• 제목/요약/키워드: crack-repair

검색결과 285건 처리시간 0.027초

터널 콘크리트 구조물 균열에 에폭시 주입의 표준화에 대한 기초적 연구 (A basic study on the standardization of epoxy injection in cracks of tunnel concrete structures)

  • 백종명;장석재
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1235-1240
    • /
    • 2005
  • In this status no inspection standard of quality in repair of present concrete structure has a problem to repair for simple experience. In this paper for this problem improvement, it made an analysis of relation to injection quantity of crack width, injection time of crack width, injection pressure of crack width, injection pressure and time, injection quantity of structural size, injection quantity of structural individual crack position, injection time about crack width. and structural thickness. The data gained in analysis result be judged that it will help in systematic quality control about concrete structural repair.

  • PDF

공동주택 층간균열의 하자판정 및 보수공법 적용에 대한 개선방안 (Improvement Measures for the Defect Determination and the Application of Repair Method for Interlayer Cracks in Apartment Houses)

  • 최상진;신만중
    • 한국건설관리학회논문집
    • /
    • 제23권5호
    • /
    • pp.23-33
    • /
    • 2022
  • 공동주택의 하자소송 금액에서 가장 많은 비율을 차지하고 있는 균열하자는 하자판정 기준이 명확하지 않아 판결에 따라 하자에 관한 판단이 엇갈리고 있다. 균열하자 판결금액 대부분을 차지하는 층간균열은 균열의 폭이나 상태와 관계없이 모두 하자로 판정되는 추세이며, 보수공법 또한 대부분 일률적으로 정해지고 있다. 이는 균열하자 판정의 기준이 되는 국토교통부의 하자판정기준과 법원에서 기준을 삼는 건설감정실무의 기준이 일치하는 않는 문제에서 출발한다. 법령의 개정과 법원감정실무지침서의 개정 등을 통해 모든 이해관계자가 적용할 수 있는 하자판정 기준의 수립이 필요하다. 또한, 층간균열 보수공법 기준은 층간균열의 폭과 상태에 따라 공법을 적용할 필요성이 있다. 균열에 대한 하자판정과 보수공법적용을 합리화한다면 소송에만 의존하는 현재의 하자분쟁 추세를 바꿀 수 있는 계기가 될 수 있을 것이다.

보수된 균열을 가진 두꺼운 평판의 피로균열 성장 거동에 관한 실험적 연구 (A Experimental Study on the Fatigue Crack Growth Behavior of Thick Plate with Repaired Crack)

  • 정기현;양원호;김철;성기득
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.292-298
    • /
    • 2001
  • An experimental investigation of the effect of composite patching repair was conducted to characterize the fatigue crack growth behavior in thick A16061-T6 (6mm) panels with single bonded patch by fiber reinforced composite patch. Four patch lengths and no patch plate were examined. An analytical procedure, involving three-dimensional finite element method having three layers to model cracked aluminum plate, epoxy by adhesive and composite patch, is calculated the stress intensity factors. From the calculated stress intensity factors, the fatigue crack growth rates are obtained. At the single patching type, different fatigue crack growth ratios through the plate thickness were investigated by using the experimental and analytical results. The results demonstrated that there was a definite variation in fatigue life depending on the size of composite patch. While crack reached the patch end, retardation of crack growth was also revealed in the bonded repair.

  • PDF

터널 콘크리트 구조물의 보수를 위한 무기계 균열주입기술의 표준화 연구 (Standardization of Injection System by Inorganic Materialfor Crack Repair of Tunnel Concrete Structures)

  • 배기선;곽수정;백종명
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권6호
    • /
    • pp.191-197
    • /
    • 2006
  • 본 논문은 터널 콘크리트 구조물의 보수를 위한 무기계 균열주입기술의 표준화에 관한 연구이다. 본 연구를 위하여 균열보수공사가 필요한 터널 라이닝 및 박스 구조물을 선정하여, 균열폭에 따른 주입량, 주입시간 및 주입압력, 주입압력과 주입시간, 구조물 규모에 따른 주입량, 구조물별 균열 위치에 따른 주입량, 균열폭 및 구조물 두께와 주입시간의 관계에 관하여, 현장 조사와 시험평가를 수행하여 구조물의 종류 및 균열의 크기에 따른 균열보수재의 주입압력, 주입량 및 주입시간 등을 명확히 파악하였다.

