3-5dB higher than one of Wall Structure. Especially, the performance of sound insulation on the upper floor was 1-3dB higher than on the lower floor. In addition, as the result of comparing radiation sound which radiates from the wall of lower floors with each structure system, Flat Plate Structure was about 4dB higher with Rw than Wall Structure. As we see totally, the performance of sound insulation of Flat Plate Structure is highter than one of the Wall Structure. It is 3-5dB higher and the main reason for this result depends on the existence of the wall which can radiate sound and nonexistence.

  • PDF

Preferences for High-rise Mixed Use Buildings (HMUBs) for Living Space in Later Life Among Urban Residents

  • Hong, Hyung-Ock
    • International Journal of Human Ecology
    • /
    • v.7 no.2
    • /
    • pp.17-27
    • /
    • 2006
  • The purpose of this research was to find out the preferences in HMUBs for living space in respondents' later life. For this purpose, this research was conducted by social survey research using a questionnaire for those who lived in an urban area around Seoul. The data was collected from November to December, 2005. The results of this research were as follows. Firstly, respondents agreed with living in high rise mixed use buildings in their later life because of convenience. Willingness to move into HMUBs was positive. Concerning preferred physical features, residents preferred living in either lower floors or higher floors because of safety or fine views. Regarding the usage of common space and facilities, they wanted to use them with other generations and preferred 2 bedroom type unit located in a suburban area. Secondly, the preference for living in a HMUB in later life was higher in women respondents than in men. Thirdly, the preference for living in a HMUB in later life was higher in upper floors than lower floors according to property and asset value. As a conclusion, the development of HMUB housing for older people has a bright prospect for urban residents in Korea.

Analysis of Heating Energy in a Korean-Style Apartment Building 1: The Effect of Location (한국형 아파트의 난방에너지 분석 1: 위치의 영향)

  • 유호선;현석균;박유원;김용식;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.101-110
    • /
    • 2004
  • This paper presents an analysis of heating energy for apartment houses in a Korean-style apartment building, paying special attention on the effect of their location. Six representative locations encompass three floors and two placements on each floor. Two different roof types are also considered. In order to incorporate actual tenant's refit, a five-zone model composed of one conditioned and four unconditioned spaces is developed. TRNSYS 15 is adopted to estimate heating energy. The predicted results show fairly good agreements with the available measured data, validating the present model. Heating energy needed for an apartment located at the uppermost and lowermost floors is far greater compared with the case of intermediate floors. In addition, an appreciable difference is found between apartment with and without side end wall. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. Ridged-roofs instead of flat-roofs are highly recommended in apartment buildings for effective energy saving. It is finally concluded that the location-dependent, severe imbalance in heating energy should be improved and/or reflected in the policy making process and design standards.

Error Estimate of Local Vibration for Building Structures Using Substructure Models (부분구조모델을 이용한 건축물의 국부진동해석에서의 오차원인 분석)

  • 안상경;이현수;이동근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.545-552
    • /
    • 2001
  • Analysis of a structure for vertical vibration requires a lot of computational efforts because large number of degrees of freedom are generally involved in the dynamic response. Especially, when a structure is loaded with local vibration source, it may not be economical to model the whole structure to obtain the responses of specific members located near or far from the sources. In this study, substructure models have been used for analysis of local vibration An analysis of local vibration is performed for the case that the loaded point and the response point are located on the same floor. Other analysis is performed for the case that the loaded point and the response point are located on the different floor. In this case, if only the floors on which loaded and response points are located are modeled, response of substructure model is very different from that of full model. So, there should be a consideration that degrees of freedom of floors in addition to those of loaded and response floors are included to improve results of dynamic analysis. In this study, floors between loaded floor and response floor were modeled so that modeshapes which affect the response are presented well.

  • PDF