• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.034 seconds

THE BOND CHARACTERISTICS OF PORCELAIN FUSED BY TITANIUM SURFACE MODIFICATION (타이타늄의 표면개질에 따른 도재 결합 특성)

  • Choi, Taek-Huw;Park, Sang-Won;Vang, Mong-Sook;Yang, Hong-So;Park, Ha-Ok;Lim, Hyun-Pil;Oh, Gye-Jeong;Kim, Hyun-Seung;Lee, Kwang-Min;Lee, Kyung-Ku
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.169-181
    • /
    • 2007
  • Statement of problem: Titanium is well known as a proper metal for the dental restorations, because it has an excellent biocompatibility, resistance to corrosion, and mechanical property. However, adhesion between titanium and dental porcelains is related to the diffusion of oxygen to the reaction layers formed on cast-titanium surfaces during porcelain firing and those oxidized layers make the adhesion difficult to be formed. Many studies using mechanical, chemical and physical methods to enhance the titanium-ceramic adhesion have been actively performed. Purpose: This study meant to comparatively analyse the adhesion characteristics depending on different titanium surface coatings after coating the casts and wrought titanium surfaces with Au and TiN. Material and method: In this study, the titanium specimens (CP-Ti, Grade 2, Kobe still Co. Japan) were categorized into cast and wrought titanium. The wrought titanium was cast by using the MgO-based investment(Selevest CB, Selec). The cast and wrought titanium were treated with Au coating($ParaOne^{(R)}$., Gold Ion Sputter, Model PS-1200) and TiN coating(ATEC system, Korea) and the ultra low fusing dental porcelain was fused and fired onto the samples. Biaxial flection test was done on the fired samples and the porcelain was separated. The adhesion characteristics of porcelain and titanium after firing and the specimen surfaces before and after the porcelain fracture test were observed with SEM. The atomic percent of Si on all sample surfaces was comparatively analysed by EDS. In addition, the constituents of specimen surface layers after the porcelain fracture and the formed compound were evaluated by X-ray diffraction diagnosis. Result: The results of this study were obtained as follows : 1. The surface characteristics of cast and wrought titanium after surface treatment(Au, TiN, $Al_2O_3$ sandblasting) were similar and each cast and wrought titanium showed similar bonding characteristics. 2. Before and after the biaxial flection test, the highest atomic weight change of Si component was found in $Al_2O_3$ sandblasted wrought titanium(28.6at.% $\rightarrow$ 8.3at.%). On the other hand, the least change was seen in Au-Pd-In alloy(24.5at.% $\rightarrow$ 9.1at.%). 3. Much amount of Si components was uniformly distributed in Au and TiN coated titanium, but less amount of Si's was unevenly dispersed on Al2O3 sandblasting surfaces. 4. In X-ray diffraction diagnosis after porcelain debonding, we could see $Au_2Ti$ compound and TiN coating layers on Au and TiN coated surfaces and $TiO_2$, typical oxide of titanium, on all titanium surfaces. 5. Debonding of porcelain on cast and wrought titanium surface after the biaxial flection is considered as a result of adhesion deterioration between coating layers and titanium surfaces. We found that there are both adhesive failure and cohesive failure at the same time. Conclusion: These results showed that the titanium-ceramic adhesion could be improved by coating cast and wrought titanium surfaces with Au and TiN when making porcelain fused to metal crowns. In order to use porcelain fused to titanium clinically, it is considered that coating technique to enhance the bonding strength between coating kKlayers and titanium surfaces should be developed first.

