• Title/Summary/Keyword: capacitance sensor

Search Result 304, Processing Time 0.029 seconds

The Design of Capacitance Variation Detector for the Obstacle Detection System (방해물 감지 장치용 캐패시턴스 변화 감지기의 설계)

  • Kim, Jae-Min;Song, Yun-Seob;Yi, Sang-Yeoul;Kim, Soo-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.133-138
    • /
    • 2004
  • Today, the obstacle detection system has massive size and restrictive detection range. To solve these problems, this paper proposes the capacitance variation detector using the variated capacitance value as a result of the obstacle approaching. If obstacle approaches, the capacitance value of capacitance sensor is increased and the operating frequency of oscillator is decreased. Then this changed frequency appears to the output of the mixer that operate down conversion. The capacitance variation detector is produced by Hynix$0.35{\mu}$ CMOS process. In experiment result, the frequency of final output is 6.81 MHz at no obstacle and 31.45 MHz at approaching obstacle. In conclusion, proposed capacitance variation detector has small size, low power consumption and easiness to set up anywhere. So it is expected to substitute the obstacle detector.

A Study on the Fabrication and Electrical Characteristics of Hydraulic Pressure Sensors by Using Ceramics Materials (세라믹소재를 이용한 해수압센서 제작 및 전기적 특성 연구)

  • Park, Sung-Hyun;Kim, Eun-Sup;Jung, Jung-Kyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.384-389
    • /
    • 2015
  • In this paper, we fabricated ceramic body and sapphire wafer in order to develop a hydraulic pressure sensor with high sensitivity and high temperature stability. The sapphire wafer was adopted with a membrane of capacitance ceramic pressure sensor. The capacitance value of the sensor for the finite element analysis(FEM) showed a linear pressure characteristics. Membrane was processed with a diameter of 32.4 mm and a thickness of 1 mm by using alumina powders. Ceramic body was processed with a diameter 32.4 mm and a thickness 5 mm. The capacitance pressure sensor was made with high heat treatment of the ceramic body and the sapphire wafer. Initially capacitance of the pressure sensor was 50 pF and a capacitance of 110 pF was measured from 5 bar pressure. Output voltage of 5 V was appeared at 5 bar pressure.

Analysis of Oil-Mist-Detector applied Capacitance Sensor (용량센서를 적용한 오일증기검출기 거동 해석)

  • Lee G.S.;Kim T.O.;Kim H.Y.;Ahn J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.279-280
    • /
    • 2006
  • This paper analysised Oil-Mist-Detector applied Capacitance Sensor which protects Diesel engine & human from explosion by detecting density of oil mist distribution. Assuming that distance between oil mists is same, Capacitance sensor plates & all oil mists could be analogized to capacitors. From equivalent circuit of Oil-Mist-Detector, variation of Capacitance which is related to Oil Mist's diameter & density of oil mist distribution is obtainable.

  • PDF

Design & implementation of differential sensor using electrostatic capacitance method for detecting Ringer's solution exhaustion (링거액 소진 감지를 위한 정전용량방식의 차동센서 설계 및 제작)

  • Sim, Yo-Sub;Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.391-397
    • /
    • 2010
  • This paper proposes a differential structure sensor for detecting Ringer's solution exhaustion, in which three C-type electrodes of 10 mm width are disposed on a ringer hose at a distance of 5 mm each other in the direction of Ringer's solution flow. In the center of middle electrode, two capacitances are formed at the proposed sensor. When ringer hose is filled with Ringer's solution, there is no difference between two capacitances. But capacitance difference exist under the Ringer's solution shortage, because the shortage causes the hose filled with air from the top position electrode. The capacitance difference got to maximum 1.81 pF, when air was filled between top and middle electrode and the last of hose was filled with 10 % dextrose injection Ringer's solution. The capacitance difference varied with hose-wraparound coverage of electrodes as well as the width of them. For hose-wraparound electrode coverage of 90 % and 70 %, the maximum capacitance difference was 1.81 pF and 1.56 pF, respectively. A differential charge amplifier converted the capacitance difference to electric signal, and minimized electrodes' adhering problem and external noise coupling problem.

A Study on the In-process measurement of Burrs (Burr의 In-process 계측에 관한 연구)

  • 박동삼
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.242-246
    • /
    • 1996
  • Accurate measurements of burr profile and burr size are very important for the automation of deburring. In this paper, a new burr measurement system using capacitance sensor is proposed. Ultra precision milling machine was used as a sensor positioning system. The possibility and limitation of employing a capacitance sensor to defect burrs are also investigated. The proposed system is proven to be relatively accurate, easy to setup and lower cost. This system will be applicable to a fully automated deburring system with minor modifications.

