• Title/Summary/Keyword: elastic substrate

Search Result 177, Processing Time 0.03 seconds

Variation of Elastic Stiffness of Polydimethylsiloxane (PDMS) Stretchable Substrates for Wearable Packaging Applications (웨어러블 패키징용 Polydimethylsiloxane (PDMS) 신축성 기판의 강성도 변화거동)

  • Choi, Jung-Yeol;Park, Dae-Woong;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.125-131
    • /
    • 2014
  • In order to develop stretchable substrates for wearable packaging applications, the variation behavior of elastic modulus was evaluated for transparent PDMS Sylgard 184 and black PDMS Sylgard 170 as a function of the base/curing agent mixing ratio. Both for Sylgard 184 and Sylgard 170, the true elastic modulus evaluated on a true stress-true strain curve was higher more than two times compared to the engineering elastic modulus obtained from an engineering stres-sengineering strain curve, and their difference became larger with increasing the stiffness of the PDMS. Sylgard 184 exhibited a maximum engineering elastic modulus of 1.74 MPa and a maximum true elastic modulus of 3.57 MPa at the base/curing agent mixing ratio of 10. A maximum engineering elastic modulus of 1.51 MPa and a maximum true elastic modulus of 3.64 MPa were obtained for Sylgard 170 at the base/curing agent mixing ratio of 2.

Temperature Characteristics of Elastic Layer Mode Propagating on Piezoelectric Crystal (이층구조의 전반로를 갖는 단성표면파의 온도특성)

  • 김완상
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.6
    • /
    • pp.56-61
    • /
    • 1973
  • The temperature coefficients and phase velocity dispersions of elastic surface wave layer mode with Ag or Pd layer on piezoelectric LiNbO3 svbstrate rotated 131$^{\circ}$ Y out are calculated as a function of thickness by numerical method. Calculated results are shown that the temperature coefficients are rapidly increased in proportion as the thickness of Ag layer increases. and irregular variation of the temperature coefficients appears in the case of Pd layer. Minimum value, -36$\times$10 /$^{\circ}C$, of the temperature coefficients of elastic surface wave with Pd layer on LiMbO3 substrate rotated 131$^{\circ}$ Y cut is obtained at wh=9000.

  • PDF

One-Step Nanoscale Patterning of Silver Ionic Ink via Elastic Mold Deformation (탄성 몰드 변형을 이용한 은 이온 잉크의 원-스텝 나노스케일 패터닝)

  • Yong Suk Oh
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.252-256
    • /
    • 2023
  • A one-step method for nanoscale patterning of silver ionic ink on a substrate is developed using a microscale, elastic mold deformation. This method yields unique micro/nanoscale metallic structures that differ from those produced using the original molds. The linewidth of these metallic structures is significantly reduced (approximately 10 times) through the sidewall deformation of the original mold cavity on a thin liquid film, as verified by finite element analysis. The process facilitates the fabrication of various, isolated and complex micro/nanoscale metallic structures with negligible residual layers at low cost and high throughput. These structures can be utilized for various applications, including optoelectronics, wearable sensors, and metaverse-related devices. Our approach offers a promising tool for manipulation and fabrication of micro/nanoscale structures of various functional materials.

Development of novel strain sensor using surface acoustic wave (새로운 표면탄성파를 이용한 변형률 센서 개발)

  • Oh, Hae-Kwan;Hwang, U-Jin;Eun, Kyung-Tae;Choa, Sung-Hun;Lee, Kee-Keun;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.594-599
    • /
    • 2011
  • A SAW strain sensor based on Shear Horizontal wave with an 92 MHz central frequency was developed. It consists of SAW sensor, PCB substrate and bonding material (Loctite 401). External force applied to PCB substrate bonded to a piezoelectric substrate induces strain at the substrate surface, which causes changes in the elastic constant and density of the substrate and hence the propagation velocity of the SAW. The change in the velocity of the SAW result in a frequency shift of the sensor and by measuring a frequency shift, we can extract the strain induced by the external force. The $41^{\circ}$ YX $LiNbO_3$ was used because it has a Leaky shear horizontal(SH) wave propagation mode and a high electromechanical coupling coefficient ($K^2$=17.2%). And to compare with Rayleigh wave mode, $128^{\circ}$ YX $LiNbO_3$ was used. And to make a stable and low insert loss, Split IDT structure was used. The obtained sensitivity and linearity of the SAW strain sensor in the case of Split IDT were measured to be 17.2 kHz / % and 0.99, respectively.

