• 제목/요약/키워드: construction-standard-production-rate

검색결과 30건 처리시간 0.026초

탄소제로 빌딩을 위한 전력변환 제어 (Power conversion control for zero emission buildings)

  • 한석우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.504-505
    • /
    • 2011
  • Decreasing actual greenhouse gas will be difficult if it is not solved addressed in architectural fields. Zero emission building or zero energy building, maximize the efficiency of energy, which means the building can operate by their own renewable energy facility without any other supplying. To be a zero emission building, a building needs realization of high efficiency low energy consumption, construction of building its own energy production facilities and lastly a power grid connection. According to increasing of DC load about TV, LED lighting, computer, IT in building for living and business, it is expected the save of energy when the system of AC power distribution change into the system of DC power distribution. Renewable energy exists a big different rate produced by outside environment. When electrical power overproduce, it can supply for system. Otherwise, if electrical power produce less, it can receive supply from system. Send and receive power can lead to zero to annual standard. This paper shows the simulation about efficient control of power conversion which is related to DC power distribution of architecture and DC output of renewable energy by using L-type converter.

  • PDF

도로의 축광차선 도료 개발을 위한 축광안료 최적 배합비 산정에 관한 연구 (Determination of Optimal Mixing Ratio of Phosphorescent Pigment to Develop Phosphorescent Paint for Road Line Marking)

  • 이영문;김상태;김흥래
    • 한국도로학회논문집
    • /
    • 제17권5호
    • /
    • pp.67-73
    • /
    • 2015
  • PURPOSES : This study was conducted to derive the optimum mixing ratio of phosphorescent pigment for the development of phosphorescent line marking. METHODS: In this study, we utilized a literature review and case study methodology, to describe the domestic and foreign state of practice for the production and mixing of phosphorescent pigment for use in line marking. The optimal mixing ratio was derived by comparing the reduction in luminance over time for the various phosphorescent pigment mixing ratios identified in the literature. In addition, performance and construction characteristics were analyzed using field testing techniques. RESULTS : The results were as follows: 1) the results of the luminance performance standards tests showed that all of the phosphorescence test specimens satisfied the phosphorescent fire protection standard. As the phosphorescent pigment mixing ratio increased, the luminance value increased, 2) the luminance reduction rate was minimum at the mixing ratio of 50%. However, when compared to a mixing ratio 40%, a small difference was recorded, the luminance reduction rate from the mixing ratio of 40% is judged as being converged. Therefore, in view of the economic efficiency, it was determined that the optimal mixing ratio was 40%, 3) as a result of construction on the field, a mixing ratio of 40% was found to have a higher luminance value than the general line marking for up to three hours after sunset, 4) it was found that the phosphorescent line markings without glass beads spraying had a higher luminance value than the phosphorescent line markings with glass beads spraying. CONCLUSIONS : Through the results of the basic experiments of the line markings obtained by blending a phosphorescent pigment, the results could be applied to play an important role in the development of phosphorescent line marking paint technology and in establishing application planning for on-site construction characteristics.

EtherCAT 통신방식을 응용한 IEEE 802.15.4 Ad-Hoc 무선 센서 네트워크 라우팅 방식 (IEEE 802.15.4 Ad-Hoc Wireless Sensor Network Routing Method Applying EtherCAT Communication Method)

  • 박정현;서창준
    • 전기전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.289-301
    • /
    • 2018
  • IoT 기술을 산업현장에 적용시킨 IIoT는 생산율 향상 및 작업자의 안전을 위한 모니터링의 기술로 이용되고 있다. 하지만 수십에서 수백 대의 공작기계가 부품을 가공하고 있는 생산라인에 Ethernet과 RS485 등을 유선 네트워크를 이용한 IIoT 네트워크의 구축을 통한 모니터링은 기반비용 및 네트워크의 유연성 및 유동성의 문제를 가진다. 이로 인해 유선 네트워크에서 무선 네트워크로의 변화가 필요한 실정이다. 따라서 본 논문에서는 IEEE 802.15.4 표준 무선네트워크 디바이스를 이용하여 생산라인에 Ad-Hoc WSN를 구축한다. 또한 추가적으로 Payload Frame을 모든 센서노드가 공유하는 특징을 가지는 EtherCAT 통신방식을 이용하여 센서노드의 전송주기 및 순서를 설정하였다. 이를 통해 무선 센서 네트워크의 패킷충돌로 인한 신뢰성 저하와 실시간성 문제를 해결했으며 실제 산업현장에 사용할 수 있는 무선 네트워크 라우팅 방식을 확인하였다.

