• 제목/요약/키워드: arc generation

검색결과 229건 처리시간 0.027초

전차선로 속도향상에 따른 오버랩 구간(Overlap section) 경간 구성 기법 (Research on Configuration Optimization of Overlap Section in Overhead Catenary System for High-speed Railway)

  • 최태수;최규형
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.975-980
    • /
    • 2017
  • Overhead catenary system of electric railway has overlap sections which devide and tighten trolley wire supplying electric power to train, where current collection performances may become worse according to railway speed-up. Current collection tests conducted at 400 km/h test-bed section of Honam high-speed railway show that balanced line arrangement at overlap section is needed to secure current collection without arc generation between trolley wire and train current collection device. This paper proposes a design procedure of the overlap section to allow for tension increase and uplift of the trolley wires according to railway speed-up. By applying the proposed procedure to the overhead catenary system of Honam high-speed railway, it is suggested that the minimum span length should be 33.2 m for railway speed-up to 350 km/h and 43.7 m for speed-up to 400 km/h.

전기기기용 비닐절연전선에서의 직렬 아크에 의한 열화 특성 분석 (Analysis of Deterioration Characteristics of Polyvinyl Chloride Insulation Wires for Electrical Apparatus by Series Arcing)

  • 김향곤;길형준;김동욱;김동우;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.234-235
    • /
    • 2006
  • In this study, we experimented deterioration characteristics of PVC insulation wires for electrical apparatus by series arcing and analyzed the heat generation at the contacts of wires, glowing/growing process of copper oxide, waveforms of contact voltage, current, power dissipation, and so on. We found out that how glowing contacts and surface arcing can decompose PVC insulation and that subsequent series arc can lead to ignition. We expect that these results are useful for improving fire protection technology by providing a better understanding of how electrical fires can initiate.

  • PDF

Anti-Corrosion Performance and Applications of PosMAC® Steel

  • Sohn, Il-Ryoung;Kim, Tae-Chul;Ju, Gwang-Il;Kim, Myung-Soo;Kim, Jong-Sang
    • Corrosion Science and Technology
    • /
    • 제20권1호
    • /
    • pp.7-14
    • /
    • 2021
  • PosMAC® is a brand of Zn-Mg-Al hot-dip coated steel sheet developed by POSCO. PosMAC® can form dense surface oxides in corrosive environments, providing advanced corrosion resistance compared to traditional Zn coatings such as GI and GA. PosMAC® 3.0 is available for construction and solar energy systems in severe outdoor environments. PosMAC®1.5 has better surface quality. It is suitable for automotive and home appliances. Compared to GI and GA, PosMAC® shows significantly less weight reduction due to corrosion, even with a lower coating thickness. Thin coating of PosMAC® provides advanced quality and productivity in arc welding applications due to its less generation of Zn fume and spatters. In repeated friction tests, PosMAC® showed lower surface friction coefficient than conventional coatings such as GA, GI, and lubricant film coated GA. Industrial demand for PosMAC® steel is expected to increase in the near future due to benefits of anti-corrosion and robust application performance of PosMAC® steel.

금속 생체재료를 위한 Sn 함량에 따른 Zr-7Cu 합금설계 (Zr-7Cu Alloy Design According to Sn Content for Bio-Metallic Materials)

  • 김민석;김정석
    • 한국재료학회지
    • /
    • 제31권12호
    • /
    • pp.690-696
    • /
    • 2021
  • The purpose of this study is to develop a zirconium-based alloy with low modulus and magnetic susceptibility to prevent the stress-shielding effect and the generation of artifacts. Zr-7Cu-xSn (x = 1, 5, 10, 15 mass%) alloys are prepared by an arc melting process. Microstructure characterization is performed by microscopy and X-ray diffraction. Mechanical properties are evaluated using micro Vickers hardness and compression test. The magnetic susceptibility is evaluated using a SQUID-VSM. The average magnetic susceptibility value of the Zr-7Cu-xSn alloy is 1.176 × 10-8 cm3g-1. Corrosion tests of zirconium-based alloys are conducted through polarization test. The average Icorr value of the Zr-7Cu-xSn alloy is 0.1912 ㎂/cm2. The elastic modulus value of 14 ~ 18 GPa of the zirconium-based alloy is very similar to the elastic modulus value of 15 ~ 30 GPa of the human bone. Consequently, the Sn added zirconium alloy, Zr-7Cu-xSn, is very interesting and attractive as a biomaterial that reduces the stress-shielding effect caused by differences of elastic modulus between human bone and metallic implants. In addition, this material has the potential to be used in metallic dental implants to effectively eliminate artifacts in MRI images due to low magnetic susceptibility.