Effect of Negative Substrate Bias Voltage on the Microstructure and Mechanical Properties of Nanostructured Ti-Al-N-O Coatings Prepared by Cathodic Arc Evaporation

  • Heo, Sungbo;Kim, Wang Ryeol;Park, In-Wook
    • Journal of Surface Science and Engineering
    • /
    • v.54 no.3
    • /
    • pp.133-138
    • /
    • 2021
  • Ternary Ti-X-N coatings, where X = Al, Si, Cr, O, etc., have been widely used for machining tools and cutting tools such as inserts, end-mills, and etc. Ti-Al-N-O coatings were deposited onto silicon wafer and WC-Co substrates by a cathodic arc evaporation (CAE) technique at various negative substrate bias voltages. In this study, the influence of substrate bias voltages during deposition on the microstructure and mechanical properties of Ti-Al-N-O coatings were systematically investigated to optimize the CAE deposition condition. Based on results from various analyses, the Ti-Al-N-O coatings prepared at substrate bias voltage of -80 V in the process exhibited excellent mechanical properties with a higher compressive residual stress. The Ti-Al-N-O (-80 V) coating exhibited the highest hardness around 30 GPa and elastic modulus around 303 GPa. The improvement of mechanical properties with optimized bias voltage of -80 V can be explained with the diminution of macroparticles, film densification and residual stress induced by ion bombardment effect. However, the increasing bias voltage above -80 V caused reduction in film deposition rate in the Ti-Al-N-O coatings due to re-sputtering and ion bombardment phenomenon.

Analysis of the Growth Characteristics of Cardiac Cells According to Mechanical Properties of Substrates Using the Simplified Measurement Technique of Tracker

  • Abdullah, Abdullah;Kanade, Pooja P.;Oyunbaatar, Nomin-Erdene;Jeong, Yun-Jin;Kim, Dong-Su;Lee, Dong-Weon
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.6-11
    • /
    • 2022
  • To date, various techniques have been utilized to assess the contractility of cardiomyocytes and their response to drug-induced toxicity. However, these techniques are either invasive or involve complex fabrication methods and expertise. Here, we introduce the use of video-based analysis software to track the motion of cardiomyocytes and assess their contractility. The software, called "Tracker", is freely available and this is the first attempt at using it for cardiac contractility measurement. We used the software to measure the contractile properties of cells cultured on a rigid substrate and two flexible polydimethylsiloxane (PDMS) substrates having different elastic moduli day-wise up to eight days. Contractility was found to be highest in the most flexible substrate. Subsequently, the cardiotoxicity response of the cells on three different substrates was analyzed with verapamil. It was observed that the cells on rigid substrate were primarily affected by drug-induced toxicity, while the drug had a lesser impact on cells on the more flexible PDMS substrate. Evidently, the flexible substrate aided the maturation of cells and had lower drug toxicity, while the cells on PS could not fully mature. The assessment of cardiomyocytes using "Tracker" proved to be simple and reliable.

