• Title/Summary/Keyword: Winding factors

Search Result 51, Processing Time 0.029 seconds

Harmonic Winding Factors and MMF Analysis for Five-phase Fractional-slot Concentrated Winding PMSM

  • Kang, Huilin;Zhou, Libing;Wang, Jin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2014
  • To enhance torque density by harmonic current injection, optimal slot/pole combinations for five-phase permanent magnet synchronous motors (PMSM) with fractional-slot concentrated windings (FSCW) are chosen. The synchronous and the third harmonic winding factors are calculated for a series of slot/pole combinations. Two five-phase PMSM, with general FSCW (GFSCW) and modular stator FSCW (MFSCW), are analyzed and compared in detail, including the stator structures, star of slots diagrams, and MMF harmonic analysis based on the winding function theory. The analytical results are verified by finite element method, the torque characteristics and phase back-EMF are also taken into considerations. Results show that the MFSCW PMSM can produce higher average torque, while characterized by more MMF harmonic contents and larger ripple torque.

Analysis of the Insulation aging for the stator winding (고정자권선의 절연열화 특성분석)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Han, Chang-Dong;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.23-24
    • /
    • 2006
  • Stator winding of hydro generator is gradually deteriorated by multi-stress and steady degradation of insulation results in insulation breakdown. The region where insulation breakdown occurs in stator winding is part where the multi-stress causes the defect of insulation material and electrical stress has been concentrated. Therefore, we judged locations of insulation breakdown to be varied according to various stress factors in service. In this paper, we drew the stator winding of hydro generators which has run for a long time and separated it into 3 parts(central part, end winding part, drawing part) according to the positions laid on the core. We performed electrical and thermal stress on these specimens for 1000 hrs under the same condition, measured the condition regularlyand analyzed the insulation status of each winding by performing partial discharge test. In addition, we analyzed the trend of partial discharge concerning specimens that caused the insulation breakdown during aging.

  • PDF

Evaluation of Network Reshuffling Alternatives Based on Key Factors Affecting the Mode Share of Seoul Metro (서울시 도시철도 이용에 영향을 미치는 요소를 반영한 노선 조정 효과 분석)

  • Jo, Dohyoung;Sohn, Keemin;Kim, Daehyun;Kim, Ikki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6D
    • /
    • pp.935-943
    • /
    • 2006
  • Key factors affecting the mode share of Soul metro are investigated. The log-regression model, which can describe the elasticity of the factors with ease, is established rather than the conventional mode choice model is used. The log-regression model requires lower level of data availability for calibration and identifies the impact of the factors on mode share straightforwardly. As a result, it is found that the main reasons why the current mode share of railway is low are due to several problems such as winding lines, inconvenient transfers and unnecessary bypasses. The calibrated model is adopted to evaluate the network reshuffling alternatives. The network reshuffling is to rearrange the existing inefficient railway lines that have frequent transfers and many winding segments. The proposed network reshuffling, which includes straightening winding lines and changing grade separated transfers into cross-platform transfers, turned out to be a good measure to tackle the problems.

Cooling System for Power Transformer Using Weighting Function (하중함수를 이용한 전력용 변압기 냉각 시스템)

  • Cho, Do-Hyeoun
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.40-45
    • /
    • 2012
  • In this paper, cooling system of power transformers is proposed for temperature optimized control. We predict the peak temperature of power transformer coils using load factors and construct a cooling system using weighting function. For the optimized temperature control for power transformer, a correlation function based on the load factor of a load current and the each temperatures for winding coils, for air and for oil is presented to predict the winding-coil peak temperature. Also, the results controlled by applying the power transformer is presented.

Fault determination of power transformer by using analysis of vibration signal (진동신호 분석을 이용한 변압기 고장판별법 연구)

  • Park, Su-Mun;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1152-1154
    • /
    • 1996
  • In power transformers, vibration occurs at winding, core and case due to current, voltage, temperature changing and winding reformation. Winding deformation and change of vibration signals are occurred due to electromagnetic force induced by fault current. In this paper, in normal and fault states, the trends of fundamental waves and higher harmonics are considered. To inspect the factors that affect the fundamental waves and higher harmonics, the trends are considered with varying voltage and load. Determination functions are generated and applied to signals so that normal and fault state are determined by determination functions.

