• Title/Summary/Keyword: fault core

Search Result 291, Processing Time 0.02 seconds

Characteristics of Lode Development and Structural Interpretation for the High Au Contents within the Fault Gouge Zones in Jinsan Au Mine, Chungcheongnam-do (충남 금산 진산금광산의 광맥 발달특성과 단층점토에 농집된 고품위 금함량에 대한 구조지질학적 해석)

  • Shin, Dongbok;Gwon, Sehyeon;Kim, Young-Seog
    • Economic and Environmental Geology
    • /
    • v.48 no.2
    • /
    • pp.103-114
    • /
    • 2015
  • Jinsan gold deposit is a hydrothermal vein type deposit consisting of several fissure filling quartz veins developed within the Changri Formation of the Ogcheon Supergroup in Geumsan, Chungnam. This study is to provide an efficient exploration and development strategies based on the characteristics of the geology, geological structure, core logging, and ore vein occurrence and grade for the four pits (New pit, Main pit, Yanghapan pit and Teugho pit). Quartz veins are mostly developed with the strike of $N10^{\circ}-25^{\circ}W$ and $N5^{\circ}-20^{\circ}E$, and the thickness is in the range of 0.1~0.5 m, sometimes extending to over 1m. Although the quartz veins commonly form massive shape, they sometimes show zonal structure, comb structure as well as brecciated texture. Major ore minerals are pyrite and chalcopyrite, and pyrrhotite, sphalerite, galena, marcasite, electrum and chalcocite are also accompanied as minor phases. Gray and milky white quartz veins, which are occasionally crosscut by calcite vein, also include fluorite. Ore evaluations for the 22 samples revealed that the samples from the pits generally have very low Au contents, lower than 1 g/t, but some clay samples of drilled core show very high Au concentrations, up to 141 g/t, indicating that Au content is much higher within fault gouges rather than within fresh quartz veins. This may represent that gold might have been reworked and reprecipitated by hydrothermal fluids in association with reactivation of the faults, and thus suggest that ore occurrence in this deposit is very complex and irregular and therefore more precise and systematic exploration is required.

Ground Characterization of the Cheongju Granite Area Using the Geophysical Methods (물리탐사를 이용한 청주 화강암 지역의 지반특성 파악)

  • Kim Ji-Soo;Han Soo-Hyung;Seo Yong-Seok;Lee Yong-Jae
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.41-55
    • /
    • 2005
  • This research is aimed at investigating the ground characterization of the Cheongju granite area using the geophysical methods. Test site was chosen from the building site in Chungbuk University, Chongju, Chungbuk province. Furthermore, geophysical methods are employed on the outcrops in the east to map the distribution of fault and intrusion and reveal the degree of weathering. The subsurface structure mapped from seismic re-fraction survey mainly consists of two units of weathered soil and rock. Threshold of the units were determined on the basis of seismic velocity of 800 m/s, supported from the standard classification table. From the results of standard penetrating test(SPT), these units are found to show medium-high and high density, respectively. Weathering soil is subdivided in unsaturated layer and saturated layer with thresholds of seismic velocity (500 m/s) and resistivity (200 ohm-m). In particular, unsaturated layer is again classified into dry and wet portions using the GPR section. The boundary between unsaturated and saturated weathering soils corresponds to the groundwater table at depth of approximately 5~6.2 m, which is well correlated with the one from drill-core data. However, bedrock is not delineated by geophysical methods. In the GPR section, fault and intrusion observed on the outcrop are revealed not to extend to the building site. With respect to weathering degree, the outcrop characterized by low resistivity and velocity corresponds to the grade of 'completely weathered' from the geotechnical investigations.

Case histories on design alternatives during excavation of underground LPG storage cavern and traffic tunnel using TSP survey (TSP 탐사를 이용한 지하유류저장공동 및 도로터널의 시공 중 설계변경 사례 고찰)

  • Cha Sung-Soo;Kim Se-Hoon;Yun Sang-Pil;Bae Jung-Sik;Lee Jin-Moo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.117-136
    • /
    • 1999
  • The geophysical survey at pre-investigation stage can hardly provide the detailed information on geological structure of site which has difficulty in access and thick overburden. The TSP (VSP applied in tunnel) survey at post-investigation stage can show the detailed geology ahead of tunnel and around cavern. The TSP survey was carried out at the Pyongtaek LPG storage cavern site during the cavern excavation and provided the location and orientation of the fault inferred below Namyangho. In order to confirm the result of TSP survey four boreholes were drilled in access tunnel. The fault was also detected by borehole survey and the location was coincided with the result of TSP survey. Depend on the result of TSP survey and core logging, the design such as cavern layout and length could have been changed. As another case history the TSP survey was performed at the Mumeuje road tunnel which has poor geological information due to thick overburden. The support design was also changed on the base of TSP survey.

