References
- H. De Backer, G. Van Maele, N. De Moor, L. Van Den Berghe, "Long-term results of short-span versus long-span fixed dental prostheses: An up to 20-year retrospective study", International Journal of Prosthodontics, Vol.21, No.1, pp.75-85, 2008. DOI: https://doi.org/10.1016/S0022-3913(08)60157-2
- T.R. Walton, "An up to 15-Year Longitudinal Study of 515 Metal-Ceramic FPDs: Part 1. Outcome" International Journal of Prosthodontics, Vol.15, No.5, pp.439-445, 2002.
- K. Tan, B. E. Pjetursson, N. P. Lang, E. S. Y. Chan, "A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years - III. Conventional FPDs", Clinical Oral Implants Research, Vol.15, No. 6, pp.654-666, 2004. DOI: https://doi.org/10.1111/j.1600-0501.2004.01119.x
- A. J. Raigrodski, "Contemporary materials and technologies for all-ceramic fixed partial dentures: A review of the literature", Journal of Prosthetic Dentistry, Vol.92, No.6, pp.557-562, 2004. DOI: https://doi.org/10.1016/j.prosdent.2004.09.015
- P. Baldissara, A. Llukacej, L. Ciocca, F. L. Valandro, R. Scotti, "Translucency of zirconia copings made with different CAD/CAM systems", Journal of Prosthetic Dentistry, Vol.104, No.1, pp.6-12, 2010. DOI: https://doi.org/10.1016/S0022-3913(10)60086-8
- C. H. Lim, Y. S. Jang, M. H. Lee, T. S. Bae, "Evaluation of fracture strength for single crowns made of the different types of lithium disilicate glass-ceramics", Odontology, 2019 Sep 28. DOI: https://doi.org/10.1007/s10266-019-00460-4 [Epub ahead of print] DOI: https://doi.org/10.1007/s10266-019-00460-4
- E. Tsalouchou, M. J. Cattell, J. C. Knowles, P. Pittayachawan, A. McDonald, "Fatigue and fracture properties of yttria partially stabilized zirconia crown systems", Dental Materials, Vol.24, No.3, pp.308-318, 2008. DOI: https://doi.org/10.1016/j.dental.2007.05.011
- E. B. Goldin, N. W. Boyd, G. R. Goldstein, E. L. Hittelman, V. P. Thompson, "Marginal fit of leucite-glass pressable ceramic restorations and ceramicpressed-to-metal restorations", Journal of Prosthetic Dentistry, Vol.93, No.2, pp.143-147, 2005. DOI: https://doi.org/10.1016/j.prosdent.2004.10.023
- J. E. Holden, G. R. Goldstein, E. L Hittelman, E. A. Clark, "Comparison of the Marginal Fit of Pressable Ceramic to Metal Ceramic Restorations", Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry, Vol.18, No.8, pp.645-645, 2009. DOI: https://doi.org/10.1111/j.1532-849X.2009.00497
- H. Luthy, J. K. Dong, A. Wohlwend, P. E. Scharer, "Effects of veneering and glazing on the strength of heat-pressed ceramics", SSO, Vol.103, No.10, pp.1257-1260, 1993.
- G. Christensen, "PFM vs. Zirconia Restorations - How Are They Comparing Clinically?", Clinician's Report CR Foundation, Vol.1, No.11, 2008.
