• 제목/요약/키워드: adhesive pattern

검색결과 131건 처리시간 0.028초

레이저 스페클 간섭법을 이용한 반도체 패키지의 비파괴검사 (Non-destructive Inspection of Semiconductor Package by Laser Speckle Interferometry)

  • 김경석;양광영;강기수;최정구;이항서
    • 비파괴검사학회지
    • /
    • 제25권2호
    • /
    • pp.81-86
    • /
    • 2005
  • 본 논문에서는 반도체 패키지 내부결함의 비파괴 정량평가를 위한 ESPI 기법을 이용한 시스템 및 검사기 법을 제안하고 있으며, 검사시스템은 ESPI 검사장치, 열변형유도장치, 단열챔버로 구성되어있다. 기존 초음파, X-ray 기반의 검사기법에 비하여 측정시간 및 검사방법이 용이하며, 결함의 정량검출이 가능하다는 장점이 있다. 검사결과에서 대부분의 결함이 열 방출이 많은 칩 주위에서 박리결함으로 나타났으며, 원인은 층간 접착강도의 약화와 열분배 설계에서 문제점인 것으로 사료된다.

상아질 표면 처리 방법에 따른 Compomer의 전단 결합 강도 (SHEAR BOND STRENGTH OF COMPOMER ACCORDING TO DENTIN SURFACE TREATMENT)

  • 오영학;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.171-179
    • /
    • 2001
  • The purpose of this study was to evaluate the shear bond strength of compomers according to dentin surface treatment. Two materials of compomer were devided into six groups. The compomer used in this study were Dyract AP(D) and F2000(F), Group 1 (DN) and 4(FN) were treated according to manufacturers instructions as control groups. Group 2(DE) and 5(FE) were treated with 37% phosphoric acid and group 3(DA) and 6(FA) were treated with air abrasion unit (80 psi, 50 m aluminum oxide particles) respectively as experimental groups. After dentin surface treatment, compomers were bonded. Completed samples were stored in 100% humidity. 37C during 7 days, and then, the shear bond strength of specimens were evaluated. The results were as follows: 1. In the case of Dyract AP, the shear bond strength was showed the highest value of 9.10 MPa in dentin surface treatment with air abrasion unit. but there were no significant differences to the other groups. 2. In the case of F2000. the shear bond strength was showed the highest value of 13.51MPa and there were significant differences to the other groups(p<0.05). 3. The shear bond strength of F2000 was higher than Dyract AP in each dentin surface treatment. and in the case of etching and air abrasion. there were significant differences(p<0.05). 4. As a result of observation of SEM. the most of fracture pattern was adhesive failure in group 1(DN), 2(DE) and 4(FN), and cohesive failure in group 3(DA), S(FE) and 6(FA).

  • PDF

플라즈마 용사층의 피로거동 및 강의 피로수명 변화에 관한 연구 (A Study on the Fatigue behavior of Plasma Sprayed Coating Layer and Fatigue Life Variation of Steel)

  • 박만호;한주철;정철;송요승;노병호;이구현
    • 한국표면공학회지
    • /
    • 제31권2호
    • /
    • pp.81-90
    • /
    • 1998
  • NiCrAly/YSZ(8wt% Y2O3-Zro2) functionally fraded thermal barrier coating (FGC) layers on a Co-base sureralloy (HAYNESS 188) substrate were fabricated using Ar shielded single torch air plasma spraying method. Functional grading were produced with the stepwise compositional change throughout layer thinkness. Microstructural observation revealed a sucessful fabrication of NiCrAly/YSZ FGC. From the results of the curvature measurement, adhesive stength measurement and thermal shock test for the FGC, it was concluded that the optimum enhance of functionally graded coating layer thinkcess and compositional pattern exit to enhance the properties of FGC, which is closely reated to the internal residual distribution with it.

  • PDF

O2 플라즈마 표면 처리 공정 후 라미네이션 공정으로 제작된 흑연 페이스트 기반의 저비용 및 고감도 유연 압력 센서 (Low Cost and High Sensitivity Flexible Pressure Sensor Based on Graphite Paste through Lamination after O2 Plasma Surface Treatment Process)

