• Title/Summary/Keyword: Wire Control

Search Result 931, Processing Time 0.028 seconds

Effects of high glucose with or without other metabolic substrates on alpha-adrenergic contractions in rat mesenteric and femoral arteries

  • Vorn, Rany;Yoo, Hae Young
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.21 no.1
    • /
    • pp.91-97
    • /
    • 2017
  • Hyperglycemia is associated with an increased risk of cardiovascular diseases. It has been demonstrated that chronic exposure to high glucose impaired endothelial functions. However, specific effects of short-term exposure to high glucose on vascular reactivity are controversial. Moreover, the combined effects of other metabolic substrates such as free fatty acids (FFA) on vascular reactivity remain poorly understood. Here we investigate the effects of short-term exposure to high glucose with or without other metabolic substrates including FFAs termed "nutrition full" (NF) solution, on mesenteric (MA) and deep femoral arteries (DFA) of rats. Arterial ring segments were mounted in a double-wire myograph. Contraction in response to phenylephrine (PhE) was determined in control (5 mM) and high glucose (23 mM, HG) environments over a 30 min period. In both arteries, PhE-inducedvasocontraction was enhanced by pre-incubation of HG solution. A combined incubation with HG and palmitic acid ($100{\mu}M$) induced similar sensitization of PhE-contractions in both arteries. In contrast, high $K^+$-induced contractions were not affected by HG. Interestingly, pre-incubation with NF solution decreased PhE-induced contraction in MA but increased the contraction in DFA. In NF solution, the HG-induced facilitation of PhE-contraction was not observed in MA. Furthermore, the PhE-induced contraction of DFA was attenuated by HG in NF solution. Our results demonstrate that the sensitization of PhE-induced arterial contraction by HG is differentially affected by other metabolic substrates. The conversation of skeletal arterial contractility by HG in NF solution requires careful interpretation of the previous in vitro studies where only glucose is included in physiological salt solutions. Further studies are required to elucidate the mechanism underlying the inconsistent effect of NF solution on MA and DFA.

Development of a dynamic sensing system for civil revolving structures and its field tests in a large revolving auditorium

  • Luo, Yaozhi;Yang, Pengcheng;Shen, Yanbin;Yu, Feng;Zhong, Zhouneng;Hong, Jiangbo
    • Smart Structures and Systems
    • /
    • v.13 no.6
    • /
    • pp.993-1014
    • /
    • 2014
  • In civil engineering, revolving structures (RS) are a unique structural form applied in innovative architecture design. Such structures are able to revolve around themselves or along a certain track. However, few studies are dedicated to safety design or health monitoring of RS. In this paper, a wireless dynamic sensing system is developed for RS, and field tests toward a large revolving auditorium are conducted accordingly. At first, a wheel-rail problem is proposed: The internal force redistributes in RS, which is due to wheel-rail irregularity. Then the development of the sensing system for RS is presented. It includes system architecture, network organization, vibrating wire sensor (VWS) nodes and online remote control. To keep the sensor network identifiable during revolving, the addresses of sensor nodes are reassigned dynamically when RS position changes. At last, the system is mounted on a huge outdoor revolving auditorium. Considering the influence of the proposed problem, the RS of the auditorium has been designed conservatively. Two field tests are conducted via the sensing system. In the first test, 2000 people are invited to act as the live load. During the revolving process, data is collected from RS in three different load cases. The other test is the online monitoring for the auditorium during the official performances. In the end, the field-testing result verifies the existence of the wheel-rail problem. The result also indicates the dynamic sensing system is applicable and durable even while RS is rotating.

A Study on the Evaluation of the Service Quality of Port-MIS (항만운영정보시스템(Port-MIS) 서비스 품질 평가에 관한 연구)

  • Kim, Minjin;Shin, Seungsik
    • Journal of Korea Port Economic Association
    • /
    • v.29 no.2
    • /
    • pp.211-238
    • /
    • 2013
  • The Port Logistics Information System (Port-MIS) is the system that processes all of port management such as entry and departure of ships, using facilities within ports, port traffic control, cargo entering and carrying and tax collection in 31 trade ports over the whole country. Lately, The Port Logistics Information System (Port-MIS) has been reformed as a WEB-based system and established basis to provide real time information support structure, diversification of civil complaint system, and optimized civil complaint service by using wire and wireless internet. The typical study on the Port Logistics Information System was C/S program and EDI-centered. But it has significance to study on service quality measurement of WEB Port-MIS that has been served as a new web-based platform since April 2010, for there was no such a study until now.

