• Title/Summary/Keyword: center symmetry

Search Result 255, Processing Time 0.024 seconds

Sensitivity of quantitative symmetry measurement algorithms for convergent beam electron diffraction technique

  • Hyeongsub So;Ro Woon Lee;Sung Taek Hong;Kyou-Hyun Kim
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.10.1-10.9
    • /
    • 2021
  • We investigate the sensitivity of symmetry quantification algorithms based on the profile R-factor (Rp) and the normalized cross-correlation (NCC) coefficient (γ). A DM (Digital Micrograph©) script embedded in the Gatan digital microscopy software is used to develop the symmetry quantification program. Using the Bloch method, a variety of CBED patterns are simulated and used to investigate the sensitivity of symmetry quantification algorithms. The quantification results show that two symmetry quantification coefficients are significantly sensitive to structural changes even for small strain values of < 1%.

A vision algorithm for finding the centers of steam generator tubes using the generalized symmetry transform (일반화 대칭변환을 이용한 원전 증기발생기 전열관 중심인식 비젼 알고리즘)

  • 장태인;곽귀일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1367-1370
    • /
    • 1997
  • This paper presents a vision algorithm for finding the centers of steam generator tubes using the generalized symmetry transform, which is used for ECT(Eddy Current Test) of steam generator tubes in nuclear power plants. The geometrical properties of the image representing steam generator tubes shows that they have amost circular or somewhat elliptic appearances and each tube has strong symmetry about its center. So we apply the generalized symmetry transform to finding centers of steam geneator tubes. But applying the generalized symmetry transform itself without any modification gives difficulties in obtaining the exact centers of steam generator tubes. But applying the generalized symmetry transform itself without any modification gives difficulties in obtaining the exact centers of tubes due to the shadow effect generated by the local light installed inside steam generator. Therefore we make the generalized symmetry transform modified, which uses a modified phase weight function in getting the symmetry magnitude in order to overcome the misleading effect by the local light. The experimental results indicate that the proposed vision algorithm efficiently recongnizes centers of steam generator tubes.

  • PDF

Lateral Symmetry of Center of Pressure During Walking in Patients With Unilateral Knee Osteoarthritis

  • Kim, Si-hyun;Park, Kyue-nam
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.77-83
    • /
    • 2021
  • Background: Although symmetry of spatio-temporal parameter and center of pressure (COP) shift during walking is associated with knee adduction moment, research on clinical association with knee osteoarthritis (OA)-related knee pain and functional scores is lacking. Objects: The aims were 1) to compare symmetry of gait parameters and COP-shift in patients with unilateral knee OA and pain and matched controls, and 2) to investigate the relationship between symmetry of gait parameters and COP-shift, and clinical measures. Methods: Female subjects (n = 16) had with unilateral radiological knee OA and pain. Healthy controls (n = 15) were age-matched to OA group. Symmetry of foot rotation, step length, stance and swing phase, lateral symmetry of COP and anterior/posterior symmetry of COP during walking was assessed. To assess the clinical variables, pain intensity, pain duration and function using Knee Osteoarthritis Outcome Survey (KOOS) subscales were collected. We compared symmetry between groups using Mann-Whitney U-test or independent t-test. Relationships between clinical measures and symmetry index measured using Spearman's correlation test. Statistical significance was set at α = 0.05. Results: Knee OA group showed significantly greater values of only lateral symmetry of COP (p < 0.01) than healthy group. Values of lateral symmetry of COP had moderate or strong correlation significantly with the intensity of knee pain, pain duration, and scores of all KOOS subscales (p < 0.01). Conclusion: Patients with unilateral knee OA and pain showed more asymmetry of lateral COP-shift during walking compared with matched healthy controls. In addition, larger asymmetry of lateral COP-shift has the moderate or strong association with worse of knee pain, worse in KOOS scores and longer duration of knee pain. Asymmetry of lateral COP-shift during walking may be one of the characteristics of unilateral knee OA as the compensatory strategy response to unilateral OA of the knee.