생체의료용 임플란트 소재를 위한 Zr-7Si-xSn 합금설계 (Design of Zr-7Si-xSn Alloys for Biomedical Implant Materials)

  • 김민석;김정석
    • 열처리공학회지
    • /
    • 제35권1호
    • /
    • pp.8-19
    • /
    • 2022
  • The metallic implant materials are widely used in biomedical industries due to their specific mechanical strenth, corrosion registance, and superior biocompatability. These metallic materials, however, suffer from the stress-shielding effect and the generation of artifacts in the magnetic resonance imaging exam. In the present study, we develope a Zr-based alloys for the biomedical implant materials with low elastic modulus and low magnetic susceptibility. The Zr-7Si-xSn alloys were fabricated by an arc melting process. The elastic modulus was 24~31 GPa of the zirconium-based alloy. The average magnetic susceptibility value of the Zr-7Si-xSn alloy was 1.25 × 10-8cm3g-1. The average Icorr value of the Zr-7Si-xSn alloy was 0.2 ㎂/cm2. The Sn added zirconium alloy, Zr-7Si-xSn, is very interested and attractive as a biomaterial that reduces the stress-shielding effect caused by the difference of elastic modulus between human bone and metallic implant.

가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구 (A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis)

  • 김아름;곽병섭;전태현;박현주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

한국의 의료폐기물 발생 및 처리의 공간적 분포에 관한 연구 (A Study on the Spatial Distribution of Medical Waste Generation and Treatment in Korea)

  • 오세은;이진헌;안호기;김기연;박석환;하권철;지경희;황성호;윤오섭;홍영습;이은일;김판기;이경무
    • 한국환경보건학회지
    • /
    • 제41권6호
    • /
    • pp.449-457
    • /
    • 2015
  • Objectives: In Korea, the system of management of medical waste largely relies on the incineration method. Our study aimed to identify any regional imbalances between the generation and treatment of medical waste, and provide reference data for future policy in Korea. Methods: We analyzed data on the amount of medical waste from 2,000 hospitals in 2012, 2013, and 2014 obtained from the Korea Environment Corporation. In the Arc GIS program (version 10.2.3), the addresses of hospitals and incinerators were transformed into map coordinates. The amount of waste generated by each hospital and the amount incinerated were represented by density and size of a triangle symbol, respectively. Results: As of 2014, the total amount of medical waste from the top 2,000 hospitals was 136,073 tons, out of which about half (49%) was generated in the capital area. Eleven incineration companies (three in the capital area, two in the Chungcheong Provinces area, one in the Jeolla Provinces area, and five in the Gyeongsang Provinces area) treated this waste. For the years 2012, 2013, and 2014, about 60% of the medical waste generated from the hospitals in the capital area was treated within the capital area and about 40% was transported to other areas, especially the Gyeongsang Provinces area, for treatment. On the other hand, about 90% of the medical waste incinerated in the capital area originated from the capital area. Conclusion: Our results suggest a spatial imbalance between the generation and treatment of medical waste in Korea and warrants multilateral policies, including the expansion of on-site treatment, strengthening regulation of the containment of medical wastes, promoting reductions in medical waste and more.

자궁경부암 방사선치료 시 직장가스 용적 변화에 따른 선량 비교 평가 - Phantom Study (Comparative evaluation of dose according to changes in rectal gas volume during radiation therapy for cervical cancer : Phantom Study)

  • 최소영;김태원;김민수;송흥권;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.89-97
    • /
    • 2021
  • 목 적: 본 연구에서는 자궁경부암 방사선치료 시 전산화치료계획에 없던 직장 내 가스 용적 변화에 따른 선량변화를 비교 평가하고자 한다. 대상 및 방법: 인체모형 팬텀(Anderson Research Laboratories Inc, RANDOTM phantom, USA)의 전산화 단층촬영 영상에 전산화치료계획시스템(EclipseTM Treatment Planning System, Varian, Palo Alto, version 15.6, USA)으로 9개의 필드를 이용한 정적 세기조절방사선치료계획(Static Intensity Modulated Radiation Therapy, S-IMRT)과 Full arc로 두 방향의 체적변조회전방사선치료계획(Volumetric Modulated Arc Therapy, VMAT)을 수립하였다. 임의의 가스 변수는 0.5 cm 단위로 2.0 cm까지 변화를 주어 계획표적체적(Planning Target Volume, PTV)에 포함될 수 있도록 하였다. 표적에 대한 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity Index, HI), PTV Dmax를 구하였고, 손상위험장기(Organ At Risk, OAR)에 대한 최소선량(Minimum Dose, Dmin)과 평균선량((Mean Dose, Dmean), 최대선량(Maximum Dose, Dmax)을 계산하여 비교하였다. T-검정을 실시하여 p-value를 구했으며 유의수준은 0.05로 설정하였다. 결 과: S-IMRT와 VMAT의 HI 결정계수(R2)는 0.9423, 0.8223으로 상관관계가 비교적 명확하였고, PTV Dmax 결과 임의의 가스 용적이 커질수록 최대 2.8%까지 증가하는 것으로 나타났다. OAR의 경우 두 전산화치료계획 모두 방광에서 유의한 차이가 없었고, 직장의 경우 +1.0 cm 이상의 가스 용적에서 두 전산화치료계획 모두 Dmean 700 cGy 이상의 유의한 선량 차이가 나타났다. 방광의 Dmean을 제외한 모든 값에서 p-value 0.05 이하로 통계적인 유의한 차이를 확인하였다. 결 론: 기준 전산화치료계획에 없던 가스 발생 시 가스 용적 크기가 커질수록 PTV의 선량 변화와 직장에 전달되는 선량이 증가하였다. 방사선치료 진행 시 직장 가스의 용적이 클 경우 발생 할 수 있는 선량 전달 오류를 최소화하기 위한 노력이 반드시 필요한 것으로 판단되었다. 향후 가스 용적의 다양한 크기와 위치를 변수로 설정하여 추가적인 연구가 진행되어진다면 유익한 평가가 이루어 질 수 있을 것으로 사료된다.