  • PDF

A Survivability Model of an Intrusion Tolerance System (침입감내시스템의 생존성 모델)

  • Park, Bum-Joo;Park, Kie-Jin;Kim, Sung-Soo
    • The KIPS Transactions:PartA
    • /
    • v.12A no.5 s.95
    • /
    • pp.395-404
    • /
    • 2005
  • There have been large concerns about survivability defined as the capability of a system to perform a mission-critical role, in a timely manner, in the presence of attacks, failures. In particular, One of the most important core technologies required for the design of the ITS(Intrusion Tolerance System) that performs continuously minimal essential services even when the computer system is partially compromised because of intrusions is the survivability one of In included the dependability analysis of a reliability and availability etc. quantitative dependability analysis of the In. In this Paper, we applied self-healing mechanism utilizing two factors of self-healing mechanism (fault model and system response), the core technology of autonomic computing to secure the protection power of the ITS and consisted of a state transition diagram of the ITS composed of a primary server and a backup server. We also defined the survivability, availability, and downtime cost of the ITS, and then performed studies on simulation experiments and two cases of vulnerability attack. Simulation results show that intrusion tolerance capability at the initial state is more important than coping capability at the attack state in terms of the dependability enhancement.

A Study on the Revised Draft of Rome Convention on Compensation for Damage Caused by Aircraft to Third Parties - With Respect to the Draft Unlawful Interference Compensation Convention and the Draft General Risks Convention - (항공기에 의하여 발생된 제3자 손해배상에 관한 로마협약 개정안에 대한 고찰 - 불법방해배상협약안과 일반위험협약안을 중심으로 -)

  • Lee, Kang-Bin
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.22 no.2
    • /
    • pp.27-51
    • /
    • 2007
  • The cumulative result of the work by the ICAO Secretariat, the Secretariat Study Group and the Council Special Group on the Modernization of the Rome Convention of 1952 are two draft Conventions, namely: "Draft Convention on Compensation for Damage Caused by Aircraft to Third Parties, in case of Unlawful Interference", and "Draft Convention on Compensation for Damage Caused by Aircraft to Third Parties" The core provisions of the former draft Convention are as follows: The liability of the operator is strict, that is, without the necessity of proof of fault. It would be liable for damage sustained by third parties on condition only that the damage was caused by an aircraft in flight(Article 3). However, such liability is caped based on the weight of the aircraft(Article 4). It is envisaged to create an independent organization called the Supplementary Compensation Mechanism, with the principle purpose to pay compensation to persons suffering damage in the territory of a State Party, and to provide financial support(Article 8). Compensation shall be paid by the SCM to the extent that the total amount of damages exceeds the Article 4 limits(Article 19). The main issues on the farmer draft Convention are relating to breaking away from Montreal Convention 1999, no limits on individual claims but a global limitation on air carrier liability, insurance coverage, cap of operators' strict liability, and Supplementary Compensation Mechanism. The core provisions of the latter draft Convention are as follows: the liability of the operator is strict, up to a certain threshold tentatively set at 250,000 to 500,000 SDRs. Beyond that, the operator is liable for all damages unless it proves that such damage were not due to its negligence or that the damages were solely due to the negligence of another person(Article 3). The provisions relating to the SCM and compensation thereunder do not operate under this Convention, as the operator is potentially for the full amount of damages caused. The main issues on the latter draft Convention are relating to liability limit of operator, and definition of general risks. In conclusion, we urge ICAO to move forward expeditiously on the draft Convention to establish a third party liability and compensation system that can stand ready to protect both third party victims and the aviation industry before another 9/11-scale event occurs.

  • PDF

Geology and Geochemistry of Volcanic and Sedimentary Rocks from Deep Borehole in the Heunghae area, North Kyungsang Province (경북 흥해지역 심부시추공의 화산암 및 퇴적암류의 지질 및 지화학적 연구)

  • Lee, Chang-Bum;Kim, Tong-Kwon;Park, Deok-Won
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.459-474
    • /
    • 2009
  • By the analysis of discontinuity at the outcrop and lineament on the satellite image, the joints have deeply relationship with the lineaments. The joint spaces at the drilling core are mostly 1~20 cm but at the rhyolite which is distributed near fault they have more closely. These volcanic rocks belong to the subalkaline series tuff, rhyolite, basalt in the study area from the diagram of $Nb/Y-Zr/TiO_2$. The composition diagram of Hf/3-Th-Nb/16 show destructive plate-margin basalt and their differentiates. The environment of formation of volcanics are normal continental arc. Most of LREE show high enriched pattern but HREE show depleted pattern. The K/Ar age of intermediate volcanics, tuff, rhyolite, crystal tuff are 55.3Ma, 77.25 Ma~91.22Ma, 63.16~64.39Ma, 54.49 Ma respectively.