The Geometrical Mode Analysis of an Elastically Suspended Rigid Body with Planes of Symmetry (대칭면을 갖는 강체 진동계의 진동모드에 대한 기하학적 해석)

  • Dan, Byeong-Ju;Choe, Yong-Je
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.110-117
    • /
    • 2000
  • Vibration modes obtained from a modal analysis can be better explained from a screw theoretical standpoint. A vibration mode can be geometrically interpreted as a pure rotation about the vibration center in a plane and as the twisting motion on a screw in a three dimensional space. This paper, presents the method to diagonalize a spatial stiffness matrix by use of a parallel axis congruence transformation. It also describes that the stiffness matrix diagonalized by a congruence transformation, can have the planes of symmetry depending on the location of the center of elasticity. For a plane of symmetry, any vibration mode can be expressed by the axis of vibration. Analytical solutions for the axis of vibration has been derived.

The Test-Retest Reliability and Criterion-Related Validity of a Trunk Stability Robot When Measuring Static Sitting and Standing Symmetry in Stroke Patients (뇌졸중 환자들을 위한 체간 안정화 로봇의 정적인 앉기와 서기 대칭성 평가의 검사-재검사간 신뢰도와 기준 관련 타당도)

  • An, Seung-Heon;Kim, Dong-Hoon;Jang, Young-Min
    • PNF and Movement
    • /
    • v.16 no.3
    • /
    • pp.405-414
    • /
    • 2018
  • Purpose: The purpose of this study was to examine test-retest reliability and criterion-related validity of a trunk stability robot when measuring the weight-bearing symmetry static sitting and standing in stroke patients. Methods: For 27 stroke patients, weight-bearing symmetry was assessed twice, 7 days apart. The intraclass correlation coefficient (ICC2,1) and minimal detectable change (MDC) were used to examine the level of agreement between test and retest. The criterion-related validity of weight -bearing symmetry was demonstrated by Spearman correlation of modified Barthel index (MBI), the sit to stand test (STS), the timed up & go Test (TUG), and the function in sitting test (FIST). Results: the test-retest agreements were excellent for the weight-bearing symmetry of static sitting (ICC2,1: 0.90) and standing (ICC2,1: 0.89). It all showed that the acceptable MDC for the weight-bearing symmetry of static sitting and standing was 0.11 and 0.16, respectively (highest possible score<20 %), indicating that the measures had a small and acceptable degree of measurement error. The weight-bearing symmetry of static sitting was significantly correlated with the TUG(r=-0.45) and FIST(r=0.46)(p<0.05); the weight-bearing symmetry of static standing was also significantly correlated with MBI (r=0.65), TUG (r=-0.67), FIST (r=0.61)(p<0.01), and STS (r=-0.47)(p<0.05). Conclusion: The weight-bearing symmetry of static sitting and standing assessed by the trunk stability robot showed highly sufficient test-retest agreement and mild-to-moderate validity. It could also be useful for clinicians and researchers to evaluate balance performance and monitor functional change in stroke patients.

CENTER SYMMETRY OF INCIDENCE MATRICES

  • Lee, Woo
    • Communications of the Korean Mathematical Society
    • /
    • v.15 no.1
    • /
    • pp.29-36
    • /
    • 2000
  • The T-ideal of F(X) generated by $x^{n}$ for all x $\in$ X, is generated also by the symmetric polynomials. For each symmetric poly-nomial, there corresponds one row of the incidence matrix. Finding the nilpotency of nil-algebra of nil-index n is equivalent to determining the smallest integer N such that the (n, N)-incidence matrix has rank equal to N!. In this work, we show that the (n, (equation omitted)$^{(1,....,n)}$-incidence matrix is center-symmetric.