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

Clinical study on the comparison of gold and zirconia wear in an implant-supported fixed prosthesis (임플란트 지지 고정성 보철물에서 금과 지르코니아의 마모 비교에 대한 임상 연구)

  • Kim, Jee-Hwan;Yang, Seung-Won;Oh, NamSik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.252-259
    • /
    • 2017
  • Purpose: The purpose of this study was to compare and analyze the wear of a prosthesis for 6 months after restoration with implant-supported fixed dental prosthesis made of either zirconia or gold. Materials and Methods: This study was conducted on patients requiring implant-supported fixed dental prostheses on first or second molar from January, 2015 to January, 2016. A total of 47 prostheses and antagonists were examined. Occlusal surface was recorded by impression of each prosthesis and antagonist 1 week and 6 months after prosthesis delivery. The digital files were created by impression scan. Occlusal shapes of 1 week and 6 months were compared and wear of prostheses and antagonists was analyzed. The Mann-Whitney test was used to analyzed the result data underwent normality test using SPSS (Version 23.0, IBM Corporation) Results: Mann-Whitney test revealed that there was no statistically significant difference in the median amount of mean vertical wear for 6 months in zirconia ($50.84{\mu}m$) and gold ($42.84{\mu}m$) prostheses (P > 0.05). When the opposing teeth were natural, the median amount of mean vertical wear of zirconia and gold prostheses was $47.72{\mu}m$ and $41.97{\mu}m$, respectively, and the median amount of mean vertical wear of enamel was $47.26{\mu}m$ and $44.59{\mu}m$, respectively. Statistical analysis showed no significant difference (P > 0.05). Conclusion: Despite the short study period and the small number of experimental groups, zirconia and gold showed no significant difference in wear during the first 6 months. Opposing natural enamel also showed no significant difference in the wear.

Precalcification Treatment of $TiO_2$ Nanotube on Ti-6Al-4V Alloy (Ti-6Al-4V 합금 표면에 생성된 $TiO_2$ 나노튜브의 전석회화 처리)

  • Kim, Si-Jung;Park, Ji-Man;Bae, Tae-Sung;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Statement of problem: Recently precalcification treatment has been studied to shorten the period of the implant. Purpose: This study was performed to evaluate the effect of precalcification treatment of $TiO_2$ Nanotube formed on Ti-6Al-4V Alloy. Material and methods: Specimens of $20{\times}10{\times}2\;mm$ in dimensions were polished sequentially from #220 to #1000 SiC paper, ultrasonically washed with acetone and distilled water for 5 min, and dried in an oven at $50^{\circ}C$ for 24 hours. The nanotubular layer was processed by electrochemical anodic oxidation in electrolytes containing 0.5 M $Na_2SO_4$ and 1.0 wt% NaF. Anodization was carried out using a regulated DC power supply (Kwangduck FA, Korea) at a potential of 20 V and current density of $30\;㎃/cm_2$ for 2 hours. Specimens were heat-treated at $600^{\circ}C$ for 2 hours to crystallize the amorphous $TiO_2$ nanotubes, and precalcified by soaking in $Na_2HPO_4$ solution for 24 hours and then in saturated $Ca(OH)_2$ solution for 5 hours. To evaluate the bioactivity of the precalcified $TiO_2$ nanotube layer, hydroxyapatite formation was investigated in a Hanks' balanced salts solution with pH 7.4 at $36.5^{\circ}C$ for 2 weeks. Results: Vertically oriented amorphous $TiO_2$ nanotubes of diameters 48.0 - 65.0 ㎚ were fabricated by anodizing treatment at 20 V for 2 hours in an 0.5 M $Na_2SO_4$ and 1.0 NaF solution. $TiO_2$ nanotubes were composed with strong anatase peak with presence of rutile peak after heat treatment at $600^{\circ}C$. The surface reactivity of $TiO_2$ nanotubes in SBF solution was enhanced by precalcification treatment in 0.5 M $Na_2HPO_4$ solution for 24 hours and then in saturated $Ca(OH)_2$ solution for 5 hours. The immersion in Hank's solution for 2 weeks showed that the intensity of $TiO_2$ rutile peak increased but the surface reactivity decreased by heat treatment at $600^{\circ}C$. Conclusion: This study shows that the precalcified treatment of $TiO_2$ Nanotube formed on Ti-6Al-4V Alloy enhances the surface reactivity.