Design for Self-Repair Systm by Embeded Self-Detection Circuit (자가검출회로 내장의 자가치유시스템 설계)

  • Seo Jung-Il;Seong Nak-Hun;Oh Taik-Jin;Yang Hyun-Mo;Choi Ho-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.5 s.335
    • /
    • pp.15-22
    • /
    • 2005
  • This paper proposes an efficient structure which is able to perform self-detection and self-repair for faults in a digital system by imitating the structure of living beings. The self-repair system is composed of artificial cells, which have homogeneous structures in the two-dimension, and spare cells. An artificial cell is composed of a logic block based on multiplexers, and a genome block, which controls the logic block. The cell is designed using DCVSL (differential cascode voltage switch logic) structure to self-detect faults. If a fault occurs in an artificial cell, it is self-detected by the DCVSL. Then the artificial cells which belong to the column are disabled and reconfigured using both neighbour cells and spare cells to be repaired. A self-repairable 2-bit up/down counter has been fabricated using Hynix $0.35{\mu}m$ technology with $1.14{\times}0.99mm^2$ core area and verified through the circuit simulation and chip test.

A Clustered Reconfigurable Interconnection Network BIST Based on Signal Probabilities of Deterministic Test Sets (결정론적 테스트 세트의 신호확률에 기반을 둔 clustered reconfigurable interconnection network 내장된 자체 테스트 기법)

  • Song Dong-Sup;Kang Sungho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.79-90
    • /
    • 2005
  • In this paper, we propose a new clustered reconfigurable interconnect network (CRIN) BIST to improve the embedding probabilities of random-pattern-resistant-patterns. The proposed method uses a scan-cell reordering technique based on the signal probabilities of given test cubes and specific hardware blocks that increases the embedding probabilities of care bit clustered scan chain test cubes. We have developed a simulated annealing based algorithm that maximizes the embedding probabilities of scan chain test cubes to reorder scan cells, and an iterative algorithm for synthesizing the CRIN hardware. Experimental results demonstrate that the proposed CRIN BIST technique achieves complete fault coverage with lower storage requirement and shorter testing time in comparison with the conventional methods.

Bi-Directional Buck-Boost Forward Converter for Photovoltaic Module type Power Conditioning System (태양광 모듈형 전력조절기를 위한 양방향 벅-부스트 포워드 컨버터)

  • Kim, Kyoung-Tak;Jeon, Young-Tae;Park, Joung-Hu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.335-342
    • /
    • 2016
  • This paper proposes an energy storage-assisted, series-connected module-integrated power conversion system that integrates a photovoltaic power conditioner and a charge balancing circuit. In conventional methods, a photovoltaic power conditioner and a cell-balancing circuit are needed for photovoltaic systems with energy storage devices, but they cause a complex configuration and high cost. Moreover, an imbalanced output voltage of the module-integrated converter for PV panels can be a result of partial shading. Partial shading can lead to the fault condition of the boost converter in shaded modules and high voltage stresses on the devices in other modules. To overcome these problems, a bidirectional buck-boost converter with an integrated magnetic device operating for a charge-balancing circuit is proposed. The proposed circuit has multiple secondary rectifiers with inductors sharing a single magnetic core, which works as an inductor for the main bidirectional charger/discharger of the energy storage. The secondary rectifiers operate as a cell-balancing circuit for both energy storage and the series-connected multiple outputs of the module-integrated converter. The operating principle of the cell-balancing power conversion circuit and the power stage design are presented and validated by PSIM simulation for analysis. A hardware prototype with equivalent photovoltaic modules is implemented for verification. The results verify that the modularized photovoltaic power conversion system in the output series with an energy storage successfully works with the proposed low-cost bidirectional buck-boost converter comprising a single magnetic device.

Analysis of Slope Stability at the End of OO tunnel being Distributed by Mica Schist (운모편암 분포지인 OO 터널 종점부에서 절토사면의 안전성 분석 연구)

  • Lee, Byung-Joo;SunWoo, Choon
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.287-294
    • /
    • 2009
  • To be design the slope, the area distributed the mica schist which was metamorphosed by shale or mudstone must carefully consider the stability. Mica schist is another unstable rock for slope by schistosity, cleavage, axial plane of a fold etc. In general mica schist contains the swelling clay minerals such as smectite, vermiculite and montmorillonite. These minerals make the slope unstable. At OO tunnel construction area for the rail way of the Kyungbu high speed train, the slope of mica schist is very unstable by the distribution phenomena of the discontinuous plane such as joints which are 1-5 cm spacing and thrust and strike-slip fault. By the drilling core of this area, most RQD have 0-20%.