표면처리된 Ni-Cr계 합금의 FLiNaK 용융염 하에서의 고온 안정성 (Thermal stability of surface modified Ni-Cr-alloys in molten FLiNaK salt)

  • 조현;방광현;이태석;이병우
    • 한국결정성장학회지
    • /
    • 제22권5호
    • /
    • pp.227-232
    • /
    • 2012
  • 차세대 원자력발전용 고온 열교환기 소재로 이용될 가능성이 높은 Ni-Cr계 고온합금인 Inconel 617과 Hastelloy X의 표면처리에 따른 FLiNaK(LiF-NaF-KF) 용융염 하에서의 고온물성에 대한 연구를 수행하였다. Inconel 617과 Hastelloy X기판 상에 각각 PVD인 arc discharge 및 sputtering법에 의해 TiAlN 및 $Al_2O_3$ 박막을 코팅 하였다. 이러한 표면처리가 이들 합금의 FLiNaK 용융염 하 고온 안정성에 미치는 영향에 대해 연구하였다. 용융염 하 Ni-Cr계 고온합금의 부식 원리를 이해하기 위해, 용융염 수송 loop에 사용 중 파단된 Inconel 파이프에 대한 미세구조 분석을 수행하였다. 표면처리 된 합금들을 $600^{\circ}C$ 용융염 내에서 열처리 하였으며, 열처리 전후 시편들에 대해 상형성, 미세구조 등 고온 물성 변화를 측정하였다. 연구결과 코팅되지 않은 경우 보다 TiAlN 및 $Al_2O_3$ 박막이 코팅된 소재에서 보다 우수한 고온 안정성을 보여주었다.

댐군의 연계운영을 위한 수학적 모형 (A Mathematical Model for Coordinated Multiple Reservoir Operation)

  • 김승권
    • 한국수자원학회논문집
    • /
    • 제31권6호
    • /
    • pp.779-793
    • /
    • 1998
  • 본 연구에서는 용수공급을 위한 이수관점에서 수력발전의 경제적 운영과 더불어 용수수요에 효과적으로 대처할 수 있는 댐군의 경제적 연계운영 최적화 모형을 제안한다. 제안된 모형은 댐군의 연계운영을 통한 발전방류의 최대화, 용수 수요량에 대한 물부족량(shortfall)의 최소화, 불필요한 여수로 방류량의 최소화, 홍수기를 대비한 저수지의 여유공간 확보, 그리고 발전효율을 높일 수 있는 저수위의 확보 등을 고려하였다. 제안된 최적화 모형은 구조적으로는 최적화 모형이지만, 실질적으로는 댐군의 연계운영의 행태를 표현한 시뮬레이션 모형이라 할 수 있으며, 용수공급계획 수립시 최대 용수공급 가용량 산정에 활용하기 위해서 개발된 모형이다. 최적화모형은 약 3,920개의 혼합정수변수와 약 7만$\times$13만 Node-Arc Incidence Matrix로 표현되는 네트워크 모형을 포함하는 여러 기간에 걸친 혼합정수계획 문제 (multi-period mixed integer programming)로 설계되었으며, 대형문제로부터 야기되는 수많은 자료를 효과적으로 처리하기 위하여 DBMS를 활용하였다. 본 모형의 효과를 검토하기 위하여 한강수계에 위치한 댐들 중에서 2개의 다목적 댐과 3개의 발전용 댐들의 연계운영에 실험하여 보았다. 실험결과, 본 연구에서 수립된 모형의 현실적인 이용을 위한 수정 보완과, 효과적인 댐 유역별 중장기 유입량 예측시스템이 개발되어 실시간으로 운영될 수 있도록 수정, 보완된다면 현재의 운영방법보다 더 좋은 운영방안을 제시하므로써, 환경보존에 따른 이득은 물론 용수공급 능력을 증대시킬 수 있는 대안이 될 수 있다.

  • PDF