The effect of copper alloy scaler tip on the surface roughness of dental implant and restorative materials (구리 합금 초음파 스케일러 팁이 치과 임플란트 및 수복 재료 표면에 미치는 영향)

  • Lee, Ah-Reum;Chung, Chung-Hoon;Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • Purpose: This study is designed to investigate the various impacts of different types of scaler tips such as cooper alloy base tip and the others on the surface roughness of teeth and implant by the method which is currently in clinical use. Materials and methods: Four different types of disc shaped porcelain, titanium, zirconia, and Type III gold alloy dental materials sized 15 mm diameter, 1.5 mm thickness were used for the experiment. Plastic hand curette (Group PS), cooper alloy new tip (Group IS), and stainless steel tip (Group SS) were used as testing appliances. A total of 64 specimens were used for this study; Four specimens for each material and appliance group. Surface roughness was formed with 15 degree angle in ultrasonic scaler tip and with 45 degree angle in hand curette of instrument tip and the specimen surface with 5 mm long, one horizontal-reciprocating motion per second for 30 seconds by 40 g force. To survey the surface roughness of each specimen, a field emission scanning electron microscope, an atomic force microscope, and a surface profiler were used. (Ra, ${\mu}m$). Results: According to SEM, most increased surface roughness was observed in SS group while IS groups had minimal roughness change. Measurement by atomic force microscope presented that the surface roughness of SS group was significantly greater than those of PS, IS and control groups in the type III gold alloy group (P<.05). IS group showed lesser surface roughness changes compared to SS group in porcelain and gold alloy group (P<.05). According to surface profiler, surface roughness of SS group showed greater than those of PS, IS and control groups and IS group showed lesser than those of SS group in all specimen groups. Type III gold alloy group had large changes on surface roughness than those of porcelain, titanium, zirconia (P<.05). Conclusion: The result of this study showed that newly developed copper alloy scaler tip can cause minimal roughness impacts on the surface of implant and dental materials; therefore this may be a useful alternative for prophylaxis of implant and restored teeth.

Comparison of Behavioral Response between Intranasal and Submucosal Midazolam Adminstration (소아 진정 치료 시 구강 점막 하와 비점막 Midazolam 투여의 행동 반응 비교)

  • Kim, Yun-Hee;Jung, Sang-Hyuk;Baek, Kwang-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.427-436
    • /
    • 2008
  • Purpose. The objective of this study was to evaluate the behavioral response and assess the effectiveness of additional intranasal (IN) and submucosal (SM) administration of midazolam during pediatric sedation for dental procedure. Material and methods. Thirty-three cases of healthy (ASAⅠ), uncooperative children aged from 24 to 72 month old at pediatric dental clinic of Ewha Womans University Hospital were selected for this study. Children received oral chloral hydrate 50 mg/kg with hydroxyzine 1.0 mg/kg. After waiting for 45 minutes, midazolam 0.2 mg/kg was administrated via IN route and via SM route randomly maintaining 50% of $N_2O$. A pulse oximeter and a capnograph were used for measuring vital signs ($SpO_2$, PR, RR, $EtCO_2$) throughout the sedation. Behavioral response was evaluated as Quiet (Q), Crying (C), Movement (M) or Struggling (S) in every 2 minutes for 40 minutes. Results. There were also no statistically significant differences in vital signs of the two groups. The behavioral response for the first ten minutes during sedation was a statistically significant difference (P < 0.05) between the two groups. After the first ten minutes, it was revealed that there was no significant difference. Conclusion. This study demonstrated that the addition of IN midazolam to the combination of oral chloral hydrate with hydroxyzine and nitrous oxide/oxygen inhalation is as safe and effective as that of SM midazolam in pediatric sedation for dental procedure.

