초록

This paper presents an analysis of heating energy for apartment houses in a Korean-style apartment building, paying special attention on the effect of their location. Six representative locations encompass three floors and two placements on each floor. Two different roof types are also considered. In order to incorporate actual tenant's refit, a five-zone model composed of one conditioned and four unconditioned spaces is developed. TRNSYS 15 is adopted to estimate heating energy. The predicted results show fairly good agreements with the available measured data, validating the present model. Heating energy needed for an apartment located at the uppermost and lowermost floors is far greater compared with the case of intermediate floors. In addition, an appreciable difference is found between apartment with and without side end wall. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. Ridged-roofs instead of flat-roofs are highly recommended in apartment buildings for effective energy saving. It is finally concluded that the location-dependent, severe imbalance in heating energy should be improved and/or reflected in the policy making process and design standards.

키워드

참고문헌

  1. Report of residence The Census of Population and Residence 2000 Korean National Statistical Office
  2. Mid- and Long-Term Policy Improvements for Efficient Utilization of Energy in Building Sector Industry and Energy Ministry of Commerce
  3. Korean Journal of Air Conditioning and Refrigeration Engineering v.14 no.11 Effects of various factors on the energy consumption of Koean-style apartment houses Yoo,H.;Hyun,S.K.;Hong,H.
  4. Korean Journal of Architectural Institute of Korea v.11 no.7 A study on characteristics of evergy consumption in apartment buildings Kang,J.S.;Lee,S.E.;Ahn,T.K.
  5. Journal of Korean Association of Air Conditioning, Refrigerating and Sanitary Engineers Report of energy consumption depending on the location and floor for apartment house Kang,J.S.
  6. Proceedings of the SAREK 2003 Winter Annual Conference Survey on energy consumption according to heating methods in apartment houses Lee,B.J.;Chung,D.Y.;Lee,S.;Hong.H.
  7. Proceedings of the SAREK 2001 Summer Annual Conference An evaluation on natural ventilation in apartment houses Park,J.W.;Bae,S.H.;Hong,C.H.
  8. Korean Journal of Air Conditioning and Refrigeration Engineering v.14 no.2 Verification experiment and calcuation of heating load for a test space Hyun,S.K.;Hong,H.;Yoo,H.
  9. Korean Journal of Air Conditioning and Refirgeration Engineering v.15 no.8 Verification experiement and calculation of cooling load for a test space Yoo,H.;Hyun,S.K.;Kim,Y.S.-Hong,H.
  10. TRNSYS Reference Manual Solar Energy Laboratory