포항지역 학교급식의 안전성을 위한 학교 급식 조리실의 기본 시설.설비 조사 (Analysis on Facilities & Basic Equipment of School Foodservice Safety in Pohang area)

  • 윤미연;이인숙
    • 대한영양사협회학술지
    • /
    • 제12권3호
    • /
    • pp.264-276
    • /
    • 2006
  • The purpose of this study was to propose HACCP system implementation properly and to secure the food safety of school foodservices in Pohang city since the proper facilities and equipment should be key factors in food safety and production. So this study was designed to evaluate existing equipment in food production area, receiving and dining area, and employee facilities. Questionnaire was mailed to 107 school foodservice dietitians in Pohang area and 97 were responded (90.7% response rate). Approximately sixty percent of foodservices were not available separate receiving or polluted area, fifty one percent were installed screen door for insecticidal and temperature and humidity control, and these environmental conditions were hard to keep kitchen dry and sanitary condition. Usually public schools were better equipped than private schools. Forty three percent of school foodservice had initial use of non-foodservice, opened before 1994, and thirty three percent of elementary school foodservice. Among employee facilities, hand washing sanitation stand was prepared seventy nine percent (78.9%) of school foodservices. Dietitians chose outworn equipment and facilities (30.9%), difficulties of maintaining standard temperature and humidity for foodservice (20.6%), lacking separate receiving or polluted area (13.4%), indirect contamination of water hoss (10.3%), and lacking employee facilities (10.3%) as critical points to correct in school foodservice. Therefore governmental regulating agencies must review and approval of plans prior to new construction or extensive remodeling of school foodservice facilities. In addition to these requirement, plan must be set-up step by step to implement HACCP system properly.

  • PDF

습도환경에서 두께와 도장재별 MDF의 평탄도 유지방안에 대한 연구 (A Study on the Scheme to Maintain the Flatness of MDF According by painting and by thickness to the Environment Humidity)

  • 정재은
    • 한국실내디자인학회논문집
    • /
    • 제16권5호
    • /
    • pp.98-106
    • /
    • 2007
  • With the recent increase in the amount of interior materials, the medium-density fiberboard(MDF) has continued to be produced at an increasing rate. Accordingly, to prevent the deformation of MDF after its construction, secure the precision of its finishing and improve the performance of its design, this study attempted to investigate the effect of environment humidity conditions on flatness according to the field used in MDF and its relationship to other physical properties. An attempt was made to conduct this study by changing the conditions of surface treatment by moisture and by thickness. For this purpose, it is judged that it is desirable to prevent scheme to maintain the flatness by defining the coefficient of water absorption-induced length change as in the regulation on low-density soft fiberboard and adjusting the standard for wet bending strength upward. It is thought that is further studies will be conducted about the effect of material, adhesive and thermal pressure condition, production system and processing method used in MDF on its scheme to maintain the flatness and changes in length and thickness expansion.

관 부설 및 접합공사 공사비산정기준 개선에 관한 연구 (A Study on the Improvement of Construction Cost Standards for Pipe Laying and Joining Work)