  • PDF

A STUDY ON MICROLEAKAGE OF PREVENTIVE RESIN RESTORATION (예방적 레진수복의 미세누출에 관한 연구)

  • Koo, Hyun-Jung;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.504-511
    • /
    • 2001
  • Preventive resin restoration, extended concept of occlusal pit and fissure sealing, is procedure composed of as follows. Cavity preparation is limited to areas of initial caries The cavity is then restored with composite resin, while other sound pits and fissures are sealed with pit and fissure sealant. If pit and assure sealant with which microrestoration is possible is used, it may be of great benefit to both patient and operator in case of difficult-to-control children s treatment. However study on preventive resin restoration using this kind of materials have been scarce. The purpose of this study was to compare the microleakage of four different modes of preventive resin restoration. Restoration using only composite resin was compared together Fifty-five bicuspids were prepared with small class I cavity preparation on the occlusal surface, divided into the following groups and restored accordingly. Group 1 : Cavity was restored with Z-100 composite resin Group 2 : Cavity was restored with Z-100 composite resin. Pits and fissures were then sealed with Teethmate F-1 Group 3 : Cavity was restored with Z-100 composite resin Pits and fissures were then sealed with Ultraseal XT-plus Group 4 : Cavity and pits and fissures were restored with Ultraseal XT-plus altogrether Group 5 : Cavity was restored with Ultraseal XT-plus. Pits and fissures were then sealed with the same material. After restoration, the samples were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 30 seconds. After thermocycling, the samples were dipped into 1% methylene blue solution for 24 hours, then rinsed with tap water. The teeth were then embedded in resin and cut buccolingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage. The results were as follows : 1. Group 4 showed the greatest microleakage, while group 3, showed the least. The mean microleakage decreased in the following order:4>1>5>2>3. 2. There was no stastically significant difference between group 1 and group 5(p>0.05). However, group 1 showed significantly greater microleakage compared to group 2 and 3(p<0.05) Group 1 showed significantly less microleakage compared to group 4(p<0.05). 3. Group 2 showed no statistically significant difference compared to group 3(p>0.05). However group 2 showed significantly less microleakage compared to group 4 and 5(p<0.05) 4. Group 3 showed significantly less microleakage compared to group 4 and 5(p<0.05). 5. Group 5 showed significantly less microleakage than group 4(p<0.05).

  • PDF

The Use of Autogenous Periosteal Grafts for the Periodontal Regeneration in Mandibular Class II Furcation Defects in the Dog (성견의 2급 치근 분지부 결손에서 자가골막 이식에 의한 치주조직 재생)

  • Nam, Seung-Ji;Chung, Hyun-Ju;Kim, Young-Jun
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.241-257
    • /
    • 2000
  • Autogenous periosteal grafts are an attractive alternative to existing barrier membrane materials since they meet the reqiurements of an ideal material. But no histological data are available on the effectiveness of periosteal membranes in the treatment of periodontal defects. The purpose of this study was to evaluate effect of autogenous periosteal graft on periodontal regeneration histologically. Class II furcation defects were surgically created on the second, third and the fourth premolars bilaterally in the mandibules of six mongrel dogs. The experimental sites were divided into three groups according to the treatment modalities; control group - surgical debridement only; Group I- autogenous periosteal membrane placement after surgical debridement; Group II-autogenous periosteal membrane placement after surgical debridement and bone grafting. The animals were sacrificed at 2, 4 and 12 weeks after periodontal surgery and the decalcified and undecalcified specimens were prepared for histological and histometrical analysis. Clinically all treated groups healed without significant problems. Under light microscope, at 2 weeks, control group showed significant apical epithelial migration and bone remodelling only below the notch area. But for the group I, II with autogenous periosteal graft, less apical migration of epithelium appeared and large amount of osteoid tissue showed above the notch area. Grafted periosteal membrane was indiscernable at 4 weeks, so periosteal membrane might be organized to surrounding tissues. Histometrically, at 4 and 12 weeks, all the test and control groups didn't show significant change of epithelial zone but new attachment level tended to be gained in the test groups than control group. These results suggest that autogenous periosteal grafts should be a good alternative for guided tissue regeneration.