Fatigue Behavior of Cracked Al 6061-T6 Alloy Structures Repaired with Composite Patch

  • Yoon, Young-Ki;Park, Jong-Joon;Kim, Guk-Gi;Yoon, Hi-Seak
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권3호
    • /
    • pp.5-10
    • /
    • 2001
  • Due to the development of high-strength fibers and adhesives, it is now possible to repair cracked metallic plates by bonding reinforced patches to the plate over the crack. In this study, pre-cracked aluminum 6061-T6 alloy plates repaired with bonded carbon/epoxy composite patch are applied to investigate the effect of various patch shapes on the tensile strength and the fatigue behavior of the structure. A non-patch-boned cased and 2 type-50$\times$50, 40$\times$20 mm-composite patch-bonded cases were tested to obtain fracture loads and fatigue crack growth rate. The results showed that the patch-bonded repair improves the static strength by 17% and the fatigue life by 200% compared to non-repaired case. It means that patch-boned repair is more effective in the fatigue life. It was also revealed that the patching method along crack growth direction is more efficient in cost and weight reduction. By observing the fractography, patch-bonded repair specimens demonstrated zigzag fracture patterns compared with the non-patched specimens, which shows a typical ductile fracture.

  • PDF

복합재료 보강재로 보수되어진 균열을 가진 두꺼운 평판의 피로균열 성장에 관한 연구 (A Study on Fatigue Crack Growth of Composite Patching Repaired on Cracked Thick Plate)

  • 정기현;양원호;고명훈
    • 대한기계학회논문집A
    • /
    • 제25권12호
    • /
    • pp.2070-2077
    • /
    • 2001
  • An experimental investigation of the effect of composite patching repair was conducted to characterize the fatigue crack growth behavior in thick A16061-T6 (6mm) panels with single bonded patch by fiber reinforced composite patch. Four patch lengths and no patch plate were examined. An analytical procedure, involving three-dimensional finite element method having three layers to model cracked aluminum plate, epoxy by adhesive and composite Patch, is calculated the stress intensity factors. From the calculated stress intensity factors, the fatigue crack growth rates are obtained. At the single patching type, different fatigue crack growth ratios through the palate thickness were investigated by using the experimental and analytical results. The results demonstrated that there was a definite variation in fatigue life depending on the size of composite patch. While crack reached the patch end, retardation of crack growth was also revealed in the bonded repair.

가스터빈 고온부품의 재생 접합을 위한 손상부 파악 (The Consideration of the Damage in Gas Turbine Hot Parts for Repair Bonding Process)

  • 김성욱;최철;김재철;이창희
    • 동력기계공학회지
    • /
    • 제7권2호
    • /
    • pp.73-79
    • /
    • 2003
  • The present study was aimed at analysing the damage of a used gas turbine bucket after 39,500h of total service. Microstructures and cracks of service-induced bucket were observed. The crack might have initiated from the coating in the bucket surface by thermal fatigue and propagated into the GTD111 base metal. Maximum depth of penetration was 2.7 mm(full penetration) at the leading edge. Crack contains a lot of Cr-,Ti-,Al-oxide which will prohibit filling and wetting of insert metal. Depth and propagation direction of crack were accorded with centrifugal force and temperature distribution in turbine bucket. Present result will provide basic data for repair bonding process.

  • PDF

직접 에너지 적층 공정을 이용한 보수 공정에서 보수 폭에 따른 기계적 특성 관찰 (Effect of Repair Width on Mechanical Properties of 630 Stainless Steel Repaired by Direct Energy Deposition Process)