  • PDF

Improvement of Sensitivity in Porous Silicon Alcohol Gas Sensors by UV Light (자외선조사에 의한 다공질 실리콘 알코올 센서의 감도 개선)

  • Kim, Seong-Jin;Choe, Bok-Gil
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.676-680
    • /
    • 1999
  • To do breath alcohol measurement, a sensor is necessary that it can detect low alcohol gas concentration of 0.01% at least. In this work, a capacitance-type alcohol gas sensor using porous silicon layer is developed to measure low alcohol gas concentration. The sensor using porous silicon layer has some sensitivity at room temperature by very large effective surface area, but there is still much room for improvement. In this experiment, we measured the capacitance of the sensor under 254 nm UV light on the porous silicon layer, in which alcohol solution was kept in a flask at 25, 35, and $45^{\circ}C$ by a heater. As the result, the improvement of sensitivity by illuminating UV light was observed. The increasing rate of the capacitance was shown to be double more than those measured under UV-off state. It is supposed that UV light activates response of the oriental and interfacial polarizations which have slow relaxation time for AC field.

  • PDF

Monitoring of Eccentric Machining Error and Cutting Force Variation using Cylindrical Capacity Spindle Sensor on CNC Turning (CNC선삭시 주축변위센서를 이용한 편심 가공오차와 절삭력 변화특성의 검출)

  • Maeng Heeyoung;Kim Sungdong
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.300-306
    • /
    • 2005
  • This paper presents the methodology for measuring eccentricity of the machined cylindrical part using CCS(cylindrical capacitance spindle sensor) signal in the CNC turning process. We use capacitance type sensor to take full advantage of averaging effect by using large capacitance area to encompass the whole side of a sensor. The intentionally proposed initial eccentricity is applied to the experimental testpieces, and their resultant relationships between CCS orbits and eccentricities are investigated. As a result, the possibility as a automatic detection apparatus for the CNC lathe is considered based on the linearities of CCS signal and magnitude of eccentricity of machined cylindrical surfaces.

  • PDF

Development of Sensing System for an Engine Oil Deterioration Detection Sensor Integrated with an Oil Filter (오일필터 일체형 엔진오일 퇴화감지센서용 센싱시스템 개발)

  • Chun, Sang-Myung
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.243-248
    • /
    • 2011
  • The purpose of this study is to develop a sensing system to measure the capacitance of a pre-developed engine oil deterioration detection sensor integrated with an oil filter. To measure the capacitance of engine oil in the sensor, it is used the way measuring the electric charging time in a capacitor by impressing DC volt. This method has merits on cost and signal stability. The measured capacitance is compensated by comparison with the one measured by an impedance analyzer. Also, using the dielectric constant gained by an impedance analyzer, the calculating equation of the dielectric constant of engine oil related with the currently developed sensor is decided. Finally, the degradation degree of engine oil is estimated according to the change rate of dielectric constant between green oil and used oil. The newly developed personal controller is to control a series of the processes.

Collocated Capacitance Sensor Design for Magnetic Bearing Control (자기베어링 제어용 동위형 축전 센서의 설계)

  • Shin, Dongwon;Kim, Jongwon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.10
    • /
    • pp.146-153
    • /
    • 1996
  • This paper presents the development of a collocated capacitance sensor and its application to the controller design for magnetic bearing supported rotor systems. The main feature of the sensor is that it is made of a compact printed circuit board(PCB) so that it can be built into the actuator coil of the magnetic bearing unit. The singnal processing unit hax been also developed. The experi- mental results of the sensor performance evaluation on sensitivity, bandwidth and resolution are presented. Then, simulation study shows the advantages of the collocated sensor for magnetic bearings over the nonco- llocated sensor. Finally, the experimental result on the performance of the collocated sensor based contrl- ler for a magnetic bearing rotor system is presented.

  • PDF

MEMS based capacitive biosensor for real time detection of bacterial growth (실시간 박테리아 감지를 위한 정전용량방식의 MEMS 바이오센서)

  • Seo, Hye-Kyoung;Lim, Dae-Ho;Lim, Mi-Hwa;Kim, Jong-Baeg;Shin, Jeon-Soo;Kim, Yong-Jun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.195-202
    • /
    • 2008
  • A biosensor based on the measurement of capacitance changes has been designed and fabricated for simple and realtime detection of bacteria. Compared to an impedance measurement technique, the capacitance measurement can make additional measurement circuits simpler, which improves a compatability for integration between the sensor and circuit. The fabricated sensor was characterized by detecting Escherichia coli(E. coli). The capacitance changes measured by the sensor were proportional to E. coli cell density, and the proposed sensor could detect $1{\times}10^6$ cfu/ml E. coli at least. The real-time detection was verified by measuring the capacitance every 20 minutes. After 7 hours of E. coli growth experiment, the capacitance of the sensor in the micro volume well with $4.5{\times}10^5$ cfu/ml of initial E. coli density increased by 20 pF, and that in another wells with $1.5{\times}10^6$ cfu/ml and $8.5{\times}10^7$ cfu/ml initial E. coli density increased by 56 pF and 71 pF, respectively. The proposed sensor has a possibility of the real-time detection for bacterial growth, and can detect E. coli cells with $1.8{\times}10^5$ cfu in nutrient broth in 5 hours.