- B. Stawarczyk, M. Ozcan, M. Roos, A. Trottmann , I. Sailer, C. H. F. Hammerle, "Load-bearing capacity and failure types of anterior zirconia crowns veneered with overpressing and layering techniques", Dental Materials, Vol.27, No.10, pp.1045-1053, 2011. DOI: https://doi.org/10.1016/j.dental.2011.07.006
- J. E. Choi, J. N. Waddell, B. Torr, M. V. Swain, "Pressed ceramics onto zirconia. Part 1: Comparison of crystalline phases present, adhesion to a zirconia system and flexural strength", Dental Materials, Vol.27, No.12, pp.1204-1212, 2011. DOI: https://doi.org/10.1016/j.dental.2011.08.006
- J. Fischer, B. Stawarzcyk, A. Trottmann, C. H. F. Hammerle, "Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites", Dental Materials, Vol.25, No.4, pp.419-423. 2009. DOI: https://doi.org/10.1016/j.dental.2008.09.003
- B. Ohlmann, P. Rammelsberg, M. Schmitter, S. Schwarz, O. Gabbert, "All-ceramic inlay-retained fixed partial dentures: Preliminary results from a clinical study", Journal of Dentistry, Vol.36, No.9, pp.692-696, 2008. DOI: https://doi.org/10.1016/j.jdent.2008.04.017
- E. A. Bonfante, B. Rafferty, R. A. Zavanelli, N. Silva, E. D. Rekow, V. P. Thompson, "Thermal/mechanical simulation and laboratory fatigue testing of an alternative yttria tetragonal zirconia polycrystal core-veneer all-ceramic layered crown design", European Journal of Oral Sciences, Vol.118, No.2, pp.202-209, 2010. DOI: https://doi.org/10.1111/j.1600-0722.2010.00724.x
- B. W. Marchack, Y. Futatsuki, C. B. Marchack, S. N. White, "Customization of milled zirconia copings for all-ceramic crowns: A clinical report", Journal of Prosthetic Dentistry, Vol.99, No.3, pp.169-173, 2008. DOI: https://doi.org/10.1016/S0022-3913(08)00028-0
- P. G. Coelho, N. R. Silva, E. A. Bonfante, P. C. Guess, E. D. Rekow, V. P. Thompson, "Fatigue testing of two porcelain-zirconia all-ceramic crown systems", Dental Materials, Vol.25, No.9, pp.1122-1127, 2009. DOI: https://doi.org/10.1016/j.dental.2009.03.009
- M. V. Swain, "Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures", Acta Biomaterialia, Vol.5, No.5, pp.1668-1677, 2009. DOI: https://doi.org/10.1016/j.actbio.2008.12.016
- F. Beuer, J. Schweiger, M. Eichberger, H. F. Kappert, W. Gernet, D. Edelhoff, "High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - A new fabrication mode for all-ceramic restorations", Dental Materials, Vol.25, No.1, pp.121-128, 2009. DOI: https://doi.org/10.1016/j.dental.2008.04.019
- M. Schmitter, M. Schweiger, D. Mueller, S. Rues S, "Effect on in vitro fracture resistance of the technique used to attach lithium disilicate ceramic veneer to zirconia frameworks", Dental Materials, Vol.30, No.2, pp.122-130, 2014. DOI: https://doi.org/10.1016/j.dental.2013.10.008
- A. Baltzer, "All-ceramic single-tooth restorations: Choosing the material to match the preparation - Preparing the tooth to match the material", Materialgerechte Praparation, Vol.11, No.3, pp.241-256, 2008.