  • 남현진;강철;이승우;김선우;박세훈
    • 마이크로전자및패키징학회지
    • /
    • 제29권4호
    • /
    • pp.21-27
    • /
    • 2022
  • 저렴한 전도성 흑연을 인쇄전자 공법으로 유연 압력 센서를 개발하였다. 유연 압력 센서는 의료, 게임, AI 등 미래 산업에 활용될 소재로 각광받고 있다. 유연 압력 센서용 인쇄전극을 다양한 전기-기계적 특성을 평가한 결과 최대인장률 20%, 30°의 인장/굽힘, 간이 맥박 시험에서 일정한 저항 변화율을 보였다. 이렇게 검증이 완료된 전극을 시뮬레이션하여 더 적합한 matrix 패턴을 설계하였다. Serpentine 패턴을 활용하여 matrix 패턴 제작과 인캡슐레이션을 동시에 진행할 수 있는 공정을 활용하였다. 인쇄된 흑연 전극의 한쪽 면에 접착력 증가를 위한 O2 플라즈마 표면처리하고, 90°회전시켜, 라미네이션 공정을 통해 2개의 전극을 하나로 제작하였다. 이렇게 제작된 matrix 패턴을 인체의 손목 맥박 위치에 부착하여 실측을 진행한 결과 남녀 상관없이 일정한 저항 변화율을 보였다.

치과용 니켈-크롬합금에 대한 표면 처리가 인장접착강도에 미치는 영향 (THE EFFECTS OF SURFACE TREATMENT OF DENIAL NICKEL-CHROMIUM ALLOY ON TENSILE BOND STRENGTH)

  • 이은숙;권오원
    • 대한치과교정학회지
    • /
    • 제27권3호
    • /
    • pp.493-502
    • /
    • 1997
  • 본 연구에서는 치과용 니켈-크롬합금의 표면에 전처리없이 치과용 브라켓을 Super-bond로 접착한 대조군과 샌드블라스팅 및 tin-plating을 각각 혹은 병용으로 표면처리후 Super-bond로 접착한 실험각군의 인장접착강도, 브라켓 탈락양상 및 주사전자현미경 소견을 비교하여 임상적용 가능성을 알아보고자 하였으며 다음과 같은 결과를 얻었다. 1. 인장장접착강도는 니켈-크롬합금의 표면에 샌드블라스팅 처리후 Super-bond로 브라켓을 접착한 실험 I군이 $14.41{\pm}2.24MPa$로 가장 높았고, tin-plating처리후 Super-bond로 접착한 실험 III군이 $13.59{\pm}1.51MPa$, 샌드블라스팅후 tin-lating처리를 하고 Super-bond로 접착한 실험 II군이 $12.27{\pm}1.45MPa$, 특정한 표면처리 없이 Super-bond로 접착한 대조군이 $10.50{\pm}1.57MPa$로 가장 낮게 나타났으나 실험 I군과 실험 III군간, 실험 III군과 실험 II군간, 실험 II군과 대조군간에는 유의한 차이가 없었다(p>0.05). 2. 브라켓의 주된 탈락양상은 대조군의 경우 $70\%$가 브라켓과 접착제 계면에서 adhesive failure를, $30\%$가 니켈-크롬합금과 접착제 계면에서 adhesive failure를 나타내었고, 실험 각군은 모두 브라켓과 접착제 계면에서 adhesivefailure 를 나타내었다. 3. 주사전자현미경 소견에서 대조군의 경우 일부 레진이 브라켓 기저면에 부착되어 나타났으나 실험 각군에서는 거의 대부분의 레진이 니켈-크롬합금면에 부착되어 관찰되었고, 샌드블라스팅만 시행한 시편면이 가장 균일하고 조밀한 표면 요철상을 나타내었다.

  • PDF

타이타늄 표면 코팅 처리에 따른 타이타늄도재관의 파절강도 비교 (A COMPARISON OF FRACTURE STRENGTHS OF PORCELAIN-FUSED-TO-TITANIUM CROWN AMONG TITANIUM SURFACE COATING TREATMENTS)