  • PDF

Design and Fabrication of Filament Wound Composite Lattice Structures (필라멘트와인딩에 의해 제조된 Lattice 구조물의 설계 및 제작 연구)

  • Doh, Young-Dae;Chung, Sang-Ki;Lee, Sang-Woo;Son, Jo-Hwa
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.421-427
    • /
    • 2010
  • This paper is concerned with Anisogrid composite lattice structures whose load bearing shell is formed by systems of geodesic unidirectional composite ribs made by automatic wet winding process. Lattice structures are usually made in the form of cylindrical shell and consist of systems of helical and hoop ribs fabricated by continuous filament winding from carbon and epoxy composites. Design variables of the structure which are the angle of helical ribs, ribs spacings, and cross sectional areas are determined by the method of minimization of satety factors whick is described in the paper. And, fabrication methods and actual experimental results are presented.

  • PDF

A Study on the Performance of Ak Heaters -Black Coating Materials, Coating Methods and Structure of Air Path- (평판식 태양열 공기가열기의 성능에 관한 연구 -도장재료, 도장방법 및 공기통로 구조를 중심으로-)

  • 박종길;연광석;차균도
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.1
    • /
    • pp.78-85
    • /
    • 1979
  • In order to obtain the basic data for designing optimum flat plate solar air heaters, which can be operated with relatively low temperature for drying farm products, 8 different treatment of solar air heaters were devised and tested for their heating performances and efficiencies. The results were analised and summarized as follows. 1. The primary factors, structure of air path (C), black coating materials (A) and bottom coating methods (B) showed very high significant effect of far above 1% level. With respect to the mutual multiplying effect of secondary factors, 1% level of significance was found with coating materials and methods (AB), and 5% level of significance was found with coating materials and air path structure (AC). 2. The heating performance of the air heaters with winding air path showed about twice those with straight air path. 3. The Korean black ink which is less expensive than dim oil paint showed 3-4% better heating efficiencies as the black coating material of flat plate solar air heaters. 4. The heating efficiencies of the solar air heaters whose bottoms were not black coated were 2-3% higher than those with black coated bottoms. 5. The highest heating efficiency of solar air heater among 8 different treatment was found in the plot of Korean black ink-bottom not coated-winding air path showing 29.0-34.5%

  • PDF

A Study on the New Criteria for Assessing the Insulation Deterioration of Generator Stator Winding (발전기 고정자 권선의 새로운 절연열화 판정기준 설정에 관한 연구)

  • Hwang, D.H.;Kim, Y.J.;Kim, J.B.;Jeon, J.W.;Kim, H.G.;Park, J.J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1692-1695
    • /
    • 1997
  • This paper describes the relationship between the various non-destructive parameters and the breakdown voltage for the 17 kV, 300 MVA and the 22 kV, 500 MVA generators stator bars with polyester and epoxy/mica insulation respectively. Also, this study reports the results of an investigation into the factors which can assess the insulation condition of generator stator winding. Furthermore, a new parameter, Partial Discharge Index(PDI), is introduced as the valuable parameter for the assessment of insulation condition. The ratio between partial discharge increment and the stepwise voltage increment from the Discharge Inception Voltage (DIV) at the characteristic or resonant frequency band shows the close relationship between the breakdown voltage and PDI.

  • PDF

Mechanical and Environment Ability of FRP Pole for a Distribution Line (배전용 FRP전주의 기계적 및 환경성능)

  • 박기호;조한구;한동희;이웅선;송일근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.395-398
    • /
    • 2000
  • In this study mechanical and environment ability of FRP pole for a distribution line about high strength and good insulation properties. The basic filament winding process creates a helical winding pattern. In mechanical analysis of splice with mechanical fastened joint it is important to evaluate a critical load of faster having maximum stress. It is also present a result of several examples to compare this with analytical one. On repair design this finite element method will be used as basis. The influence of environmental factors, such as elevated temperatures, high humidity, and corrosive fluids, and ultraviolet(UV) rays, upon the performance of polymeric matrix composite is of concern in many applications.

  • PDF

The Characteristic of Temperature in Ventilating Fans by Festraint or Nonrestraint (무 구속·구속 실험에 의한 환풍기 온도 특성)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.44-48
    • /
    • 2016
  • In this paper, we analyzed the operating characteristics of a ventilating fan due to overload and overheating. The experiment assumed the forcible restraint of the blade due to external objects and the aging process. We analyzed the experimental temperature and operating characteristics of the three places in the interior of the ventilating fan. As a result of the analysis, the temperature distribution was highest to lowest in the following order: the thermal fuse, the motor inside, and the above winding. There was smell of burning enamel in the restraint experiment. Following the thermal fuse operation, the insulation of motor winding was good. In the case of rated voltage and new ventilating fan restrained for about 4hours, and the results of restraint experiments in the presence or absence of the thermal fuse, no risk of deformation or fire due to overheating was identified. Henceforward, ignition hazard experiments will be required for additional factors of aging, pollution, and defective insulation.