Multiplatform Game Development using Wire and Wireless Communication (멀티플랫폼 유무선 연동게임 개발)

  • Kang, Youn-Jun;Park, Dong-Gyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.828-834
    • /
    • 2009
  • To get a better profit, standalone mobile game market shifts network-based mobile game. Currently, most of the game platform are separated into mobile to mobile, desktop to desktop, and console to console. Multi platform network game has a diverse problems including consistency control, object management technique, and bandwidth inconsistency. n this paper, we will introduce a multi-platform arcade game "Push-Push", which is played on desktop to mobile environment. The game guarantees realtime play between heterogeneous machine users and game item sharing between two platforms. e will focus n the issues of the 3rd generation multi platform games and propose some techniques or solving these problems. Our server database is implemented on MS SQL database, also the desktop programming tool is Visual Basic, and WIPI(Wireless Internet Platform or Interoperability) as a mobile platform.

Design and Implementation of On-Chip Network Architecture for Improving Latency Efficiency (지연시간 효율 개선을 위한 On-Chip Network 구조 설계 및 구현)

  • Jo, Seong-Min;Cho, Han-Wook;Ha, Jin-Seok;Song, Yong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.11
    • /
    • pp.56-65
    • /
    • 2009
  • As increasing the number of IPs integrated in a single chip and requiring high communication bandwidth on a chip, the trend of SoC communication architecture is changed from bus- or crossbar-based architecture to packet switched network architecture, NoC. However, highly complex control logics in routers require multiple cycles to switch packet. In this paper, we design low complex router to improve the communication latency. Our NoC design is verified by simulation platform modeled by ESL tool, SoC Designer. We also evaluate our NoC design comparing to the previous NoC architecture based on VC router. Our results show that our NoC architecture has less communication latency, even small throughput degradation (about 1-2%).

A Survey on the Contents of Fluoride, Calcium, and Magnesium of Reservoir Water on a Stream in the Jeon-buk Area of Korea (전북 지역 일부 수원지의 물에서 불소, 칼슘 및 마그네슘 함량에 관한 조사 연구)

  • 이인규;김종규
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.38-44
    • /
    • 2003
  • This study was performed to investigate the levels of fluoride (F), calcium (Ca), and magnesium (Mg) in water samples taken from five reservoirs or direct sources on a stream used for agricultural or domestic water in the Iksan and Wanjoo areas, Jeon-buk, Korea, and to find a possible link between Ca or Mg and fluoride in water sources in theses areas. The samples were collected by the recommendation methods of the World Health Organization and analyzed by the recommendations of the Japanese Standard Methods. Statistical analyses were performed by the analysis of variance and correlation analysis. The F levels in water samples wire 0.80~2.53 ppm. In four sampling sites the water fluoride levels exceeded 1 ppm. which if the recommended level for fluorosis/caries control. The Ca levels in water samples were 6.82~12.98 ppm, and the Mg levels were 0.30~1.97 ppm, which are lower compared with the natural levels of water sources previously reported by other investigators. This study showed a positive correlation between Ca and Mg (r= 0.8779. p<0.01) and a negative correlation between F and Ca (r=-0.6974, p<0.05) and also between F and Mg (r=-0.5581) in the water samples. However, the study did not find remarkable relationships in fluoride levels between sampling sites. These results support the fact that there were epidemics of dental fluorosis in this area. The lack of significant positive correlations in fluoride levels between sampling sites suggests that there may be some pathways for the transfer of the metal to the water through other environmental media besides the water course. Long-term epidemiological studies are needed on the relationship between high F together with low Ca and Mg levels in the water, and total human health in this community. There should alto be a long-term monitoring of the water quality in this area.

Lock-on Characteristics of Wake Behind a Rotationally Oscillating Circular Cylinder (주기적으로 회전진동하는 원주 후류의 공진특성에 관한 연구)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.895-902
    • /
    • 2005
  • Lock-on characteristics of flow around a circular cylinder oscillating rotationally with a relatively high forcing frequency have been investigated experimentally. Dominant governing parameters are Reynolds number (Re), angular amplitude of oscillation (${\theta}_A$), and frequency ratio $F_R=f_f/f_n,\;where\;f_f$ is a forcing frequency and $f_n$ is a natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\pi}/90{\leq}{\theta_A}{\leq}{\pi}/3,\;and\;F_R=1.0$. The effect of this active flow control technique on the lock-on flow characteristics of the cylinder wake was evaluated with wake velocity measurements and spectral analysis of hot-wire signals. The rotational oscillation modifies the flow structure of near wake significantly. The lock-on phenomenon always occurs at $F_R=1.0$, regardless of the angular amplitude ${\theta}_A$. In addition, when the angular amplitude is less than a certain value, the lock-on characteristics appear only at $F_R=1.0$,. The range of lock-on phenomena expands and vortex formation length is decreased, as the angular amplitude increases. The rotational oscillation create a small-scale vortex structure in the region just near the cylinder surface. At ${\theta}_A=60^{\circ}$, the drag coefficient was reduced about $43.7\%$ at maximum.