  • 김지혜;박상원;방몽숙;양홍서;박하옥;임현필;오계정;김현승;이광민;이경구
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.203-215
    • /
    • 2007
  • Statement of problem: Titanium and its alloy, with their excellent bio-compatibility and above average resistance to corrosion, have been widely used in the field of dentistry. However, the excessive oxidization of titanium which occurs during the process of firing on porcelain makes the bonding of titanium and porcelain more difficult than that of the conventional metal-porcelain bonding. To solve this problem related to titanium-porcelain bonding, several methods which modify the surfaces, coat the surfaces of titanium with various pure metals and ceramics, to enable the porcelain adhesive by limiting the diffusion of oxygen and forming the adhesive oxides surfaces, have been investigated. Purpose: The purpose of this study was to know whether the titanium-porcelain bonding strength could be enhanced by treating the titanium surface with gold and TiN followed by fabrication of clinically applicable porcelain-fused-to-titanium crown Material and method: The porcelain-fused-to-titanium crown was fabricated after sandblasting the surface of the casting titanium coping with $Al_2O_3$ and treating the surface with gold and TiN coating followed by condensation and firing of ultra-low fusing porcelain. To compare with porcelain-fused-to-titanium crowns, porcelain-fused-to-gold crowns were fabricated and used as control groups. The bonding strengths of porcelain-fused-to-gold crowns and porcelain-fused-totitanium crowns were set for comparison when the porcelain was fractured on purpose to get the experimental value of fracture strength. Then, the surface were examined by SEM and each fracturing pattern were compared with each other Result:Those results are as follows. 1. The highest value of fracture strength of porcelain-fused-to-titanium crowns was in the order of group with gold coating, group with TiN coating, group with $Al_2O_3$ sandblasting. No statistically significant difference was found among the three (P>.05). 2. The porcelain-fused-to-gold crowns showed the highest value in bonding strength. The bonding strength of crowns porcelain-fused-to-titanium crowns of rest groups showed bonding strength reaching only 85%-94% of that of PFG, though simple comparision seemed unacceptable due to the difference in materials used. 3. The fracturing patterns between metal and porcelain showed mixed type of failure behavior including cohesive failure and adhesive failure as a similar patterns by examination with the naked eye and SEM. But porcelain-fused-to-gold crowns showed high incidence of adhesive failure and porcelain-fused-to-titanium crowns showed high incidence of cohesive failure. Conclusion: Above results proved that when fabricating porcelain-fused-to-titanium crowns, treating casting titanium surface with gold or TiN was able to enhance the bonding strength between titanium and porcelain. Mean value of masticatory force was found to showed clinically acceptable values in porcelain bonding strength in all three groups. However, more experimental studies and evaluations should be done in order to get better porcelain bonding strength and various surface coating methods that can be applied on titanium surface with ease.

Ceromer crown의 교합면 두께에 따른 압축 파절 강도의 비교 (The compressive fracture strength of ceromer crown by the difference of occlusal thickness)

  • 김지연;박하옥;양홍서
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.205-215
    • /
    • 2002
  • This study investigated the compressive fracture strength of Targis ceromer crown by the difference of occlusal thickness on a maxillary first premolar. Control group was a castable IPS-Empress all-ceramic crown with occlusal thickness of 1.5 mm constructed by layered technique. Experimental groups were Targis crowns having different occlusal thicknesses of 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, respectively. The classification of Targis group is T10, T15, T20, T25 and T15N (for no-thermocycling and occlusal thickness of 1.5mm). Ten samples were tested per each group. Except occlusal thickness, all dimension of metal die is same with axial inclination of $10^{\circ}$and marginal width 0.8mm chamfer. All crowns were cemented with Panavia F and thermocycled 1,000 times between $5^{\circ}$ and $55^{\circ}$ water bath with 10 sec dwelling time and 10 sec resting time. The compressive fracture strength was measured by universal testing machine. The results were as follows : 1. Fracture strength was increased as the occlusal thickness increased : compressive fracture strength of Group T10, T15, T20, T25 was $66.65{\pm}4.88kgf$, $75.04{\pm}3.01kgf$, $87.07{\pm}7.06kgf$ and $105.03{\pm}10.56kgf$, respectively. 2. When comparing material, Targis crown had higher fracture strength than IPS-Empress crown : the mean compressive strength of group T15 was $75.04{\pm}3.01kgf$ and the value of group Control was $37.66{\pm}4.28kgf$. 3. Fracture strength was decreased by thermocycling : the compressive fracture strength of T15 was $75.04{\pm}3.01kgf$, which is lower than $90.69{\pm}6.88kgf$ of group T15N. 4. The fracture line of crowns began at the loading point and extended along long axis of tooth. IPS-Empress showed adhesive failure pattern whereas Targis had adhesive and cohesive failure. In the SEM view, stress was distributed radially from loading point and the crack line was more prominent on Targis crown.

폴리카보네이트 브라켓 부착 시 결합강도 증진을 위한 표면처리 효과 (The Effect of Surface Treat`ment on Bond Strength of Polycarbonate Bracket)

  • 김석필;김년경;이현정;황현식
    • 대한치과교정학회지
    • /
    • 제36권5호
    • /
    • pp.331-338
    • /
    • 2006
  • 본 연구는 폴리카보네이트 브라켓 부착 시 표면처리가 결합강도를 증진시키는지 알아보고자 시행되었다. 소의 하악 중절치를 포매하여 만든 100개의 시편에 광중합형 레진 접착제를 이용하여 폴리카보네이트 브라켓(Alice, 광명 데이콤, 대한민국)을 부착하였다. 대조군의 경우, 표면처리 없이 부착한 반면, 실험군의 경우 샌드블라스팅 처리한 경우, plastic conditioner 처리하여 부착한 경우, 그리고 샌드블라스팅과 함께 plastic conditioner 처리한 경우로 구분하여 접착하였다. 만능시험기를 이용하여 전단결합강도를 측정하고 파절양상을 비교 분석한 결과, plastic conditioner나 샌드블라스팅으로 표면처리를 시행한 경우 표면처리를 시행하지 않은 경우에 비해 높은 결합강도를 보였다 (p < 0.001). 샌드블라스팅과 plastic conditioner를 모두 처리한 경우는 샌드블라스팅만이나 Plastic conditioner만 처리한 경우보다 높은 결합강도를 보였으며, 특히 샌드블라스팅만 처리한 경우에 비해서는 통계적 유의차를 보였다 (p < 0.05). 이상의 연구결과는 폴리카보네이트 브라켓 부착 시 결합강도 증진을 위해서 베이스의 표면처리가 필요하며 샌드블라스팅 후 plastic conditioner 도포가 가장 효과적임을 보여주었다.