  • 오욱진;신광용;손용;심도식
    • 한국기계가공학회지
    • /
    • 제19권3호
    • /
    • pp.42-50
    • /
    • 2020
  • This study explores the effects of repair width on the deposition characteristics and mechanical properties of stainless steel samples repaired using direct energy deposition (DED). In the DED repair process, defects such as pores and cracks can occur at the interface between the substrate and deposited material. In this study, we changed the width of the pre-machined zone for repair in order to prevent cracks from occurring at the inclined surface. As a result of the experiment, cracks of 10-40 ㎛ in length were formed along the inclined slope regardless of the repair width. Yield and tensile strength decreased slightly as the repair width increased, but the total and uniform elongation increased. This is due to the orientation of the crack. For specimens with a repair width of 20 mm, yield and tensile strength were 883 MPa and 1135 MPa, respectively. Total and uniform elongations were 14.3% and 8.2%, respectively. During observation of the fracture specimens, we noted that the fracture of the specimen with an 8 mm repair width occurred along the slope, whereas specimens with 14 mm and 20 mm repair depths fractured at the middle of the repaired region. In conclusion, we found that tensile properties were dependent upon the repair width and the inclination of the crack occurred at the interface.

균열이 발생된 콘크리트의 특성 및 보수.보강(구조 및 재료 \circled2) (Properties and Repair-Reinforcement of Concrete Introduced Crack)

  • 김영익;윤준노;민정기;김경태;박필우;성찬용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.284-289
    • /
    • 2000
  • This study is performed to evaluate an the crack properties and repair-reinforcement of concrete introduced crack. Materials used are portland cement, coarse aggregate, fine aggregate, unsaturated polyester resin and fly ash. Specimen is used beam of 76${\times}$76${\times}$412mm for measurement of pulse velocity, dynamic modulus of elasticity and bending strength and is introduced crack artificially. The following conclusions are drawn; Pulse velocity, dynamic modulus of elasticity and bending strength of concrete introduced crack is shown the lower 1.24∼11.91%, 3.42∼17.21% and 38.17∼61.0% than that of the control concrete, respectively. Pulse velocity, dynamic modulus of elasticity and bending strength of concrete repaired and reinforced crack is shown the higher 0.5∼2.60%, 1.57∼3.07% and 28.17∼47.25% than that of the concrete introduced crack and the lower than that of the control concrete, respectively.

  • PDF

폴리머 디스퍼전과 시멘트로 만든 균열보수용 폴리머 시멘트 복합체의 기초적 성질 (Basic Properties of Polymer Cement Composites with Polymer Dispersions and Cement for Crack Repair )

  • 조영국
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권5호
    • /
    • pp.97-104
    • /
    • 2023
  • 본 연구는 RC 구조물의 균열보수를 위한 보수재로서 폴리머 디스퍼전과 시멘트만으로 구성된 폴리머 시멘트 복합체 (polymer cement Composites ; PCCs)를 제작하여 실험적으로 기초물성을 파악하고자 하였다. 연구를 위한 시험배합은 EVA 및 SAE 폴리머 디스퍼전을 기반으로 보수재의 충전성을 고려하여 폴리머 시멘트비를 4가지(20, 60, 80 및 100%)로 변환시키면서 물시멘트비를 정해 PCCs의 점도를 결정하였다. 또한 PCCs의 강성을 개선시키기 위하여 P/C 80%와 100%에 실리카퓸을 혼입한 시험편도 제작하였다. PCCs의 균열보수용으로서의 점도, 유동성, 충전성, 인장강도, 신장률 및 탄성계수 등 기초적 물성을 실험하였다. 연구결과, 폴리머의 종류에 따라 P/C는 점도와 유동성에 큰 영향을 미쳤으며 RC 구조물의 균열보수용으로서 충전성을 고려한 적절한 점도를 맞춘 배합설계를 위해 상당한 가수가 필요하였다. 본 연구에서 설계한 모든 배합은 충전성이 우수하였으며, PCCs의 인장강도와 신장률은 시멘트 혼입 폴리머계 방수재에 대한 KS 규정을 만족하였다. 또한 실리카퓸을 혼입함으로써 PCCs의 인장강도와 탄성계수가 개선되었으며, 폴리머 종류에 따라서는 SAE를 사용한 경우가 EVA를 사용한 경우에 비해 RC 구조물 균열 보수재로서 우수한 기초적인 물성을 나타냈다. 본 연구결과를 종합하면, RC 구조물의 균열보수용으로 SAE를 사용한 P/C 80% 또는 100%와 실리카퓸 30%까지 혼입한 배합을 적절한 배합으로 제안할 수 있었다.