- I. Denry, J. A. Holloway, "Ceramics for dental applications: A review", Materials, Vol.3, No.1, pp.351-368, 2010. DOI: https://doi.org/10.3390/ma3010351
- E. P. Rocha, R. B. Anchieta, A. C. Freitas-Junior, E. O. de Almeida, P. M. Cattaneo, C. C. Ko, "Mechanical behavior of ceramic veneer in zirconia-based restorations: A 3- dimensional finite element analysis using microcomputed tomography data", The Journal of Prosthetic Dentistry, Vol.105, No.1, pp.14-20, 2011. DOI: https://doi.org/10.1016/S0022-3913(10)60184-9
- M. N. Aboushelib, N. de Jager, C. J. Kleverlaan, A. J. Feilzer, "Microtensile bond strength of different components of core veneered all-ceramic restorations", Dental Materials, Vol.21, No.10, pp.984-991, 2005. DOI: https://doi.org/10.1016/j.dental.2005.03.013
- M. Ishibe, A. J. Raigrodski, B. D. Flinn, K. H. Chung, C. Spiekerman, R. R. Winter, "Shear bond strengths of pressed and layered veneering ceramics to high-noble alloy and zirconia cores", The Journal of Prosthetic Dentistry, Vol.106, No.1, pp.29-37, 2011. DOI: https://doi.org/10.1016/S0022-3913(11)60090-5
- M. N. Aboushelib, C. J. Kleverlaan, A. J. Feilzer, "Microtensile bond strength of different components of core veneered all-ceramic restorations: Part II: Zirconia veneering ceramics", Dental Materials, Vol.22, No.9, pp.857-863, 2006. DOI: https://doi.org/10.1016/j.dental.2005.11.014
- I. Sailer, A. Feher, F. Filser, L. J. Gauckler, H. Luthy, C. H. F. Hammerle, "Five-year clinical results of zirconia frameworks for posterior fixed partial dentures", International Journal of Prosthodontics, Vol.20, No.4, pp.383-388, 2007.
- J. Teng, H. Wang, Y. Liao, X. Liang, "Evaluation of a conditioning method to improve core-veneer bond strength of zirconia restorations", The Journal of Prosthetic Dentistry, Vol.107, No.6, pp.380-387, 2012. DOI: https://doi.org/10.1016/S0022-3913(12)60095-X
- P. C. Guess, A. Kulis, S. Witkowski, M. Wolkewitz, Y. Zhang, J. R. Strub, "Shear bond strengths between different zirconia cores and veneering ceramics and their susceptibility to thermocycling", Dental Materials, Vol.24, No.11, pp.1556-1567, 2008. DOI: https://doi.org/10.1016/j.dental.2008.03.028
- M. Dundar, M. Ozcan, B. Gokce, E. Comlekoglu , F. Leite, L. F. Valandro, "Comparison of two bond strength testing methodologies for bilayered all-ceramics", Dental Materials, Vol.23, No.5, pp.630-636, 2007. DOI: https://doi.org/10.1016/j.dental.2006.05.004
- R. G. Luthardt, O. Sandkuhl, B. Reitz, "Zirconia-TZP and alumina-advanced technologies for the manufacturing of single crowns", The European journal of prosthodontics and restorative dentistry, Vol.7, No.4, pp.113-119, 1999.
- I. A. Hammad, Y. F. Talic, "Designs of bond strength tests for metal-ceramic complexes: Review of the literature", Journal of Prosthetic Dentistry, Vol.75, No.6, pp.602-6085, 1996. DOI: https://doi.org/10.1016/S0022-3913(96)90244-9
- K. J. Anusavice, P. H. Dehoff, C. W. Fairhurst, "Comparative evaluation of ceramic-metal bond tests using finite element stress analysis", Journal of Dental Research, Vol.59, No.3, pp.608-613, 1980. https://doi.org/10.1177/00220345800590030901
- M. De Kler, N. De Jager, M. Meegdes, J. M. Van Der Zel, "Influence of thermal expansion mismatch and fatigue loading on phase changes in porcelain veneered Y-TZP zirconia discs", Journal of Oral Rehabilitation, Vol.34, No.11, pp.841-847, 2007. DOI: https://doi.org/10.1111/j.1365-2842.2006.01675.x
- C. W. Fairhurst, K. J. Anusavice, R. D. Ringle, S. W. Twiggs, "Porcelain-metal thermal compatibility", Journal of Dental Research, Vol.60, No.4, pp.815-819, 1981. https://doi.org/10.1177/00220345810600040801
- M. E. Comlekoglu, M. Dundar, M. Ozcan, M. A. Gungor, B. Gokce, C. Artunc, "Evaluation of bond strength of various margin ceramics to a zirconia ceramic", Journal of Dentistry, Vol.36, No.10, pp.822-827, 2008. DOI: https://doi.org/10.1016/j.jdent.2008.05.019