Browse > Article

Analysis of Heating Energy in a Korean-Style Apartment Building 1: The Effect of Location  

유호선 (숭실대학교 기계공학과)
현석균 ((주)ATES CFD 솔루션사업부)
박유원 (경희대학교 대학원 기계공학과)
김용식 (청운대학교 건축환경설비학과)
홍희기 (경희대학교 기계산업시스템공학부)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.16, no.1, 2004 , pp. 101-110 More about this Journal
Abstract
This paper presents an analysis of heating energy for apartment houses in a Korean-style apartment building, paying special attention on the effect of their location. Six representative locations encompass three floors and two placements on each floor. Two different roof types are also considered. In order to incorporate actual tenant's refit, a five-zone model composed of one conditioned and four unconditioned spaces is developed. TRNSYS 15 is adopted to estimate heating energy. The predicted results show fairly good agreements with the available measured data, validating the present model. Heating energy needed for an apartment located at the uppermost and lowermost floors is far greater compared with the case of intermediate floors. In addition, an appreciable difference is found between apartment with and without side end wall. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. Ridged-roofs instead of flat-roofs are highly recommended in apartment buildings for effective energy saving. It is finally concluded that the location-dependent, severe imbalance in heating energy should be improved and/or reflected in the policy making process and design standards.
Keywords
Energy estimation; Korean-style apartment house; Heating energy; TRNSYS;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Verification experiement and calculation of cooling load for a test space /
[ Yoo,H.;Hyun,S.K.;Kim,Y.S.-Hong,H. ] / Korean Journal of Air Conditioning and Refirgeration Engineering   과학기술학회마을
2 The Census of Population and Residence 2000 /
[ Korean National Statistical Office ] / Report of residence
3 Survey on energy consumption according to heating methods in apartment houses /
[ Lee,B.J.;Chung,D.Y.;Lee,S.;Hong.H. ] / Proceedings of the SAREK 2003 Winter Annual Conference
4 A study on characteristics of evergy consumption in apartment buildings /
[ Kang,J.S.;Lee,S.E.;Ahn,T.K. ] / Korean Journal of Architectural Institute of Korea
5 Report of energy consumption depending on the location and floor for apartment house /
[ Kang,J.S. ] / Journal of Korean Association of Air Conditioning, Refrigerating and Sanitary Engineers
6 Verification experiment and calcuation of heating load for a test space /
[ Hyun,S.K.;Hong,H.;Yoo,H. ] / Korean Journal of Air Conditioning and Refrigeration Engineering   과학기술학회마을
7 Industry and Energy /
[ Ministry of Commerce ] / Mid- and Long-Term Policy Improvements for Efficient Utilization of Energy in Building Sector
8 Effects of various factors on the energy consumption of Koean-style apartment houses /
[ Yoo,H.;Hyun,S.K.;Hong,H. ] / Korean Journal of Air Conditioning and Refrigeration Engineering   과학기술학회마을
9 An evaluation on natural ventilation in apartment houses /
[ Park,J.W.;Bae,S.H.;Hong,C.H. ] / Proceedings of the SAREK 2001 Summer Annual Conference
10 /
[ Solar Energy Laboratory ] / TRNSYS Reference Manual