  • PDF

An assessment of statistical errors of articles in the Journal of Korean Academy of Prosthodontics: Comparison between Korean version and English version (대한치과보철학회지에 게재된 논문의 통계적 오류: 국문논문과 영문논문의 비교)

  • Park, Dong-Gyu;Choi, Yong-Geun;Kim, Young-Su;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.273-285
    • /
    • 2009
  • Statement of problem: The aim of dental research is to advance scientific knowledge and leads to improvement in the treatment and prevention of dental disease. Utilizing an effective research design and adequate statistical methods are essential procedures ensuring that the results of researches are based on evidences. A research should utilize proper statistical methods without statistical errors; Otherwise, it could adversely affect clinical practice and future research. Purpose: This study was made to investigate the statistical methods used in the Journal of Korean Academy of Prosthodontics (JKAP) and then to assess them for the statistical errors. Material and methods: Among the total of 399 articles in the JKAP published from 2000 to 2006, 292 articles using statistics were reviewed. The validity of the statistical methods used in them were assessed using a checklist based on the guideline for statistical reporting in the uniform requirements for manuscripts submitted to biomedical journals by International Committee of Medical Journal Editors. The checklist consisted of three categories of statistical errors: 1) Unspecified computer statistical packages, 2) Inadequate description of statistical methods, 3) Misuse of statistical terms. Then, the results were compared between the Korean version and the English version in the JKAP. Results: Among the 212 articles using statistics in the Korean version, 115 articles (54%) and among the 80 articles using statistics in the English version, 47 articles (59%) were shown to have unspecified computer statistical packages without statistically significant difference (P = .66). Likewise, 101 articles (48%) in the Korean version and 25 articles (31%) in the English version were shown to have the inadequate description of statistical methods without statistically significant difference (P = .09). However, 114 articles (54%) in the Korean version and 19 articles (24%) in the English version were shown to have the misuse of statistical terms with statistically significant difference (P = .01). Conclusion: Some of the articles in the JKAP had inadequate statistical validity, given the statistical errors identified in this assessment. Hence, dental researchers should be more careful when it comes to describing and applying statistical methods.

Finite element analysis of peri-implant bone stress influenced by cervical module configuration of endosseous implant (임플란트 경부형상이 주위골 응력에 미치는 영향에 관한 유한요소법적 분석)

  • Chung, Jae-Min;Jo, Kwang-Heon;Lee, Cheong-Hee;Yu, Won-Jae;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.394-405
    • /
    • 2009
  • Statement of problem: Crestal bone loss, a common problem associated with dental implant, has been attributed to excessive bone stresses. Design of implant's transgingival (TG) part may affect the crestal bone stresses. Purpose: To investigate if concavely designed geometry at a dental implant's TG part reduces peri-implant bone stresses. Material and methods: A total of five differently configured TG parts were compared. Base model was the ITI one piece implant (Straumann, Waldenburg, Switzerland) characterized by straight TG part. Other 4 experimental models, i.e. Model-1 to Model-4, were designed to have concave TG part. Finite element analyses were carried out using an axisymmetric assumption. A vertical load of 50 N or an oblique load of 50 N acting at $30^{\circ}$ with the implant's long axis was applied. For a systematic stress comparison, a total of 19 reference points were defined on nodal points around the implant. The peak crestal bone stress acting at the intersection of implant and crestal bone was estimated using regression analysis from the stress results obtained at 5 reference points defined along the mid plane of the crestal bone. Results: Base Model with straight configuration at the transgingival part created highest stresses on the crestal bone. Stress level was reduced when concavity was imposed. The greater the concavity and the closer the concavity to the crestal bone level, the less the crestal stresses. Conclusion: The transgingival part of dental implant affect the crestal bone stress. And that concavely designed one may be used to reduce bone stress.