열가압 리튬 디실리케이트 전장도재와 지르코니아 하부구조의 전단결합강도 평가 (Adhesion between heat-pressed lithium disilicate veneer and zirconia framework: Shear bond strength evaluation)

  • 김재홍
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.335-341
    • /
    • 2020
  • 본 연구의 목적은 shear bond strength을 이용하여 pressed lithium disilicate 전장도재와 zirconia core의 접착을 비교 분석하는 것이다. Zirconia blank(Zirtooth, HASS, Gangneung, Korea)에 각 pressed ceramic(IPS e.max Zirpress, Vita PM9, GC Initial IQ, HASS Rosetta UP)이 적용된 시편을 제작하였다(N=40). 전단결합강도를 비교 평가하기 위해 The Schmitz-Schulmeyer test method을 이용하였고 산출된 파괴하중의 값을 분석했다. 산출된 네 가지 전단결합강도 값들 간의 평균 비교는 일원분산분석(one-way ANOVA)을 통해 이루어졌고, Tukey의 사후검정을 실시하여 서로 간의 평균 차이가 통계적으로 유의함을 검증하였다. 또 파절면의 3D 분석을 통하여 파괴 표면을 관찰하여, 그 파괴 양상도 분류하였다. 실험군별 전단결합강도는 IPS e.max Zirpress 16.69±3.11MPa, VITA PM9 14.21±3.63MPa, GC Initial IQ 11.17±2.92MPa, HASS Rosetta SM 27.90±5.71MPa이었으며, Lithium disilicate ceramic veneer(HASS Rosetta SM)의 결합 강도는 다른 제품들보다 통계적으로 유의하게 높았다(p<0.05). 또, 파괴면의 유형 분류 결과, 모든 시편에서 cohesive 파괴는 관찰되지 않았고 주로 adhesive와 cohesive가 같이 조합된 파괴 유형이 관찰되었다. 본 연구 결과에 의해서 pressed lithium disilicate 전장도재가 기존의 pressed to zirconia system보다 나은 접착력을 보여주었다.

해수전착 코팅을 이용한 내부식성 철근의 개발 및 적용성에 대한 연구 (2) -해수전착된 구조용 철근의 적용성 평가 (Development and Application of Anti-Corrosive Steel Using Electro-Deposition of Sea Water (2)- Evaluation of Application Rebar with Electro-Deposition Using Sea Water)

  • 권성준;이상민;박상순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권6호
    • /
    • pp.155-162
    • /
    • 2012
  • 해수에 노출된 콘크리트 구조물은 시간의 경과에 따라 철근부식이 야기될 수 있으며, 이는 구조적인 성능저하로 진전된다. 1단계 연구에서 도출된 해수전착시스템의 개발을 통하여 2단계 연구에서는 해수전착 코팅된 철근 및 코팅철근을 사용한 RC 콘크리트 부재의 구조적, 내구적 성능이 평가되었다. 내구적 성능평가에서는 반전위 측정이 수행되었는데, 코팅된 철근은 일반철근의 35%수준의 부식속도를 가지고 있었으므로 높은 내부식성을 확보하고 있었다. 구조실험에서는 직접인장시험, 부착력시험, RC 부재를 이용한 휨 및 전단시험이 수행되었다. 인장강도 시험에서는 3.2%, 부착성능에서는 8.8%의 강도 증가가 코팅된 철근에서 평가되었다. RC보에 대한 실험에서는 최대하중 및 파괴형태는 두가지 경우에서 거의 동일하게 평가되었다. 해수전착된 시편은 철근주위에 콘크리트와 비슷한 화합물(수산화마그네슘, 탄산칼슘)이 형성되므로 부착력 및 강도를 일부 증가시키는 것으로 평가되었다. 해수전착철근은 피로, 내충격성, 장기침지실험 등을 통하여 성능이 입증되면 더욱 활발하게 사용될 것으로 사료된다.