  • 오재훈;안방율
    • 한국산학기술학회논문지
    • /
    • 제21권7호
    • /
    • pp.675-684
    • /
    • 2020
  • 노후 인프라로 인한 각종 안전사고 발생과 수질관리 등으로 인하여 상·하수도 관에 대한 공사가 전국적으로 활발하게 진행 되고 있다. 하지만 현장에서는 공사비적용에 있어, 공사비기준의 개정내용을 분석하는 연구나 자료가 없어 어려움을 겪고 있다. 따라서, 본 연구에서는 관 부설 및 접합공사의 공사비산정을 위한 기준현황과 현장조사내용, 개정사항을 분석하였다. 주요 개정요인으로는 시공범위의 불분명, 시설물유형에 따른 배관 재질 적용한계, 보통인부 중심의 인력구성, 인력부설의 한계, 공구손료 및 기계경비 계상기준 미비로 분석되었다. 실제 현장조사를 통해 관종별 특징을 정하여 구분하였고, 양중장비와 경장비의 투입현황 등을 파악하였다. 또한, 관부설과 병행되는 터파기 및 검측에 대한 작업내용, 기능공 투입실태를 조사하였다. 그 결과, 공통사항의 신설을 통한 작업범위의 명확화, 관 재질별 편제구성, 기능공 중심의 인력비율 조정, 기계경비의 계상근거를 마련하였다. 더불어 관의 유지관리를 위한 관 세척 기준을 제정하였으며, 주기개정을 통한 곡관, 이형관의 계상기준을 명확히 하였다. 이러한 개정결과로 인한 공사비영향성을 분석한 결과 사업별로 약 1.28%의 공사비 절감효과가 나타났다.

125 MW급 우드펠릿 발전소에서 탈질설비 운전조건이 질소산화물 발생량에 미치는 영향 (Effect of the De-NOx Facility Operating Condition on NOx Emission in a 125 MW Wood Pellet Power Plant)

  • 전문수;이재헌
    • 플랜트 저널
    • /
    • 제18권3호
    • /
    • pp.52-61
    • /
    • 2022
  • 본 연구는 실제 운영중인 영동에코발전본부 1호기 125 MW 우드펠릿 발전소를 대상으로 탈질설비 운전조건이 NOx 발생량에 미치는 영향을 시험하였다. SNCR 요소 유량 증가에 따라 NOx 농도는 점차 감소하였으나 SCR 후단 암모니아 슬립은 상승하였다. 시험대상 보일러는 고온의 내부온도로 인해 SNCR 운영에 불리한 구조이며 노즐의 최적위치 검토가 필요할 것이다. SCR 희석공기 온도변화는 NOx 발생량에 영향을 미치지 않았다. SCR 암모니아 유량 증가는 SCR 후단 NOx 농도를 감소시켰고 NOx 제거효율도 증가시켰다. 다만 암모니아 슬립 자체 기준치를 초과하지 않는 암모니아 유량 111 kg/h가 최대 운전기준으로 추정된다. SCR 믹서 압력 상승은 NOx 농도를 감소시키고 제거효율도 최대로 측정되어 NOx 생성을 가장 효과적으로 억제하는 변수로 파악되었다.

  • PDF

해상풍력 발전용 타워 제작시 고장력강재의 초층용접에 관한 용접특성 연구 (Study of Welding Toughness Characteristics on the Root-pass Welding Process of High Tensile Steel at Tower Production for Offshore Wind Power Generation)

  • 정성명;김일수;김지선;나현호;이지혜
    • 한국생산제조학회지
    • /
    • 제21권2호
    • /
    • pp.349-353
    • /
    • 2012
  • As the world wind energy market grows rapidly, the productions of wind power generation equipment have recently increased, but manufacturers are not able meet this requirement. Particularly offshore wind energy industry is one of the most popular renewable energy sectors. To generalize welding processes, the welding automation is considered for steel structure manufacturing in offshore wind energy to get high quality and productivity. Welding technology in construction of the wind towers is depended on progress productivity. In addition, the life of wind tower structures should be considered by taking account of the natural weathering and the load it endures. The root passes are typically deposited using Gas Tungsten Arc Welding(GTAW) with a specialized backing gas shield. Not only the validation consists of welders experienced in determining the welding productivity of the baseline welding procedure, but also the standard testing required by the ASME section IX and API1104 codes, toughness testing was performed on the completed field welds. This paper presents the welding characteristics of the root-pass welding of high tensile steel in manufacturing of offshore wind tower. Based on the result from welding experiments, optimal welding conditions were selected after analyzing correlation between welding parameters(peak current, background current and wire feed rate) and back-bead geometry such as back-bead width(mm) and back-bead height performing root-pass welding experiment under various conditions. Furthermore, a response surface approach has been applied to provide an algorithm to predict an optimal welding quality.