  • PDF

Analysis for Pure Translation and Couple Modes of an Elastically Suspended Rigid Body with Planes of Symmetry (대칭면을 갖는 단일 강체의 순수 병진 및 순 짝힘 모우드 해석)

  • 김동욱;최용제
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.260-267
    • /
    • 2002
  • For an elastically suspended rigid body with the planes of symmetry in a three dimensional space, a novel analysis fur the vibration modes is presented. From the decompositions of the stiffness and inertia matrices, the conditions for the existence of pure translation and pure couple modes are analyzed for an elastically suspended rigid body with the planes of symmetry. From this analysis, it can be showed that how the structure of stiffness and inertia must be related in order to produce the pure translation and pure couple modes when an elastically suspended rigid body has one, two, or three planes of symmetry.

  • PDF

Dynamic Responses in Orthotropic Media Due to Pulsating Line Source

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.1E
    • /
    • pp.70-75
    • /
    • 1998
  • The analysis of dynamic responses are carried out on several anisotropic systems due to buried pulsating line sources. These include infinite, semi-infinite spaces. The media possess orthotropic or higher symmetry. The load is in the from of a normal stress acting with parallel to symmetry axis on the plane of symmetry within the materials. The results are first derived for infinite media. Subsequently the results for semi-infinite are derived by using superposition of the solution in the infinite medium together with a scattered solution from the boundaries. The sum of both solutions has to satisfy stress free boundary conditions, thereby leading to the complete solutions. The solutions are simplified to the systems possessing of higher symmetry, such as orthotropic, transversely isotropic, cubic, and isotropic symmetry.

  • PDF

Comparative Analysis of Gait Parameters and Symmetry between Preferred Walking Speed and Walking Speed by using the Froude Number

  • Yoo, Si-Hyun;Kim, Jong-Bin;Ryu, Ji-Seon;Yoon, Suk-Hoon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.221-228
    • /
    • 2016
  • Objective: The purpose of this study was to investigate differences in gait parameters and symmetry between walking speed by using the Froude number and preferred walking speed. Method: Fifty adults (age: $21.0{\pm}1.7years$, body weight: $71.0{\pm}9.2kg$, height: $1.75{\pm}0.07m$, leg length: $0.89{\pm}0.05m$) participated in this study. Leg length-applied walking speed was calculated by using the Froude number, defined as Fr = ${\upsilon}^2$/gL, where v is the velocity, g is the gravitational acceleration, and L is the leg length. Video data were collected by using eight infrared cameras (Oqus 300, Qualysis, Sweden) and the Qualisys Track Manager software (Qualisys, Sweden), with a 200-Hz sampling frequency during two-speed walking (preferred walking speed [PS] and leg length-applied walking speed [LS]) on a treadmill (Instrumented Treadmill, Bertec, USA). The step length, stride length, support percentage, cadence, lower joint angle, range of motion (ROM), and symmetry index were then calculated by using the Matlab R2009a software. Results: Step and stride lengths were greater in LS than in PS (p < 0.05). The right single-support percentage was greater in LS than in PS (p < 0.05). The hip joint angle at heel contact and toe-off were greater in LS than in PS (p < 0.05). The hip and knee joint ROM were greater in LS than in PS (p < 0.05). Conclusion: Based on our findings, we suggest that increased walking speed had a significant effect on step length, stride length, support percentage, and lower joint ROM.

A CHARACTERIZATION OF THE HYPERBOLIC DISC AMONG CONSTANT WIDTH BODIES

  • Jeronimo-Castro, Jesus;Jimenez-Lopez, Francisco G.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.54 no.6
    • /
    • pp.2053-2063
    • /
    • 2017
  • In this paper we prove a condition under which a hyperbolic starshaped set has a center of hyperbolic symmetry. We also give the definition of isometric diameters for a hyperbolic convex set, which behave similar to affine diameters for Euclidean convex sets. Using this concept, we give a definition of constant hyperbolic width and we prove that the only hyperbolic sets with constant hyperbolic width and with a hyperbolic center of symmetry are hyperbolic discs.