Fabrication and Evaluation of Digital Signal Processor for Multi-Lane Energy Measurement System (개별 전로 전력 계측을 위한 디지털 신호처리 프로세서 기반 전력 관제 시스템의 제작 및 평가)

  • Kim, Geun-Jun;Kang, Bongsoon
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.619-623
    • /
    • 2018
  • Due to the development of society, the demand for electric power has increased and the quality control of electric power has become an important issue. In order to efficiently perform such power management, we propose a DSP based power measurement system for multi-wire power measurement. Since the conventional power measurement system can measure only the power of one line, a power quality measurement device is required for each line in order to measure the power quality of the individual line. Respectively. The system proposed in this paper proposes a system capable of real-time measurement of power quality at up to 12 points using digital signal processing algorithm, and the prototype based on this system was evaluated through the official test report of Korea Electrotechnology Research Institute. As a result of the performance test, it was evaluated that the error range is excellent at ${\pm}0.3%$.

Development of Diagnosis System Adopted Intelligent Smart Junction Box for Improving Vehicular Power Safety (차량 전원 안정성 향상을 위한 Diagnosis System 채택 Intelligent Smart Junction Box 개발)

  • Jeong, Min-Soo;Kim, Mun-Gyeom;Park, Young-Hoan;Bang, Soon-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.276-285
    • /
    • 2008
  • These days the automobile industry, which has rapidly progressed, has been an indispensable part in social and economic activities as well as its research and development have been activated in response to various needs of consumers and markets. The second and third generation control system, getting count on safety and convenience differently than early circuits, cause the hypertrophy of wire harness. The J/Box(Junction Box), which distributes power and wires, was developed to solve the problem. As vehicles have been better in quantity and intelligence, however, environment-friendly electric apparatus system has continuously increased and ITS(Intelligent Transport System) has been introduced in earnest. In result, wires got complicated and multilateral and also there has been a stronger probability that vehicles are out of order due to various problems including mechanical failure. In this study, ISJB(Intelligent Smart Junction Box) was introduced to solve the problem. The diagnosis system was applied to prevent the overload and short of ISJE. Also, the state of vehicles displayed so that drivers monitor it in motion. Likewise error data are saved in the memory so that such data can be analyzed retrospectively. The busbar was adopted in to the main power terminal and the part of power pattern was coverd by lead. Because ISJB is more sensitive to heat in comparison to the busbar type J/Box. With regard the circuits related with safe, alternative circuits were set up in order that electronic devices may be normally operated even when an error arises. ISJB is expected to improve the safety and quality of vehicles.

Analysis of Different Ways of Drainage for Obstructive Jaundice Caused by Hilar Cholangiocarcinoma

  • Xu, Chuan;Lv, Peng-Hua;Huang, Xin-En;Wang, Shu-Xiang;Sun, Ling;Wang, Fu-An
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5617-5620
    • /
    • 2014
  • Objective: To evaluate the prognosis of different ways of drainage for patients with obstructive jaundice caused by hilar cholangiocarcinoma. Materials and Methods: During the period of January 2006- March 2012, percutaneous transhepatic catheter drainage (PTCD)/ percutaneous transhepatic biliary stenting (PTBS) were performed for 89 patients. According to percutaneous transhepatic cholangiography (PTC), external drainage was selected if the region of obstruction could not be passed by guide wire or a metallic stent was inserted if it could. External drainage was the first choice if infection was diagnosed before the procedure, and a metallic stent was inserted in one week after the infection was under control. Selection by new infections, the degree of bilirubin decrease, the change of ALT, the time of recurrence of obstruction, and the survival time of patients as the parameters was conducted to evaluate the methods of different interventional treatments regarding prognosis of patients with hilar obstruction caused by hilar cholangiocarcinoma. Results: PTCD was conducted in 6 patients and PTBS in 7 (p<0.05). Reduction of bilirubin levels and ALT levels was obvious after the procedures (p<0.05). The average survival time with PTCD was 161 days and with PTBS was 243 days (p<0.05). Conclusions: With both drainage procedures for obstructive jaundice caused by hilar cholangiocarcinoma improvement in liver function was obvious. PTBS was found to be better than PTCD for prolonging the patient survival.