코팅된 제올라이트 비드를 이용한 콘크리트 투수블록의 대기전구물질 제거율 평가 (Air Pollutant Removal Rates of Concrete Permeable Blocks Produced with Coated Zeolite Beads)

  • 박준서;양근혁
    • 한국건축시공학회지
    • /
    • 제23권2호
    • /
    • pp.153-164
    • /
    • 2023
  • 이 연구의 목적은 황산화물(SOx) 및 질소산화물(NOx)을 제거할 수 있는 소재를 코팅한 제올라이트 비드를 이용하여 제조된 콘크리트 투수블록의 대기전구물질의 제거율을 평가하는데에 있다. 대기전구물질인 SOx와 NOx를 제거하기 위해서 사용된 소재는 이산화티타늄(TiO2) 분말과 야자각 분말이며, 이 두 소재를 제올라이트 비드에 코팅하였다. 시편은 실제 공장생산라인을 이용하여 제올라이트 비드가 임베디드된 콘크리트 투수블록을 제작하였다. 실험결과 표층에서 야자각 분말로 코팅된 제올라이트 비드가 첨가된 콘크리트 투수블록의 SOx와 NOx 제거율은 각각 12.5% 및 99%로서 다른 블록보다도 우수한 성능을 발휘하였다. 또한, 휨 강도 및 미끄럼저항성은 각각 5.3MPa 및 65BPN 이상으로 KS F 4419 및 KS F 4561에서 제시된 값을 만족하였다. 반면, 투수계수는 서울특별시의 투수블록 포장 설계, 시공 및 유지관리 기준으로 협잡물 오염 전후에 각각 3 및 4등급으로 낮은 투수성을 보였다. 결과적으로 표층에서 야자각 분말로 코팅된 제올라이트 비드의 첨가는 충분한 휨강도 및 미끄럼저항성을 확보하면서 자외선에 관계없이 SOx와 NOx를 동시에 제거할 수 있지만, 투수성이 낮으므로 이에 대한 보완이 필요하다.

골재에 포함된 토분의 현황 조사 및 콘크리트의 성능에 미치는 영향 (The Status of Clay Minerals in Aggregates and Their Effect on the Concrete Performance)

  • 김인;한민철
    • 한국건축시공학회지
    • /
    • 제24권4호
    • /
    • pp.393-402
    • /
    • 2024
  • 토분에 대한 기준은 한국산업표준(KS)의 KS F 2527(콘크리트용 골재)에서 규정하고 있지 않으며 명확한 품질기준과 시험방법이 없으며 학계 및 산업계의 관련 연구도 부족한 상황이다. 또한 골재를 생산하는 업계와 사용하는 업계등 실무에서는 토분 문제가 경제성과 직결됨으로 운영상 관리가 되지 않는 실정이다. 따라서 본 연구에서는 골재 토분 문제에 대한 현황 및 관련 기준, 발생원인을 조사하고 토분이 콘크리트에 미치는 영향에 대해 연구 한 결과 토분의 화학적 조성은 점토에서 흔히 조성되는 Al2O3, Fe2O3, SiO2로 나타났으며 XRD 분석결과 흡수성이 높은 몬모릴나이트와 일라이트 광물로 구성되어 있는 것으로 확인하였다. 또한 국내·외 토분의 품질규정 조사결과 KS F 2527(콘크리트용 골재)에서 제시하고 있는 밀도 및 흡수율은 토분의 함유량의 어느 정도에 대하여 간접적으로 유추해 볼 수 있는 수치에 불과한 실정이다. 또한 토분이 콘크리트의 성능에 미치는 영향을 분석한 결과 토분의 첨가량이 증가함에 따라 콘크리트의 유동성을 확보하기 위해서는 단위수량 증가가 필요하며 이로인해 압축강도 또한 감소 되는 것으로 사료된다.