Tensile Analysis of Plasma Spray Coating Material by Classification of AE Signals (Acoustic Emission 파형분류에 의한 플라즈마 용사 코팅재의 인장해석)

  • ;;K. ONO
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.60-65
    • /
    • 2001
  • Thermal spray coating is formed by a process in which melted particles flying with high speed towards substrate, then crash and spread on the substrate surface cooled and solidified in a very short time, Stacking of the particles makes coating. In this study, the exfoliation of $Al_2$O$_3$ and Ni-4.5wt.%Al thermally sprayed coating which were deposited by an atmospheric plasma spray apparatus are investigated using an AE method. A tensile test is conducted on notch specimens in a stress range below the elastic limit of substrate. The wave forms of AE generated from the three coating specimens can be classified by FFT analysis into two types which low frequency(type I waveform is considered to corresponds exfoliation of coating layers and type II waveform corresponds the plastic deformation of notch tip or the resultant fracture of coating. The fracture of the coating layers can estimate by AE event and amplitude, because AE features increase when the deformation generates.

  • PDF

A Novel Stiff Membrane Seesaw Type RF Microelectromechanical System DC Contact Switch on Quartz Substrate

  • Khaira, Navjot K.;Singh, Tejinder;Sengar, Jitendra S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.3
    • /
    • pp.116-120
    • /
    • 2013
  • This paper proposes a novel RF MEMS dc-contact switch with stiff membrane on a quartz substrate. The uniqueness of this work lies in the utilization of a seesaw mechanism to restore the movable part to its rest position. The switching action is done by using separate pull-down and pull-up electrodes, and hence operation of the switch does not rely on the elastic recovery force of the membrane. One of the main problems faced by electrostatically actuated MEMS switches is the high operational voltages, which results from bending of the membrane, due to internal stress gradient. This is resolved by using a stiff and thick membrane. This membrane consists of flexible meanders, for easy movement between the two states. The device operates with an actuation voltage of 6.43 V, an insertion loss of -0.047 dB and isolation of -51.82 dB at 2 GHz.

Moving load response on the stresses produced in an irregular microstretch substrate

  • Kaur, Tanupreet;Sharma, Satish Kumar;Singh, Abhishek Kumar;Chaki, Mriganka Shekhar
    • Structural Engineering and Mechanics
    • /
    • v.60 no.2
    • /
    • pp.175-191
    • /
    • 2016
  • The present article is aimed at an investigation of stresses produced in a microstretch elastic half-space due to a moving load. The expressions of normal stress, shear stress and tangential couple stress produced in this case have been obtained in closed form. To find the displacement fields the perturbation method is applied. Significant effect of moving load on variation of stresses developed at different depths below the surface due to the depth of substrate and frictional coefficient of the rough surface of the medium has been observed. The effects of different shapes of irregularity and depth of irregularity on normal, shear and tangential couple stresses have been discussed. Some particular cases have also been deduced from the present investigation. Finally, the analytical developments have been illustrated numerically for aluminium-epoxy-like material substrate under the action of moving load.

Size-dependent dynamic stability of a FG polymer microbeam reinforced by graphene oxides

  • Wang, Yuewu;Xie, Ke;Fu, Tairan
    • Structural Engineering and Mechanics
    • /
    • v.73 no.6
    • /
    • pp.685-698
    • /
    • 2020
  • The dynamic stability of a functionally graded polymer microbeam reinforced by graphene oxides subjected to a periodic axial force is investigated. The microbeam is assumed to rest on an elastic substrate and is subjected to various immovable boundary restraints. The weight fraction of graphene oxides nanofillers is graded across the beam thickness. The effective Young's modulus of the functionally graded graphene oxides reinforced composite (FG-GORC) was determined using modified Halpin-Tsai model, with the mixture rule used to evaluate the effective Poisson's ratio and the mass density. An improved third order shear deformation theory (TSDT) is used in conjunction with the Chebyshev polynomial-based Ritz method to derive the Mathieu-Hill equations for dynamic stability of the FG-GORC microbeam, in which the scale effect is taken into account based on modified couple stress theory. Then, the Mathieu-Hill equation was solved using Bolotin's method to predict the principle unstable regions of the FG-GORC microbeams. The numerical results show the effects of the small scale, the graphene oxides nanofillers as well as the elastic substrate on the dynamic stability behaviors of the FG-GORC microbeams.